메뉴 건너뛰기




Volumn 4, Issue 5, 2009, Pages 669-675

The use of self-expanding stents in coronary bifurcations and beyond: A paradigm revisited

Author keywords

Angioplasty; Bifurcations; Complex lesions; Stent designs

Indexed keywords

CORONARY ARTERY DISEASE; HISTORY; HUMAN; INSTRUMENTATION; PATHOLOGY; PROSTHESIS; REVIEW; STENT; TRANSLUMINAL CORONARY ANGIOPLASTY; TREATMENT OUTCOME;

EID: 65549147675     PISSN: 1774024X     EISSN: 19696213     Source Type: Journal    
DOI: 10.4244/EIJV4I5A111     Document Type: Review
Times cited : (12)

References (42)
  • 5
    • 33750063193 scopus 로고    scopus 로고
    • Acute and long-term results of bifurcation stenting (from the Coroflex Registry)
    • BISCOR Investigators. Nov 1
    • Rux S, Sonntag S, Schulze R, Rau M, Weber F, Mühling H, Cioppa A, Kleber FX; BISCOR Investigators. Acute and long-term results of bifurcation stenting (from the Coroflex Registry). Am J Cardiol. 2006 Nov 1;98(9): 1214-7.
    • (2006) Am J Cardiol. , vol.98 , Issue.9 , pp. 1214-1217
    • Rux, S.1    Sonntag, S.2    Schulze, R.3    Rau, M.4    Weber, F.5    Mühling, H.6    Cioppa, A.7    Kleber, F.X.8
  • 6
    • 32544435637 scopus 로고    scopus 로고
    • Acute and long-term outcomes of the novel side access (SLK-View) stent for bifurcation coronary lesions: A multicenter nonrandomized feasibility study
    • Feb;
    • Ikeno F, Kim YH, Luna J, Condado JA, Colombo A, Grube E, Fitzgerald PJ, Park SJ, Yeung AC. Acute and long-term outcomes of the novel side access (SLK-View) stent for bifurcation coronary lesions: a multicenter nonrandomized feasibility study. Catheter Cardiovasc Interv. 2006 Feb;67(2): 198-206.
    • (2006) Catheter Cardiovasc Interv. , vol.67 , Issue.2 , pp. 198-206
    • Ikeno, F.1    Kim, Y.H.2    Luna, J.3    Condado, J.A.4    Colombo, A.5    Grube, E.6    Fitzgerald, P.J.7    Park, S.J.8    Yeung, A.C.9
  • 12
    • 84875150325 scopus 로고    scopus 로고
    • Minvasys-Nile PAX: The true dedicated bifurcation abluminal polymer free drug-eluting stent
    • Martin I. Minvasys-Nile PAX: the true dedicated bifurcation abluminal polymer free drug-eluting stent. EuroPCR 2008.
    • (2008) EuroPCR
    • Martin, I.1
  • 14
    • 33645784394 scopus 로고    scopus 로고
    • Long-term histopathologic and IVUS evaluations of a novel coiled sheet stent in porcine carotid arteries
    • May- Jun;
    • Kaneda H, Ikeno F, Lyons J, Rezaee M, Yeung AC, Fitzgerald PJ. Long-term histopathologic and IVUS evaluations of a novel coiled sheet stent in porcine carotid arteries. Cardiovasc Intervent Radiol. 2006 May- Jun;29(3): 413-9.
    • (2006) Cardiovasc Intervent Radiol. , vol.29 , Issue.3 , pp. 413-419
    • Kaneda, H.1    Ikeno, F.2    Lyons, J.3    Rezaee, M.4    Yeung, A.C.5    Fitzgerald, P.J.6
  • 16
    • 34547629821 scopus 로고    scopus 로고
    • Bifurcation Stenting with A Dedicated Biolimus-eluting Stent: X-ray Visual Enhancement of the Final Angiographic Result with "stentBoost Subtract"
    • Agostoni P, Verheye S. Bifurcation stenting with a dedicated biolimus-eluting stent: X-ray visual enhancement of the final angiographic result with "StentBoost Subtract". Cathet Cardiovasc Intervent 2007;70: 233-236.
    • (2007) Cathet Cardiovasc Intervent , vol.70 , pp. 233-236
    • Agostoni, P.1    Verheye, S.2
  • 18
    • 84875142312 scopus 로고    scopus 로고
    • http://www.tctmd.com/txshow.aspx?tid=2628&id=70670&trid=292.
  • 19
    • 60649110480 scopus 로고    scopus 로고
    • Analysis of left main coronary artery bifurcation lesions treated with biolimus-eluting DEVAX AXXESS plus nitinol self-expanding stent: Intravascular ultrasound results of the AXXENT trial
    • Jan 1
    • Hasegawa T, Ako J, Koo BK, Miyazawa A, Sakurai R, Chang H, Dens J, Verheye S, Grube E, Honda Y, Fitzgerald PJ. Analysis of left main coronary artery bifurcation lesions treated with biolimus-eluting DEVAX AXXESS plus nitinol self-expanding stent: intravascular ultrasound results of the AXXENT trial. Catheter Cardiovasc Interv. 2009 Jan 1;73(1): 34-41.
    • (2009) Catheter Cardiovasc Interv. , vol.73 , Issue.1 , pp. 34-41
