메뉴 건너뛰기




Volumn 80, Issue 1, 2007, Pages 1-10

Contact stress assessment of conventional and highly crosslinked ultra high molecular weight polyethylene acetabular liners with finite element analysis and pressure sensitive film

Author keywords

Acetabular; Crosslinked; FEA; Fuji Film; Polyethylene; THR

Indexed keywords

CROSSLINKING; FINITE ELEMENT METHOD; STRESS ANALYSIS; THIN FILMS;

EID: 33845948266     PISSN: 00219304     EISSN: 15524981     Source Type: Journal    
DOI: 10.1002/jbm.b.30560     Document Type: Article
Times cited : (28)

References (26)
  • 1
    • 0032922181 scopus 로고    scopus 로고
    • Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene
    • Wroblewski BM, Siney PD, Fleming PA. Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene. J Bone Joint Surg Br 1999;81:54-55.
    • (1999) J Bone Joint Surg Br , vol.81 , pp. 54-55
    • Wroblewski, B.M.1    Siney, P.D.2    Fleming, P.A.3
  • 2
    • 0035217958 scopus 로고    scopus 로고
    • Study of retrieved acetabular sockets made from high-dose, cross-linked polyethylene
    • Oonishi H, Clarke IC, Masuda S, Amino H. Study of retrieved acetabular sockets made from high-dose, cross-linked polyethylene. J Arthroplasty 2001;16(8, Suppl 1):129-133.
    • (2001) J Arthroplasty , vol.16 , Issue.8 and SUPPL. 1 , pp. 129-133
    • Oonishi, H.1    Clarke, I.C.2    Masuda, S.3    Amino, H.4
  • 3
    • 0035078816 scopus 로고    scopus 로고
    • γ-irradiated cross-linked polyethylene in total hip replacements-analysis of retrieved sockets after long-term implantation
    • Oonishi H, Kadoya Y, Masuda S. γ-irradiated cross-linked polyethylene in total hip replacements-analysis of retrieved sockets after long-term implantation. J Biomed Mater Res 2001;58:167-171.
    • (2001) J Biomed Mater Res , vol.58 , pp. 167-171
    • Oonishi, H.1    Kadoya, Y.2    Masuda, S.3
  • 4
    • 33845919290 scopus 로고    scopus 로고
    • Grobbelaar CJ, Weber FA, Spirakis A, DuPlessis TA, Cappaert G, Cakic JN. Clinical experience with γ irradiation-crosslinked polyethylene-A 14 to 20 year follow-up report. S Afr Bone Joint Surg 1999;XI(3):140-147.
    • Grobbelaar CJ, Weber FA, Spirakis A, DuPlessis TA, Cappaert G, Cakic JN. Clinical experience with γ irradiation-crosslinked polyethylene-A 14 to 20 year follow-up report. S Afr Bone Joint Surg 1999;XI(3):140-147.
  • 5
    • 0035117295 scopus 로고    scopus 로고
    • A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation and retain mechanical properties. Recipient of the 1999 HAP Paul Award
    • Muratoglu OK, Bragdon CR, O'Connor DO, Jasty M, Harris WH. A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation and retain mechanical properties. Recipient of the 1999 HAP Paul Award. J Arthroplasty 2001;16:149-160.
    • (2001) J Arthroplasty , vol.16 , pp. 149-160
    • Muratoglu, O.K.1    Bragdon, C.R.2    O'Connor, D.O.3    Jasty, M.4    Harris, W.H.5
  • 6
    • 0002875601 scopus 로고    scopus 로고
    • A comparison of five different types of highly cross-linked UHMWPEs: Physical properties and wear behavior
    • Muratoglu OK, Bragdon CR, O'Connor DO, Jasty M, Harris WH. A comparison of five different types of highly cross-linked UHMWPEs: Physical properties and wear behavior. Trans Orthop Res Soc 1999;24:77.
    • (1999) Trans Orthop Res Soc , vol.24 , pp. 77
    • Muratoglu, O.K.1    Bragdon, C.R.2    O'Connor, D.O.3    Jasty, M.4    Harris, W.H.5
  • 8
    • 0035217940 scopus 로고    scopus 로고
    • Larger diameter femoral heads used in conjunction with a highly cross-linked ultra-high molecular weight polyethylene
