1
-
-
33749236625
-
30 day results from the SPACE trial of stent-protected angioplasty versus carotid endarterectomy in symptomatic patients: a randomised non-inferiority trial
-
Ringleb P.A., Allenberg J., Bruckmann H., et al. 30 day results from the SPACE trial of stent-protected angioplasty versus carotid endarterectomy in symptomatic patients: a randomised non-inferiority trial. Lancet 368 (2006) 1239-1247
-
(2006)
Lancet
, vol.368
, pp. 1239-1247
-
-
Ringleb, P.A.1
Allenberg, J.2
Bruckmann, H.3
-
2
-
-
33750042277
-
Endarterectomy versus stenting in patients with symptomatic severe carotid stenosis
-
Mas J.L., Chatellier G., Beyssen B., et al. Endarterectomy versus stenting in patients with symptomatic severe carotid stenosis. N Engl J Med 355 (2006) 1660-1671
-
(2006)
N Engl J Med
, vol.355
, pp. 1660-1671
-
-
Mas, J.L.1
Chatellier, G.2
Beyssen, B.3
-
4
-
-
33644818515
-
Efficacy of treatment of severe carotid bifurcation stenosis by using self-expanding stents without deliberate use of angioplasty balloons
-
Lownie S.P., Pelz D.M., Lee D.H., Men S., Gulka I., and Kalapos P. Efficacy of treatment of severe carotid bifurcation stenosis by using self-expanding stents without deliberate use of angioplasty balloons. AJNR Am J Neuroradiol 26 (2005) 1241-1248
-
(2005)
AJNR Am J Neuroradiol
, vol.26
, pp. 1241-1248
-
-
Lownie, S.P.1
Pelz, D.M.2
Lee, D.H.3
Men, S.4
Gulka, I.5
Kalapos, P.6
-
5
-
-
19544385747
-
Protected carotid-artery stenting versus endarterectomy in high-risk patients
-
Yadav J.S., Wholey M.H., Kuntz R.E., et al. Protected carotid-artery stenting versus endarterectomy in high-risk patients. N Engl J Med 351 (2004) 1493-1501
-
(2004)
N Engl J Med
, vol.351
, pp. 1493-1501
-
-
Yadav, J.S.1
Wholey, M.H.2
Kuntz, R.E.3
-
7
-
-
66849099907
-
Hemodynamic instability during carotid artery stenting: the relative contribution of stent deployment versus balloon dilation
-
Bussiere M., Lownie S.P., Lee D., Gulka I., Leung A., and Pelz D.M. Hemodynamic instability during carotid artery stenting: the relative contribution of stent deployment versus balloon dilation. J Neurosurg 110 (2009) 905-912
-
(2009)
J Neurosurg
, vol.110
, pp. 905-912
-
-
Bussiere, M.1
Lownie, S.P.2
Lee, D.3
Gulka, I.4
Leung, A.5
Pelz, D.M.6
-
8
-
-
67650645736
-
Primary stenting for recurrent stenosis following carotid endarterectomy
-
Bussiere M., Pelz D.M., and Lownie S.P. Primary stenting for recurrent stenosis following carotid endarterectomy. Can J Neurol Sci 36 (2009) 332-335
-
(2009)
Can J Neurol Sci
, vol.36
, pp. 332-335
-
-
Bussiere, M.1
Pelz, D.M.2
Lownie, S.P.3
-
9
-
-
67650710825
-
Late stent expansion and neointimal proliferation of oversized nitinol stents in peripheral arteries
-
Zhao H.Q., Nikanorov A., Virmani R., Jones R., Pacheco E., and Schwartz L.B. Late stent expansion and neointimal proliferation of oversized nitinol stents in peripheral arteries. Cardiovasc Intervent Radiol 32 (2009) 720-726
-
(2009)
Cardiovasc Intervent Radiol
, vol.32
, pp. 720-726
-
-
Zhao, H.Q.1
Nikanorov, A.2
Virmani, R.3
