메뉴 건너뛰기




Volumn 48, Issue 11, 2003, Pages 1625-1647

An analytical dosimetry model as a step towards accounting for inhomogeneities and bounded geometries in 192Ir brachytherapy treatment planning

Author keywords

[No Author keywords available]

Indexed keywords

ATTENUATION; MATHEMATICAL MODELS; MONTE CARLO METHODS; PHOTONS; WATER;

EID: 0038171472     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/48/11/310     Document Type: Article
Times cited : (34)

References (38)
  • 2
    • 0025904558 scopus 로고
    • Accurate Monte Carlo calculations of the combined attenuation and build-up factors, for energies (20-1500 keV) and distances (0-10 cm) relevant in brachytherapy
    • Angelopoulos A, Perris A, Sakellariou K, Sakelliou L, Sarigiannis K and Zarris G 1991 Accurate Monte Carlo calculations of the combined attenuation and build-up factors, for energies (20-1500 keV) and distances (0-10 cm) relevant in brachytherapy Phys. Med. Biol. 36 763-78
    • (1991) Phys. Med. Biol. , vol.36 , pp. 763-778
    • Angelopoulos, A.1    Perris, A.2    Sakellariou, K.3    Sakelliou, L.4    Sarigiannis, K.5    Zarris, G.6
  • 4
    • 0003395844 scopus 로고    scopus 로고
    • McNp™ - A general Monte Carlo N-particle transport code: Version 4C
    • Los Alamos, NM: Los Alamos National Laboratory
    • Briesmeister J F (ed) 2000 McNp™ - A general Monte Carlo N-particle transport code: version 4C Report LA-13709-M (Los Alamos, NM: Los Alamos National Laboratory)
    • (2000) Report LA-13709-M
    • Briesmeister, J.F.1
  • 5
    • 0033954079 scopus 로고    scopus 로고
    • Point kernels and superposition methods for scatter dose calculations in brachytherapy
    • Carlsson A K and Ahnesjö A 2000 Point kernels and superposition methods for scatter dose calculations in brachytherapy Phys. Med. Biol. 45 357-82
    • (2000) Phys. Med. Biol. , vol.45 , pp. 357-382
    • Carlsson, A.K.1    Ahnesjö, A.2
  • 6
    • 0035142091 scopus 로고    scopus 로고
    • