-
1
-
-
85027218411
-
-
Radiological Physics Center, The M.D. Anderson Cancer Center, Houston, Texas; see.
-
Radiological Physics Center, The joint AAPM/RPC registry of brachytherapy sources., The M.D. Anderson Cancer Center, Houston, Texas; see http://rpc.mdanderson.org/rpc/.
-
The Joint AAPM/RPC Registry of Brachytherapy Sources
-
-
-
2
-
-
0028919251
-
-
Med. Phys..
-
R. Nath, L. L. Anderson, G. Luxton, K. A. Weaver, J. F. Williamson, and A. S. Meigooni, " Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43.," Med. Phys. 22, 209-234 (1995).
-
(1995)
Dosimetry of Interstitial Brachytherapy Sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43
, vol.22
, pp. 209-234
-
-
Nath, R.1
Anderson, L.L.2
Luxton, G.3
Weaver, K.A.4
Williamson, J.F.5
Meigooni, A.S.6
-
3
-
-
1142304255
-
-
Med. Phys..
-
M. J. Rivard, B. M. Coursey, L. A. DeWerd, M. S. Huq, G. S. Ibbott, M. G. Mitch, R. Nath, and J. F. Williamson, " Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations.," Med. Phys. 31, 633-674 (2004).
-
(2004)
Update of AAPM Task Group No. 43 Report: A Revised AAPM Protocol for Brachytherapy Dose Calculations
, vol.31
, pp. 633-674
-
-
Rivard, M.J.1
Coursey, B.M.2
Dewerd, L.A.3
Huq, M.S.4
Ibbott, G.S.5
Mitch, M.G.6
Nath, R.7
Williamson, J.F.8
-
4
-
-
34447302063
-
-
Med. Phys..
-
M. J. Rivard, W. M. Butler, L. A. DeWerd, M. S. Huq, G. S. Ibbott, A. S. Meigooni, C. S. Melhus, M. G. Mitch, R. Nath, and J. F. Williamson, " Supplement to the 2004 update of the AAPM Task Group No. 43 Report.," Med. Phys. 34, 2187-2205 (2007).
-
(2007)
Supplement to the 2004 Update of the AAPM Task Group No. 43 Report
, vol.34
, pp. 2187-2205
-
-
Rivard, M.J.1
Butler, W.M.2
Dewerd, L.A.3
Huq, M.S.4
Ibbott, G.S.5
Meigooni, A.S.6
Melhus, C.S.7
Mitch, M.G.8
Nath, R.9
Williamson, J.F.10
-
7
-
-
85027240125
-
-
MCNP-A general Monte Carlo N-particle Transport Code Version 5, Report LA-UR-03-1987, edited by F. B. Brown (Los Alamos National Laboratory, Los Alamos, NM).
-
MCNP-A general Monte Carlo N-particle Transport Code Version 5, Report LA-UR-03-1987, edited by, F. B. Brown, (Los Alamos National Laboratory, Los Alamos, NM, 2003).
-
(2003)
-
-
-
9
-
-
85027218075
-
-
The EGSnrc Code System: Monte Carlo simulation of Electron and Photon Transport, Technical Report PIRS-701 (National Research Council of Canada, Ottawa, Canada).
-
I. Kawrakow and D. W. O. Rogers, The EGSnrc Code System: Monte Carlo simulation of Electron and Photon Transport, Technical Report PIRS-701 (National Research Council of Canada, Ottawa, Canada, 2000).
-
(2000)
-
-
Kawrakow, I.1
Rogers, D.W.O.2
-
12
-
-
33846566263
-
-
Med. Phys..
-
R. E. P. Taylor, G. Yegin, and D. W. O. Rogers, " Benchmarking BrachyDose: Voxel-based EGSnrc Monte Carlo calculations of TG-43 dosimetry parameters.," Med. Phys. 34, 445-457 (2007).
-
(2007)
Benchmarking BrachyDose: Voxel-based EGSnrc Monte Carlo Calculations of TG-43 Dosimetry Parameters
, vol.34
, pp. 445-457
-
-
Taylor, R.E.P.1
Yegin, G.2
Rogers, D.W.O.3
-
14
-
-
0003966099
-
-
Report NBSIR87-3597, NIST, Gaithersburg, MD 20899.