    • Muratoglu OK, Bragdon CR, O'Connor D, Perinchief RS, Estok DM II, Jasty M, Harris WH. Larger diameter femoral heads used in conjunction with a highly cross-linked ultra-high molecular weight polyethylene. J Arthroplasty 2001;16(8, Suppl 1):24-30.
    • (2001) J Arthroplasty , vol.16 , Issue.8 and SUPPL. 1 , pp. 24-30
    • Muratoglu, O.K.1    Bragdon, C.R.2    O'Connor, D.3    Perinchief, R.S.4    Estok II, D.M.5    Jasty, M.6    Harris, W.H.7
  • 9
    • 0033065656 scopus 로고    scopus 로고
    • Effect of molecular weight, calcium stearate, and sterilization methods on the wear of ultra high molecular weight polyethylene acetabular cups in a hip joint simulator
    • McKellop HA, Shen F, Campbell P, Ota T. Effect of molecular weight, calcium stearate, and sterilization methods on the wear of ultra high molecular weight polyethylene acetabular cups in a hip joint simulator. J Orthop Res 1999;17:329-339.
    • (1999) J Orthop Res , vol.17 , pp. 329-339
    • McKellop, H.A.1    Shen, F.2    Campbell, P.3    Ota, T.4
  • 12
    • 33845925782 scopus 로고    scopus 로고
    • The wear of one form of electron beam, highly crosslinked, melted UHMWPE is independent of head size in hip simulator testing
    • O'Connor DO, Bragdon CR, Muratoglu OK, Jasty M, Travers JT, Harris WH. The wear of one form of electron beam, highly crosslinked, melted UHMWPE is independent of head size in hip simulator testing. Trans Soc Biomater 2001;579.
    • (2001) Trans Soc Biomater , pp. 579
    • O'Connor, D.O.1    Bragdon, C.R.2    Muratoglu, O.K.3    Jasty, M.4    Travers, J.T.5    Harris, W.H.6
  • 13
    • 0035216918 scopus 로고    scopus 로고
    • A novel constrained acetabular liner design with increased range of motion
    • Burroughs BR, Golladay GJ, Hallstrom B, Harris WH. A novel constrained acetabular liner design with increased range of motion. J Arthroplasty 2001;16(8, Suppl 1):31-36.
    • (2001) J Arthroplasty , vol.16 , Issue.8 and SUPPL. 1 , pp. 31-36
    • Burroughs, B.R.1    Golladay, G.J.2    Hallstrom, B.3    Harris, W.H.4
  • 14
    • 0036918586 scopus 로고    scopus 로고
    • Femoral head sizes larger than 32 mm against highly cross-linked polyethylene
    • Burroughs BR, Rubash HE, Harris WH. Femoral head sizes larger than 32 mm against highly cross-linked polyethylene. Clin Orthop Relat Res 2002;405:150-157.
    • (2002) Clin Orthop Relat Res , vol.405 , pp. 150-157
    • Burroughs, B.R.1    Rubash, H.E.2    Harris, W.H.3
  • 15
    • 0022107624 scopus 로고
    • The effect of conformity and plastic thickness on contact stresses in metal-backed plastic implants
    • Bartel DL, Burstein AH, Toda MD, Edwards DL. The effect of conformity and plastic thickness on contact stresses in metal-backed plastic implants. J Biomech Eng 1985;107:193-199.
    • (1985) J Biomech Eng , vol.107 , pp. 193-199
    • Bartel, D.L.1    Burstein, A.H.2    Toda, M.D.3    Edwards, D.L.4
  • 16
    • 1842473877 scopus 로고    scopus 로고
    • Recurrent dislocation after revision total hip replacement with a large prosthetic femoral head
    • Halley D, Glassman A, Crowninshield RD. Recurrent dislocation after revision total hip replacement with a large prosthetic femoral head. J Bone Joint Surg Am 2004;86:827-830.
    • (2004) J Bone Joint Surg Am , vol.86 , pp. 827-830
    • Halley, D.1    Glassman, A.2    Crowninshield, R.D.3
  • 19
    • 0042957553 scopus 로고
    • Lubrication and wear of the Charnley, Charnley-Muller, and McKee-Farrar prostheses with special regard to their clinical behaviour