Jones, R.4
Pacheco, E.5
Schwartz, L.B.6
-
10
-
-
67349139936
-
Clinical outcomes after percutaneous peripheral intervention for chronic total occlusion of superficial femoral arteries: comparison between self-expandable nitinol stent and stainless steel stent
-
Nakagawa Y., Yajima J., Oikawa Y., et al. Clinical outcomes after percutaneous peripheral intervention for chronic total occlusion of superficial femoral arteries: comparison between self-expandable nitinol stent and stainless steel stent. J Cardiol 53 (2009) 417-421
-
(2009)
J Cardiol
, vol.53
, pp. 417-421
-
-
Nakagawa, Y.1
Yajima, J.2
Oikawa, Y.3
-
11
-
-
69149085296
-
Primary nitinol stenting for femoropopliteal disease
-
Mewissen M.W. Primary nitinol stenting for femoropopliteal disease. J Endovasc Ther 16 (2009) II63-II81
-
(2009)
J Endovasc Ther
, vol.16
-
-
Mewissen, M.W.1
-
12
-
-
65549147675
-
The use of self-expanding stents in coronary bifurcations and beyond: a paradigm revisited
-
Jilaihawi H., Farah B., and Laborde J.C. The use of self-expanding stents in coronary bifurcations and beyond: a paradigm revisited. EuroIntervention 4 (2009) 669-675
-
(2009)
EuroIntervention
, vol.4
, pp. 669-675
-
-
Jilaihawi, H.1
Farah, B.2
Laborde, J.C.3
-
13
-
-
67649277704
-
Measurement of radial and axial forces of biliary self-expandable metallic stents
-
Isayama H., Nakai Y., Toyokawa Y., et al. Measurement of radial and axial forces of biliary self-expandable metallic stents. Gastrointest Endosc 70 (2009) 37-44
-
(2009)
Gastrointest Endosc
, vol.70
, pp. 37-44
-
-
Isayama, H.1
Nakai, Y.2
Toyokawa, Y.3
-
14
-
-
0034082487
-
Physical properties of endovascular stents: an experimental comparison
-
Duda S.H., Wiskirchen J., Tepe G., et al. Physical properties of endovascular stents: an experimental comparison. J Vasc Interv Radiol 11 (2000) 645-654
-
(2000)
J Vasc Interv Radiol
, vol.11
, pp. 645-654
-
-
Duda, S.H.1
Wiskirchen, J.2
Tepe, G.3
-
15
-
-
0034126191
-
Mechanical properties of metallic stents: how do these properties influence the choice of stent for specific lesions?
-
Dyet J.F., Watts W.G., Ettles D.F., and Nicholson A.A. Mechanical properties of metallic stents: how do these properties influence the choice of stent for specific lesions?. Cardiovasc Intervent Radiol 23 (2000) 47-54
-
(2000)
Cardiovasc Intervent Radiol
, vol.23
, pp. 47-54
-
-
Dyet, J.F.1
Watts, W.G.2
Ettles, D.F.3
Nicholson, A.A.4
-
16
-
-
0027567438
-
A study of the geometrical and mechanical properties of a self-expanding metallic stent: theory and experiment
-
Jedwab M.R., and Clerc C.O. A study of the geometrical and mechanical properties of a self-expanding metallic stent: theory and experiment. J Appl Biomater 4 (1993) 77-85
-
(1993)
J Appl Biomater
, vol.4
, pp. 77-85
-
-
Jedwab, M.R.1
Clerc, C.O.2
-
17
-
-
2442697814
-
Experimental functional analysis of self-expanding stents using a new developed ex vivo model
-
Grenacher L., Ganger E., Lubienski A., Dux M., Kauffmann G.W., and Richter G.M. Experimental functional analysis of self-expanding stents using a new developed ex vivo model. Invest Radiol 39 (2004) 374-383
