메뉴 건너뛰기




Volumn 26, Issue 3, 2010, Pages 316-323

Biomechanical Advantages of Triple-Loaded Suture Anchors Compared With Double-Row Rotator Cuff Repairs

Author keywords

[No Author keywords available]

Indexed keywords

SUTURE MATERIAL; ULTRA HIGH MOLECULAR WEIGHT POLYETHYLENE;

EID: 77549085008     PISSN: 07498063     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arthro.2009.07.019     Document Type: Article
Times cited : (70)

References (34)
  • 1
    • 43049133542 scopus 로고    scopus 로고
    • Failure analysis of rotator cuff repair: A comparison of three double-row techniques
    • Zheng N., Harris H.W., and Andrews J.R. Failure analysis of rotator cuff repair: A comparison of three double-row techniques. J Bone Joint Surg Am 90 (2008) 1034-1042
    • (2008) J Bone Joint Surg Am , vol.90 , pp. 1034-1042
    • Zheng, N.1    Harris, H.W.2    Andrews, J.R.3
  • 2
    • 56449087212 scopus 로고    scopus 로고
    • The results of arthroscopic subscapularis tendon repairs
    • Adams C.R., Schoolfield J.D., and Burkhart S.S. The results of arthroscopic subscapularis tendon repairs. Arthroscopy 24 (2008) 1381-1389
    • (2008) Arthroscopy , vol.24 , pp. 1381-1389
    • Adams, C.R.1    Schoolfield, J.D.2    Burkhart, S.S.3
  • 3
    • 49949083841 scopus 로고    scopus 로고
    • Arthroscopic single-row supraspinatus tendon repair with a modified mattress locking stitch: A prospective, randomized controlled comparison with a simple stitch
    • Ko S.H., Lee C.C., Friedman D., Park K.B., and Warner J.J. Arthroscopic single-row supraspinatus tendon repair with a modified mattress locking stitch: A prospective, randomized controlled comparison with a simple stitch. Arthroscopy 24 (2008) 1005-1012
    • (2008) Arthroscopy , vol.24 , pp. 1005-1012
    • Ko, S.H.1    Lee, C.C.2    Friedman, D.3    Park, K.B.4    Warner, J.J.5
  • 4
    • 43049123163 scopus 로고    scopus 로고
    • Arthroscopic repair of full-thickness tears of the rotator cuff in patients younger than 40 years
    • Krishnan S.G., Harkins D.C., Schiffern S.C., Pennington S.D., and Burkhead W.Z. Arthroscopic repair of full-thickness tears of the rotator cuff in patients younger than 40 years. Arthroscopy 24 (2008) 324-328
    • (2008) Arthroscopy , vol.24 , pp. 324-328
    • Krishnan, S.G.1    Harkins, D.C.2    Schiffern, S.C.3    Pennington, S.D.4    Burkhead, W.Z.5
  • 5
    • 37549064651 scopus 로고    scopus 로고
    • The time for functional recovery after arthroscopic rotator cuff repair: Correlation with tendon healing controlled by computed tomography arthrography
    • Charousset C., Grimberg J., Duranthon L.D., Bellaiche L., Petrover D., and Kalra K. The time for functional recovery after arthroscopic rotator cuff repair: Correlation with tendon healing controlled by computed tomography arthrography. Arthroscopy 24 (2008) 25-33
    • (2008) Arthroscopy , vol.24 , pp. 25-33
    • Charousset, C.1    Grimberg, J.2    Duranthon, L.D.3    Bellaiche, L.4    Petrover, D.5    Kalra, K.6
  • 6
    • 28444453275 scopus 로고    scopus 로고
    • Functional and structural outcome after arthroscopic full-thickness rotator cuff repair: Single-row versus dual-row fixation
    • Sugaya H., Maeda K., Matsuki K., and Moriishi J. Functional and structural outcome after arthroscopic full-thickness rotator cuff repair: Single-row versus dual-row fixation. Arthroscopy 21 (2005) 1307-1316
    • (2005) Arthroscopy , vol.21 , pp. 1307-1316
    • Sugaya, H.1    Maeda, K.2    Matsuki, K.3    Moriishi, J.4
  • 7
    • 33750442166 scopus 로고    scopus 로고
    • The effect of double-row fixation on initial repair strength in rotator cuff repair: A biomechanical study
