-
1
-
-
77950445175
-
-
The Royal College of Radiologists, Society and College of Radiographers, Institute of Physics and Engineering in Medicine, (The Royal College of Radiologists, London).
-
The Royal College of Radiologists, Society and College of Radiographers, Institute of Physics and Engineering in Medicine, On Target: Ensuring Geometric Accuracy in Radiotherapy (The Royal College of Radiologists, London, 2008).
-
(2008)
On Target: Ensuring Geometric Accuracy in Radiotherapy
-
-
-
2
-
-
0035018405
-
Clinical use of electronic portal imaging: Report of AAPM Radiation Therapy Committee Task Group 58
-
DOI 10.1118/1.1368128
-
M. G. Herman, J. M. Balter, D. A. Jaffray, K. P. McGee, P. Munro, S. Shalev, M. Van Herk, and J. W. Wong, " Clinical use of electronic portal imaging: Report of AAPM Radiation Therapy Committee Task Group 58.," Med. Phys. 0094-2405 28, 712-737 (2001). 10.1118/1.1368128 (Pubitemid 32467250)
-
(2001)
Medical Physics
, vol.28
, Issue.5
, pp. 712-737
-
-
Herman, M.G.1
Balter, J.M.2
Jaffray, D.A.3
McGee, K.P.4
Munro, P.5
Shalev, S.6
Van Herk, M.7
Wong, J.W.8
-
3
-
-
34247516976
-
Daily monitoring of linear accelerator beam parameters using an amorphous silicon EPID
-
DOI 10.1088/0031-9155/52/6/012, PII S0031915507320434, 012
-
G. J. Budgell, R. Zhang, and R. I. Mackay, " Daily monitoring of linear accelerator beam parameters using an amorphous silicon EPID.," Phys. Med. Biol. 0031-9155 52, 1721-1733 (2007). 10.1088/0031-9155/52/6/012 (Pubitemid 46646377)
-
(2007)
Physics in Medicine and Biology
, vol.52
, Issue.6
, pp. 1721-1733
-
-
Budgell, G.J.1
Zhang, R.2
Mackay, R.I.3
-
4
-
-
33744966857
-
Anatomy changes in radiotherapy detected using portal imaging
-
DOI 10.1016/j.radonc.2006.04.003, PII S0167814006001538
-
L. N. McDermott, M. Wendling, J. J. Sonke, M. van Herk, and B. J. Mijnheer, " Anatomy changes in radiotherapy detected using portal imaging.," Radiother. Oncol. 0167-8140 79, 211-217 (2006). 10.1016/j.radonc.2006.04.003 (Pubitemid 43867816)
-
(2006)
Radiotherapy and Oncology
, vol.79
, Issue.2
, pp. 211-217
-
-
McDermott, L.N.1
Wendling, M.2
Sonke, J.-J.3
Van Herk, M.4
Mijnheer, B.J.5
-
5
-
-
52049100092
-
A literature review of electronic portal imaging for radiotherapy dosimetry
-
0167-8140,. 10.1016/j.radonc.2008.07.003
-
W. van Elmpt, L. N. McDermott, S. M. Nijsten, M. Wendling, P. Lambin, and B. J. Mijnheer, " A literature review of electronic portal imaging for radiotherapy dosimetry.," Radiother. Oncol. 0167-8140 88, 289-309 (2008). 10.1016/j.radonc.2008.07.003
-
(2008)
Radiother. Oncol.
