Volumn 46, Issue 9, 2001, Pages 2299-2315
|
Monte Carlo aided room scatter studies in the primary air kerma strength standardization of a remote afterloading 192Ir HDR source
a a a a a |
Author keywords
[No Author keywords available]
|
Indexed keywords
MONTE CARLO METHODS;
PHOTONS;
SCATTERING;
BRACHYTHERAPY TREATMENT ROOM;
PATIENT TREATMENT;
GRAPHITE;
IRIDIUM 192;
AIR;
ARTICLE;
BRACHYTHERAPY;
CALCULATION;
CONTROLLED STUDY;
IONIZATION CHAMBER;
PHOTON;
PRIORITY JOURNAL;
RADIATION DETECTOR;
RADIATION DOSE;
RADIATION ENERGY;
RADIATION SCATTERING;
STANDARDIZATION;
SYSTEM ANALYSIS;
AIR;
BRACHYTHERAPY;
IRIDIUM RADIOISOTOPES;
MODELS, THEORETICAL;
MONTE CARLO METHOD;
PHOTONS;
SCATTERING, RADIATION;
|
EID: 0034820630
PISSN: 00319155
EISSN: None
Source Type: Journal
DOI: 10.1088/0031-9155/46/9/303 Document Type: Article |
Times cited : (21)
|
References (21)
|