메뉴 건너뛰기




Volumn 20, Issue 1, 2010, Pages 16-24

Breast tomosynthesis in clinical practice: Initial results

Author keywords

Breast; Cancer; Detection; Mammography; Tomosynthesis

Indexed keywords

ADULT; AGED; ARTICLE; BREAST CANCER; BREAST CARCINOMA; BREAST TOMOSYNTHESIS; CANCER SCREENING; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC ERROR; DIAGNOSTIC VALUE; DIGITAL MAMMOGRAPHY; ECHOMAMMOGRAPHY; FALSE NEGATIVE RESULT; FEMALE; HUMAN; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MASTECTOMY; NUCLEAR MAGNETIC RESONANCE IMAGING; PREDICTION; PRIORITY JOURNAL; PROSPECTIVE STUDY; RADIOGRAPHY; SENSITIVITY AND SPECIFICITY;

EID: 76949108982     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-009-1523-2     Document Type: Article
Times cited : (153)

References (30)
  • 1
    • 0038157026 scopus 로고    scopus 로고
    • Staging system for breast cancer: Revisions for the 6th edition of the AJCC Cancer Staging Manual
    • 10.1016/S0039-6109(03)00034-3 12875597
    • SE Singletary C Allred P Ashley, et al. 2003 Staging system for breast cancer: revisions for the 6th edition of the AJCC Cancer Staging Manual Surg Clin North Am 83 803 819 10.1016/S0039-6109(03)00034-3 12875597
    • (2003) Surg Clin North Am , vol.83 , pp. 803-819
    • Singletary, S.E.1    Allred, C.2    Ashley, P.3
  • 2
    • 0025908633 scopus 로고
    • A review of false negative mammography in a symptomatic population
    • 10.1016/S0009-9260(05)80218-1 1:STN:280:DyaK3MzjvFeqtw%3D%3D 1873944
    • MG Wallis MT Walsh JR Lee 1991 A review of false negative mammography in a symptomatic population Clin Radiol 44 13 15 10.1016/S0009-9260(05)80218-1 1:STN:280:DyaK3MzjvFeqtw%3D%3D 1873944
    • (1991) Clin Radiol , vol.44 , pp. 13-15
    • Wallis, M.G.1    Walsh, M.T.2    Lee, J.R.3
  • 3
    • 0027955298 scopus 로고
    • Reasons underlying negative mammography in patients with palpable breast cancer
    • 10.1016/S0009-9260(05)83454-3 1:STN:280:DyaK2c7ntVGltw%3D%3D 8124890
    • EC Coveney JG Geraghty R O'Laide, et al. 1994 Reasons underlying negative mammography in patients with palpable breast cancer Clin Radiol 49 123 125 10.1016/S0009-9260(05)83454-3 1:STN:280:DyaK2c7ntVGltw%3D%3D 8124890
    • (1994) Clin Radiol , vol.49 , pp. 123-125
    • Coveney, E.C.1    Geraghty, J.G.2    O'Laide, R.3
  • 5
    • 0030098126 scopus 로고    scopus 로고
    • Mammographically negative breast cancer at the Strathfield Breast Centre
    • 10.1111/j.1445-2197.1996.tb01140.x 1:STN:280:DyaK283gslOrsg%3D%3D 8639127
    • SB Chew M Hughes C Kennedy D Gillett H Carmalt 1996 Mammographically negative breast cancer at the Strathfield Breast Centre Aust N Z J Surg 66 134 137 10.1111/j.1445-2197.1996.tb01140.x 1:STN:280:DyaK283gslOrsg%3D%3D 8639127
    • (1996) Aust N Z J Surg , vol.66 , pp. 134-137
    • Chew, S.B.1    Hughes, M.2    Kennedy, C.3    Gillett, D.4    Carmalt, H.5
  • 6
    • 0032834224 scopus 로고    scopus 로고
    • How reliable is modern breast imaging in differentiating benign from malignant breast lesions in the symptomatic population?
    • DOI 10.1016/S0009-9260(99)91090-5
    • HA Moss PD Britton CD Flower, et al. 1999 How reliable is modern breast imaging in differentiating benign from malignant breast lesions in a symptomatic population? Clin Radiol 54 676 682 10.1016/S0009-9260(99)91090-5 1:STN:280:DC%2BD3c%2FgslCjtQ%3D%3D 10541394 (Pubitemid 29479186)
