-
1
-
-
0028919251
-
Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43. American Association of Physicists in Medicine
-
0094-2405,. 10.1118/1.597458
-
R. Nath, L. L. Anderson, G. Luxton, K. A. Weaver, J. F. Williamson, and A. S. Meigooni, " Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43. American Association of Physicists in Medicine.," Med. Phys. 0094-2405 22, 209-234 (1995). 10.1118/1.597458
-
(1995)
Med. Phys.
, vol.22
, pp. 209-234
-
-
Nath, R.1
Anderson, L.L.2
Luxton, G.3
Weaver, K.A.4
Williamson, J.F.5
Meigooni, A.S.6
-
2
-
-
1142304255
-
Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations
-
DOI 10.1118/1.1646040
-
M. J. Rivard, B. M. Coursey, L. A. DeWerd, W. F. Hanson, M. S. Huq, G. S. Ibbott, M. G. Mitch, R. Nath, and J. F. Williamson, " Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations.," Med. Phys. 0094-2405 31, 633-674 (2004). 10.1118/1.1646040 (Pubitemid 38381028)
-
(2004)
Medical Physics
, vol.31
, Issue.3
, pp. 633-674
-
-
Rivard, M.J.1
Coursey, B.M.2
DeWerd, L.A.3
Hanson, W.F.4
Huq, M.S.5
Ibbott, G.S.6
Mitch, M.G.7
Nath, R.8
Williamson, J.F.9
-
3
-
-
0025922323
-
Calibration of i 192 r high-dose-rate afterloading systems
-
0094-2405,. 10.1118/1.596649
-
S. J. Goetsch, F. H. Attix, D. W. Pearson, and B. R. Thomadsen, " Calibration of I 192 r high-dose-rate afterloading systems.," Med. Phys. 0094-2405 18, 462-467 (1991). 10.1118/1.596649
-
(1991)
Med. Phys.
, vol.18
, pp. 462-467
-
-
Goetsch, S.J.1
Attix, F.H.2
Pearson, D.W.3
Thomadsen, B.R.4
-
5
-
-
33748294452
-
192Ir HDR brachytherapy sources
-
DOI 10.1118/1.2239198
-
E. Mainegra-Hing and D. W. Rogers, " On the accuracy of techniques for obtaining the calibration coefficient N(K) of I 192 r HDR brachytherapy sources.," Med. Phys. 0094-2405 33, 3340-3347 (2006). 10.1118/1.2239198 (Pubitemid 44327437)
-
(2006)
Medical Physics
, vol.33
, Issue.9
, pp. 3340-3347
-
-
Mainegra-Hing, E.1
Rogers, D.W.O.2
-
6
-
-
0033861873
-
Monte Carlo study of correction factors for Spencer - Attix cavity theory at photon energies at or above 100 keV
-
DOI 10.1118/1.1287054
-
J. Borg, I. Kawrakow, D. W. Rogers, and J. P. Seuntjens, " Monte Carlo study of correction factors for Spencer-Attix cavity theory at photon energies at or above 100 keV.," Med. Phys. 0094-2405 27, 1804-1813 (2000). 10.1118/1.1287054 (Pubitemid 30666356)
-
(2000)
Medical Physics
, vol.27
, Issue.8
, pp. 1804-1813
-
-
Borg, J.1
Kawrakow, I.2
Rogers, D.W.O.3
Seuntjens, J.P.4
-
7
-
-
0037035293
-
192Ir HDR energy
-
DOI 10.1088/0031-9155/47/7/304, PII S003191550231697X
-
K. N. Rajan, T. P. Selvam, B. C. Bhatt, M. Vijayam, V. S. Patki, Vinatha, A. M. Pendse, and V. Kannan, " Direct calibration of a reference standard against the air kerma strength primary standard, at I 192 r HDR energy.," Phys. Med. Biol. 0031-9155 47, 1047-1058 (2002). 10.1088/0031-9155/47/7/304 (Pubitemid 34413630)
-
