Volumn 79, Issue 2, 2006, Pages 211-217

Anatomy changes in radiotherapy detected using portal imaging

Author keywords

Anatomy changes; EPID; Portal imaging

Indexed keywords

ANATOMY; ARTICLE; CANCER LOCALIZATION; CANCER RADIOTHERAPY; CANCER SIZE; CLINICAL PRACTICE; COMPARATIVE STUDY; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DOSE RESPONSE; DOSIMETRY; HEAD AND NECK CANCER; HUMAN; IMAGE ANALYSIS; IMAGING SYSTEM; LUNG CANCER; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; PROSTATE CANCER; QUALITATIVE DIAGNOSIS; RADIATION DOSE; RECTUM; TARGET ORGAN; TREATMENT DURATION; TREATMENT PLANNING; TREATMENT RESPONSE; VARIANCE;

EID: 33744966857     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radonc.2006.04.003     Document Type: Article
Times cited : (36)

References (24)
  • 1
    • 3042520594 scopus 로고    scopus 로고
    • Quantification of volumetric and geometric changes occurring during fractionated radiotherapy for head-and-neck cancer using an integrated CT/linear accelerator system
    • Barker Jr. J.L., Garden A.S., Ang K.K., et al. Quantification of volumetric and geometric changes occurring during fractionated radiotherapy for head-and-neck cancer using an integrated CT/linear accelerator system. Int J Radiat Oncol Biol Phys 59 (2004) 960-970
    • (2004) Int J Radiat Oncol Biol Phys , vol.59 , pp. 960-970
    • Barker Jr., J.L.1    Garden, A.S.2    Ang, K.K.3
  • 2
    • 0031744989 scopus 로고    scopus 로고
    • First clinical tests using a liquid-filled electronic portal imaging device and a convolution model for the verification of the midplane dose
    • Boellaard R., van Herk M., Uiterwaal H., and Mijnheer B. First clinical tests using a liquid-filled electronic portal imaging device and a convolution model for the verification of the midplane dose. Radiother Oncol 47 (1998) 303-312
    • (1998) Radiother Oncol , vol.47 , pp. 303-312
    • Boellaard, R.1    van Herk, M.2    Uiterwaal, H.3    Mijnheer, B.4
  • 3
    • 0842327792 scopus 로고    scopus 로고
    • Effects of motion on the total dose distribution
    • Bortfeld T., Jiang S.B., and Rietzel E. Effects of motion on the total dose distribution. Semin Radiat Oncol 14 (2004) 41-51
    • (2004) Semin Radiat Oncol , vol.14 , pp. 41-51
    • Bortfeld, T.1    Jiang, S.B.2    Rietzel, E.3
  • 5
    • 0037249948 scopus 로고    scopus 로고
    • Portal imaging to assess set-up errors, tumor motion and tumor shrinkage during conformal radiotherapy of non-small cell lung cancer
    • Erridge S.C., Seppenwoolde Y., Muller S.H., et al. Portal imaging to assess set-up errors, tumor motion and tumor shrinkage during conformal radiotherapy of non-small cell lung cancer. Radiother Oncol 66 (2003) 75-85
    • (2003) Radiother Oncol , vol.66 , pp. 75-85
    • Erridge, S.C.1    Seppenwoolde, Y.2    Muller, S.H.3
  • 6
    • 0035036846 scopus 로고    scopus 로고
    • The use of dynamic phantoms in interventional radiology
    • Guibelade E., Vano E., Kotre C.J., et al. The use of dynamic phantoms in interventional radiology. Radiat Prot Dosimetry 94 (2001) 155-159
    • (2001) Radiat Prot Dosimetry , vol.94 , pp. 155-159
    • Guibelade, E.1    Vano, E.2    Kotre, C.J.3
  • 7
    • 0030002611 scopus 로고    scopus 로고
    • The application of transit dosimetry to precision radiotherapy
    • Hansen V.N., Evans P.M., and Swindell W. The application of transit dosimetry to precision radiotherapy. Med Phys 23 (1996) 713-721
    • (1996) Med Phys , vol.23 , pp. 713-721
    • Hansen, V.N.1    Evans, P.M.2    Swindell, W.3
  • 8
    • 12444264448 scopus 로고    scopus 로고
    • A study of the effects of internal organ motion on dose escalation in conformal prostate treatments