-
M. J. Berger and J. H. Hubbell, XCOM: Photon Cross Sections on a Personal Computer., Report NBSIR87-3597, NIST, Gaithersburg, MD 20899, 1987.
-
(1987)
XCOM: Photon Cross Sections on a Personal Computer
-
-
Berger, M.J.1
Hubbell, J.H.2
-
15
-
-
33745489094
-
-
Quantitative dosimetry methods for brachytherapy," in, edited by B. R. Thomadsen, M. J. Rivard, and W. M. Butler (Medical Physics, Madison, WI)
-
J. F. Williamson and M. J. Rivard, " Quantitative dosimetry methods for brachytherapy.," in Brachytherapy Physics, edited by, B. R. Thomadsen, M. J. Rivard, and, W. M. Butler, (Medical Physics, Madison, WI, 2005), pp. 233-294.
-
(2005)
Brachytherapy Physics
, pp. 233-294
-
-
Williamson, J.F.1
Rivard, M.J.2
-
20
-
-
28044456522
-
-
Med. Phys..
-
G. Lymperopoulou, P. Papagiannis, A. Angelopoulos, L. Sakelliou, P. Karaiskos, P. Sandilos, A. Przykutta, and D. Baltas, " Monte Carlo and thermoluminescence dosimetry of the new IsoSeed model I125.S17 I125 interstitial brachytherapy seed.," Med. Phys. 32, 3313-3317 (2005).
-
(2005)
Monte Carlo and Thermoluminescence Dosimetry of the New IsoSeed Model I125.S17 I125 Interstitial Brachytherapy Seed
, vol.32
, pp. 3313-3317
-
-
Lymperopoulou, G.1
Papagiannis, P.2
Angelopoulos, A.3
Sakelliou, L.4
Karaiskos, P.5
Sandilos, P.6
Przykutta, A.7
Baltas, D.8
-
22
-
-
1642363889
-
-
J. Res. Natl. Inst. Stand. Technol..
-
S. M. Seltzer, P. J. Lamperti, R. Loevinger, M. G. Mitch, J. T. Weaver, and B. M. Coursey, " New national air-kerma-strength standards for I125 and Pd103 brachytherapy Seeds.," J. Res. Natl. Inst. Stand. Technol. 108, 337-358 (2003).
-
(2003)
New National Air-kerma-strength Standards for I125 and Pd103 Brachytherapy Seeds
, vol.108
, pp. 337-358
-
-
Seltzer, S.M.1
Lamperti, P.J.2
Loevinger, R.3
Mitch, M.G.4
Weaver, J.T.5
Coursey, B.M.6
-
23
-
-
33845310036
-
-
Med. Phys..
-
J. Dolan, Z. Li, and J. F. Williamson, " Monte Carlo and experimental dosimetry of an I125 brachytherapy seed.," Med. Phys. 33, 4675-4684 (2006).
-
(2006)
Monte Carlo and Experimental Dosimetry of An I125 Brachytherapy Seed
, vol.33
, pp. 4675-4684
-
-
Dolan, J.1
Li, Z.2
Williamson, J.F.3
-
26
-
-
0031836440
-
-
Phys. Med. Biol..
-
E. Mainegra, R. Capote, and E. Lopez, " Dose rate constants for Pd103, I125, Yb196, Ir192, brachytherapy sources: An EGS4 Monte Carlo study.," Phys. Med. Biol. 43, 1557-1566 (1998).
-
(1998)
Dose Rate Constants for Pd103, I125, Yb196, Ir192, Brachytherapy Sources: An EGS4 Monte Carlo Study
, vol.43
, pp. 1557-1566
-
-
Mainegra, E.1
Capote, R.2
Lopez, E.3
-
27
-
-
0034068736
-
-
Phys. Med. Biol..
-
E. Mainegra, R. Capote, and E. Lopez, " Radial dose functions for Pd103, I125, Yb196, Ir192, brachytherapy sources: An EGS4 Monte Carlo study.," Phys. Med. Biol. 45, 703-717 (2000).
-
(2000)
Radial Dose Functions for Pd103, I125, Yb196, Ir192, Brachytherapy Sources: An EGS4 Monte Carlo Study
, vol.45
, pp. 703-717
-
-
Mainegra, E.1
Capote, R.2
Lopez, E.3
-
28
-
-
0035136353
-
-
Phys. Med. Biol..
