메뉴 건너뛰기




Volumn 11, Issue 3, 2000, Pages 343-350

Nitinol properties affecting uses in interventional radiology

Author keywords

[No Author keywords available]

Indexed keywords

ALLOY; NICKEL; TITANIUM;

EID: 0034106765     PISSN: 10510443     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1051-0443(07)61428-6     Document Type: Article
Times cited : (25)

References (19)
  • 1
    • 0018328839 scopus 로고
    • Shape memory alloys
    • Schetky LM. Shape memory alloys. Sci Am 1979; 241:74-83.
    • (1979) Sci Am , vol.241 , pp. 74-83
    • Schetky, L.M.1
  • 2
    • 0343850672 scopus 로고
    • Unusual properties of usual metals
    • Zaimovsky VA, Kolupaeva TL. Unusual properties of usual metals [in Russian]. Science 1984; 111-113.
    • (1984) Science , pp. 111-113
    • Zaimovsky, V.A.1    Kolupaeva, T.L.2
  • 3
    • 0000966996 scopus 로고
    • About a thermoelastic balance in martensite transformations
    • Kurdiumov GV, Khandros LG. About a thermoelastic balance in martensite transformations [in Russian]. Rep Acad Sci USSR 1949; 66:2: 211-215.
    • (1949) Rep Acad Sci USSR , vol.66 , Issue.2 , pp. 211-215
    • Kurdiumov, G.V.1    Khandros, L.G.2
  • 4
    • 49949123492 scopus 로고
    • A summary of recent research on the nitinol alloys and their potential application in ocean engineering
    • Buehler WJ, Wang FE. A summary of recent research on the nitinol alloys and their potential application in ocean engineering. Ocean Eng 1968; 1:105-120.
    • (1968) Ocean Eng , vol.1 , pp. 105-120
    • Buehler, W.J.1    Wang, F.E.2
  • 5
    • 0017015723 scopus 로고
    • Using the shape recovery of nitinol in the Harrington rod treatment of scoliosis
    • Shmerling MA, Wilkov MA, Sanders AE, Woosley JE. Using the shape recovery of nitinol in the Harrington rod treatment of scoliosis. J Biomed Mater Res 1976; 10:879-892.
    • (1976) J Biomed Mater Res , vol.10 , pp. 879-892
    • Shmerling, M.A.1    Wilkov, M.A.2    Sanders, A.E.3    Woosley, J.E.4
  • 6
    • 0019031792 scopus 로고
    • Some applications of shape memory alloys
    • Wayman CM. Some applications of shape memory alloys. J Metals 1980; 32:129-137.
    • (1980) J Metals , vol.32 , pp. 129-137
    • Wayman, C.M.1
  • 9
    • 0000359641 scopus 로고
    • Corrosion and biocompatibility of shape memory alloys
    • Oshida Y, Miyazaki S. Corrosion and biocompatibility of shape memory alloys. Corrosion Eng 1991; 40: 1009-1025.
    • (1991) Corrosion Eng , vol.40 , pp. 1009-1025
    • Oshida, Y.1    Miyazaki, S.2
  • 10
    • 0020662671 scopus 로고
    • Potential toxicity from nickel contamination of intravenous fluids
    • Sunderman FW. Potential toxicity from nickel contamination of intravenous fluids. Ann Clin Lab Sci 1983; 13:1-4.
    • (1983) Ann Clin Lab Sci , vol.13 , pp. 1-4
    • Sunderman, F.W.1
  • 13
    • 0030340747 scopus 로고    scopus 로고
    • On the nature of the biocompatibility and on medical applications on NiTi shape memory and superelastic alloys
    • Shabalovskaya SA. On the nature of the biocompatibility and on medical applications on NiTi shape memory and superelastic alloys. Biomed Mater Eng 1996; 6:267-289.
    • (1996) Biomed Mater Eng , vol.6 , pp. 267-289
    • Shabalovskaya, S.A.1
  • 14
    • 84939677652 scopus 로고
    • Comparative cell culture effects of shape memory metal (Nitinol), nickel and titanium: A biocompatibility estimation
    • Putters JL, Kaulesar Sukul DM, De Zeeuw GR, Bijma A, Besselink PA. Comparative cell culture effects of shape memory metal (Nitinol), nickel and titanium: a biocompatibility estimation. Eur Surg Res 1992; 24:378-382.
    • (1992) Eur Surg Res , vol.24 , pp. 378-382
    • Putters, J.L.1    Kaulesar Sukul, D.M.2    De Zeeuw, G.R.3    Bijma, A.4    Besselink, P.A.5
  • 16
    • 0033046719 scopus 로고    scopus 로고
    • Effects of nitinol strecker stent placement on vascular response in normal and stenotic porcine iliac arteries
    • Froelich JJ, Alfke H, Wilke A, et al. Effects of nitinol Strecker stent placement on vascular response in normal and stenotic porcine iliac arteries. JVIR 1999; 10:329-338.
    • (1999) JVIR , vol.10 , pp. 329-338
    • Froelich, J.J.1    Alfke, H.2    Wilke, A.3
  • 17
    • 0029957458 scopus 로고    scopus 로고
    • Are self-expanding stents superior to balloon-expanded in dilating aortas? An experimental study in pigs
    • Mangell P, Malina M, Vogt K, et al. Are self-expanding stents superior to balloon-expanded in dilating aortas? An experimental study in pigs. Eur J Endovasc Surg 1996; 12:287-294.
    • (1996) Eur J Endovasc Surg , vol.12 , pp. 287-294
    • Mangell, P.1    Malina, M.2    Vogt, K.3
  • 18
    • 0030220711 scopus 로고    scopus 로고
    • Short and long-term clinical and quantitative angiographic results with the new, less shortening Wallstent for vessel reconstruction in chronic total occlusion: A quantitative angiographic study
    • Ozaki Y, Violaris AG, Hamburger J, et al. Short and long-term clinical and quantitative angiographic results with the new, less shortening Wallstent for vessel reconstruction in chronic total occlusion: a quantitative angiographic study. JACC 1996; 28:354-360.
    • (1996) JACC , vol.28 , pp. 354-360
    • Ozaki, Y.1    Violaris, A.G.2    Hamburger, J.3
  • 19
    • 0026514037 scopus 로고
    • Effects of design geometry of intravascular endoprostheses on stenosis rate in normal rabbits
    • Tominaga R, Kambic H, Emoto H, Harasaki H, Sutton C, Hollman J. Effects of design geometry of intravascular endoprostheses on stenosis rate in normal rabbits. Am Heart J 1992; 123:21-28.
    • (1992) Am Heart J , vol.123 , pp. 21-28
    • Tominaga, R.1    Kambic, H.2    Emoto, H.3    Harasaki, H.4    Sutton, C.5    Hollman, J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.