메뉴 건너뛰기




Volumn 37, Issue 2, 2010, Pages 649-661

Dosimetric accuracy of a deterministic radiation transport based 192Ir brachytherapy treatment planning system. Part I: Single sources and bounded homogeneous geometries

Author keywords

Brachytherapy; Dosimetry; HDR; Treatment planning

Indexed keywords

GEOMETRY; MONTE CARLO METHODS; ONCOLOGY; PHANTOMS; RADIATIVE TRANSFER; RADIOTHERAPY; RESPIRATORY MECHANICS;

EID: 75749151354     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3290630     Document Type: Article
Times cited : (60)

References (40)
  • 1
    • 0028919251 scopus 로고
    • Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43. American Association of Physicists in Medicine
    • MPHYA6 0094-2405,. 10.1118/1.597458
    • R. Nath, L. L. Anderson, G. Luxton, K. A. Weaver, J. F. Williamson, and A. S. Meigooni, " Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43. American Association of Physicists in Medicine.," Med. Phys. MPHYA6 0094-2405 22, 209-234 (1995). 10.1118/1.597458
    • (1995) Med. Phys. , vol.22 , pp. 209-234
    • Nath, R.1    Anderson, L.L.2    Luxton, G.3    Weaver, K.A.4    Williamson, J.F.5    Meigooni, A.S.6
  • 2
    • 1142304255 scopus 로고    scopus 로고
    • Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations
    • DOI 10.1118/1.1646040
    • M. J. Rivard, B. M. Coursey, L. A. DeWerd, W. F. Hanson, M. S. Huq, G. S. Ibbott, M. G. Mitch, R. Nath, and J. F. Williamson, " Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations.," Med. Phys. MPHYA6 0094-2405 31, 633-674 (2004). 10.1118/1.1646040 (Pubitemid 38381028)
    • (2004) Medical Physics , vol.31 , Issue.3 , pp. 633-674
    • Rivard, M.J.1    Coursey, B.M.2    DeWerd, L.A.3    Hanson, W.F.4    Huq, M.S.5    Ibbott, G.S.6    Mitch, M.G.7    Nath, R.8    Williamson, J.F.9
  • 4
    • 52949154288 scopus 로고    scopus 로고
    • Anniversary paper: Past and current issues, and trends in brachytherapy physics
    • MPHYA6 0094-2405,. 10.1118/1.2981826
    • B. R. Thomadsen, J. F. Williamson, M. J. Rivard, and A. S. Meigooni, " Anniversary paper: Past and current issues, and trends in brachytherapy physics.," Med. Phys. MPHYA6 0094-2405 35, 4708-4723 (2008). 10.1118/1.2981826
    • (2008) Med. Phys. , vol.35 , pp. 4708-4723
    • Thomadsen, B.R.1    Williamson, J.F.2    Rivard, M.J.3    Meigooni, A.S.4
  • 5
    • 66449131989 scopus 로고    scopus 로고
    • The evolution of brachytherapy treatment planning
    • MPHYA6 0094-2405,. 10.1118/1.3125136
    • M. J. Rivard, J. L. M. Venselaar, and L. Beaulieu, " The evolution of brachytherapy treatment planning.," Med. Phys. MPHYA6 0094-2405 36, 2136-2153 (2009). 10.1118/1.3125136
    • (2009) Med. Phys. , vol.36 , pp. 2136-2153
    • Rivard, M.J.1    Venselaar, J.L.M.2    Beaulieu, L.3
  • 6
    • 3242749913 scopus 로고    scopus 로고
    • 192Ir HDR brachytherapy: A Monte Carlo and analytical dosimetry study
    • DOI 10.1088/0031-9155/49/12/014, PII S0031915504775570
    • G. Anagnostopoulos, D. Baltas, E. Pantelis, P. Papagiannis, and L. Sakelliou, " The effect of patient inhomogeneities in oesophageal 192Ir HDR brachytherapy: A Monte Carlo and analytical dosimetry study.," Phys. Med. Biol. PHMBA7 0031-9155 49, 2675-2685 (2004). 10.1088/0031-9155/49/12/014 (Pubitemid 38967952)
    • (2004) Physics in Medicine and Biology , vol.49 , Issue.12 , pp. 2675-2685
    • Anagnostopoulos, G.1    Baltas, D.2    Pantelis, E.3    Papagiannis, P.4    Sakelliou, L.5
