-
1
-
-
27544453008
-
Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty
-
DOI 10.2106/JBJS.D.02860
-
DJ Berry M von Knoch CD Schleck WS Harmsen 2005 Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty J Bone Joint Surg Am. 87 2456 2463 10.2106/JBJS.D.02860 16264121 (Pubitemid 41546376)
-
(2005)
Journal of Bone and Joint Surgery - Series A
, vol.87
, Issue.11
, pp. 2456-2463
-
-
Berry, D.J.1
Von Knoch, M.2
Schleck, C.D.3
Harmsen, W.S.4
-
2
-
-
0036918586
-
Femoral head sizes larger than 32 mm against highly cross-linked polyethylene
-
10.1097/00003086-200212000-00018 12461367
-
BR Burroughs HE Rubash WH Harris 2002 Femoral head sizes larger than 32 mm against highly cross-linked polyethylene Clin Orthop Relat Res. 405 150 157 10.1097/00003086-200212000-00018 12461367
-
(2002)
Clin Orthop Relat Res.
, vol.405
, pp. 150-157
-
-
Burroughs, B.R.1
Rubash, H.E.2
Harris, W.H.3
-
4
-
-
38749105452
-
5-Year experience of highly cross-linked polyethylene in cemented and uncemented sockets: Two randomized studies using radiostereometric analysis
-
DOI 10.1080/17453670710014518, PII 790014144
-
G Digas J Karrholm J Thanner P Herberts 2007 5-year experience of highly cross-linked polyethylene in cemented and uncemented sockets: two randomized studies using radiostereometric analysis Acta Orthop. 78 746 754 10.1080/17453670710014518 18236180 (Pubitemid 351185595)
-
(2007)
Acta Orthopaedica
, vol.78
, Issue.6
, pp. 746-754
-
-
Digas, G.1
Karrholm, J.2
Thanner, J.3
Herberts, P.4
-
5
-
-
23044492290
-
Clinical performance of a Durasul highly cross-linked polyethylene acetabular liner for total hip arthroplasty at five years
-
DOI 10.2106/JBJS.D.01915
-
LD Dorr Z Wan C Shahrdar L Sirianni M Boutary A Yun 2005 Clinical performance of a Durasul highly cross-linked polyethylene acetabular liner for total hip arthroplasty at five years J Bone Joint Surg Am. 87 1816 1821 10.2106/JBJS.D.01915 16085624 (Pubitemid 41061203)
-
(2005)
Journal of Bone and Joint Surgery - Series A
, vol.87
, Issue.8
, pp. 1816-1821
-
-
Dorr, L.D.1
Wan, Z.2
Shahrdar, C.3
Sirianni, L.4
Boutary, M.5
Yun, A.6
-
7
-
-
33747887186
-
A randomized prospective evaluation of outcomes after total hip arthroplasty using cross-linked marathon and non-cross-linked enduron polyethylene liners
-
DOI 10.1016/j.arth.2006.05.002, PII S0883540306003871
-
CA Engh Jr AS Stepniewski SD Ginn SE Beykirch CJ Sychterz-Terefenko RH Hopper Jr CA Engh 2006 A randomized prospective evaluation of outcomes after total hip arthroplasty using cross-linked marathon and non-cross-linked Enduron polyethylene liners J Arthroplasty. 21 17 25 10.1016/j.arth.2006.05.002 16950057 (Pubitemid 44293264)
-
(2006)
Journal of Arthroplasty
, vol.21
, Issue.SUPPL.6
, pp. 17-25
-
-
Engh Jr., C.A.1
Stepniewski, A.S.2
Ginn, S.D.3
Beykirch, S.E.4
Sychterz-Terefenko, C.J.5
Hopper Jr., R.H.6
Engh, C.A.7
-
8
-
-
34249942111
-
Comparison of Hip Simulator Wear of 2 Different Highly Cross-linked Ultra High Molecular Weight Polyethylene Acetabular Components Using Both 32- and 38-mm Femoral Heads
-
DOI 10.1016/j.arth.2006.07.009, PII S0883540306005420
-
DM Estok II BR Burroughs OK Muratoglu WH Harris 2007 Comparison of hip simulator wear of 2 different highly cross-linked ultra high molecular weight polyethylene acetabular components using both 32- and 38-mm femoral heads J Arthroplasty. 22 581 589 10.1016/j.arth.2006.07.009 17562417 (Pubitemid 46880180)
-
(2007)
Journal of Arthroplasty
, vol.22
, Issue.4
, pp. 581-589
-
-
Estok II, D.M.1
Burroughs, B.R.2
Muratoglu, O.K.3
Harris, W.H.4
-
9
-
-
28444433471
-
Fatigue crack propagation resistance of virgin and highly crosslinked, thermally treated ultra-high molecular weight polyethylene
-
DOI 10.1016/j.biomaterials.2005.09.010, PII S0142961205008513
-
SJ Gencur CM Rimnac SM Kurtz 2006 Fatigue crack propagation resistance of virgin and highly crosslinked, thermally treated ultra-high molecular weight polyethylene Biomaterials. 27 1550 1557 10.1016/j.biomaterials.2005.09.010 1:CAS:528:DC%2BD2MXht1Kksr7F 16303175 (Pubitemid 41739580)
-
(2006)
Biomaterials
, vol.27
, Issue.8
, pp. 1550-1557
-
-
Gencur, S.J.1
Rimnac, C.M.2
Kurtz, S.M.3
-
10
-
-
40749130415
-
Does highly cross-linked polyethylene wear less than conventional polyethylene in total hip arthroplasty? A double-blind, randomized, and controlled trial using roentgen stereophotogrammetric analysis
-
10.1016/j.arth.2006.12.117 18358369
-
S Glyn-Jones S Isaac J Hauptfleisch P McLardy-Smith DW Murray HS Gill 2008 Does highly cross-linked polyethylene wear less than conventional polyethylene in total hip arthroplasty? A double-blind, randomized, and controlled trial using roentgen stereophotogrammetric analysis J Arthroplasty. 23 337 343 10.1016/j.arth.2006.12.117 18358369
-
(2008)
J Arthroplasty.