    • Saint Louis, MO;
    • Simon SR, Radin EL. Lubrication and wear of the Charnley, Charnley-Muller, and McKee-Farrar prostheses with special regard to their clinical behaviour. In: Proceedings of the Hip Society, Saint Louis, MO; 1973.
    • (1973) Proceedings of the Hip Society
    • Simon, S.R.1    Radin, E.L.2
  • 20
    • 0014746120 scopus 로고
    • Abduction forces in the one-legged stance
    • McLeish RD, Charnley J. Abduction forces in the one-legged stance. J Biomech 1970;3:191-209.
    • (1970) J Biomech , vol.3 , pp. 191-209
    • McLeish, R.D.1    Charnley, J.2
  • 21
    • 0032801070 scopus 로고    scopus 로고
    • Simulation of initial frontside and backside wear rates in a modular acetabular component with multiple screw holes
    • Kurtz SM, Ochoa JA, Hovey CB, White CV. Simulation of initial frontside and backside wear rates in a modular acetabular component with multiple screw holes. J Biomech 1999;32:967-976.
    • (1999) J Biomech , vol.32 , pp. 967-976
    • Kurtz, S.M.1    Ochoa, J.A.2    Hovey, C.B.3    White, C.V.4
  • 22
    • 0023007566 scopus 로고
    • The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement
    • Bartel DL, Bicknell VL, Wright TM. The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement. J Bone Joint Surg Am 1986;68:1041-1051.
    • (1986) J Bone Joint Surg Am , vol.68 , pp. 1041-1051
    • Bartel, D.L.1    Bicknell, V.L.2    Wright, T.M.3
  • 23
    • 14844312072 scopus 로고    scopus 로고
    • The measurement of creep in ultra-high molecular weight polyethylene. A comparison of conventional versus highly cross-linked polyethylene
    • Estok DM II, Bragdon CR, Plank GR, Huang A, Muratoglu OK, Harris WH. The measurement of creep in ultra-high molecular weight polyethylene. A comparison of conventional versus highly cross-linked polyethylene. J Arthroplasty 2005;20:239-243.
    • (2005) J Arthroplasty , vol.20 , pp. 239-243
    • Estok II, D.M.1    Bragdon, C.R.2    Plank, G.R.3    Huang, A.4    Muratoglu, O.K.5    Harris, W.H.6
  • 24
    • 0029887658 scopus 로고    scopus 로고
    • Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups
    • Wroblewski BM, Siney PD, Dowson D, Collins SN. Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups. J Bone Joint Surg Br 1996;78:280-285.
    • (1996) J Bone Joint Surg Br , vol.78 , pp. 280-285
    • Wroblewski, B.M.1    Siney, P.D.2    Dowson, D.3    Collins, S.N.4
  • 25
    • 0038016670 scopus 로고    scopus 로고
    • Failure micromechanisms during uniaxial tensile fracture of conventional and highly crosslinked ultra-high molecular weight polyethylene used in total joint replacements
    • Gencur SJ, Rimnac CM, Kurtz SM. Failure micromechanisms during uniaxial tensile fracture of conventional and highly crosslinked ultra-high molecular weight polyethylene used in total joint replacements. Biomaterials 2003;24:3947-3954.
    • (2003) Biomaterials , vol.24 , pp. 3947-3954
    • Gencur, S.J.1    Rimnac, C.M.2    Kurtz, S.M.3
  • 26
    • 0141447819 scopus 로고    scopus 로고
    • The effect of degree of crosslinking on the fatigue crack initiation and propagation resistance of orthopedic grade polyethylene
    • Baker DA, Bellare A, Pruitt L. The effect of degree of crosslinking on the fatigue crack initiation and propagation resistance of orthopedic grade polyethylene. J Biomed Mater Res A 2003;66:146-154.
    • (2003) J Biomed Mater Res A , vol.66 , pp. 146-154
    • Baker, D.A.1    Bellare, A.2    Pruitt, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.