  • 7
    • 34447290009 scopus 로고    scopus 로고
    • Postimplant dosimetry using a Monte Carlo dose calculation engine: A new clinical standard
    • IOBPD3 0360-3016,. 10.1016/j.ijrob2007.02.036
    • J. F. Carrier, M. D'Amours, F. Verhaegen, B. Reniers, A. G. Martin, E. Vigneault, and L. Beaulieu, " Postimplant dosimetry using a Monte Carlo dose calculation engine: A new clinical standard.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 68, 1190-1198 (2007). 10.1016/j.ijrobp.2007.02. 036
    • (2007) Int. J. Radiat. Oncol., Biol., Phys. , vol.68 , pp. 1190-1198
    • Carrier, J.F.1    D'Amours, M.2    Verhaegen, F.3    Reniers, B.4    Martin, A.G.5    Vigneault, E.6    Beaulieu, L.7
  • 8
    • 33644624376 scopus 로고    scopus 로고
    • Impact of interseed attenuation and tissue composition for permanent prostate implants
    • DOI 10.1118/1.2168295
    • J. -F. Carrier, L. Beaulieu, F. Therriault-Proulx, and R. Roy, " Impact of interseed attenuation and tissue composition for permanent prostate implants.," Med. Phys. MPHYA6 0094-2405 33, 595-604 (2006). 10.1118/1.2168295 (Pubitemid 43320163)
    • (2006) Medical Physics , vol.33 , Issue.3 , pp. 595-604
    • Carrier, J.-F.1    Beaulieu, L.2    Therriault-Proulx, F.3    Roy, R.4
  • 9
    • 16344379083 scopus 로고    scopus 로고
    • The effect of finite patient dimensions and tissue inhomogeneities on dosimetry planning of 192Ir HDR breast brachytherapy: A Monte Carlo dose verification study
    • IOBPD3 0360-3016,. 10.1016/j.ijrob2004.12.065
    • E. Pantelis, P. Papagiannis, P. Karaiskos, A. Angelopoulos, G. Anagnostopoulos, D. Baltas, N. Zamboglou, and L. Sakelliou, " The effect of finite patient dimensions and tissue inhomogeneities on dosimetry planning of 192Ir HDR breast brachytherapy: A Monte Carlo dose verification study.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 61, 1596-1602 (2005). 10.1016/j.ijrobp.2004.12.065
    • (2005) Int. J. Radiat. Oncol., Biol., Phys. , vol.61 , pp. 1596-1602
    • Pantelis, E.1    Papagiannis, P.2    Karaiskos, P.3    Angelopoulos, A.4    Anagnostopoulos, G.5    Baltas, D.6    Zamboglou, N.7    Sakelliou, L.8
  • 10
    • 9244252516 scopus 로고    scopus 로고
    • 192Ir brachytherapy applications with a shielded cylindrical applicator set
    • DOI 10.1118/1.1810233
    • G. Lymperopoulou, E. Pantelis, P. Papagiannis, H. Rozaki-Mavrouli, L. Sakelliou, D. Baltas, and P. Karaiskos, " A Monte Carlo dosimetry study of vaginal 192Ir brachytherapy applications with a shielded cylindrical applicator set.," Med. Phys. MPHYA6 0094-2405 31, 3080-3086 (2004). 10.1118/1.1810233 (Pubitemid 39552698)
    • (2004) Medical Physics , vol.31 , Issue.11 , pp. 3080-3086
    • Lymperopoulou, G.1    Pantelis, E.2    Papagiannis, P.3    Rozaki-Mavrouli, H.4    Sakelliou, L.5    Baltas, D.6    Karaiskos, P.7
  • 11
    • 0035110362 scopus 로고    scopus 로고
    • On the validity of the superposition principle in dose calculations for intracavitary implants with shielded vaginal colpostats
    • DOI 10.1118/1.1339224
    • J. Markman, J. F. Williamson, J. F. Dempsey, and D. A. Low, " On the validity of the superposition principle in dose calculations for intracavitary implants with shielded vaginal colpostats.," Med. Phys. MPHYA6 0094-2405 28, 147-155 (2001). 10.1118/1.1339224 (Pubitemid 32165750)
    • (2001) Medical Physics , vol.28 , Issue.2 , pp. 147-155
    • Markman, J.1    Williamson, J.F.2    Dempsey, J.F.3    Low, D.A.4
  • 12
    • 23944509702 scopus 로고    scopus 로고
    • 125I prostate implants
    • DOI 10.1118/1.1897466
    • 125I prostate implants.," Med. Phys. MPHYA6 0094-2405 32, 2557-2566 (2005). 10.1118/1.1897466 (Pubitemid 41197193)
    • (2005) Medical Physics , vol.32 , Issue.8 , pp. 2557-2566
    • Chibani, O.1    Williamson, J.F.2    Todor, D.3
  • 13
    • 33845316456 scopus 로고    scopus 로고
    • 192Ir for HDR brachytherapy of the breast, accounting for the effect of finite patient dimensions and tissue inhomogeneities
    • DOI 10.1118/1.2392408, 035612MPH
    • G. Lymperopoulou, P. Papagiannis, A. Angelopoulos, P. Karaiskos, E. Georgiou, and D. Baltas, " A dosimetric comparison of 169Yb and 192Ir for HDR brachytherapy of the breast, accounting for the effect of finite patient dimensions and tissue inhomogeneities.," Med. Phys. MPHYA6 0094-2405 33, 4583-4589 (2006). 10.1118/1.2392408 (Pubitemid 44868095)
    • (2006) Medical Physics , vol.33 , Issue.12 , pp. 4583-4589
    • Lymperopoulou, G.1    Papagiannis, P.2    Angelopoulos, A.3    Karaiskos, P.4    Georgiou, E.5    Baltas, D.6
  • 14
    • 33644999267 scopus 로고    scopus 로고
    • MCPI: A sub-minute Monte Carlo dose calculation engine for prostate implants
    • MPHYA6 0094-2405,. 10.1118/1.2126822
    • O. Chibani and J. F. Williamson, " MCPI: A sub-minute Monte Carlo dose calculation engine for prostate implants.," Med. Phys. MPHYA6 0094-2405 32, 3688-3698 (2005). 10.1118/1.2126822
    • (2005) Med. Phys. , vol.32 , pp. 3688-3698
    • Chibani, O.1    Williamson, J.F.2
  • 15
    • 56749095583 scopus 로고    scopus 로고
    • 103Pd eye plaque brachytherapy
    • MPHYA6 0094-2405,. 10.1118/1.3002412
    • 103Pd eye plaque brachytherapy.," Med. Phys. MPHYA6 0094-2405 35, 5530-5543 (2008). 10.1118/1.3002412
    • (2008) Med. Phys. , vol.35 , pp. 5530-5543
    • Thomson, R.M.1    Taylor, R.E.P.2    Rogers, D.W.O.3
  • 16
    • 85024783701 scopus 로고    scopus 로고
    • SU-FF-T-113: BrachyDose: A new fast Monte Carlo code for brachytherapy calculations
    • MPHYA6 0094-2405,. 10.1118/1.2241038
    • G. Yegin, R. Taylor, and D. Rogers, " SU-FF-T-113: BrachyDose: A new fast Monte Carlo code for brachytherapy calculations.," Med. Phys. MPHYA6 0094-2405 33, 2074-2075 (2006). 10.1118/1.2241038
    • (2006) Med. Phys. , vol.33 , pp. 2074-2075
    • Yegin, G.1    Taylor, R.2    Rogers, D.3
  • 17
    • 0038171472 scopus 로고    scopus 로고
    • 192Ir brachytherapy treatment planning
    • DOI 10.1088/0031-9155/48/11/310, PII S0031915503578393
    • G. Anagnostopoulos, D. Baltas, P. Karaiskos, E. Pantelis, P. Papagiannis, and L. Sakelliou, " An analytical dosimetry model as a step towards accounting for inhomogeneities and bounded geometries in 192Ir brachytherapy treatment planning.," Phys. Med. Biol. PHMBA7 0031-9155 48, 1625-1647 (2003). 10.1088/0031-9155/48/11/310 (Pubitemid 36713340)
    • (2003) Physics in Medicine and Biology , vol.48 , Issue.11 , pp. 1625-1647
    • Anagnostopoulos, G.1    Baltas, D.2    Karaiskos, P.3    Pantelis, E.4    Papagiannis, P.5    Sakelliou, L.6
  • 18
    • 44649200461 scopus 로고    scopus 로고
    • BrachyGUI: An adjunct to an accelerated Monte Carlo photon transport code for patient-specific brachytherapy dose calculations and analysis
    • JPCSDZ 1742-6588,. 10.1088/1742-6596/102/1/012018