    • (1999) Clinical Radiology , vol.54 , Issue.10 , pp. 676-682
    • Moss, H.A.1    Britton, P.D.2    Flower, C.D.R.3    Freeman, A.H.4    Lomas, D.J.5    Warren, R.M.L.6
  • 7
    • 0036787397 scopus 로고    scopus 로고
    • Comparison of the performance of screening mammography, physical examination, and breast US and evaluation of factors that influence them: An analysis of 27,825 patient evaluations
    • 10.1148/radiol.2251011667 12355001
    • TM Kolb J Lichy JH Newhouse 2002 Comparison of the performance of screening mammography, physical examination, and breast US and evaluation of factors that influence them: an analysis of 27,825 patient evaluations Radiology 225 165 175 10.1148/radiol.2251011667 12355001
    • (2002) Radiology , vol.225 , pp. 165-175
    • Kolb, T.M.1    Lichy, J.2    Newhouse, J.H.3
  • 9
    • 4944262794 scopus 로고    scopus 로고
    • Ultrasound is now better than mammography for the detection of invasive breast cancer
    • DOI 10.1016/j.amjsurg.2004.06.032, PII S0002961004002995
    • SR Benson J Blue K Judd JE Harman 2004 Ultrasound is now better than mammography for the detection of invasive breast cancer Am J Surg 188 381 385 10.1016/j.amjsurg.2004.06.032 1:STN:280:DC%2BD2crgsFaitg%3D%3D 15474430 (Pubitemid 39330540)
    • (2004) American Journal of Surgery , vol.188 , Issue.4 SPEC. ISS. , pp. 381-385
    • Benson, S.R.C.1    Blue, J.2    Judd, K.3    Harman, J.E.4
  • 10
    • 15344342936 scopus 로고    scopus 로고
    • Diagnostic accuracy of mammography, clinical examination, US, and MR imaging in preoperative assessment of breast cancer
    • 10.1148/radiol.2333031484 15486214
    • WA Berg L Gutierrez MS NessAiver WB Carter M Bhargavan RS Lewis OB Ioffe 2004 Diagnostic accuracy of mammography, clinical examination, US, and MR imaging in preoperative assessment of breast cancer Radiology 233 830 849 10.1148/radiol.2333031484 15486214
    • (2004) Radiology , vol.233 , pp. 830-849
    • Berg, W.A.1    Gutierrez, L.2    Nessaiver, M.S.3    Carter, W.B.4    Bhargavan, M.5    Lewis, R.S.6    Ioffe, O.B.7
  • 12
    • 0037434425 scopus 로고    scopus 로고
    • Current applications and future direction of MR mammography
    • DOI 10.1038/sj.bjc.6600713
    • PJ Kneeshaw LW Turnbull PJ Drew 2003 Current applications and future direction of MR mammography Br J Cancer 88 4 10 10.1038/sj.bjc.6600713 1:STN:280:DC%2BD3s%2Fks12rtA%3D%3D 12556951 (Pubitemid 36241210)
    • (2003) British Journal of Cancer , vol.88 , Issue.1 , pp. 4-10
    • Kneeshaw, P.J.1    Turnbull, L.W.2    Drew, P.J.3
  • 13
    • 34548056792 scopus 로고    scopus 로고
    • Current status of breast MR imaging: Part 2. Clinical applications
    • DOI 10.1148/radiol.2443051661
    • CK Kuhl 2007 Current status of breast MR imaging. Part 2. Clinical applications Radiology 244 672 691 10.1148/radiol.2443051661 17709824 (Pubitemid 47292079)
    • (2007) Radiology , vol.244 , Issue.3 , pp. 672-691
    • Kuhl, C.K.1
  • 14
    • 39149144544 scopus 로고    scopus 로고
    • Who should have breast magnetic resonance imaging evaluation?
    • DOI 10.1200/JCO.2007.14.3594
