메뉴 건너뛰기




Volumn 21, Issue 1, 2010, Pages 5-15

Effects of long-term use of a cochlear implant on the electrically evoked compound action potential

Author keywords

Auditory evoked potential; Cochlear implant; Compound action potential; Electrical stimulation; Neural response telemetry

Indexed keywords

ADULT; ARTICLE; CHILD; COCHLEA PROSTHESIS; DEVICE; DISEASE DURATION; ELECTRODE; EVOKED AUDITORY RESPONSE; EVOKED COMPOUND ACTION POTENTIAL; EVOKED RESPONSE; FEMALE; HEARING IMPAIRMENT; HUMAN; IMPLANT; LONG TERM CARE; LONGITUDINAL STUDY; MAJOR CLINICAL STUDY; MALE; NEURAL RESPONSE TELEMETRY; PRIORITY JOURNAL; TELEMETRY; TREATMENT OUTCOME; AGED; COMPARATIVE STUDY; COMPUTER SIMULATION; FOLLOW UP; HEARING LOSS; INFANT; MIDDLE AGED; PATHOPHYSIOLOGY; PHYSIOLOGY; PRESCHOOL CHILD; PROSTHESIS; RETROSPECTIVE STUDY; TIME;

EID: 77449128099     PISSN: 10500545     EISSN: None     Source Type: Journal    
DOI: 10.3766/jaaa.21.1.2     Document Type: Article
Times cited : (43)