-
(2004)
Invest Radiol
, vol.39
, pp. 374-383
-
-
Grenacher, L.1
Ganger, E.2
Lubienski, A.3
Dux, M.4
Kauffmann, G.W.5
Richter, G.M.6
-
18
-
-
0028394295
-
Comparison of mechanical deformation properties of metallic stents with use of stress-strain analysis
-
Lossef S.V., Lutz R.J., Mundorf J., and Barth K.H. Comparison of mechanical deformation properties of metallic stents with use of stress-strain analysis. J Vasc Interv Radiol 5 (1994) 341-349
-
(1994)
J Vasc Interv Radiol
, vol.5
, pp. 341-349
-
-
Lossef, S.V.1
Lutz, R.J.2
Mundorf, J.3
Barth, K.H.4
-
19
-
-
0842280666
-
Self-expanding nitinol stents: material and design considerations
-
Stoeckel D., Pelton A., and Duerig T. Self-expanding nitinol stents: material and design considerations. Eur Radiol 14 (2004) 292-301
-
(2004)
Eur Radiol
, vol.14
, pp. 292-301
-
-
Stoeckel, D.1
Pelton, A.2
Duerig, T.3
-
21
-
-
24944472978
-
Carotid artery stenting: which stent for which lesion?
-
Bosiers M., Deloose K., Verbist J., and Peeters P. Carotid artery stenting: which stent for which lesion?. Vascular 13 (2005) 205-210
-
(2005)
Vascular
, vol.13
, pp. 205-210
-
-
Bosiers, M.1
Deloose, K.2
Verbist, J.3
Peeters, P.4
-
22
-
-
0034106765
-
Nitinol properties affecting uses in interventional radiology
-
Rabkin D.J., Lang E.V., and Brophy D.P. Nitinol properties affecting uses in interventional radiology. J Vasc Interv Radiol 11 (2000) 343-350
-
(2000)
J Vasc Interv Radiol
, vol.11
, pp. 343-350
-
-
Rabkin, D.J.1
Lang, E.V.2
Brophy, D.P.3
-
23
-
-
0023921125
-
Elastic characteristics of the self-expanding metallic stents
-
Fallone B.G., Wallace S., and Gianturco C. Elastic characteristics of the self-expanding metallic stents. Invest Radiol 23 (1988) 370-376
-
(1988)
Invest Radiol
, vol.23
, pp. 370-376
-
-
Fallone, B.G.1
Wallace, S.2
Gianturco, C.3
-
24
-
-
0026332555
-
Study of the physical properties of expandable metallic stents
-
Sawada S., Saito S., Kotani K., et al. Study of the physical properties of expandable metallic stents. Radiat Med 9 (1991) 213-216
-
(1991)
Radiat Med
, vol.9
, pp. 213-216
-
-
Sawada, S.1
Saito, S.2
Kotani, K.3
-
25
-
-
0026447482
-
Deformation characteristics of a bioabsorbable intravascular stent
-
Agrawal C.M., and Clark H.G. Deformation characteristics of a bioabsorbable intravascular stent. Invest Radiol 27 (1992) 1020-1024
-
(1992)
Invest Radiol
, vol.27
, pp. 1020-1024
-
-
Agrawal, C.M.1
Clark, H.G.2
-
26
-
-
36348998124
-
A quality assurance phantom for the performance evaluation of volumetric micro-CT systems
-
Du L.Y., Umoh J., Nikolov H.N., Pollmann S.I., Lee T.Y., and Holdsworth D.W. A quality assurance phantom for the performance evaluation of volumetric micro-CT systems. Phys Med Biol 52 (2007) 7087-7108
-
(2007)
Phys Med Biol
, vol.52
, pp. 7087-7108
-
-
Du, L.Y.1
Umoh, J.2
Nikolov, H.N.3
Pollmann, S.I.4
Lee, T.Y.5
Holdsworth, D.W.6
-
27
-
-
33846189786
-
Fast retrospectively gated quantitative four-dimensional (4D) cardiac micro computed tomography imaging of free-breathing mice
