-
1
-
-
0026008513
-
Intravascular stents. General principles and status of lower-extremity arterial applications
-
Becker GJ. Intravascular stents. General principles and status of lower-extremity arterial applications. Circulation. 1991;83(suppl 1):122-136.
-
(1991)
Circulation
, vol.83
, Issue.SUPPL. 1
, pp. 122-136
-
-
Becker, G.J.1
-
2
-
-
0034082487
-
Physical properties of endovascular stents: An experimental comparison
-
Duda SH, Wiskirchen J, Tepe G, et al. Physical properties of endovascular stents: an experimental comparison. J Vasc Interv Radiol. 2000; 11:645-654.
-
(2000)
J Vasc Interv Radiol
, vol.11
, pp. 645-654
-
-
Duda, S.H.1
Wiskirchen, J.2
Tepe, G.3
-
3
-
-
0034126191
-
Mechanical properties of metallic stents: How do these properties influence the choice of stent for specific lesions?
-
Dyet JF, Watts WG, Ettles DF, et al. Mechanical properties of metallic stents: how do these properties influence the choice of stent for specific lesions? Cardiovasc Intervent Radiol. 2000;23:47-54.
-
(2000)
Cardiovasc Intervent Radiol
, vol.23
, pp. 47-54
-
-
Dyet, J.F.1
Watts, W.G.2
Ettles, D.F.3
-
4
-
-
0343465216
-
Limitations of peripheral angioplasty and the role of new devices
-
Rutherford RB, ed. Philadelphia, London, Toronto: Saunders Co.
-
Hodgson KJ. Limitations of peripheral angioplasty and the role of new devices. In: Rutherford RB, ed. Vascular Surgery. Philadelphia, London, Toronto: Saunders Co.; 1995:369-394.
-
(1995)
Vascular Surgery
, pp. 369-394
-
-
Hodgson, K.J.1
-
5
-
-
0035081506
-
Ergebnisse nach memotherm-stent-implantation in becken- und leistenarterien
-
Manke C, Hackethal S, Müller-Hülsbeck S, et al. Ergebnisse nach Memotherm-Stent-Implantation in Becken- und Leistenarterien. Fortschr Röntgenstr 2001;173:240-244.
-
(2001)
Fortschr Röntgenstr
, vol.173
, pp. 240-244
-
-
Manke, C.1
Hackethal, S.2
Müller-Hülsbeck, S.3
-
6
-
-
0034106765
-
Nitinol properties affecting uses in interventional radiology
-
Rabkin DJ, Lang EV, Brophy DP. Nitinol properties affecting uses in interventional radiology. J Vasc Interv Radiol. 2000;11:343-350.
-
(2000)
J Vasc Interv Radiol
, vol.11
, pp. 343-350
-
-
Rabkin, D.J.1
Lang, E.V.2
Brophy, D.P.3
-
8
-
-
0028394295
-
Comparison of mechanical deformation properties of metallic stents with use of stress-strain analysis
-
Lossef SV, Lutz RJ, Mundorf J, et al. Comparison of mechanical deformation properties of metallic stents with use of stress-strain analysis. J Vasc Interv Radiol. 1994;5:341-349.
-
(1994)
J Vasc Interv Radiol
, vol.5
, pp. 341-349
-
-
Lossef, S.V.1
Lutz, R.J.2
Mundorf, J.3
-
9
-
-
0031831503
-
Evaluation of the compressive mechanical properties of endoluminal metal stents
-
Schrader SC, Beyar R. Evaluation of the compressive mechanical properties of endoluminal metal stents. Cathet Cardiovasc Diagn. 1998; 44:179-187.
-
(1998)
Cathet Cardiovasc Diagn
, vol.44
, pp. 179-187
-
-
Schrader, S.C.1
Beyar, R.2
-
10
-
-
0032239502
-
Untersuchungen zu den mechanischen eigenschaften von metallischen gefäßimplantaten (Stents)
-
Schröder B, Dück R, Kopf M. Untersuchungen zu den mechanischen Eigenschaften von metallischen Gefäßimplantaten (Stents). Biomed Tech (Berl). 1998;43(suppl):436-437.
-
(1998)
Biomed Tech (Berl)
, vol.43
, Issue.SUPPL.