    • S Orel 2008 Who should have breast magnetic resonance imaging evaluation? J Clin Oncol 26 703 11 10.1200/JCO.2007.14.3594 18258977 (Pubitemid 351264382)
    • (2008) Journal of Clinical Oncology , vol.26 , Issue.5 , pp. 703-711
    • Orel, S.1
  • 15
    • 34848839512 scopus 로고    scopus 로고
    • Digital mammography: Clinical implementation and clinical trials
    • DOI 10.1053/j.ro.2007.06.004, PII S0037198X07000387, Breast Imaging
    • CJ D'Orsi MS Newell 2007 Digital mammography: clinical implementation and clinical trials Semin Roentgenol 42 236 242 10.1053/j.ro.2007.06.004 17919526 (Pubitemid 47494505)
    • (2007) Seminars in Roentgenology , vol.42 , Issue.4 , pp. 236-242
    • D'Orsi, C.J.1    Newell, M.S.2
  • 16
    • 34548660847 scopus 로고    scopus 로고
    • Digital mammography: Novel applications
    • DOI 10.1016/j.rcl.2007.06.005, PII S0033838907000930, Breast Imaging
    • EA Rafferty 2007 Digital mammography: novel applications Radiol Clin North Am 45 831 843 10.1016/j.rcl.2007.06.005 17888772 (Pubitemid 47411641)
    • (2007) Radiologic Clinics of North America , vol.45 , Issue.5 , pp. 831-843
    • Rafferty, E.A.1
  • 18
    • 39549123613 scopus 로고    scopus 로고
    • Diagnostic accuracy of digital versus film mammography: Exploratory analysis of selected population subgroups in DMIST
    • 10.1148/radiol.2461070200 18227537
    • ED Pisano RE Hendrick MJ Yaffe, et al. 2008 Diagnostic accuracy of digital versus film mammography: exploratory analysis of selected population subgroups in DMIST Radiology 246 376 383 10.1148/radiol.2461070200 18227537
    • (2008) Radiology , vol.246 , pp. 376-383
    • Pisano, E.D.1    Hendrick, R.E.2    Yaffe, M.J.3
  • 19
    • 36148973645 scopus 로고    scopus 로고
    • Breast tomosynthesis: Present considerations and future applications
    • 10.1148/rg.27si075511 18180229
    • JM Park EA Franken Jr M Garg LL Fajardo LT Niklason 2007 Breast tomosynthesis: present considerations and future applications Radiographics 27 S231 S240 10.1148/rg.27si075511 18180229
    • (2007) Radiographics , vol.27
    • Park, J.M.1    Franken Jr., E.A.2    Garg, M.3    Fajardo, L.L.4    Niklason, L.T.5
  • 20
    • 34848818273 scopus 로고    scopus 로고
    • Advanced applications of digital mammography: Tomosynthesis and contrast-enhanced digital mammography
    • DOI 10.1053/j.ro.2007.06.006, PII S0037198X07000405, Breast Imaging
    • JM Lewin L Niklason 2007 Advanced applications of digital mammography: breast tomosynthesis and contrast-enhanced digital mammography Semin Roentgenol 42 243 252 10.1053/j.ro.2007.06.006 17919527 (Pubitemid 47494507)
    • (2007) Seminars in Roentgenology , vol.42 , Issue.4 , pp. 243-252
    • Lewin, J.M.1    Niklason, L.2
  • 21
    • 34548225376 scopus 로고    scopus 로고
    • Digital breast tomosynthesis: Initial experience in 98 women with abnormal digital screening mammography
    • DOI 10.2214/AJR.07.2231
    • SP Poplack TD Tosteson CA Kogel HM Nagy 2007 Digital breast tomosynthesis: initial experience in 98 women with abnormal digital screening mammography Am J Roentgenol 189 616 623 10.2214/AJR.07.2231 (Pubitemid 47328544)
    • (2007) American Journal of Roentgenology , vol.189 , Issue.3 , pp. 616-623
    • Poplack, S.P.1    Tosteson, T.D.2    Kogel, C.A.3    Nagy, H.M.4
  • 22