, vol.88
, pp. 289-309
-
-
Van Elmpt, W.1
McDermott, L.N.2
Nijsten, S.M.3
Wendling, M.4
Lambin, P.5
Mijnheer, B.J.6
-
6
-
-
33745655388
-
Comparison of ghosting effects for three commercial a-Si EPIDs
-
DOI 10.1118/1.2207318
-
L. N. McDermott, S. M. Nijsten, J. J. Sonke, M. Partridge, M. van Herk, and B. J. Mijnheer, " Comparison of ghosting effects for three commercial a-Si EPIDs.," Med. Phys. 0094-2405 33, 2448-2451 (2006). 10.1118/1.2207318 (Pubitemid 43967232)
-
(2006)
Medical Physics
, vol.33
, Issue.7
, pp. 2448-2451
-
-
McDermott, L.N.1
Nijsten, S.M.J.J.G.2
Sonke, J.-J.3
Partridge, M.4
Van Herk, M.5
Mijnheer, B.J.6
-
7
-
-
34748821714
-
Off-axis dose response characteristics of an amorphous silicon electronic portal imaging device
-
DOI 10.1118/1.2779944
-
P. B. Greer, " Off-axis dose response characteristics of an amorphous silicon electronic portal imaging device.," Med. Phys. 0094-2405 34, 3815-3824 (2007). 10.1118/1.2779944 (Pubitemid 47482883)
-
(2007)
Medical Physics
, vol.34
, Issue.10
, pp. 3815-3824
-
-
Greer, P.B.1
-
8
-
-
0038033842
-
Dosimetric properties of an amorphous silicon electronic portal imaging device for verification of dynamic intensity modulated radiation therapy
-
DOI 10.1118/1.1582469
-
P. B. Greer and C. C. Popescu, " Dosimetric properties of an amorphous silicon electronic portal imaging device for verification of dynamic intensity modulated radiation therapy.," Med. Phys. 0094-2405 30, 1618-1627 (2003). 10.1118/1.1582469 (Pubitemid 36885779)
-
(2003)
Medical Physics
, vol.30
, Issue.7
, pp. 1618-1627
-
-
Greer, P.B.1
Popescu, C.C.2
-
9
-
-
58149214092
-
Assessment of dosimetrical performance in 11 Varian a-Si-500 electronic portal imaging devices
-
0031-9155,. 10.1088/0031-9155/53/23/016
-
A. Kavuma, M. Glegg, G. Currie, and A. Elliott, " Assessment of dosimetrical performance in 11 Varian a-Si-500 electronic portal imaging devices.," Phys. Med. Biol. 0031-9155 53, 6893-6909 (2008). 10.1088/0031-9155/53/23/016
-
(2008)
Phys. Med. Biol.
, vol.53
, pp. 6893-6909
-
-
Kavuma, A.1
Glegg, M.2
Currie, G.3
Elliott, A.4
-
10
-
-
1942478371
-
The use of an aSi-based EPID for routine absolute dosimetric pre-treatment verification of dynamic IMRT fields
-
DOI 10.1016/j.radonc.2004.02.018, PII S016781400400088X
-
A. Van Esch, T. Depuydt, and D. P. Huyskens, " The use of an aSi-based EPID for routine absolute dosimetric pre-treatment verification of dynamic IMRT fields.," Radiother. Oncol. 0167-8140 71, 223-234 (2004). 10.1016/j.radonc.2004.02.018 (Pubitemid 38521192)
-
(2004)
Radiotherapy and Oncology
, vol.71
, Issue.2
, pp. 223-234
-
-
Van Esch, A.1
Depuydt, T.2
Huyskens, D.P.3
-
11
-
-
9244240768
-
The long-term stability of amorphous silicon flat panel imaging devices for dosimetry purposes
-
DOI 10.1118/1.1803751
-
R. J. Louwe, L. N. McDermott, J. J. Sonke, R. Tielenburg, M. Wendling, M. B. van Herk, and B. J. Mijnheer, " The long-term stability of amorphous silicon flat panel imaging devices for dosimetry purposes.," Med. Phys. 0094-2405 31, 2989-2995 (2004). 10.1118/1.1803751 (Pubitemid 39552688)
-
(2004)
Medical Physics
, vol.31
, Issue.11
, pp. 2989-2995
-
-
Louwe, R.J.W.1
McDermott, L.N.2
Sonke, J.-J.3
Tielenburg, R.4
Wendling, M.5
Van Herk, M.B.6
Mijnheer, B.J.7
-
12
-
-
33644999533
-
Correction of pixel sensitivity variation and off-axis response for amorphous silicon EPID dosimetry
-
0094-2405,. 10.1118/1.2128498
-
P. B. Greer, " Correction of pixel sensitivity variation and off-axis response for amorphous silicon EPID dosimetry.," Med. Phys. 0094-2405 32, 3558-3568 (2005). 10.1118/1.2128498
-
(2005)
Med. Phys.