, pp. 436-437
-
-
Schröder, B.1
Dück, R.2
Kopf, M.3
-
11
-
-
0029957768
-
Coronary plaque morphology affects stent deployment: Assessment by intracoronary ultrasound
-
Albrecht D, Kaspers S, Füssl R, et al. Coronary plaque morphology affects stent deployment: assessment by intracoronary ultrasound. Cathet Cardiovasc Diagn. 1996;38:229-235.
-
(1996)
Cathet Cardiovasc Diagn
, vol.38
, pp. 229-235
-
-
Albrecht, D.1
Kaspers, S.2
Füssl, R.3
-
12
-
-
0032146975
-
Treatment of calcified coronary lesions with Palmaz-Schatz stents
-
Hoffmann R, Mintz GS, Popma JJ, et al. Treatment of calcified coronary lesions with Palmaz-Schatz stents. Eur Heart J. 1998;19:1224-1231.
-
(1998)
Eur Heart J
, vol.19
, pp. 1224-1231
-
-
Hoffmann, R.1
Mintz, G.S.2
Popma, J.J.3
-
13
-
-
0031772406
-
Evaluation of maximum neointima proliferation and plaque morphology in iliac self-expanding nitinol stents with intravascular sonography
-
Schwarzenberg H, Müller-Hülsbeck S, Glüer CC, et al. Evaluation of maximum neointima proliferation and plaque morphology in iliac self-expanding nitinol stents with intravascular sonography. Am J Roentgenol. 1998;171:1627-1630.
-
(1998)
Am J Roentgenol
, vol.171
, pp. 1627-1630
-
-
Schwarzenberg, H.1
Müller-Hülsbeck, S.2
Glüer, C.C.3
-
14
-
-
0037302902
-
Resistance to hoop stress in balloon expandable stents: Evaluation in an "ex-vivo" model
-
Grenacher L, Deutsch J, Lubienski A, et al. Resistance to hoop stress in balloon expandable stents: evaluation in an "ex-vivo" model. Invest Radiol. 2003;38:65-72.
-
(2003)
Invest Radiol
, vol.38
, pp. 65-72
-
-
Grenacher, L.1
Deutsch, J.2
Lubienski, A.3
-
15
-
-
0026690445
-
Die konservierung ganzer leichen in natürlichen farben
-
Thiel W. Die Konservierung ganzer Leichen in natürlichen Farben. Ann Anat. 1992;174:185-195.
-
(1992)
Ann Anat
, vol.174
, pp. 185-195
-
-
Thiel, W.1
-
16
-
-
0033014247
-
Internal carotid arterial stenosis: CT angiography with volume rendering
-
Leclerc X, Godefroy O, Lucas C, et al. Internal carotid arterial stenosis: CT angiography with volume rendering. Radiology. 1999;210:673-682.
-
(1999)
Radiology
, vol.210
, pp. 673-682
-
-
Leclerc, X.1
Godefroy, O.2
Lucas, C.3
-
17
-
-
0028509627
-
Strength, elasticity, and plasticity of expandable metal stents: In vitro studies with three types of stress
-
Flueckiger F, Sternthal H, Klein GE, et al. Strength, elasticity, and plasticity of expandable metal stents: in vitro studies with three types of stress. J Vasc Interv Radiol. 1994;5:745-750.
-
(1994)
J Vasc Interv Radiol
, vol.5
, pp. 745-750
-
-
Flueckiger, F.1
Sternthal, H.2
Klein, G.E.3
-
18
-
-
0032254477
-
Experimentelle untersuchung der radialen verformbarkeit von stents
-
Schrader SC, Beyar R, Kühler M, et al. Experimentelle Untersuchung der radialen Verformbarkeit von Stents. Biomed Tech (Berl). 1998; 43(suppl):512-513.
-
(1998)
Biomed Tech (Berl)
, vol.43
, Issue.SUPPL.
, pp. 512-513
-
-
Schrader, S.C.1
Beyar, R.2
Kühler, M.3
-
19
-
-
0032996076
-
Effect of stent design on reduction of elastic recoil: A comparison via quantitative intravascular ultrasound
-
Yamamoto Y, Brown DL, Ischinger TA, et al. Effect of stent design on reduction of elastic recoil: a comparison via quantitative intravascular ultrasound. Cathet Cardiovasc Intervent. 1999;47:251-257.