-
R. Capote, E. Mainegra, and E. Lopez, " Anisotropy functions for low energy interstitial brachytherapy sources: An EGS4 Monte Carlo study.," Phys. Med. Biol. 46, 135-150 (2001).
-
(2001)
Anisotropy Functions for Low Energy Interstitial Brachytherapy Sources: An EGS4 Monte Carlo Study
, vol.46
, pp. 135-150
-
-
Capote, R.1
Mainegra, E.2
Lopez, E.3
-
30
-
-
0035989937
-
-
Med. Phys..
-
A. S. Meigooni, S. A. Dini, K. Sowards, J. L. Hayes, and A. Al-Otoom, " Experimental determination of the TG-43 dosimetric characteristics of EchoSeed model 6733 I125 brachytherapy source.," Med. Phys. 29, 939-942 (2002).
-
(2002)
Experimental Determination of the TG-43 Dosimetric Characteristics of EchoSeed Model 6733 I125 Brachytherapy Source
, vol.29
, pp. 939-942
-
-
Meigooni, A.S.1
Dini, S.A.2
Sowards, K.3
Hayes, J.L.4
Al-Otoom, A.5
-
31
-
-
34347393909
-
-
Med. Phys..
-
R. Pirchio, E. Galiano, M. Saravi, D. Banchik, and C. Muñoz, " On the physical, spectra, and dosimetric characteristics of a new I125 brachytherapy source.," Med. Phys. 34, 2801-2806 (2007).
-
(2007)
On the Physical, Spectra, and Dosimetric Characteristics of a New I125 Brachytherapy Source
, vol.34
, pp. 2801-2806
-
-
Pirchio, R.1
Galiano, E.2
Saravi, M.3
Banchik, D.4
Muñoz, C.5
-
32
-
-
0342264356
-
-
Med. Phys..
-
H. Hedtjärn, G. A. Carlsson, and J. F. Williamson, " Monte Carlo-aided dosimetry of the symmetra model I25.S06 I125, interstitial brachytherapy seed.," Med. Phys. 27, 1076-1085 (2000).
-
(2000)
Monte Carlo-aided Dosimetry of the Symmetra Model I25.S06 I125, Interstitial Brachytherapy Seed
, vol.27
, pp. 1076-1085
-
-
Hedtjärn, H.1
Carlsson, G.A.2
Williamson, J.F.3
-
33
-
-
0034857269
-
-
Med. Phys..
-
N. S. Patel, S.-T. Chiu-Tsao, J. F. Williamson, P. Fan, T. Duckworth, D. Shasha, and L. B. Harrison, " Thermoluminescent dosimetry of the Symmetra I125 model I25.S06 interstitial brachytherapy seed.," Med. Phys. 28, 1761-1769 (2001).
-
(2001)
Thermoluminescent Dosimetry of the Symmetra I125 Model I25.S06 Interstitial Brachytherapy Seed
, vol.28
, pp. 1761-1769
-
-
Patel, N.S.1
Chiu-Tsao, S.-T.2
Williamson, J.F.3
Fan, P.4
Duckworth, T.5
Shasha, D.6
Harrison, L.B.7
-
34
-
-
33751538035
-
-
Nucl. Instrum. Methods Phys. Res. A.
-
E. Pantelis, D. Baltas, E. Georgiou, P. Karaiskos, G. Lymperopoulou, P. Papariannis, L. Sakelliou, I. Seimenis, and E. Stilliaris, " Dose characterization of the new Bebig IsoSeed I25.S17 using polymer gel and MRI.," Nucl. Instrum. Methods Phys. Res. A 569, 529-532 (2006).
-
(2006)
Dose Characterization of the New Bebig IsoSeed I25.S17 Using Polymer Gel and MRI
, vol.569
, pp. 529-532
-
-
Pantelis, E.1
Baltas, D.2
Georgiou, E.3
Karaiskos, P.4
Lymperopoulou, G.5
Papariannis, P.6
Sakelliou, L.7
Seimenis, I.8
Stilliaris, E.9
-
36
-
-
0033805914
-
-
Med. Phys..
-
A. S. Meigooni, D. M. Gearheart, and K. Sowards, " Experimental determination of dosimetric characteristics of Best I125 brachytherapy source.," Med. Phys. 27, 2168-2173 (2000).