    • Meier S.W., and Meier J.D. The effect of double-row fixation on initial repair strength in rotator cuff repair: A biomechanical study. Arthroscopy 22 (2006) 1168-1173
    • (2006) Arthroscopy , vol.22 , pp. 1168-1173
    • Meier, S.W.1    Meier, J.D.2
  • 8
    • 32944480447 scopus 로고    scopus 로고
    • Biomechanical comparison of a single-row versus double-row suture anchor technique for rotator cuff repair
    • Kim D.H., Elattrache N.S., Tibone J.E., et al. Biomechanical comparison of a single-row versus double-row suture anchor technique for rotator cuff repair. Am J Sports Med 34 (2006) 407-414
    • (2006) Am J Sports Med , vol.34 , pp. 407-414
    • Kim, D.H.1    Elattrache, N.S.2    Tibone, J.E.3
  • 9
    • 31844453610 scopus 로고    scopus 로고
    • Biomechanical evaluation of arthroscopic rotator cuff repairs: Double-row compared with single-row fixation
    • Ma C.B., Comerford L., Wilson J., and Puttlitz C.M. Biomechanical evaluation of arthroscopic rotator cuff repairs: Double-row compared with single-row fixation. J Bone Joint Surg Am 88 (2006) 403-410
    • (2006) J Bone Joint Surg Am , vol.88 , pp. 403-410
    • Ma, C.B.1    Comerford, L.2    Wilson, J.3    Puttlitz, C.M.4
  • 10
    • 47649124821 scopus 로고    scopus 로고
    • Single-row modified Mason-Allen versus double-row arthroscopic rotator cuff repair: A biomechanical and surface area comparison
    • Nelson C.O., Sileo M.J., Grossman M.G., and Serra-Hsu F. Single-row modified Mason-Allen versus double-row arthroscopic rotator cuff repair: A biomechanical and surface area comparison. Arthroscopy 24 (2008) 941-948
    • (2008) Arthroscopy , vol.24 , pp. 941-948
    • Nelson, C.O.1    Sileo, M.J.2    Grossman, M.G.3    Serra-Hsu, F.4
  • 11
    • 36549000239 scopus 로고    scopus 로고
    • Single-row suture anchor repair of the rotator cuff is biomechanically equivalent to double-row repair in a bovine model
    • Mahar A., Tamborlane J., Oka R., Esch J., and Pedowitz R.A. Single-row suture anchor repair of the rotator cuff is biomechanically equivalent to double-row repair in a bovine model. Arthroscopy 23 (2007) 1265-1270
    • (2007) Arthroscopy , vol.23 , pp. 1265-1270
    • Mahar, A.1    Tamborlane, J.2    Oka, R.3    Esch, J.4    Pedowitz, R.A.5
  • 12
    • 47649117959 scopus 로고    scopus 로고
    • Arthroscopic reduction and fixation with suture-bridge technique for displaced or comminuted greater tuberosity fractures
    • Song H.S., and Williams Jr. G.R. Arthroscopic reduction and fixation with suture-bridge technique for displaced or comminuted greater tuberosity fractures. Arthroscopy 24 (2008) 956-960
    • (2008) Arthroscopy , vol.24 , pp. 956-960
    • Song, H.S.1    Williams Jr., G.R.2
  • 13
    • 54149106127 scopus 로고    scopus 로고
    • Deformities associated with the suture-bridge technique for full-thickness rotator cuff tears
    • Kim K.C., Rhee K.J., and Shin H.D. Deformities associated with the suture-bridge technique for full-thickness rotator cuff tears. Arthroscopy 24 (2008) 1251-1257
    • (2008) Arthroscopy , vol.24 , pp. 1251-1257
    • Kim, K.C.1    Rhee, K.J.2    Shin, H.D.3
  • 14
    • 34748873787 scopus 로고    scopus 로고
    • Arthroscopic double-row suture anchor fixation of minimally displaced greater tuberosity fractures
    • Ji J.H., Kim W.Y., and Ra K.H. Arthroscopic double-row suture anchor fixation of minimally displaced greater tuberosity fractures. Arthroscopy 23 (2007) 1133.e1-1133.e4. www.arthroscopyjournal.org
    • (2007) Arthroscopy , vol.23
    • Ji, J.H.1    Kim, W.Y.2    Ra, K.H.3
  • 15