-
(1999)
Cathet Cardiovasc Intervent
, vol.47
, pp. 251-257
-
-
Yamamoto, Y.1
Brown, D.L.2
Ischinger, T.A.3
-
20
-
-
0033011716
-
Radial force of coronary stents: A comparative analysis
-
Rieu R, Barragan P, Masson C, et al. Radial force of coronary stents: a comparative analysis. Cathet Cardiovasc Intervent. 1999;46:380-391.
-
(1999)
Cathet Cardiovasc Intervent
, vol.46
, pp. 380-391
-
-
Rieu, R.1
Barragan, P.2
Masson, C.3
-
21
-
-
0031297586
-
Experimentelle überprüfung des aufweitverhaltens von ballonexpandierbaren koronarstents
-
Schmitz KP, Behrend D, Behrens P, et al. Experimentelle Überprüfung des Aufweitverhaltens von ballonexpandierbaren Koronarstents. Biomed Tech (Berl). 1997;42(suppl):203-204.
-
(1997)
Biomed Tech (Berl)
, vol.42
, Issue.SUPPL.
, pp. 203-204
-
-
Schmitz, K.P.1
Behrend, D.2
Behrens, P.3
-
22
-
-
0032239959
-
Wechselwirkung von radialfestigkeit und flexibilität von koronarstents
-
Schmitz KP, Behrend D, Behrens P, et al. Wechselwirkung von Radialfestigkeit und Flexibilität von Koronarstents. Biomed Tech (Berl). 1998;43(suppl):376-377.
-
(1998)
Biomed Tech (Berl)
, vol.43
, Issue.SUPPL.
, pp. 376-377
-
-
Schmitz, K.P.1
Behrend, D.2
Behrens, P.3
-
23
-
-
0027253852
-
Experimentelle untersuchungen zur druckstabilität vaskulärer endoprothesen
-
Wehrmeyer B, Kuhn FP. Experimentelle Untersuchungen zur Druckstabilität vaskulärer Endoprothesen. Fortschr Röntgenstr. 1993;158:242-246.
-
(1993)
Fortschr Röntgenstr
, vol.158
, pp. 242-246
-
-
Wehrmeyer, B.1
Kuhn, F.P.2
-
24
-
-
0031303841
-
Quantifizierung des recoils von koronarstents: Eine in-vitro-untersuchung an koronarstenosemodellen mittels hochauflösender röntgentechnik
-
Pörner T, Voelker W, Teubner J, et al. Quantifizierung des Recoils von Koronarstents: eine in-vitro-Untersuchung an Koronarstenosemodellen mittels hochauflösender Röntgentechnik. Biomed Tech (Berl). 1997; 42(suppl):205-206.
-
(1997)
Biomed Tech (Berl)
, vol.42
, Issue.SUPPL.
, pp. 205-206
-
-
Pörner, T.1
Voelker, W.2
Teubner, J.3
-
25
-
-
0024564546
-
Self-expanding endovascular stent in experimental atherosclerosis
-
Rousseau H, Joffre F, Raillat C, et al. Self-expanding endovascular stent in experimental atherosclerosis. Radiology. 1989;170:773-778.
-
(1989)
Radiology
, vol.170
, pp. 773-778
-
-
Rousseau, H.1
Joffre, F.2
Raillat, C.3
-
26
-
-
0035118823
-
Changes in wall mechanics after endovascular stenting in the rabbit aorta comparison of three stent designs
-
Vernhet H, Demaria R, Juan JM, et al. Changes in wall mechanics after endovascular stenting in the rabbit aorta comparison of three stent designs. Am J Roentgenol. 2000;176:803-807.
-
(2000)
Am J Roentgenol
, vol.176
, pp. 803-807
-
-
Vernhet, H.1
Demaria, R.2
Juan, J.M.3
-
27
-
-
0033578471
-
In vivo assessment of stent expansion and recoil in normal porcine coronary arteries, differential outcome by stent design
-
Carrozza JP Jr., Hosley SE, Cohen DJ, et al. In vivo assessment of stent expansion and recoil in normal porcine coronary arteries, differential outcome by stent design. Circulation. 1999;100:756-760.
-
(1999)
Circulation
, vol.100
, pp. 756-760
-
-
Carrozza Jr., J.P.1
Hosley, S.E.2
Cohen, D.J.3
-
28
-
-
0027996127
-
Self-expandable and highly flexible nitinol stent: Immediate and long-term results in dogs
-
Grenadier E, Shofti R, Beyar M, et al. Self-expandable and highly flexible nitinol stent: immediate and long-term results in dogs. Am Heart J. 1994;128:870-878.