    • Hasegawa, T.1    Ako, J.2    Koo, B.K.3    Miyazawa, A.4    Sakurai, R.5    Chang, H.6    Dens, J.7    Verheye, S.8    Grube, E.9    Honda, Y.10    Fitzgerald, P.J.11
  • 21
    • 84875127906 scopus 로고    scopus 로고
    • Novel self-expanding stent system for enhanced provisional bifurcation stenting: Examination by StentBoost and intravascular ultrasound
    • Oct27 [Epub ahead of print]
    • Agostoni P, Verheye S. Novel self-expanding stent system for enhanced provisional bifurcation stenting: examination by StentBoost and intravascular ultrasound. Cathet Cardiovasc Intervent 2008 Oct27 [Epub ahead of print].
    • (2008) Cathet Cardiovasc Intervent
    • Agostoni, P.1    Verheye, S.2
  • 25
    • 35348893158 scopus 로고    scopus 로고
    • The CardioMind coronary stent delivery system: Stent delivery on a 0.014 wire
    • Abizaid A, Costa Junior J, Whitbourn R, Chang J. The CardioMind coronary stent delivery system: stent delivery on a 0.014" wire. EuroInterv. 2007;3: 154-157.
    • (2007) EuroInterv. , vol.3 , pp. 154-157
    • Abizaid, A.1    Costa Junior, J.2    Whitbourn, R.3    Chang, J.4
  • 27
    • 60649118170 scopus 로고    scopus 로고
    • Step-by-step StentBoost-guided small vessel stenting using the self-expandable sparrow stent-in-wire
    • Jan 1
    • Agostoni P, Verheye S. Step-by-step StentBoost-guided small vessel stenting using the self-expandable sparrow stent-in-wire. Catheter Cardiovasc Interv. 2009 Jan 1;73(1): 78-83.
    • (2009) Catheter Cardiovasc Interv. , vol.73 , Issue.1 , pp. 78-83
    • Agostoni, P.1    Verheye, S.2
  • 30
    • 78751615709 scopus 로고    scopus 로고
    • The vPredictTM Optical Catheter System: Intravascular Raman Spectroscopy
    • Brennan J, Nazemi J, Motz J, Ramcharitar S. The vPredictTM Optical Catheter System: Intravascular Raman Spectroscopy. EuroInterv. 2008;3: 635-638.
    • (2008) EuroInterv. , vol.3 , pp. 635-638
    • Brennan, J.1    Nazemi, J.2    Motz, J.3    Ramcharitar, S.4
  • 32
    • 0018328839 scopus 로고
    • Shape-memory alloys
    • Schotky LM. Shape-memory alloys. Sci Am. 1979;241: 74-83.
    • (1979) Sci Am. , vol.241 , pp. 74-83
    • Schotky, L.M.1
  • 33
  • 35
    • 32044431845 scopus 로고    scopus 로고
    • Coronary-artery stents
    • Feb 2 Review
    • Serruys PW, Kutryk MJ, Ong AT. Coronary-artery stents. N Engl J Med. 2006 Feb 2;354(5): 483-95. Review.
    • (2006) N Engl J Med. , vol.354 , Issue.5 , pp. 483-495
    • Serruys, P.W.1    Kutryk, M.J.2    Ong, A.T.3
  • 36
    • 0023153178 scopus 로고
    • Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty
    • Sigwart U, Puel J, Mirkovitch V, Joffre F, Kappenberger L. Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty. N Engl J Med 1987;316: 701-6.
    • (1987) N Engl J Med , vol.316 , pp. 701-706
    • Sigwart, U.1    Puel, J.2    Mirkovitch, V.3    Joffre, F.4    Kappenberger, L.5
  • 38
    • 0034034071 scopus 로고    scopus 로고
    • Angiographic and clinical outcome of a new selfexpanding intracoronary stent (RADIUS): Results from multicenter experience in Japan
    • Apr;
    • Hirayama A, Kodama K, Adachi T, Nanto S, Ohara T, Tamai H, Kyo E, Isshiki T, Ochiai M. Angiographic and clinical outcome of a new selfexpanding intracoronary stent (RADIUS): results from multicenter experience in Japan. Catheter Cardiovasc Interv. 2000 Apr;49(4): 401-7.
    • (2000) Catheter Cardiovasc Interv. , vol.49 , Issue.4 , pp. 401-407
    • Hirayama, A.1    Kodama, K.2    Adachi, T.3    Nanto, S.4    Ohara, T.5    Tamai, H.6    Kyo, E.7    Isshiki, T.8    Ochiai, M.9
  • 42
    • 0036311948 scopus 로고    scopus 로고
    • Stent design-related coronary artery remodeling and patterns of neointima formation following self-expanding and balloon-expandable stent implantation
    • Aug;
    • König A, Schiele TM, Rieber J, Theisen K, Mudra H, Klauss V. Stent design-related coronary artery remodeling and patterns of neointima formation following self-expanding and balloon-expandable stent implantation. Catheter Cardiovasc Interv. 2002 Aug;56(4): 478-86.
    • (2002) Catheter Cardiovasc Interv. , vol.56 , Issue.4 , pp. 478-486
    • König, A.1    Schiele, T.M.2    Rieber, J.3    Theisen, K.4    Mudra, H.5    Klauss, V.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.