-
(2000)
Experimental Determination of Dosimetric Characteristics of Best I125 Brachytherapy Source
, vol.27
, pp. 2168-2173
-
-
Meigooni, A.S.1
Gearheart, D.M.2
Sowards, K.3
-
41
-
-
2442712723
-
-
Med. Phys..
-
G. H. Chan, R. Nath, and J. F. Williamson, " On the development of consensus values of reference dosimetry parameters for interstitial brachytherapy sources.," Med. Phys. 31, 1040-1045 (2004).
-
(2004)
On the Development of Consensus Values of Reference Dosimetry Parameters for Interstitial Brachytherapy Sources
, vol.31
, pp. 1040-1045
-
-
Chan, G.H.1
Nath, R.2
Williamson, J.F.3
-
43
-
-
0036158984
-
-
Appl. Radiat. Isot..
-
A. S. Meigooni, M. M. Yoe-Sein, A. Y. Al-Otoom, and K. Sowards, " Determination of the dosimetric characteristics of InterSource I125 brachytherapy source.," Appl. Radiat. Isot. 56, 589-599 (2002).
-
(2002)
Determination of the Dosimetric Characteristics of InterSource I125 Brachytherapy Source
, vol.56
, pp. 589-599
-
-
Meigooni, A.S.1
Yoe-Sein, M.M.2
Al-Otoom, A.Y.3
Sowards, K.4
-
44
-
-
0035190490
-
-
Med. Phys..
-
B. Reniers, S. Vynckier, and P. Scalliet, " Dosimetric study of the new InterSource125 iodine seed.," Med. Phys. 28, 2285-2299 (2001).
-
(2001)
Dosimetric Study of the New InterSource125 Iodine Seed
, vol.28
, pp. 2285-2299
-
-
Reniers, B.1
Vynckier, S.2
Scalliet, P.3
-
45
-
-
33744826887
-
-
Med. Phys..
-
M. J. Rivard, W. M. Butler, L. A. DeWerd, M. S. Huq, G. S. Ibbott, C. S. Melhus, M. G. Mitch, R. Nath, and J. J. Williamson, " Response to "Comment on 'Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations.," Med. Phys. 32, 1822-1824 (2005).
-
(2005)
Response to "comment on 'update of AAPM Task Group No. 43 Report: A Revised AAPM Protocol for Brachytherapy Dose Calculations
, vol.32
, pp. 1822-1824
-
-
Rivard, M.J.1
Butler, W.M.2
Dewerd, L.A.3
Huq, M.S.4
Ibbott, G.S.5
Melhus, C.S.6
Mitch, M.G.7
Nath, R.8
Williamson, J.J.9
-
46
-
-
0033743964
-
-
Med. Phys..
-
D. M. Gearheart, A. Drogin, K. Sowards, A. Meigooni, and G. S. Ibbott, " Dosimetric characteristics of a new I125 brachytherapy source.," Med. Phys. 27, 2278-2285 (2000).
-
(2000)
Dosimetric Characteristics of a New I125 Brachytherapy Source
, vol.27
, pp. 2278-2285
-
-
Gearheart, D.M.1
Drogin, A.2
Sowards, K.3
Meigooni, A.4
Ibbott, G.S.5
-
54
-
-
0036732646
-
-
Med. Phys..
-
A. S. Meigooni, J. L. Hayes, H. Zhang, and K. Sowards, " Experimental and theoretical determination of dosimetric characteristics of IsoAid ADVANTAGETM I125 brachytherapy source.," Med. Phys. 29, 2152-2158 (2002).
-
(2002)
Experimental and Theoretical Determination of Dosimetric Characteristics of IsoAid ADVANTAGETM I125 Brachytherapy Source
, vol.29
, pp. 2152-2158
-
-
Meigooni, A.S.1
Hayes, J.L.2
Zhang, H.3
Sowards, K.4
-
55
-
-
85024987450
-
-
J. Appl. Clin. Med. Phys..
-
T. D. Solberg, J. J. DeMarco, G. Hugo, and R. E. Wallace, " Dosimetric parameters of three new solid core I-125 brachytherapy sources.," J. Appl. Clin. Med. Phys. 3, 119-134 (2002).