, vol.23
, pp. 337-343
-
-
Glyn-Jones, S.1
Isaac, S.2
Hauptfleisch, J.3
McLardy-Smith, P.4
Murray, D.W.5
Gill, H.S.6
-
11
-
-
1842473877
-
Recurrent dislocation after revision total hip replacement with a large prosthetic femoral head. A case report
-
15069152
-
D Halley A Glassman RD Crowninshield 2004 Recurrent dislocation after revision total hip replacement with a large prosthetic femoral head. A case report J Bone Joint Surg Am. 86 827 830 15069152
-
(2004)
J Bone Joint Surg Am.
, vol.86
, pp. 827-830
-
-
Halley, D.1
Glassman, A.2
Crowninshield, R.D.3
-
12
-
-
26444582223
-
Impingement of acetabular cups in a hip simulator: Comparison of highly cross-linked and conventional polyethylene
-
DOI 10.1016/j.arth.2005.04.026, PII S0883540305002640
-
KG Holley BD Furman OM Babalola JD Lipman DE Padgett TM Wright 2005 Impingement of acetabular cups in a hip simulator: comparison of highly cross-linked and conventional polyethylene J Arthroplasty. 20 77 86 10.1016/j.arth.2005.04.026 16214007 (Pubitemid 41425790)
-
(2005)
Journal of Arthroplasty
, vol.20
, Issue.SUPPL. 3
, pp. 77-86
-
-
Holley, K.G.1
Furman, B.D.2
Babalola, O.M.3
Lipman, J.D.4
Padgett, D.E.5
Wright, T.M.6
-
13
-
-
33846473680
-
Impingement contributes to backside wear and screw-metallic shell fretting in modular acetabular cups
-
DOI 10.1016/j.arth.2005.01.025, PII S0883540306006292
-
M Kligman BD Furman DE Padgett TM Wright 2007 Impingement contributes to backside wear and screw-metallic shell fretting in modular acetabular cups J Arthroplasty. 22 258 264 10.1016/j.arth.2005.01.025 17275644 (Pubitemid 46162094)
-
(2007)
Journal of Arthroplasty
, vol.22
, Issue.2
, pp. 258-264
-
-
Kligman, M.1
Furman, B.D.2
Padgett, D.E.3
Wright, T.M.4
-
14
-
-
33846110261
-
Influence of femoral head size on impingement, dislocation and stress distribution in total hip replacement
-
DOI 10.1016/j.medengphy.2006.07.001, PII S1350453306001433
-
D Kluess H Martin W Mittelmeier KP Schmitz R Bader 2007 Influence of femoral head size on impingement, dislocation and stress distribution in total hip replacement Med Eng Phys. 29 465 471 10.1016/j.medengphy.2006.07.001 16901743 (Pubitemid 46074439)
-
(2007)
Medical Engineering and Physics
, vol.29
, Issue.4
, pp. 465-471
-
-
Kluess, D.1
Martin, H.2
Mittelmeier, W.3
Schmitz, K.-P.4
Bader, R.5
-
15
-
-
26844478198
-
Mechanical properties of retrieved highly cross-linked crossfire liners after short-term implantation
-
DOI 10.1016/j.arth.2005.07.015, PII S0883540305004122
-
SM Kurtz W Hozack J Turner J Purtill D MacDonald P Sharkey J Parvizi M Manley R Rothman 2005 Mechanical properties of retrieved highly cross-linked crossfire liners after short-term implantation J Arthroplasty. 20 840 849 10.1016/j.arth.2005.07.015 16230233 (Pubitemid 41463682)
-
(2005)
Journal of Arthroplasty
, vol.20
, Issue.7
, pp. 840-849
-
-
Kurtz, S.M.1
Hozack, W.2
Turner, J.3
Purtill, J.4
MacDonald, D.5
Sharkey, P.6
Parvizi, J.7
Manley, M.8
Rothman, R.9
-
16
-
-
0030198688
-
Adaptive finite element modeling of long-term polyethylene wear in total hip arthroplasty
-
10.1002/jor.1100140424 1:STN:280:DyaK28zltValtA%3D%3D 8764879
-
TA Maxian TD Brown DR Pedersen JJ Callaghan 1996 Adaptive finite element modeling of long-term polyethylene wear in total hip arthroplasty J Orthop Res. 14 668 675 10.1002/jor.1100140424 1:STN:280:DyaK28zltValtA%3D%3D 8764879
-
(1996)
J Orthop Res.