(2002)
Physics in Medicine and Biology
, vol.47
, Issue.7
, pp. 1047-1058
-
-
Govinda Rajan, K.N.1
Palani Selvam, T.2
Bhatt, B.C.3
Vijayam, M.4
Patki, V.S.5
Vinatha6
Pendse, A.M.7
Kannan, V.8
-
8
-
-
0034820630
-
192Ir HDR source
-
DOI 10.1088/0031-9155/46/9/303, PII S0031915501239645
-
T. P. Selvam, K. N. Rajan, P. S. Nagarajan, P. Sethulakshmi, and B. C. Bhatt, " Monte Carlo aided room scatter studies in the primary air kerma strength standardization of a remote afterloading I 192 r HDR source.," Phys. Med. Biol. 0031-9155 46, 2299-2315 (2001). 10.1088/0031-9155/46/9/303 (Pubitemid 32895529)
-
(2001)
Physics in Medicine and Biology
, vol.46
, Issue.9
, pp. 2299-2315
-
-
Palani Selvam, T.1
Govinda Rajan, K.N.2
Nagarajan, P.S.3
Sethulakshmi, P.4
Bhatt, B.C.5
-
9
-
-
56749158507
-
Determination of absorbed dose in water at the reference point d(r0, theta0) for an i 192 r HDR brachytherapy source using a Fricke system
-
0094-2405,. 10.1118/1.2996178
-
C. Austerlitz, H. C. Mota, J. Sempau, S. M. Benhabib, D. Campos, R. Allison, C. E. DeAlmeida, D. Zhu, and C. H. Sibata, " Determination of absorbed dose in water at the reference point d(r0, theta0) for an I 192 r HDR brachytherapy source using a Fricke system.," Med. Phys. 0094-2405 35, 5360-5365 (2008). 10.1118/1.2996178
-
(2008)
Med. Phys.
, vol.35
, pp. 5360-5365
-
-
Austerlitz, C.1
Mota, H.C.2
Sempau, J.3
Benhabib, S.M.4
Campos, D.5
Allison, R.6
Dealmeida, C.E.7
Zhu, D.8
Sibata, C.H.9
-
10
-
-
0018865260
-
Absorbed dose water calorimeter
-
DOI 10.1118/1.594664
-
S. R. Domen, " Absorbed dose water calorimeter.," Med. Phys. 0094-2405 7, 157-159 (1980). 10.1118/1.594664 (Pubitemid 10147258)
-
(1980)
Medical Physics
, vol.7
, Issue.2
, pp. 157-159
-
-
Domen, S.R.1
-
11
-
-
65249109852
-
Photon absorbed dose standards
-
0026-1394,. 10.1088/0026-1394/46/2/S04
-
J. Seuntjens and S. Duane, " Photon absorbed dose standards.," Metrologia 0026-1394 46, S39-S58 (2009). 10.1088/0026-1394/46/2/S04
-
(2009)
Metrologia
, vol.46
-
-
Seuntjens, J.1
Duane, S.2
-
12
-
-
0030067356
-
Water calorimetry and ionization chamber dosimetry in an 85-MeV clinical proton beam
-
DOI 10.1118/1.597700
-
H. Palmans, J. Seuntjens, F. Verhaegen, J. Denis, S. Vynckier, and H. Thierens, " Water calorimetry and ionization chamber dosimetry in an 85-MeV clinical proton beam.," Med. Phys. 0094-2405 23, 643-650 (1996). 10.1118/1.597700 (Pubitemid 26000110)
-
(1996)
Medical Physics
, vol.23
, Issue.5
, pp. 643-650
-
-
Palmans, H.1
Seuntjens, J.2
Verhaegen, F.3
Denis, J.-M.4
Vynckier, S.5
Thierens, H.6
-
13
-
-
0026574482
-
Water calorimeter dosimetry for 160 MeV protons
-
0031-9155,. 10.1088/0031-9155/37/4/009
-
R. J. Schulz, L. J. Verhey, M. S. Huq, and N. Venkataramanan, " Water calorimeter dosimetry for 160 MeV protons.," Phys. Med. Biol. 0031-9155 37, 947-953 (1992). 10.1088/0031-9155/37/4/009
-
(1992)
Phys. Med. Biol.