-
(2002)
Dosimetric Parameters of Three New Solid Core I-125 Brachytherapy Sources
, vol.3
, pp. 119-134
-
-
Solberg, T.D.1
Demarco, J.J.2
Hugo, G.3
Wallace, R.E.4
-
59
-
-
0034131036
-
-
Med. Phys..
-
Z. Li, J. J. Fan, and J. R. Palta, " Experimental measurements of dosimetric parameters on the transverse axis of a new I125 source.," Med. Phys. 27, 1275-1280 (2000).
-
(2000)
Experimental Measurements of Dosimetric Parameters on the Transverse Axis of a New I125 Source
, vol.27
, pp. 1275-1280
-
-
Li, Z.1
Fan, J.J.2
Palta, J.R.3
-
61
-
-
0034851950
-
-
Med. Phys..
-
P. Karaiskos, P. Papagiannis, L. Sakelliou, G. Anagnostopoulos, and D. Baltas, " Monte Carlo dosimetry of the selectSeed I125 interstitial brachytherapy seed.," Med. Phys. 28, 1753-1760 (2001).
-
(2001)
Monte Carlo Dosimetry of the SelectSeed I125 Interstitial Brachytherapy Seed
, vol.28
, pp. 1753-1760
-
-
Karaiskos, P.1
Papagiannis, P.2
Sakelliou, L.3
Anagnostopoulos, G.4
Baltas, D.5
-
62
-
-
0035999398
-
-
Med. Phys..
-
G. Anagnostopoulos, D. Baltas, P. Karaiskos, P. Sandilos, P. Papagiannis, and L. Sakelliou, " Thermoluminescent dosimetry of the selectSeed I125 interstitial brachytherapy seed.," Med. Phys. 29, 709-716 (2002).
-
(2002)
Thermoluminescent Dosimetry of the SelectSeed I125 Interstitial Brachytherapy Seed
, vol.29
, pp. 709-716
-
-
Anagnostopoulos, G.1
Baltas, D.2
Karaiskos, P.3
Sandilos, P.4
Papagiannis, P.5
Sakelliou, L.6
-
63
-
-
33646438838
-
-
Med. Phys..
-
P. Papagiannis, L. Sakelliou, G. Anagnostopoulos, and D. Baltas, " On the dose rate constant of the selectSeed I125 interstitial brachytherapy seed.," Med. Phys. 33, 1522-1523 (2006).
-
(2006)
On the Dose Rate Constant of the SelectSeed I125 Interstitial Brachytherapy Seed
, vol.33
, pp. 1522-1523
-
-
Papagiannis, P.1
Sakelliou, L.2
Anagnostopoulos, G.3
Baltas, D.4
-
64
-
-
0038710315
-
-
Med. Phys..
-
S. Chiu-Tsao, T. L. Duckworth, C. Hsiung, Z. Li, J. Williamson, N. Patel, and L. B. Harrison, " Thermoluminescent dosimetry of the SourceTech Medical model STM1251 I125 seed.," Med. Phys. 30, 1735-1732 (2003).
-
(2003)
Thermoluminescent Dosimetry of the SourceTech Medical Model STM1251 I125 Seed
, vol.30
, pp. 1735-1732
-
-
Chiu-Tsao, S.1
Duckworth, T.L.2
Hsiung, C.3
Li, Z.4
Williamson, J.5
Patel, N.6
Harrison, L.B.7
-
66
-
-
0033795853
-
-
Med. Phys..
-
C. C. Popescu, J. Wise, K. Sowards, A. S. Meigooni, and G. S. Ibbott, " Dosimetric characteristics of the PharmaSeed model BT-125-1 source.," Med. Phys. 27, 2174-2181 (2000).
-
(2000)
Dosimetric Characteristics of the PharmaSeed Model BT-125-1 Source
, vol.27
, pp. 2174-2181
-
-
Popescu, C.C.1
Wise, J.2
Sowards, K.3
Meigooni, A.S.4
Ibbott, G.S.5
-
67
-
-
0035999390
-
-
Med. Phys..
-
J. J. DeMarco, G. Hugo, and T. D. Solberg, " Dosimetric characteristics for three low-energy brachytherapy sources using the Monte Carlo N-Particle code.," Med. Phys. 29, 662-668 (2002).