    • E. Poon, Y. Le, J. F. Williamson, and F. Verhaegen, " BrachyGUI: An adjunct to an accelerated Monte Carlo photon transport code for patient-specific brachytherapy dose calculations and analysis.," J. Phys.: Conf. Ser. JPCSDZ 1742-6588 102, 012018 (2008). 10.1088/1742-6596/102/1/012018
    • (2008) J. Phys.: Conf. Ser. , vol.102 , pp. 012018
    • Poon, E.1    Le, Y.2    Williamson, J.F.3    Verhaegen, F.4
  • 19
    • 54049155205 scopus 로고    scopus 로고
    • Patient-specific Monte Carlo dose calculations for high-dose-rate endorectal brachytherapy with shielded intracavitary applicator
    • IOBPD3 0360-3016,. 10.1016/j.ijrob2008.07.029
    • E. Poon, J. F. Williamson, T. Vuong, and F. Verhaegen, " Patient-specific Monte Carlo dose calculations for high-dose-rate endorectal brachytherapy with shielded intracavitary applicator.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 72, 1259-1266 (2008). 10.1016/j.ijrobp. 2008.07.029
    • (2008) Int. J. Radiat. Oncol., Biol., Phys. , vol.72 , pp. 1259-1266
    • Poon, E.1    Williamson, J.F.2    Vuong, T.3    Verhaegen, F.4
  • 20
    • 0033743901 scopus 로고    scopus 로고
    • The collapsed cone superposition algorithm applied to scatter dose calculations in brachytherapy
    • DOI 10.1118/1.1290485, PII S0094240500002108
    • A. K. Carlsson and A. Ahnesjo, " The collapsed cone superposition algorithm applied to scatter dose calculations in brachytherapy.," Med. Phys. MPHYA6 0094-2405 27, 2320-2332 (2000). 10.1118/1.1290485 (Pubitemid 30807446)
    • (2000) Medical Physics , vol.27 , Issue.10 , pp. 2320-2332
    • Carlsson, A.K.1    Ahnesjo, A.2
  • 21
    • 41449109056 scopus 로고    scopus 로고
    • Optimization of the computational efficiency of a 3D, collapsed cone dose calculation algorithm for brachytherapy
    • MPHYA6 0094-2405,. 10.1118/1.2889777
    • A. Carlsson Tedgren and A. Ahnesjo, " Optimization of the computational efficiency of a 3D, collapsed cone dose calculation algorithm for brachytherapy.," Med. Phys. MPHYA6 0094-2405 35, 1611-1618 (2008). 10.1118/1.2889777
    • (2008) Med. Phys. , vol.35 , pp. 1611-1618
    • Carlsson Tedgren, A.1    Ahnesjo, A.2
  • 22
    • 0033744897 scopus 로고    scopus 로고
    • 192Ir source by the multigroup discrete ordinates method
    • DOI 10.1118/1.1308279, PII S0094240500015108
    • 192Ir source by the multigroup discrete ordinates method.," Med. Phys. MPHYA6 0094-2405 27, 2307-2319 (2000). 10.1118/1.1308279 (Pubitemid 30807445)
    • (2000) Medical Physics , vol.27 , Issue.10 , pp. 2307-2319
    • Daskalov, G.M.1    Baker, R.S.2    Rogers, D.W.O.3    Williamson, J.F.4
  • 23
    • 0036171750 scopus 로고    scopus 로고
    • 125I 6702 seed dose distributions using a broad energy-group cross section representation
    • DOI 10.1118/1.1429238
    • 125I 6702 seed dose distributions using a broad energy-group cross section representation.," Med. Phys. MPHYA6 0094-2405 29, 113-124 (2002). 10.1118/1.1429238 (Pubitemid 34157984)
    • (2002) Medical Physics , vol.29 , Issue.2 , pp. 113-124
    • Daskalov, G.M.1    Baker, R.S.2    Rogers, D.W.O.3    Williamson, J.F.4
  • 24
    • 33646014420 scopus 로고    scopus 로고
    • Comparison of a finite-element multigroup discrete-ordinates code with Monte Carlo for radiotherapy calculations
    • PHMBA7 0031-9155,. 10.1088/0031-9155/51/9/010