References (26)
  • 1
    • 0033042930 scopus 로고    scopus 로고
    • Summary of results using the nucleus CI24M implant to record the electrically evoked compound action potential
    • Abbas PJ, Brown CJ, Shallop JK, et al. (1999) Summary of results using the nucleus CI24M implant to record the electrically evoked compound action potential. Ear Hear 20(1):45-59.
    • (1999) Ear Hear , vol.20 , Issue.1 , pp. 45-59
    • Abbas, P.J.1    Brown, C.J.2    Shallop, J.K.3
  • 2
    • 0007514330 scopus 로고
    • Pediatric plastic and reconstructive surgery of the head and neck In: Bluestone CD
    • Stool SE, Kenna MA, eds, 3rd edition. Philadelphia: WB Saunders
    • Bardach J, Hurwitz DJ. (1983) Pediatric plastic and reconstructive surgery of the head and neck In: Bluestone CD, Stool SE, Kenna MA, eds. Pediatric Otolaryngology. Vol. 1. 3rd edition. Philadelphia: WB Saunders, 805-830.
    • (1983) Pediatric Otolaryngology , vol.1 , pp. 805-830
    • Bardach, J.1    Hurwitz, D.J.2
  • 3
    • 0025000379 scopus 로고
    • Estimation of surviving spiral ganglion cells in the deaf rat using the electrically evoked auditory brainstem response
    • Hall RD. (1990) Estimation of surviving spiral ganglion cells in the deaf rat using the electrically evoked auditory brainstem response. Hear Res 49(1-3):155-168.
    • (1990) Hear Res , vol.49 , Issue.1-3 , pp. 155-168
    • Hall, R.D.1
  • 4
    • 0025890195 scopus 로고
    • Protective effect of electrical stimulation in the deafened guinea pig cochlea
    • Hartshorn DO, Miller JM, Altschuler RA. (1991) Protective effect of electrical stimulation in the deafened guinea pig cochlea. Otolaryngol Head Neck Surg 104(3):311-319.
    • (1991) Otolaryngol Head Neck Surg , vol.104 , Issue.3 , pp. 311-319
    • Hartshorn, D.O.1    Miller, J.M.2    Altschuler, R.A.3
  • 5
    • 33745685477 scopus 로고    scopus 로고
    • A longitudinal study of electrical stimulation levels and electrode impedance in children using the Clarion cochlear implant
    • Henkin Y, Kaplan-Neeman R, Kronenberg J, Migirov L, Hildesheimer M, Muchnik C. (2006) A longitudinal study of electrical stimulation levels and electrode impedance in children using the Clarion cochlear implant. Acta Otolaryngol 126(6):581-586.
    • (2006) Acta Otolaryngol , vol.126 , Issue.6 , pp. 581-586
    • Henkin, Y.1    Kaplan-Neeman, R.2    Kronenberg, J.3    Migirov, L.4    Hildesheimer, M.5    Muchnik, C.6
  • 6
    • 0042669956 scopus 로고    scopus 로고
    • Changes over time in electrical stimulation levels and electrode impedance values in children using the Nucleus 24M cochlear implant
    • Henkin Y, Kaplan-Neeman R, Muchnik C, Kronenberg J, Hildesheimer M. (2003) Changes over time in electrical stimulation levels and electrode impedance values in children using the Nucleus 24M cochlear implant. Int J Pediatr Otorhinolaryngol 67:873-880.
    • (2003) Int J Pediatr Otorhinolaryngol , vol.67 , pp. 873-880
    • Henkin, Y.1    Kaplan-Neeman, R.2    Muchnik, C.3    Kronenberg, J.4    Hildesheimer, M.5
  • 7
    • 0035658396 scopus 로고    scopus 로고
    • A longitudinal study of electrode impedance, the electrically evoked compound action potential, and behavioral measures in nucleus 24 cochlear implant users
    • Hughes ML, Vander Werff KR, Brown CJ, et al. (2001) A longitudinal study of electrode impedance, the electrically evoked compound action potential, and behavioral measures in nucleus 24 cochlear implant users. Ear Hear 22(6):471-486.
    • (2001) Ear Hear , vol.22 , Issue.6 , pp. 471-486
    • Hughes, M.L.1    Vander Werff, K.R.2    Brown, C.J.3
  • 8
    • 47249119603 scopus 로고    scopus 로고
    • Performance groups in adult cochlear implant users: Speech perception results from 1984 until today
    • Krueger B, Joseph G, Rost U, Strauss-Schier A, Lenarz T, Buechner A. (2008) Performance groups in adult cochlear implant users: speech perception results from 1984 until today. Otol Neurotol 29:509-512.
    • (2008) Otol Neurotol , vol.29 , pp. 509-512
    • Krueger, B.1    Joseph, G.2    Rost, U.3    Strauss-Schier, A.4    Lenarz, T.5    Buechner, A.6
  • 9
    • 3142619139 scopus 로고    scopus 로고
    • Longitudinal behaviour of neural response telemetry (NRT) data and clinical implications
    • Lai WK, Aksit M, Akdas F, Dillier N. (2004) Longitudinal behaviour of neural response telemetry (NRT) data and clinical implications. Int J Audiol 43(5):252-263.
    • (2004) Int J Audiol , vol.43 , Issue.5 , pp. 252-263
    • Lai, W.K.1    Aksit, M.2    Akdas, F.3    Dillier, N.4
  • 10
    • 0033523683 scopus 로고    scopus 로고
    • Chronic electrical stimulation by a cochlear implant promotes survival of spiral ganglion neurons after neonatal deafness
    • Leake PA, Hradek GT, Snyder RL. (1999) Chronic electrical stimulation by a cochlear implant promotes survival of spiral ganglion neurons after neonatal deafness. J Comp Neurol 412(4):543-562.
    • (1999) J Comp Neurol , vol.412 , Issue.4 , pp. 543-562
    • Leake, P.A.1    Hradek, G.T.2    Snyder, R.L.3
  • 11
    • 19344366018 scopus 로고    scopus 로고
    • Anatomical consideration and longterm effects of electrical stimulation
    • Zeng F-G, Popper AN, Fay R, eds, New York: Springer
    • Leake PA, Rebscher SJ. (2004) Anatomical consideration and longterm effects of electrical stimulation. In: Zeng F-G, Popper AN, Fay R, eds. Cochlear Implants: Auditory Prostheses and Electric Hearing. New York: Springer.
    • (2004) Cochlear Implants: Auditory Prostheses and Electric Hearing
    • Leake, P.A.1    Rebscher, S.J.2
  • 13
    • 0026481346 scopus 로고
