메뉴 건너뛰기




Volumn 22, Issue 11, 2006, Pages 1154-1158

Triple-Loaded Single-Anchor Stitch Configurations: An Analysis of Cyclically Loaded Suture-Tendon Interface Security

Author keywords

Footprint; Rotator cuff; Suture anchor; Tendon repair; ThreeVo; TwoVo

Indexed keywords

SUTURE MATERIAL;

EID: 33750458999     PISSN: 07498063     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arthro.2006.05.020     Document Type: Article
Times cited : (40)

References (26)
  • 1
    • 11844271559 scopus 로고    scopus 로고
    • Arthroscopic rotator cuff repair in patients older than 60 years
    • Rebuzzi E., Coletti N., Schiavetti S., and Giusto F. Arthroscopic rotator cuff repair in patients older than 60 years. Arthroscopy 21 (2005) 48-54
    • (2005) Arthroscopy , vol.21 , pp. 48-54
    • Rebuzzi, E.1    Coletti, N.2    Schiavetti, S.3    Giusto, F.4
  • 2
    • 5044221036 scopus 로고    scopus 로고
    • Mattress double anchor footprint repair: A novel, arthroscopic rotator cuff repair technique
    • Millett P.J., Mazzocca A., and Guanche C.A. Mattress double anchor footprint repair: A novel, arthroscopic rotator cuff repair technique. Arthroscopy 20 (2004) 875-879
    • (2004) Arthroscopy , vol.20 , pp. 875-879
    • Millett, P.J.1    Mazzocca, A.2    Guanche, C.A.3
  • 3
    • 0035526413 scopus 로고    scopus 로고
    • Arthroscopic rotator cuff repair: Analysis of results by tear size and by repair technique-margin convergence versus direct tendon-to-bone repair
    • Burkhart S.S., Danaceau S.M., and Pearce Jr. C.E. Arthroscopic rotator cuff repair: Analysis of results by tear size and by repair technique-margin convergence versus direct tendon-to-bone repair. Arthroscopy 17 (2001) 905-912
    • (2001) Arthroscopy , vol.17 , pp. 905-912
    • Burkhart, S.S.1    Danaceau, S.M.2    Pearce Jr., C.E.3
  • 4
    • 0031887679 scopus 로고    scopus 로고
    • Arthroscopic rotator cuff repair: Analysis of technique and results at 2- and 3-year follow-up
    • Tauro J.C. Arthroscopic rotator cuff repair: Analysis of technique and results at 2- and 3-year follow-up. Arthroscopy 14 (1998) 45-51
    • (1998) Arthroscopy , vol.14 , pp. 45-51
    • Tauro, J.C.1
  • 5
    • 0031808081 scopus 로고    scopus 로고
    • Arthroscopic repair of full-thickness tears of the rotator cuff
    • Gartsman G.M., Khan M., and Hammerman S.M. Arthroscopic repair of full-thickness tears of the rotator cuff. J Bone Joint Surg Am 80 (1998) 832-840
    • (1998) J Bone Joint Surg Am , vol.80 , pp. 832-840
    • Gartsman, G.M.1    Khan, M.2    Hammerman, S.M.3
  • 6
    • 0347951321 scopus 로고    scopus 로고
    • Arthroscopic rotator cuff repair: 4- to 10-year results
    • Wolf E.M., Pennington W.T., and Agrawal V. Arthroscopic rotator cuff repair: 4- to 10-year results. Arthroscopy 20 (2004) 5-12
    • (2004) Arthroscopy , vol.20 , pp. 5-12
    • Wolf, E.M.1    Pennington, W.T.2    Agrawal, V.3
  • 8
    • 0037492958 scopus 로고    scopus 로고
    • Mode of failure for rotator cuff repair with suture anchors identified at revision surgery
    • Cummins C.A., and Murrell G.A. Mode of failure for rotator cuff repair with suture anchors identified at revision surgery. J Shoulder Elbow Surg 12 (2003) 128-133
    • (2003) J Shoulder Elbow Surg , vol.12 , pp. 128-133
    • Cummins, C.A.1    Murrell, G.A.2
  • 10
    • 84862375694 scopus 로고    scopus 로고
    • An arthroscopic stitch for massive rotator cuff tears: The Mac stitch
    • MacGillivray J.D., and Ma C.B. An arthroscopic stitch for massive rotator cuff tears: The Mac stitch. Arthroscopy 20 (2004) 669-671
    • (2004) Arthroscopy , vol.20 , pp. 669-671
    • MacGillivray, J.D.1    Ma, C.B.2
  • 12
    • 5044221036 scopus 로고    scopus 로고
    • Mattress double anchor footprint repair: A novel, arthroscopic rotator cuff repair technique
    • Millett P.J., Mazzocca A., and Guanche C. Mattress double anchor footprint repair: A novel, arthroscopic rotator cuff repair technique. Arthroscopy 20 (2004) 875-879
    • (2004) Arthroscopy , vol.20 , pp. 875-879
    • Millett, P.J.1    Mazzocca, A.2    Guanche, C.3
  • 13
  • 14
    • 26844477493 scopus 로고    scopus 로고
    • Rotator cuff repair: An ex vivo analysis of suture anchor repair techniques on initial load to failure
    • Cummins C.A., Appleyard R.C., Strickland S., Haen P.S., Chen S., and Murrell G.A. Rotator cuff repair: An ex vivo analysis of suture anchor repair techniques on initial load to failure. Arthroscopy 21 (2005) 1236-1241
    • (2005) Arthroscopy , vol.21 , pp. 1236-1241
    • Cummins, C.A.1    Appleyard, R.C.2    Strickland, S.3    Haen, P.S.4    Chen, S.5    Murrell, G.A.6