, vol.37
, pp. 947-953
-
-
Schulz, R.J.1
Verhey, L.J.2
Huq, M.S.3
Venkataramanan, N.4
-
14
-
-
77950586670
-
Sci-YIS Fri-05: Design and testing of a new sealed water calorimeter for electron beams
-
0094-2405.
-
K. Stewart, N. V. Klassen, C. K. Ross, and J. Seuntjens, " Sci-YIS Fri-05: Design and testing of a new sealed water calorimeter for electron beams.," Med. Phys. 0094-2405 32, 2419 (2005).
-
(2005)
Med. Phys.
, vol.32
, pp. 2419
-
-
Stewart, K.1
Klassen, N.V.2
Ross, C.K.3
Seuntjens, J.4
-
15
-
-
17044435381
-
Active radiometric calorimeter for absolute calibration of radioactive sources
-
DOI 10.1063/1.1867032, 033504
-
K. E. Stump, L. A. DeWerd, D. A. Rudman, and S. A. Schima, " Active radiometric calorimeter for absolute calibration of radioactive sources.," Rev. Sci. Instrum. 0034-6748 76, 033504 (2005). 10.1063/1.1867032 (Pubitemid 40493872)
-
(2005)
Review of Scientific Instruments
, vol.76
, Issue.3
, pp. 1-9
-
-
Stump, K.E.1
Dewerd, L.A.2
Rudman, D.A.3
Schima, S.A.4
-
16
-
-
36649026668
-
An absorbed dose to water standard for HDR 192Ir brachytherapy sources based on water calorimetry: Numerical and experimental proof-of-principle
-
DOI 10.1118/1.2815941
-
A. Sarfehnia, K. Stewart, and J. Seuntjens, " An absorbed dose to water standard for HDR I 192 r brachytherapy sources based on water calorimetry: Numerical and experimental proof-of-principle.," Med. Phys. 0094-2405 34, 4957-4961 (2007). 10.1118/1.2815941 (Pubitemid 350197731)
-
(2007)
Medical Physics
, vol.34
, Issue.12
, pp. 4957-4961
-
-
Sarfehnia, A.1
Stewart, K.2
Seuntjens, J.3
-
18
-
-
77950582039
-
-
presented at the 11th International Congress of the IUPESM-Medical Physics and Biomedical Engineering World Congress 2009, Munich, Germany, (unpublished).
-
M. Bambynek, A. Krauss, and H. J. Selbach, " Calorimetric determination of absorbed dose to water for a I 192 r HDR brachytherapy source in near-field geometry.," presented at the 11th International Congress of the IUPESM-Medical Physics and Biomedical Engineering World Congress 2009, Munich, Germany, 2009 (unpublished).
-
(2009)
Calorimetric Determination of Absorbed Dose to Water for A i 192 R HDR Brachytherapy Source in Near-field Geometry
-
-
Bambynek, M.1
Krauss, A.2
Selbach, H.J.3
-
19
-
-
0011869815
-
A sealed water calorimeter for measuring absorbed dose
-
1044-677X.
-
S. R. Domen, " A sealed water calorimeter for measuring absorbed dose.," J. Res. Natl. Inst. Stand. Technol. 1044-677X 99, 121-141 (1994).
-
(1994)
J. Res. Natl. Inst. Stand. Technol.
, vol.99
, pp. 121-141
-
-
Domen, S.R.1
-
20
-
-
0033040827
-
Correction factors and performance of a 4°C sealed water calorimeter
-
DOI 10.1088/0031-9155/44/3/001, PII S0031915599955422
-
J. Seuntjens and H. Palmans, " Correction factors and performance of a 4 degrees C sealed water calorimeter.," Phys. Med. Biol. 0031-9155 44, 627-646 (1999). 10.1088/0031-9155/44/3/001 (Pubitemid 29133058)
-
(1999)
Physics in Medicine and Biology
, vol.44
, Issue.3
, pp. 627-646
-
-
Seuntjens, J.1
Palmans, H.2
-
21
-
-
0036508163
-
Water calorimetry: A correction to the heat defect calculations
-
1044-677X.