    • Happersett L., Mageras G.S., Zelefsky M.J., et al. A study of the effects of internal organ motion on dose escalation in conformal prostate treatments. Radiother Oncol 66 (2003) 263-270
    • (2003) Radiother Oncol , vol.66 , pp. 263-270
    • Happersett, L.1    Mageras, G.S.2    Zelefsky, M.J.3
  • 9
    • 14744296853 scopus 로고    scopus 로고
    • Strategies to reduce the systematic error due to tumor and rectum motion in radiotherapy of prostate cancer
    • Hoogeman M.S., van Herk M., de Bois J., and Lebesque J.V. Strategies to reduce the systematic error due to tumor and rectum motion in radiotherapy of prostate cancer. Radiother Oncol 74 (2005) 177-185
    • (2005) Radiother Oncol , vol.74 , pp. 177-185
    • Hoogeman, M.S.1    van Herk, M.2    de Bois, J.3    Lebesque, J.V.4
  • 10
    • 0032433905 scopus 로고    scopus 로고
    • In vivo dosimetry for prostate cancer patients using an electronic portal imaging device (EPID); demonstration of internal organ motion
    • Kroonwijk M., Pasma K.L., Quint S., Koper P.C., Visser A.G., and Heijmen B.J. In vivo dosimetry for prostate cancer patients using an electronic portal imaging device (EPID); demonstration of internal organ motion. Radiother Oncol 49 (1998) 125-132
    • (1998) Radiother Oncol , vol.49 , pp. 125-132
    • Kroonwijk, M.1    Pasma, K.L.2    Quint, S.3    Koper, P.C.4    Visser, A.G.5    Heijmen, B.J.6
  • 11
    • 0141631863 scopus 로고    scopus 로고
    • Three-dimensional dose reconstruction of breast cancer treatment using portal imaging
    • Louwe R.J.W., Damen E.M., van Herk M., Minken A.W., Torzsok O., and Mijnheer B.J. Three-dimensional dose reconstruction of breast cancer treatment using portal imaging. Med Phys 30 (2003) 2376-2389
    • (2003) Med Phys , vol.30 , pp. 2376-2389
    • Louwe, R.J.W.1    Damen, E.M.2    van Herk, M.3    Minken, A.W.4    Torzsok, O.5    Mijnheer, B.J.6
  • 12
    • 9244240768 scopus 로고    scopus 로고
    • The long-term stability of amorphous silicon flat panel imaging devices for dosimetry purposes
    • Louwe R.J.W., McDermott L.N., Sonke J.-J., et al. The long-term stability of amorphous silicon flat panel imaging devices for dosimetry purposes. Med Phys 31 (2004) 2989-2995
    • (2004) Med Phys , vol.31 , pp. 2989-2995
    • Louwe, R.J.W.1    McDermott, L.N.2    Sonke, J.-J.3
  • 13
    • 0142089327 scopus 로고    scopus 로고
    • A method for incorporating organ motion due to breathing into 3D dose calculations in the liver: sensitivity to variations in motion
    • Lujan A.E., Balter J.M., and Ten Haken R.K. A method for incorporating organ motion due to breathing into 3D dose calculations in the liver: sensitivity to variations in motion. Med Phys 30 (2003) 2643-2649
    • (2003) Med Phys , vol.30 , pp. 2643-2649
    • Lujan, A.E.1    Balter, J.M.2    Ten Haken, R.K.3
  • 14
    • 1242271376 scopus 로고    scopus 로고
    • Dose-response and ghosting effects of an amorphous silicon electronic portal imaging device
    • McDermott L.N., Louwe R.J., Sonke J.J., van Herk M.B., and Mijnheer B.J. Dose-response and ghosting effects of an amorphous silicon electronic portal imaging device. Med Phys 31 (2004) 285-295
    • (2004) Med Phys , vol.31 , pp. 285-295
    • McDermott, L.N.1    Louwe, R.J.2    Sonke, J.J.3    van Herk, M.B.4    Mijnheer, B.J.5
  • 15
    • 0037295522 scopus 로고    scopus 로고
    • Dosimetric implications of changes in patient repositioning and organ motion in conformal radiotherapy for prostate cancer
    • Miralbell R., Ozsoy O., Pugliesi A., et al. Dosimetric implications of changes in patient repositioning and organ motion in conformal radiotherapy for prostate cancer. Radiother Oncol 66 (2003) 197-202
    • (2003) Radiother Oncol , vol.66 , pp. 197-202
    • Miralbell, R.1    Ozsoy, O.2    Pugliesi, A.3
  • 16