    • Temporal bone histopathology of a patient with a nucleus 22-channel cochlear implant
    • Marsh MA, Coker NJ, Jenkins HA. (1992) Temporal bone histopathology of a patient with a nucleus 22-channel cochlear implant. Am J Otol 13(3):241-248.
    • (1992) Am J Otol , vol.13 , Issue.3 , pp. 241-248
    • Marsh, M.A.1    Coker, N.J.2    Jenkins, H.A.3
  • 14
    • 0033849835 scopus 로고    scopus 로고
    • An improved method of reducing stimulus artifact in the electrically evoked whole-nerve potential
    • Miller CA, Abbas PJ, Brown CJ. (2000) An improved method of reducing stimulus artifact in the electrically evoked whole-nerve potential. Ear Hear 21(4):280-290.
    • (2000) Ear Hear , vol.21 , Issue.4 , pp. 280-290
    • Miller, C.A.1    Abbas, P.J.2    Brown, C.J.3
  • 15
    • 0028015705 scopus 로고
    • The use of long-duration current pulses to assess nerve survival
    • Miller CA, Abbas PJ, Robinson BK. (1994) The use of long-duration current pulses to assess nerve survival. Hear Res 78(1):11-26.
    • (1994) Hear Res , vol.78 , Issue.1 , pp. 11-26
    • Miller, C.A.1    Abbas, P.J.2    Robinson, B.K.3
  • 16
    • 48449103696 scopus 로고    scopus 로고
    • The clinical application of potentials evoked from the peripheral auditory system
    • Miller CA, Brown CJ, Abbas PJ, Chi SL. (2008) The clinical application of potentials evoked from the peripheral auditory system. Hear Res 242(1-2):184-197.
    • (2008) Hear Res , vol.242 , Issue.1-2 , pp. 184-197
    • Miller, C.A.1    Brown, C.J.2    Abbas, P.J.3    Chi, S.L.4
  • 19
    • 0029093292 scopus 로고    scopus 로고
    • Shapiro W, Waltzman S. (1995) Changes in electrical thresholds over time in young children implanted with the Nucleus cochlear prosthesis. In: Clark GM, Cowan RSC, eds. International Cochlear Implant, Speech and Hearing Symposium - Melbourne. Ann Otol Rhinol Laryngol 104(Suppl.):177-178.
    • Shapiro W, Waltzman S. (1995) Changes in electrical thresholds over time in young children implanted with the Nucleus cochlear prosthesis. In: Clark GM, Cowan RSC, eds. International Cochlear Implant, Speech and Hearing Symposium - Melbourne. Ann Otol Rhinol Laryngol 104(Suppl.):177-178.
  • 20
    • 0036898528 scopus 로고    scopus 로고
    • A sensitive period for the development of the central auditory system in children with cochlear implants: Implications for age of implantation
    • Sharma A, Dorman MF, Spahr AJ. (2002) A sensitive period for the development of the central auditory system in children with cochlear implants: implications for age of implantation. Ear Hear 23(6):532-539.
    • (2002) Ear Hear , vol.23 , Issue.6 , pp. 532-539
    • Sharma, A.1    Dorman, M.F.2    Spahr, A.J.3
  • 21
    • 0020701359 scopus 로고
    • Estimating eighth nerve survival by electrical stimulation
    • Smith L, Simmons FB. (1983) Estimating eighth nerve survival by electrical stimulation. Ann Otol Rhinol Laryngol 92(1, pt. 1): 19-23.
    • (1983) Ann Otol Rhinol Laryngol , vol.92 , Issue.1 and PART. 1 , pp. 19-23
    • Smith, L.1    Simmons, F.B.2
  • 22
    • 0035957883 scopus 로고    scopus 로고
    • Relationship between NRT measurements and behavioral levels in children with the Nucleus 24 cochlear implant may change over time: Preliminary report
    • Thai-Van H, Chanal JM, Coudert C, Veuillet E, Truy E, Collet L. (2001) Relationship between NRT measurements and behavioral levels in children with the Nucleus 24 cochlear implant may change over time: preliminary report. Int J Pediatr Otorhinolaryngol 58(2):153-162.
    • (2001) Int J Pediatr Otorhinolaryngol , vol.58 , Issue.2 , pp. 153-162
    • Thai-Van, H.1    Chanal, J.M.2    Coudert, C.3    Veuillet, E.4    Truy, E.5    Collet, L.6
  • 23
    • 0034584461 scopus 로고    scopus 로고
    • 7-year speech perception results and the effects of age, residual hearing and preimplant speech perception in prelingually deaf children using the Nucleus and Clarion cochlear implants
    • Tyler RS, Kelsay DM, Teagle HF, Rubinstein JT, Gantz BJ, Christ AM. (2000) 7-year speech perception results and the effects of age, residual hearing and preimplant speech perception in prelingually deaf children using the Nucleus and Clarion cochlear implants. Adv Otorhinolaryngol 57:305-310.
    • (2000) Adv Otorhinolaryngol , vol.57 , pp. 305-310
    • Tyler, R.S.1    Kelsay, D.M.2    Teagle, H.F.3    Rubinstein, J.T.4    Gantz, B.J.5    Christ, A.M.6
  • 24
    • 38649119509 scopus 로고    scopus 로고
    • Wang N-Y, Eisenberg LS, Johnson KC, et al; CDaCI Investigative Team. (2008) Tracking development of speech recognition: longitudinal data from hierarchical assessments in the Childhood Development after Cochlear Implantation Study Otol Neurotol 29(2):240-245.
    • Wang N-Y, Eisenberg LS, Johnson KC, et al; CDaCI Investigative Team. (2008) Tracking development of speech recognition: longitudinal data from hierarchical assessments in the Childhood Development after Cochlear Implantation Study Otol Neurotol 29(2):240-245.
  • 26
    • 38649125941 scopus 로고    scopus 로고
    • Zwolan TA, O'Sullivan MB, Fink NE, Niparko JK; CDACI Investigative Team. (2008) Electric charge requirements of pediatric cochlear implant recipients enrolled in the Childhood Development After Cochlear Implantation study. Otol Neurotol 29(2): 143-148.
    • Zwolan TA, O'Sullivan MB, Fink NE, Niparko JK; CDACI Investigative Team. (2008) Electric charge requirements of pediatric cochlear implant recipients enrolled in the Childhood Development After Cochlear Implantation study. Otol Neurotol 29(2): 143-148.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.