-
N. V. Klassen and C. K. Ross, " Water calorimetry: A correction to the heat defect calculations.," J. Res. Natl. Inst. Stand. Technol. 1044-677X 107, 171-178 (2002).
-
(2002)
J. Res. Natl. Inst. Stand. Technol.
, vol.107
, pp. 171-178
-
-
Klassen, N.V.1
Ross, C.K.2
-
22
-
-
33646635381
-
-
NRCC Report No. PIRS-877 (Ottawa, Canada).
-
I. Kawrakow, E. Mainegra-Hing, and D. W. O. Rogers, " The EGSnrcMP: The multi-platform environment for EGSnrc.," NRCC Report No. PIRS-877 (Ottawa, Canada, 2000).
-
(2000)
The EGSnrcMP: The Multi-platform Environment for EGSnrc
-
-
Kawrakow, I.1
Mainegra-Hing, E.2
Rogers, D.W.O.3
-
23
-
-
85027234182
-
-
National Nuclear Data Center, Nuclear data from NuDat, a web-based database maintained by the National Nuclear Data Center, Brookhaven National Laboratory, Upton, NY.
-
National Nuclear Data Center, 2004 Nuclear data from NuDat, a web-based database maintained by the National Nuclear Data Center, Brookhaven National Laboratory, Upton, NY, http://www.nndc.bnl.gov/nudat2/.
-
(2004)
-
-
-
24
-
-
0034746154
-
192Ir sources used for endovascular brachytherapy
-
DOI 10.1088/0031-9155/46/2/316, PII S0031915501175093
-
N. Reynaert, M. Van Eijkeren, Y. Taeymans, and H. Thierens, " Dosimetry of I 192 r sources used for endovascular brachytherapy.," Phys. Med. Biol. 0031-9155 46, 499-516 (2001). 10.1088/0031-9155/46/2/316 (Pubitemid 32148512)
-
(2001)
Physics in Medicine and Biology
, vol.46
, Issue.2
, pp. 499-516
-
-
Reynaert, N.1
Van Eijkeren, M.2
Taeymans, Y.3
Thierens, H.4
-
25
-
-
54949134922
-
EGSnrc Monte Carlo calculated dosimetry parameters for i 192 r and 169Yb brachytherapy sources
-
0094-2405,. 10.1118/1.2987676
-
R. E. Taylor and D. W. Rogers, " EGSnrc Monte Carlo calculated dosimetry parameters for I 192 r and 169Yb brachytherapy sources.," Med. Phys. 0094-2405 35, 4933-4944 (2008). 10.1118/1.2987676
-
(2008)
Med. Phys.
, vol.35
, pp. 4933-4944
-
-
Taylor, R.E.1
Rogers, D.W.2
-
26
-
-
50449095484
-
An EGSnrc Monte Carlo-calculated database of TG-43 parameters
-
0094-2405,. 10.1118/1.2965360
-
R. E. Taylor and D. W. Rogers, " An EGSnrc Monte Carlo-calculated database of TG-43 parameters.," Med. Phys. 0094-2405 35, 4228-4241 (2008). 10.1118/1.2965360
-
(2008)
Med. Phys.
, vol.35
, pp. 4228-4241
-
-
Taylor, R.E.1
Rogers, D.W.2
-
27
-
-
0031739032
-
Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source
-
DOI 10.1118/1.598418
-
G. M. Daskalov, E. Loffler, and J. F. Williamson, " Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source.," Med. Phys. 0094-2405 25, 2200-2208 (1998). 10.1118/1.598418 (Pubitemid 28530111)
-
(1998)
Medical Physics
, vol.25
, Issue.11
, pp. 2200-2208
-
-
Daskalov, G.M.1
Loffler, E.2
Williamson, J.F.3
-
29
-
-
0003777714
-
-
84th ed., edited by D. R. Lide (CRC, Cleveland, OH).
-
CRC Handbook of Chemistry and Physics, 84th ed., edited by, D. R. Lide, (CRC, Cleveland, OH, 2003).