-
(1994)
Am Heart J
, vol.128
, pp. 870-878
-
-
Grenadier, E.1
Shofti, R.2
Beyar, M.3
-
29
-
-
0022518164
-
Atherosclerotic rabbit aortas: Expandable intraluminal grafting
-
Palmaz JC, Windeler SA, Garcia F, et al. Atherosclerotic rabbit aortas: expandable intraluminal grafting. Radiology. 1986;160:723-726.
-
(1986)
Radiology
, vol.160
, pp. 723-726
-
-
Palmaz, J.C.1
Windeler, S.A.2
Garcia, F.3
-
31
-
-
0032972020
-
Differences in endothelial injury after balloon angioplasty, insertion of balloon-expanded stents or release of self-expanding stents: An electron microscopic experimental study
-
Harnek J, Zoucas E, Carlemalm E, et al. Differences in endothelial injury after balloon angioplasty, insertion of balloon-expanded stents or release of self-expanding stents: an electron microscopic experimental study. Cardiovasc Intervent Radiol. 1999;22:56-61.
-
(1999)
Cardiovasc Intervent Radiol
, vol.22
, pp. 56-61
-
-
Harnek, J.1
Zoucas, E.2
Carlemalm, E.3
-
32
-
-
0029739551
-
Subacute thrombosis and vascular injury resulting from slotted-tube nitinol and stainless steel stents in a rabbit carotid artery model
-
Sheth S, Litvack F, Dev V, et al. Subacute thrombosis and vascular injury resulting from slotted-tube nitinol and stainless steel stents in a rabbit carotid artery model. Circulation. 1996;94:1733-1740.
-
(1996)
Circulation
, vol.94
, pp. 1733-1740
-
-
Sheth, S.1
Litvack, F.2
Dev, V.3
-
34
-
-
0344603596
-
Stent placement versus percutaneous transluminal angioplasty of human carotid arteries in cadavers in situ: Distal embolization and findings at intravascular us, mr imaging, and histopathologic analysis
-
Manninen HI, Räsänen HT, Vanninen RL, et al. Stent placement versus percutaneous transluminal angioplasty of human carotid arteries in cadavers in situ: distal embolization and findings at intravascular us, mr imaging, and histopathologic analysis. Radiology. 1999;212:483-492.
-
(1999)
Radiology
, vol.212
, pp. 483-492
-
-
Manninen, H.I.1
Räsänen, H.T.2
Vanninen, R.L.3
-
35
-
-
2442695229
-
Balloon expandable intravascular stents in diseased human cadaver coronary arteries
-
Schatz RA, Tio FO, Palmaz JC. Balloon expandable intravascular stents in diseased human cadaver coronary arteries. Circulation. 1987;76(suppl 4):4-26.
-
(1987)
Circulation
, vol.76
, Issue.SUPPL. 4
, pp. 4-26
-
-
Schatz, R.A.1
Tio, F.O.2
Palmaz, J.C.3
-
36
-
-
0023875003
-
Balloon-expandable intravascular Stent
-
Palmaz JC. Balloon-expandable intravascular Stent. Am J Roentgenol. 1988;150:1263-1269.
-
(1988)
Am J Roentgenol
, vol.150
, pp. 1263-1269
-
-
Palmaz, J.C.1
-
37
-
-
85047679181
-
Non-invasive assessment of the age related changes in stiffness of major branches of the human arteries
-
Kawasaki T, Sasayama S, Yagi SI, et al. Non-invasive assessment of the age related changes in stiffness of major branches of the human arteries. Cardiovasc Res. 1987;21:678-687.
-
(1987)
Cardiovasc Res
, vol.21
, pp. 678-687
-
-
Kawasaki, T.1
Sasayama, S.2
Yagi, S.I.3
-
38
-
-
0029558608
-
Morphologic change in rabbit femoral arteries induced by storage at four degrees celsius and by subsequent reperfusion
-
Crowe D, O'Loughlin K, Knox L, et al. Morphologic change in rabbit femoral arteries induced by storage at four degrees Celsius and by subsequent reperfusion. J Vasc Surg. 1995;22:769-779.
-
(1995)
J Vasc Surg
, vol.22
, pp. 769-779
-
-
Crowe, D.1
O'Loughlin, K.2
Knox, L.3
|