메뉴 건너뛰기




Volumn 8, Issue 1, 2010, Pages 55-60

An ex-vivo model for hypothermic pulsatile perfusion of porcine pancreata: Hemodynamic and morphologic characteristics

Author keywords

Machine perfusion; Pancreas preservation; Pancreas transplant

Indexed keywords

ACINAR CELL; ANIMAL EXPERIMENT; ANIMAL MODEL; ANIMAL TISSUE; ARTICLE; CELL DAMAGE; COLD ISCHEMIA; CONTROLLED STUDY; CRYOPRESERVATION; EDEMA; ENGRAFTMENT; HEMODYNAMICS; HISTOPATHOLOGY; HYPOTHERMIC MACHINE PERFUSION; INDUCED HYPOTHERMIA; INFLAMMATION; ISCHEMIA; NONHUMAN; ORGAN WEIGHT; PANCREAS ISLET; PANCREAS ISLET CELL; PANCREAS PERFUSION; PANCREAS TRANSPLANTATION; PERFUSION; PERFUSION PRESSURE; SCORING SYSTEM; SYSTOLIC BLOOD PRESSURE; TEMPERATURE SENSITIVITY;

EID: 77749340803     PISSN: 13040855     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (40)

References (21)
  • 1
    • 77749234254 scopus 로고    scopus 로고
    • Pancreas Preservation
    • Hakim N, Stratta R, Gray D, eds, Oxford: Oxford University Press;
    • Spiegel HU, Palmes D. Pancreas Preservation. In: Hakim N, Stratta R, Gray D, eds. Pancreas and Islet Transplantation. Oxford: Oxford University Press; 2000:95-114.
    • (2000) Pancreas and Islet Transplantation , pp. 95-114
    • Spiegel, H.U.1    Palmes, D.2
  • 2
    • 33750618540 scopus 로고    scopus 로고
    • Lipid peroxidation in ischemia-reperfusion oxidative injury of the graft preserved in Celsior and University of Wisconsin solutions on a pig pancreas transplantation model
    • Garcia-Gil FA, Gonzalvo E, Garcia-Garcia JJ, et al. Lipid peroxidation in ischemia-reperfusion oxidative injury of the graft preserved in Celsior and University of Wisconsin solutions on a pig pancreas transplantation model. Transplant Proc. 2006;38(8):2595-2599.
    • (2006) Transplant Proc , vol.38 , Issue.8 , pp. 2595-2599
    • Garcia-Gil, F.A.1    Gonzalvo, E.2    Garcia-Garcia, J.J.3
  • 4
    • 0027434931 scopus 로고
    • Incidence, management and significance of surgical complications after pancreatic transplantation
    • Douzdjian V, Abecassis MM, Cooper JL, Smith JL, Corry RJ. Incidence, management and significance of surgical complications after pancreatic transplantation. Surg Gynecol Obstet. 1993;177(5):451-456.
    • (1993) Surg Gynecol Obstet , vol.177 , Issue.5 , pp. 451-456
    • Douzdjian, V.1    Abecassis, M.M.2    Cooper, J.L.3    Smith, J.L.4    Corry, R.J.5
  • 5
    • 0027426897 scopus 로고
    • Risk factors for postimplantation pancreatitis and pancreatic thrombosis in pancreas transplant recipients
    • Grewal HP, Garland L, Novak K, Gaber L, Tolley EA, Gaber AO. Risk factors for postimplantation pancreatitis and pancreatic thrombosis in pancreas transplant recipients. Transplantation. 1993;56(3):609-612.
    • (1993) Transplantation , vol.56 , Issue.3 , pp. 609-612
    • Grewal, H.P.1    Garland, L.2    Novak, K.3    Gaber, L.4    Tolley, E.A.5    Gaber, A.O.6
  • 6
    • 0027219134 scopus 로고
    • Prevention of early postoperative graft thrombosis in pancreatic transplantation
    • Hopt UT, Büsing M, Schareck W, et al. Prevention of early postoperative graft thrombosis in pancreatic transplantation. Transplant Proc. 1993;25(4):2607-2608.
    • (1993) Transplant Proc , vol.25 , Issue.4 , pp. 2607-2608
    • Hopt, U.T.1    Büsing, M.2    Schareck, W.3
  • 7
    • 0030008182 scopus 로고    scopus 로고
    • Vascular graft thrombosis after pancreatic transplantation: Univariate and multivariate operative and nonoperative risk factor analysis
    • Troppmann C, Gruessner AC, Benedetti E, et al. Vascular graft thrombosis after pancreatic transplantation: univariate and multivariate operative and nonoperative risk factor analysis. J Am Coll Surg. 1996;182(4):285-316.
    • (1996) J Am Coll Surg , vol.182 , Issue.4 , pp. 285-316
    • Troppmann, C.1    Gruessner, A.C.2    Benedetti, E.3
  • 9
    • 0025271323 scopus 로고
    • Pancreatic allograft thrombosis: Donor and retrieval factors and early postperfusion graft function
    • Wright FH, Wright C, Ames SA, Smith JL, Corry RJ. Pancreatic allograft thrombosis: donor and retrieval factors and early postperfusion graft function. Transplant Proc. 1990;22(2):439-441.