-
(2002)
Dosimetric Characteristics for Three Low-energy Brachytherapy Sources Using the Monte Carlo N-Particle Code
, vol.29
, pp. 662-668
-
-
Demarco, J.J.1
Hugo, G.2
Solberg, T.D.3
-
69
-
-
0035543812
-
-
Med. Phys..
-
A. S. Meigooni, Z. Bharucha, M. Yoe-Sein, and K. Sowards, " Dosimetric characteristics of the Best double-wall Pd103 brachytherapy source.," Med. Phys. 28, 2567-2575 (2001).
-
(2001)
Dosimetric Characteristics of the Best Double-wall Pd103 Brachytherapy Source
, vol.28
, pp. 2567-2575
-
-
Meigooni, A.S.1
Bharucha, Z.2
Yoe-Sein, M.3
Sowards, K.4
-
71
-
-
0038486834
-
-
Appl. Radiat. Isot..
-
A. S. Meigooni, H. Zhang, C. Perry, S. A. Dini, and R. A. Koona, " Theoretical and experimental determination of dosimetric characteristics for brachyseed Pd-103, model Pd-1, source.," Appl. Radiat. Isot. 58, 533-541 (2003).
-
(2003)
Theoretical and Experimental Determination of Dosimetric Characteristics for Brachyseed Pd-103, Model Pd-1, Source
, vol.58
, pp. 533-541
-
-
Meigooni, A.S.1
Zhang, H.2
Perry, C.3
Dini, S.A.4
Koona, R.A.5
-
72
-
-
0036797392
-
-
Med. Phys..
-
R. Nath, N. Yue, and E. Roa, " Experimental determination of dosimetric characterization of a newly designed encapsulated interstitial brachytherapy source of Pd103 -model Pd-1.," Med. Phys. 29, 2433-2434 (2002).
-
(2002)
Experimental Determination of Dosimetric Characterization of a Newly Designed Encapsulated Interstitial Brachytherapy Source of Pd103 -model Pd-1
, vol.29
, pp. 2433-2434
-
-
Nath, R.1
Yue, N.2
Roa, E.3
-
74
-
-
0033625386
-
-
Med. Phys..
-
A. S. Meigooni, K. Sowards, and M. Soldano, " Dosimetric characteristics of InterSource103 palladium brachytherapy source.," Med. Phys. 27, 1093-1100 (2000).
-
(2000)
Dosimetric Characteristics of InterSource103 Palladium Brachytherapy Source
, vol.27
, pp. 1093-1100
-
-
Meigooni, A.S.1
Sowards, K.2
Soldano, M.3
-
77
-
-
33744533962
-
-
Appl. Radiat. Isot..
-
A. S. Meigooni, S. Dini, K. Dou, S. Awan, and G. Gopalakrishnan, " Experimental and Monte Carlo dosimetric characterization of ADVANTAGE Pd103.," Appl. Radiat. Isot. 64, 881-887 (2006).
-
(2006)
Experimental and Monte Carlo Dosimetric Characterization of ADVANTAGE Pd103
, vol.64
, pp. 881-887
-
-
Meigooni, A.S.1
Dini, S.2
Dou, K.3
Awan, S.4
Gopalakrishnan, G.5
-
80
-
-
0034046524
-
-
Med. Phys..
-
Z. Li, J. R. Palta, and J. J. Fan, " Monte Carlo caculations and experimental measurements of dosimetry parameters of a new Pd103 source.," Med. Phys. 27, 1108-1112 (2000).
-
(2000)
Monte Carlo Caculations and Experimental Measurements of Dosimetry Parameters of a New Pd103 Source
, vol.27
, pp. 1108-1112
-
-
Li, Z.1
Palta, J.R.2
Fan, J.J.3
-
85
-
-
0034004556
-
-
Med. Phys..
-
R. Nath, N. Yue, K. Shahnazi, and P. Bongiorini, " Measurement of dose-rate constant for Pd103 seeds with air kerma strength calibration based upon a primary national standard.," Med. Phys. 27, 655-658 (2000).
-
(2000)
Measurement of Dose-rate Constant for Pd103 Seeds with Air Kerma Strength Calibration Based Upon a Primary National Standard
, vol.27
, pp. 655-658
-
-
Nath, R.1
Yue, N.2
Shahnazi, K.3
Bongiorini, P.4
|