    • K. A. Gifford, J. L. Horton, T. A. Wareing, G. Failla, and F. Mourtada, " Comparison of a finite-element multigroup discrete-ordinates code with Monte Carlo for radiotherapy calculations.," Phys. Med. Biol. PHMBA7 0031-9155 51, 2253-2265 (2006). 10.1088/0031-9155/51/9/010
    • (2006) Phys. Med. Biol. , vol.51 , pp. 2253-2265
    • Gifford, K.A.1    Horton, J.L.2    Wareing, T.A.3    Failla, G.4    Mourtada, F.5
  • 25
    • 44349099242 scopus 로고    scopus 로고
    • Optimization of deterministic transport parameters for the calculation of the dose distribution around a high dose-rate 192Ir brachytherapy source
    • DOI 10.1118/1.2919074
    • K. A. Gifford, M. J. Price, J. L. Horton, Jr., T. A. Wareing, and F. Mourtada, " Optimization of deterministic transport parameters for the calculation of the dose distribution around a high dose-rate 192Ir brachytherapy source.," Med. Phys. MPHYA6 0094-2405 35, 2279-2285 (2008). 10.1118/1.2919074 (Pubitemid 351748634)
    • (2008) Medical Physics , vol.35 , Issue.6 , pp. 2279-2285
    • Gifford, K.A.1    Price, M.J.2    Horton Jr., J.L.3    Wareing, T.A.4    Mourtada, F.5
  • 29
    • 50449095484 scopus 로고    scopus 로고
    • An EGSnrc Monte Carlo-calculated database of TG-43 parameters
    • MPHYA6 0094-2405,. 10.1118/1.2965360
    • R. E. Taylor and D. W. Rogers, " An EGSnrc Monte Carlo-calculated database of TG-43 parameters.," Med. Phys. MPHYA6 0094-2405 35, 4228-4241 (2008). 10.1118/1.2965360
    • (2008) Med. Phys. , vol.35 , pp. 4228-4241
    • Taylor, R.E.1    Rogers, D.W.2
  • 31
    • 85027228272 scopus 로고    scopus 로고
    • See supplementary material E-MPHYA6-37-041002 for the comparison between MC and TPS results for the GMPlus HDR and PDR sources centered in the 15 cm radius water phantom in terms of the TG-43 formalism as well as in terms of dose rate distributions per unit air kerma strength.
    • See supplementary material E-MPHYA6-37-041002 for the comparison between MC and TPS results for the GMPlus HDR and PDR sources centered in the 15 cm radius water phantom in terms of the TG-43 formalism as well as in terms of dose rate distributions per unit air kerma strength.
  • 32
    • 33644511162 scopus 로고    scopus 로고
    • Los Alamos National Laboratory Report No. LA-CP-05-0369.
    • D. B. Pelowitz, " MCNPX User's Manual Version 2.5.0. " Los Alamos National Laboratory Report No. LA-CP-05-0369, 2005.
    • (2005) MCNPX User's Manual Version 2.5.0
    • Pelowitz, D.B.1
  • 35
    • 0018342717 scopus 로고    scopus 로고
    • Specific gamma-ray constant and exposure rate constant of 192Ir
    • MPHYA6 0094-2405,. 10.1118/1.594551
    • G. P. Glasgow and L. T. Dillman, " Specific gamma-ray constant and exposure rate constant of 192Ir.," Med. Phys. MPHYA6 0094-2405 6, 49-52 (1999). 10.1118/1.594551
    • (1999) Med. Phys. , vol.6 , pp. 49-52
    • Glasgow, G.P.1    Dillman, L.T.2
  • 36
    • 0032794599 scopus 로고    scopus 로고
    • 192Ir high dose rate brachytherapy source
    • DOI 10.1118/1.598645
    • P. Karaiskos, A. Angelopoulos, P. Baras, L. Sakelliou, P. Sandilos, K. Dardoufas, and L. Vlachos, " A Monte Carlo investigation of the dosimetric characteristics of the VariSource 192Ir high dose rate brachytherapy source.," Med. Phys. MPHYA6 0094-2405 26, 1498-1502 (1999). 10.1118/1.598645 (Pubitemid 29402260)
    • (1999) Medical Physics , vol.26 , Issue.8 , pp. 1498-1502
    • Karaiskos, P.1    Angelopoulos, A.2    Baras, P.3    Sakelliou, L.4    Sandilos, P.5    Dardoufas, K.6    Vlachos, L.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.