    • (1990) Transplant Proc , vol.22 , Issue.2 , pp. 439-441
    • Wright, F.H.1    Wright, C.2    Ames, S.A.3    Smith, J.L.4    Corry, R.J.5
  • 10
    • 29544440699 scopus 로고    scopus 로고
    • Incidence of pancreas graft thrombosis in portoiliac and portocaval venous anastomosis
    • Jiménez C, Manrique A, Herrero ML, et al. Incidence of pancreas graft thrombosis in portoiliac and portocaval venous anastomosis. Transplant Proc. 2005;37(9):3977-3978.
    • (2005) Transplant Proc , vol.37 , Issue.9 , pp. 3977-3978
    • Jiménez, C.1    Manrique, A.2    Herrero, M.L.3
  • 12
    • 58249089430 scopus 로고    scopus 로고
    • Machine perfusion or cold storage in deceased-donor kidney transplantation
    • Moers C, Smits JM, Maathuis MH, et al. Machine perfusion or cold storage in deceased-donor kidney transplantation. N Engl J Med. 2009;360(1):7-19.
    • (2009) N Engl J Med , vol.360 , Issue.1 , pp. 7-19
    • Moers, C.1    Smits, J.M.2    Maathuis, M.H.3
  • 13
    • 40949149520 scopus 로고    scopus 로고
    • Twenty-four hour hypothermic machine perfusion preservation of porcine pancreas facilitates processing for islet isolation
    • Taylor MJ, Baicu S, Leman B, Greene E, Vazquez A, Brassil J. Twenty-four hour hypothermic machine perfusion preservation of porcine pancreas facilitates processing for islet isolation. Transplant Proc. 2008;40(2):480-482.
    • (2008) Transplant Proc , vol.40 , Issue.2 , pp. 480-482
    • Taylor, M.J.1    Baicu, S.2    Leman, B.3    Greene, E.4    Vazquez, A.5    Brassil, J.6
  • 14
    • 77249116508 scopus 로고    scopus 로고
    • Current state of hypothermic machine perfusion preservation of organs: The clinical perspective
    • Oct 24, Epub ahead of print
    • Taylor MJ, Baicu SC. Current state of hypothermic machine perfusion preservation of organs: The clinical perspective. Cryobiology. 2009 Oct 24. [Epub ahead of print]
    • (2009) Cryobiology
    • Taylor, M.J.1    Baicu, S.C.2
  • 16
    • 0042693018 scopus 로고    scopus 로고
    • Experiences learned in the successful establishment of a nonheart beating donor program for renal transplantation
    • Talbot D, Shenton BK, Buckley PE, Gok MA. Experiences learned in the successful establishment of a nonheart beating donor program for renal transplantation. J Urol. 2003;170(4 Pt 1):1088-1092.
    • (2003) J Urol , vol.170 , Issue.4 PART 1 , pp. 1088-1092
    • Talbot, D.1    Shenton, B.K.2    Buckley, P.E.3    Gok, M.A.4
  • 17
    • 4143101420 scopus 로고    scopus 로고
    • A comparison of renal preservation by cold storage and machine perfusion using a porcine autotransplant model
    • Nicholson ML, Hosgood SA, Metcalfe MS, Waller JR, Brook NR. A comparison of renal preservation by cold storage and machine perfusion using a porcine autotransplant model. Transplantation. 2004;78(3):333-337.
    • (2004) Transplantation , vol.78 , Issue.3 , pp. 333-337
    • Nicholson, M.L.1    Hosgood, S.A.2    Metcalfe, M.S.3    Waller, J.R.4    Brook, N.R.5
  • 18
    • 0030056816 scopus 로고    scopus 로고
    • Immediate function and cost comparison between static and pulsatile preservation in kidney recipients
    • Light JA, Gage F, Kowalski AE, Sasaki TM, Callender CO. Immediate function and cost comparison between static and pulsatile preservation in kidney recipients. Clin Transplant. 1996;10(3):233-236.
    • (1996) Clin Transplant , vol.10 , Issue.3 , pp. 233-236
    • Light, J.A.1    Gage, F.2    Kowalski, A.E.3    Sasaki, T.M.4    Callender, C.O.5
  • 21
    • 33847194659 scopus 로고    scopus 로고
    • 't Hart NA, der van Plaats A, Leuvenink HG, et al. Determination of an adequate perfusion pressure for continuous dual vessel hypothermic machine perfusion of the rat liver. Transpl Int. 2007;20(4):343-352.
    • 't Hart NA, der van Plaats A, Leuvenink HG, et al. Determination of an adequate perfusion pressure for continuous dual vessel hypothermic machine perfusion of the rat liver. Transpl Int. 2007;20(4):343-352.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.