    • 21444435692 scopus 로고    scopus 로고
    • Failure mode of suture anchors as a function of insertion depth
    • Bynum C.K., Lee S., Mahar A., Tasto J., and Pedowitz R. Failure mode of suture anchors as a function of insertion depth. Am J Sports Med 33 (2005) 1030-1034
    • (2005) Am J Sports Med , vol.33 , pp. 1030-1034
    • Bynum, C.K.1    Lee, S.2    Mahar, A.3    Tasto, J.4    Pedowitz, R.5
  • 16
    • 0031452936 scopus 로고    scopus 로고
    • Cyclic loading of anchor-based rotator cuff repairs: Confirmation of the tension overload phenomenon and comparison of suture anchor fixation with transosseous fixation
    • Burkhart S.S., Diaz Pagan J.L., Wirth M.A., and Athanasiou K.A. Cyclic loading of anchor-based rotator cuff repairs: Confirmation of the tension overload phenomenon and comparison of suture anchor fixation with transosseous fixation. Arthroscopy 13 (1997) 720-724
    • (1997) Arthroscopy , vol.13 , pp. 720-724
    • Burkhart, S.S.1    Diaz Pagan, J.L.2    Wirth, M.A.3    Athanasiou, K.A.4
  • 17
    • 0030900130 scopus 로고    scopus 로고
    • Cyclic loading of transosseous rotator cuff repairs: Tension overload as a possible cause of failure
    • Burkhart S.S., Johnson T.C., Wirth M.A., and Athanasiou K.A. Cyclic loading of transosseous rotator cuff repairs: Tension overload as a possible cause of failure. Arthroscopy 13 (1997) 172-176
    • (1997) Arthroscopy , vol.13 , pp. 172-176
    • Burkhart, S.S.1    Johnson, T.C.2    Wirth, M.A.3    Athanasiou, K.A.4
  • 18
    • 33750458999 scopus 로고    scopus 로고
    • Triple-loaded single-anchor stitch configurations: An analysis of cyclically loaded suture-tendon interface security
    • Coons D.A., Barber F.A., and Herbert M.A. Triple-loaded single-anchor stitch configurations: An analysis of cyclically loaded suture-tendon interface security. Arthroscopy 22 (2006) 1154-1158
    • (2006) Arthroscopy , vol.22 , pp. 1154-1158
    • Coons, D.A.1    Barber, F.A.2    Herbert, M.A.3
  • 21
    • 58549109431 scopus 로고    scopus 로고
    • Cyclic load and failure behavior of arthroscopic knots and high strength sutures
    • Barber F.A., Herbert M.A., and Beavis R.C. Cyclic load and failure behavior of arthroscopic knots and high strength sutures. Arthroscopy 25 (2009) 192-199
    • (2009) Arthroscopy , vol.25 , pp. 192-199
    • Barber, F.A.1    Herbert, M.A.2    Beavis, R.C.3
  • 22
  • 23
    • 38549160736 scopus 로고    scopus 로고
    • Cyclic load testing and ultimate failure strength of biodegradable glenoid anchors
    • Barber F.A., Coons D.A., and Ruiz-Suarez M. Cyclic load testing and ultimate failure strength of biodegradable glenoid anchors. Arthroscopy 24 (2008) 224-228
    • (2008) Arthroscopy , vol.24 , pp. 224-228
    • Barber, F.A.1    Coons, D.A.2    Ruiz-Suarez, M.3
  • 24
    • 34047143640 scopus 로고    scopus 로고
    • Cyclic load testing of biodegradable suture anchors containing 2 high-strength sutures
    • Barber F.A., Coons D.A., and Ruiz-Suarez M. Cyclic load testing of biodegradable suture anchors containing 2 high-strength sutures. Arthroscopy 23 (2007) 355-360
    • (2007) Arthroscopy , vol.23 , pp. 355-360
    • Barber, F.A.1    Coons, D.A.2    Ruiz-Suarez, M.3
  • 25
    • 55849121489 scopus 로고    scopus 로고
    • High-tension double-row footprint repair compared with reduced-tension single-row repair for massive rotator cuff tears
    • Domb B.G., Glousman R.E., Brooks A., Hansen M., Lee T.Q., and ElAttrache N.S. High-tension double-row footprint repair compared with reduced-tension single-row repair for massive rotator cuff tears. J Bone Joint Surg Am 90 Suppl 4 (2008) 35-39