    • 0030711575 scopus 로고    scopus 로고
    • Digital breast tomosynthesis in breast imaging
    • 1:STN:280:DyaK1c%2FhvFCgsQ%3D%3D 9356620
    • LT Niklason BT Christian LE Niklason, et al. 1997 Digital breast tomosynthesis in breast imaging Radiology 205 399 406 1:STN:280: DyaK1c%2FhvFCgsQ%3D%3D 9356620
    • (1997) Radiology , vol.205 , pp. 399-406
    • Niklason, L.T.1    Christian, B.T.2    Niklason, L.E.3
  • 24
    • 56349132626 scopus 로고    scopus 로고
    • Breast tomosynthesis and digital mammography: A comparison of breast cancer visibility and BIRADS classification in a population of cancers with subtle mammographic findings
    • 10.1007/s00330-008-1076-9 18641998
    • I Andersson DM Ikeda S Zackrisson M Ruschin T Svahn P Timberg A Tingberg 2008 Breast tomosynthesis and digital mammography: a comparison of breast cancer visibility and BIRADS classification in a population of cancers with subtle mammographic findings Eur Radiol 18 12 2817 2825 10.1007/s00330-008-1076-9 18641998
    • (2008) Eur Radiol , vol.18 , Issue.12 , pp. 2817-2825
    • Andersson, I.1    Ikeda, D.M.2    Zackrisson, S.3    Ruschin, M.4    Svahn, T.5    Timberg, P.6    Tingberg, A.7
  • 26
    • 0032886446 scopus 로고    scopus 로고
    • Glandular breast dose for monoenergetic and high-energy x-ray beams: Monte Carlo assessment 1
    • 1:STN:280:DC%2BD3c%2FgvVWmsw%3D%3D 10540637
    • JM Boone 1999 Glandular breast dose for monoenergetic and high-energy x-ray beams: Monte Carlo assessment 1 Radiology 213 23 37 1:STN:280: DC%2BD3c%2FgvVWmsw%3D%3D 10540637
    • (1999) Radiology , vol.213 , pp. 23-37
    • Boone, J.M.1
  • 27
    • 0036067431 scopus 로고    scopus 로고
    • Breast imaging reporting and data system (BI-RADS)
    • DOI 10.1016/S0033-8389(01)00017-3, PII S0033838901000173
    • L Liberman JH Menell 2002 Breast imaging reporting and data system (BI-RADS) Radiol Clin North Am 40 409 430 10.1016/S0033-8389(01)00017-3 12117184 (Pubitemid 34765031)
    • (2002) Radiologic Clinics of North America , vol.40 , Issue.3 , pp. 409-430
    • Liberman, L.1    Menell, J.H.2
  • 28
    • 34548616391 scopus 로고    scopus 로고
    • BI-RADS decoded: Detailed guidance on potentially confusing issues
    • DOI 10.1016/j.rcl.2007.06.003, PII S0033838907000917, Breast Imaging
    • CJ D'Orsi MS Newell 2007 BI-RADS decoded: detailed guidance on potentially confusing issues Radiol Clin North Am 45 751 763 10.1016/j.rcl.2007.06.003 17888766 (Pubitemid 47410059)
    • (2007) Radiologic Clinics of North America , vol.45 , Issue.5 , pp. 751-763
    • D'Orsi, C.J.1    Newell, M.S.2
  • 29
    • 33846186878 scopus 로고    scopus 로고
    • Initial clinical experience with contrast-enhanced digital breast tomosynthesis
    • DOI 10.1016/j.acra.2006.10.022, PII S1076633206006647
    • SC Chen AK Carton M Albert EF Conant MD Schnall AD Maidment 2007 Initial clinical experience with contrast-enhanced digital breast tomosynthesis Acad Radiol 14 229 238 10.1016/j.acra.2006.10.022 1:CAS:528:DC%2BD1cXlvFGmtL8%3D 17236995 (Pubitemid 46108599)
    • (2007) Academic Radiology , vol.14 , Issue.2 , pp. 229-238
    • Chen, S.C.1    Carton, A.-K.2    Albert, M.3    Conant, E.F.4    Schnall, M.D.5    Maidment, A.D.A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.