-
Drangova M., Ford N.L., Detombe S.A., Wheatley A.R., and Holdsworth D.W. Fast retrospectively gated quantitative four-dimensional (4D) cardiac micro computed tomography imaging of free-breathing mice. Invest Radiol 42 (2007) 85-94
-
(2007)
Invest Radiol
, vol.42
, pp. 85-94
-
-
Drangova, M.1
Ford, N.L.2
Detombe, S.A.3
Wheatley, A.R.4
Holdsworth, D.W.5
-
28
-
-
34748848729
-
Optimization of a retrospective technique for respiratory-gated high speed micro-CT of free-breathing rodents
-
Ford N.L., Wheatley A.R., Holdsworth D.W., and Drangova M. Optimization of a retrospective technique for respiratory-gated high speed micro-CT of free-breathing rodents. Phys Med Biol 52 (2007) 5749-5769
-
(2007)
Phys Med Biol
, vol.52
, pp. 5749-5769
-
-
Ford, N.L.1
Wheatley, A.R.2
Holdsworth, D.W.3
Drangova, M.4
-
29
-
-
38149061404
-
Noninvasive quantification of tumor volume in preclinical liver metastasis models using contrast-enhanced x-ray computed tomography
-
Graham K.C., Ford N.L., Mackenzie L.T., et al. Noninvasive quantification of tumor volume in preclinical liver metastasis models using contrast-enhanced x-ray computed tomography. Invest Radiol 43 (2008) 92-99
-
(2008)
Invest Radiol
, vol.43
, pp. 92-99
-
-
Graham, K.C.1
Ford, N.L.2
Mackenzie, L.T.3
-
30
-
-
0036096175
-
Radial force and wall apposition of balloon-expandable vascular stents in eccentric stenoses: an in vitro evaluation in a curved vessel model
-
Kalmar G., Hubner F., Voelker W., et al. Radial force and wall apposition of balloon-expandable vascular stents in eccentric stenoses: an in vitro evaluation in a curved vessel model. J Vasc Interv Radiol 13 (2002) 499-508
-
(2002)
J Vasc Interv Radiol
, vol.13
, pp. 499-508
-
-
Kalmar, G.1
Hubner, F.2
Voelker, W.3
-
31
-
-
33644909898
-
64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents
-
Maintz D., Seifarth H., Raupach R., et al. 64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents. Eur Radiol 16 (2006) 818-826
-
(2006)
Eur Radiol
, vol.16
, pp. 818-826
-
-
Maintz, D.1
Seifarth, H.2
Raupach, R.3
-
32
-
-
0035660731
-
Multislice CT angiography of the iliac arteries in the presence of various stents: in vitro evaluation of artifacts and lumen visibility
-
Maintz D., Fischbach R., Juergens K.U., Allkemper T., Wessling J., and Heindel W. Multislice CT angiography of the iliac arteries in the presence of various stents: in vitro evaluation of artifacts and lumen visibility. Invest Radiol 36 (2001) 699-704
-
(2001)
Invest Radiol
, vol.36
, pp. 699-704
-
-
Maintz, D.1
Fischbach, R.2
Juergens, K.U.3
Allkemper, T.4
Wessling, J.5
Heindel, W.6
-
33
-
-
0042172955
-
Theoretical and experimental evaluation of the radial force of self-expanding braided bioabsorbable stents
-
Nuutinen J.P., Clerc C., and Tormala P. Theoretical and experimental evaluation of the radial force of self-expanding braided bioabsorbable stents. J Biomater Sci Polym Ed 14 (2003) 677-687
-
(2003)
J Biomater Sci Polym Ed
, vol.14
, pp. 677-687
-
-
Nuutinen, J.P.1
Clerc, C.2
Tormala, P.3
|