-
(2003)
CRC Handbook of Chemistry and Physics
-
-
-
30
-
-
85027234320
-
-
presented at the NPL Workshoon Recent Advances in Calorimetric Absorbed Dose Standards, National Physical Laboratory, Teddington, UK, (unpublished).
-
J. Seuntjens, I. Kawrakow, and C. K. Ross, " Revisiting convective motion in stagnant water calorimeters operated at room temperature.," presented at the NPL Workshop on Recent Advances in Calorimetric Absorbed Dose Standards, National Physical Laboratory, Teddington, UK, 2000 (unpublished).
-
(2000)
Revisiting Convective Motion in Stagnant Water Calorimeters Operated at Room Temperature
-
-
Seuntjens, J.1
Kawrakow, I.2
Ross, C.K.3
-
31
-
-
0029895014
-
192Ir source using a primary and scatter dose separation technique
-
DOI 10.1088/0031-9155/41/6/005
-
K. R. Russell and A. Ahnesjo, " Dose calculation in brachytherapy for a I 192 r source using a primary and scatter dose separation technique.," Phys. Med. Biol. 0031-9155 41, 1007-1024 (1996). 10.1088/0031-9155/41/6/005 (Pubitemid 26180239)
-
(1996)
Physics in Medicine and Biology
, vol.41
, Issue.6
, pp. 1007-1024
-
-
Russell, K.R.1
Ahnesjo, A.2
-
32
-
-
0027276162
-
Correction factors for a cylindrical ionization chamber used in medium-energy x-ray beams
-
J. Seuntjens, H. Thierens, and U. Schneider, " Correction factors for a cylindrical ionization chamber used in medium-energy x-ray beams.," Phys. Med. Biol. 0031-9155 38, 805-832 (1993). 10.1088/0031-9155/38/6/013 (Pubitemid 23188341)
-
(1993)
Physics in Medicine and Biology
, vol.38
, Issue.6
, pp. 805-832
-
-
Seuntjens, J.1
Thierens, H.2
Schneider, U.3
-
33
-
-
68149161213
-
Development of a scatter correction technique and its application to HDR i 192 r multicatheter breast brachytherapy
-
0094-2405,. 10.1118/1.3157105
-
E. Poon and F. Verhaegen, " Development of a scatter correction technique and its application to HDR I 192 r multicatheter breast brachytherapy.," Med. Phys. 0094-2405 36, 3703-3713 (2009). 10.1118/1.3157105
-
(2009)
Med. Phys.
, vol.36
, pp. 3703-3713
-
-
Poon, E.1
Verhaegen, F.2
-
34
-
-
22544440841
-
Precise radiochromic film dosimetry using a flat-bed document scanner
-
DOI 10.1118/1.1929253
-
S. Devic, J. Seuntjens, E. Sham, E. B. Podgorsak, C. R. Schmidtlein, A. S. Kirov, and C. G. Soares, " Precise radiochromic film dosimetry using a flat-bed document scanner.," Med. Phys. 0094-2405 32, 2245-2253 (2005). 10.1118/1.1929253 (Pubitemid 41023182)
-
(2005)
Medical Physics
, vol.32
, Issue.7
, pp. 2245-2253
-
-
Devic, S.1
Seuntjens, J.2
Sham, E.3
Podgorsak, E.B.4
Schmidtlein, C.R.5
Kirov, A.S.6
Soares, C.G.7
-
35
-
-
77950554933
-
Direct measurement of absorbed dose to water in HDR i 192 r brachytherapy: Water calorimetry, ionization chamber, Gafchromic Film, and TG-43
-
0094-2405.
-
A. Sarfehnia, I. Kawrakow, and J. Seuntjens, " Direct measurement of absorbed dose to water in HDR I 192 r brachytherapy: Water calorimetry, ionization chamber, Gafchromic Film, and TG-43.," Med. Phys. 0094-2405 37, 1924-1932 (2010).
-
(2010)
Med. Phys.
, vol.37
, pp. 1924-1932
-
-
Sarfehnia, A.1
Kawrakow, I.2
Seuntjens, J.3
|