    • (2008) J Bone Joint Surg Am , vol.90 , Issue.SUPPL. 4 , pp. 35-39
    • Domb, B.G.1    Glousman, R.E.2    Brooks, A.3    Hansen, M.4    Lee, T.Q.5    ElAttrache, N.S.6
  • 27
    • 34047242088 scopus 로고    scopus 로고
    • Arthroscopic rotator cuff repair using a triple-loaded suture anchor and a modified Mason-Allen technique (Alex stitch)
    • Castagna A., Garofalo R., Conti M., Borroni M., and Snyder S.J. Arthroscopic rotator cuff repair using a triple-loaded suture anchor and a modified Mason-Allen technique (Alex stitch). Arthroscopy 23 (2007) 440.e1-440.e4. www.arthroscopyjournal.org
    • (2007) Arthroscopy , vol.23
    • Castagna, A.1    Garofalo, R.2    Conti, M.3    Borroni, M.4    Snyder, S.J.5
  • 28
    • 33847363106 scopus 로고    scopus 로고
    • A biomechanical comparison of the modified Mason-Allen stitch and massive cuff stitch in vitro
    • Sileo M.J., Ruotolo C.R., Nelson C.O., Serra-Hsu F., and Panchal A.P. A biomechanical comparison of the modified Mason-Allen stitch and massive cuff stitch in vitro. Arthroscopy 23 (2007) 235-240.e2. www.arthroscopyjournal.org
    • (2007) Arthroscopy , vol.23
    • Sileo, M.J.1    Ruotolo, C.R.2    Nelson, C.O.3    Serra-Hsu, F.4    Panchal, A.P.5
  • 29
    • 26844477493 scopus 로고    scopus 로고
    • Rotator cuff repair: An ex vivo analysis of suture anchor repair techniques on initial load to failure
    • Cummins C.A., Appleyard R.C., Strickland S., Haen P.S., Chen S., and Murrell G.A. Rotator cuff repair: An ex vivo analysis of suture anchor repair techniques on initial load to failure. Arthroscopy 21 (2005) 1236-1241
    • (2005) Arthroscopy , vol.21 , pp. 1236-1241
    • Cummins, C.A.1    Appleyard, R.C.2    Strickland, S.3    Haen, P.S.4    Chen, S.5    Murrell, G.A.6
  • 31
    • 30144435964 scopus 로고    scopus 로고
    • Evaluation of 5 knots and 2 suture materials for arthroscopic rotator cuff repair: Very strong sutures can still slip
    • Abbi G., Espinoza L., Odell T., Mahar A., and Pedowitz R. Evaluation of 5 knots and 2 suture materials for arthroscopic rotator cuff repair: Very strong sutures can still slip. Arthroscopy 22 (2006) 38-43
    • (2006) Arthroscopy , vol.22 , pp. 38-43
    • Abbi, G.1    Espinoza, L.2    Odell, T.3    Mahar, A.4    Pedowitz, R.5
  • 32
    • 44249105621 scopus 로고    scopus 로고
    • Medial rotator cuff failure after arthroscopic double-row rotator cuff repair
    • Trantalis J.N., Boorman R.S., Pletsch K., and Lo I.K. Medial rotator cuff failure after arthroscopic double-row rotator cuff repair. Arthroscopy 24 (2008) 727-731
    • (2008) Arthroscopy , vol.24 , pp. 727-731
    • Trantalis, J.N.1    Boorman, R.S.2    Pletsch, K.3    Lo, I.K.4
  • 33
    • 34247509751 scopus 로고    scopus 로고
    • A modified suture-bridge technique for a marginal dog-ear deformity caused during rotator cuff repair
    • Kim K.C., Rhee K.J., Shin H.D., and Kim Y.M. A modified suture-bridge technique for a marginal dog-ear deformity caused during rotator cuff repair. Arthroscopy 23 (2007) 562.e1-562.e4. www.arthroscopyjournal.org
    • (2007) Arthroscopy , vol.23
    • Kim, K.C.1    Rhee, K.J.2    Shin, H.D.3    Kim, Y.M.4
  • 34
    • 34249909234 scopus 로고    scopus 로고
    • Clinical evidence shows no difference between single- and double-row repair for rotator cuff tears
    • Reardon D.J., and Maffulli N. Clinical evidence shows no difference between single- and double-row repair for rotator cuff tears. Arthroscopy 23 (2007) 670-673
    • (2007) Arthroscopy , vol.23 , pp. 670-673
    • Reardon, D.J.1    Maffulli, N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.