  • 17
    • 2142755840 scopus 로고    scopus 로고
    • Abrasion resistance of two types of nonabsorbable braided suture
    • Lo I.K., Burkhart S.S., and Athanasiou K. Abrasion resistance of two types of nonabsorbable braided suture. Arthroscopy 20 (2004) 407-413
    • (2004) Arthroscopy , vol.20 , pp. 407-413
    • Lo, I.K.1    Burkhart, S.S.2    Athanasiou, K.3
  • 18
    • 0030900130 scopus 로고    scopus 로고
    • Cyclic loading of transosseous rotator cuff repairs: Tension overload as a possible cause of failure
    • Burkhart S.S., Johnson T.C., Wirth M.A., and Athanasiou K.A. Cyclic loading of transosseous rotator cuff repairs: Tension overload as a possible cause of failure. Arthroscopy 13 (1997) 172-176
    • (1997) Arthroscopy , vol.13 , pp. 172-176
    • Burkhart, S.S.1    Johnson, T.C.2    Wirth, M.A.3    Athanasiou, K.A.4
  • 19
    • 0031452936 scopus 로고    scopus 로고
    • Cyclic loading of anchor-based rotator cuff repairs: Confirmation of the tension overload phenomenon and comparison of suture anchor fixation with transosseous fixation
    • Burkhart S.S., Diaz Pagan J.L., Wirth M.A., and Athanasiou K.A. Cyclic loading of anchor-based rotator cuff repairs: Confirmation of the tension overload phenomenon and comparison of suture anchor fixation with transosseous fixation. Arthroscopy 13 (1997) 720-724
    • (1997) Arthroscopy , vol.13 , pp. 720-724
    • Burkhart, S.S.1    Diaz Pagan, J.L.2    Wirth, M.A.3    Athanasiou, K.A.4
  • 20
    • 0035526413 scopus 로고    scopus 로고
    • Arthroscopic rotator cuff repair: Analysis of results by tear size and by repair technique-margin convergence versus direct tendon-to-bone repair
    • Burkhart S.S., Danaceau S.M., and Pearce Jr. C.E. Arthroscopic rotator cuff repair: Analysis of results by tear size and by repair technique-margin convergence versus direct tendon-to-bone repair. Arthroscopy 17 (2001) 905-912
    • (2001) Arthroscopy , vol.17 , pp. 905-912
    • Burkhart, S.S.1    Danaceau, S.M.2    Pearce Jr., C.E.3
  • 21
    • 29244471263 scopus 로고    scopus 로고
    • Use of preoperative magnetic resonance imaging to predict rotator cuff tear pattern and method of repair
    • Davidson J.F., Burkhart S.S., Richards D.P., and Campbell S.E. Use of preoperative magnetic resonance imaging to predict rotator cuff tear pattern and method of repair. Arthroscopy 21 (2005) 1428
    • (2005) Arthroscopy , vol.21 , pp. 1428
    • Davidson, J.F.1    Burkhart, S.S.2    Richards, D.P.3    Campbell, S.E.4
  • 22
    • 4444289954 scopus 로고    scopus 로고
    • Margin convergence of the posterior rotator cuff to the biceps tendon
    • Richards D.P., and Burkhart S.S. Margin convergence of the posterior rotator cuff to the biceps tendon. Arthroscopy 20 (2004) 771-775
    • (2004) Arthroscopy , vol.20 , pp. 771-775
    • Richards, D.P.1    Burkhart, S.S.2
  • 23
    • 28744449312 scopus 로고    scopus 로고
    • Increasing the insertion depth of suture anchors for rotator cuff repair does not improve biomechanical stability
    • Mahar A.T., Tucker B.S., Upasani V.V., Oka R.S., and Pedowitz R.A. Increasing the insertion depth of suture anchors for rotator cuff repair does not improve biomechanical stability. J Shoulder Elbow Surg 14 (2005) 626-630
    • (2005) J Shoulder Elbow Surg , vol.14 , pp. 626-630
    • Mahar, A.T.1    Tucker, B.S.2    Upasani, V.V.3    Oka, R.S.4    Pedowitz, R.A.5
  • 24
    • 21444435692 scopus 로고    scopus 로고
    • Failure mode of suture anchors as a function of insertion depth
    • Bynum C.K., Lee S., Mahar A., Tasto J., and Pedowitz R. Failure mode of suture anchors as a function of insertion depth. Am J Sports Med 33 (2005) 1030-1034
    • (2005) Am J Sports Med , vol.33 , pp. 1030-1034
    • Bynum, C.K.1    Lee, S.2    Mahar, A.3    Tasto, J.4    Pedowitz, R.5
  • 25
    • 0028954390 scopus 로고
    • The deadman theory of suture anchors: Observations along a south Texas fence line
    • Burkhart S.S. The deadman theory of suture anchors: Observations along a south Texas fence line. Arthroscopy 11 (1995) 119-123
    • (1995) Arthroscopy , vol.11 , pp. 119-123
    • Burkhart, S.S.1
  • 26
    • 1942532792 scopus 로고    scopus 로고
    • Association of osteopenia of the humeral head with full-thickness rotator cuff tears
    • Meyer D.C., Fucentese S.F., Koller B., and Gerber C. Association of osteopenia of the humeral head with full-thickness rotator cuff tears. J Shoulder Elbow Surg 13 (2004) 333-337
    • (2004) J Shoulder Elbow Surg , vol.13 , pp. 333-337
    • Meyer, D.C.1    Fucentese, S.F.2    Koller, B.3    Gerber, C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.