    • 0036703540 scopus 로고    scopus 로고
    • IMRT verification by three-dimensional dose reconstruction from portal beam measurements
    • Partridge M., Ebert M., and Hesse B.M. IMRT verification by three-dimensional dose reconstruction from portal beam measurements. Med Phys 29 (2002) 1847-1858
    • (2002) Med Phys , vol.29 , pp. 1847-1858
    • Partridge, M.1    Ebert, M.2    Hesse, B.M.3
  • 17
    • 0032784892 scopus 로고    scopus 로고
    • Transit dosimetry with an electronic portal imaging device (EPID) for 115 prostate cancer patients
    • Pasma K.L., Kroonwijk M., Quint S., Visser A.G., and Heijmen B.J. Transit dosimetry with an electronic portal imaging device (EPID) for 115 prostate cancer patients. Int J Radiat Oncol Biol Phys 45 (1999) 1297-1303
    • (1999) Int J Radiat Oncol Biol Phys , vol.45 , pp. 1297-1303
    • Pasma, K.L.1    Kroonwijk, M.2    Quint, S.3    Visser, A.G.4    Heijmen, B.J.5
  • 18
    • 27944498960 scopus 로고    scopus 로고
    • An optimisation algorithm for determination of treatment margins around moving and deformable targets
    • Redpath A.T., and Muren L.P. An optimisation algorithm for determination of treatment margins around moving and deformable targets. Radiother Oncol 77 (2005) 194-201
    • (2005) Radiother Oncol , vol.77 , pp. 194-201
    • Redpath, A.T.1    Muren, L.P.2
  • 19
    • 1542610649 scopus 로고    scopus 로고
    • Tracking the dose distribution in radiation therapy by accounting for variable anatomy
    • Schaly B., Kempe J.A., Bauman G.S., Battista J.J., and Van Dyk J. Tracking the dose distribution in radiation therapy by accounting for variable anatomy. Phys Med Biol 49 (2004) 791-805
    • (2004) Phys Med Biol , vol.49 , pp. 791-805
    • Schaly, B.1    Kempe, J.A.2    Bauman, G.S.3    Battista, J.J.4    Van Dyk, J.5
  • 21
    • 0842306308 scopus 로고    scopus 로고
    • Errors and margins in radiotherapy
    • van Herk M. Errors and margins in radiotherapy. Semin Radiat Oncol 14 (2004) 52-64
    • (2004) Semin Radiat Oncol , vol.14 , pp. 52-64
    • van Herk, M.1
  • 22
    • 0032177617 scopus 로고    scopus 로고
    • Automatic registration of pelvic computed tomography data and magnetic resonance scans including a full circle method for quantitative accuracy evaluation
    • van Herk M., de Munck J.C., Lebesque J.V., Muller S., Rasch C., and Touw A. Automatic registration of pelvic computed tomography data and magnetic resonance scans including a full circle method for quantitative accuracy evaluation. Med Phys 25 (1998) 2054-2067
    • (1998) Med Phys , vol.25 , pp. 2054-2067
    • van Herk, M.1    de Munck, J.C.2    Lebesque, J.V.3    Muller, S.4    Rasch, C.5    Touw, A.6
  • 23
    • 0031421636 scopus 로고    scopus 로고
    • Effect of image artifacts, organ motion, and poor segmentation on the reliability and accuracy of three-dimensional chamfer matching
    • van Herk M.B., Gilhuijs K.G., de Munck J., and Touw A. Effect of image artifacts, organ motion, and poor segmentation on the reliability and accuracy of three-dimensional chamfer matching. Comput Aided Surg 2 (1997) 346-355
    • (1997) Comput Aided Surg , vol.2 , pp. 346-355
    • van Herk, M.B.1    Gilhuijs, K.G.2    de Munck, J.3    Touw, A.4
  • 24
    • 1642377027 scopus 로고    scopus 로고
    • Verification of step-and-shoot IMRT delivery using a fast video-based electronic portal imaging device
    • Zeidan O.A., Li J.G., Ranade M., Stell A.M., and Dempsey J.F. Verification of step-and-shoot IMRT delivery using a fast video-based electronic portal imaging device. Med Phys 31 (2004) 463-476
    • (2004) Med Phys , vol.31 , pp. 463-476
    • Zeidan, O.A.1    Li, J.G.2    Ranade, M.3    Stell, A.M.4    Dempsey, J.F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.