, vol.32
, pp. 3558-3568
-
-
Greer, P.B.1
-
13
-
-
27244439568
-
Dose-response characteristics of an amorphous silicon EPID
-
DOI 10.1118/1.2040711
-
P. Winkler, A. Hefner, and D. Georg, " Dose-response characteristics of an amorphous silicon EPID.," Med. Phys. 0094-2405 32, 3095-3105 (2005). 10.1118/1.2040711 (Pubitemid 41513098)
-
(2005)
Medical Physics
, vol.32
, Issue.10
, pp. 3095-3105
-
-
Winkler, P.1
Hefner, A.2
Georg, D.3
-
14
-
-
2542441748
-
Investigation of the optimal backscatter for an aSi electronic portal imaging device
-
DOI 10.1088/0031-9155/49/9/010, PII S0031915504724707
-
L. Ko, J. O. Kim, and J. V. Siebers, " Investigation of the optimal backscatter for an aSi electronic portal imaging device.," Phys. Med. Biol. 0031-9155 49, 1723-1738 (2004). 10.1088/0031-9155/49/9/010 (Pubitemid 38678711)
-
(2004)
Physics in Medicine and Biology
, vol.49
, Issue.9
, pp. 1723-1738
-
-
Ko, L.1
Kim, J.O.2
Siebers, J.V.3
-
15
-
-
20044368303
-
Verification of the optimal backscatter for an aSi electronic portal imaging device
-
DOI 10.1088/0031-9155/50/10/011
-
J. A. Moore and J. V. Siebers, " Verification of the optimal backscatter for an aSi electronic portal imaging device.," Phys. Med. Biol. 0031-9155 50, 2341-2350 (2005). 10.1088/0031-9155/50/10/011 (Pubitemid 40767820)
-
(2005)
Physics in Medicine and Biology
, vol.50
, Issue.10
, pp. 2341-2350
-
-
Moore, J.A.1
Siebers, J.V.2
-
16
-
-
85027232445
-
-
presented at the Proceedings of the Tenth International WorkshoEPI2K8 Electronic Portal Imaging and Positioning Device, San Francisco, CA, 20-22 May (unpublished).
-
P. B. Greer, " The effect of non-uniform backscatter on EPID dosimetry.," presented at the Proceedings of the Tenth International Workshop EPI2K8 Electronic Portal Imaging and Positioning Device, San Francisco, CA, 20-22 May 2008 (unpublished).
-
(2008)
The Effect of Non-uniform Backscatter on EPID Dosimetry
-
-
Greer, P.B.1
-
17
-
-
33747611733
-
An intercomparison of 11 amorphous silicon EPIDs of the same type: Implications for portal dosimetry
-
DOI 10.1088/0031-9155/51/17/005, PII S003191550623642X, 005
-
P. Winkler and D. Georg, " An intercomparison of 11 amorphous silicon EPIDs of the same type: Implications for portal dosimetry.," Phys. Med. Biol. 0031-9155 51, 4189-4200 (2006). 10.1088/0031-9155/51/17/005 (Pubitemid 44261839)
-
(2006)
Physics in Medicine and Biology
, vol.51
, Issue.17
, pp. 4189-4200
-
-
Winkler, P.1
Georg, D.2
-
18
-
-
73649128290
-
Dosimetric verification of IMAT delivery with a conventional EPID system and a commercial portal dose image prediction tool
-
0094-2405,. 10.1118/1.3271107
-
M. Iori, E. Cagni, M. Paiusco, P. Munro, and A. E. Nahum, " Dosimetric verification of IMAT delivery with a conventional EPID system and a commercial portal dose image prediction tool.," Med. Phys. 0094-2405 37, 377-390 (2010). 10.1118/1.3271107
-
(2010)
Med. Phys.
, vol.37
, pp. 377-390
-
-
Iori, M.1
Cagni, E.2
Paiusco, M.3
Munro, P.4
Nahum, A.E.5
|