, vol.14
, pp. 668-675
-
-
Maxian, T.A.1
Brown, T.D.2
Pedersen, D.R.3
Callaghan, J.J.4
-
17
-
-
0035217940
-
Larger diameter femoral heads used in conjunction with a highly cross-linked ultra-high molecular weight polyethylene: A new concept
-
DOI 10.1054/arth.2001.28376
-
OK Muratoglu CR Bragdon D O'Connor RS Perinchief DM Estok II M Jasty WH Harris 2001 Larger diameter femoral heads used in conjunction with a highly cross-linked ultra-high molecular weight polyethylene: a new concept J Arthroplasty. 16 24 30 10.1054/arth.2001.28376 1:STN:280:DC%2BD3MjgtFSrtA%3D%3D 11742447 (Pubitemid 33151043)
-
(2001)
Journal of Arthroplasty
, vol.16
, Issue.8 SUPPL. 1
, pp. 24-30
-
-
Muratoglu, O.K.1
Bragdon, C.R.2
O'Connor, D.3
Perinchief, R.S.4
Estok II, D.M.5
Jasty, M.6
Harris, W.H.7
-
18
-
-
0035117295
-
A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties: Recipient of the 1999 HAP Paul award
-
DOI 10.1054/arth.2001.20540
-
OK Muratoglu CR Bragdon DO O'Connor M Jasty WH Harris 2001 A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul award J Arthroplasty 16 149 160 10.1054/arth.2001.20540 1:STN:280:DC%2BD3M3lslyjtQ%3D%3D 11222887 (Pubitemid 32163841)
-
(2001)
Journal of Arthroplasty
, vol.16
, Issue.2
, pp. 149-160
-
-
Muratoglu, O.K.1
Bragdon, C.R.2
O'Connor, D.O.3
Jasty, M.4
Harris, W.H.5
-
21
-
-
33845948266
-
Contact stress assessment of conventional and highly crosslinked ultra high molecular weight polyethylene acetabular liners with finite element analysis and pressure sensitive film
-
16680685
-
GR Plank DM Estok II OK Muratoglu DO O'Connor BR Burroughs WH Harris 2007 Contact stress assessment of conventional and highly crosslinked ultra high molecular weight polyethylene acetabular liners with finite element analysis and pressure sensitive film J Biomed Mater Res B Appl Biomater. 80 1 10 16680685
-
(2007)
J Biomed Mater Res B Appl Biomater.
, vol.80
, pp. 1-10
-
-
Plank, G.R.1
Estok Ii, D.M.2
Muratoglu, O.K.3
O'Connor, D.O.4
Burroughs, B.R.5
Harris, W.H.6
-
22
-
-
4444233039
-
Deformation, yielding, fracture and fatigue behavior of conventional and highly cross-linked ultra high molecular weight polyethylene
-
DOI 10.1016/j.biomaterials.2004.03.022, PII S0142961204002820
-
LA Pruitt 2005 Deformation, yielding, fracture and fatigue behavior of conventional and highly cross-linked ultra high molecular weight polyethylene Biomaterials. 26 905 915 10.1016/j.biomaterials.2004.03.022 1:CAS:528: DC%2BD2cXnt1Kjs7w%3D 15353202 (Pubitemid 39194962)
-
(2005)
Biomaterials
, vol.26
, Issue.8
, pp. 905-915
-
-
Pruitt, L.A.1
-
23
-
-
58249094140
-
Five-year comparative study of highly cross-linked (crossfire) and traditional polyethylene
-
10.1016/j.arth.2007.09.015 18534491
-
AD Rajadhyaksha C Brotea Y Cheung C Kuhn R Ramakrishnan SB Zelicof 2009 Five-year comparative study of highly cross-linked (crossfire) and traditional polyethylene J Arthroplasty. 24 161 167 10.1016/j.arth.2007.09.015 18534491
-
(2009)
J Arthroplasty.
, vol.24
, pp. 161-167
-
-
Rajadhyaksha, A.D.1
Brotea, C.2
Cheung, Y.3
Kuhn, C.4
Ramakrishnan, R.5
Zelicof, S.B.6
-
24
-
-
20444399895
-
Impingement in total hip arthroplasty: A study of retrieved acetabular components
-
DOI 10.1016/j.arth.2004.09.058, PII S0883540304006631
-
WY Shon T Baldini MG Peterson TM Wright EA Salvati 2005 Impingement in total hip arthroplasty a study of retrieved acetabular components J Arthroplasty. 20 427 435 10.1016/j.arth.2004.09.058 16124957 (Pubitemid 40804447)
-
(2005)
Journal of Arthroplasty
, vol.20
, Issue.4
, pp. 427-435
-
-
Won, Y.S.1
Baldini, T.2
Peterson, M.G.3
Wright, T.M.4
Salvati, E.A.5
|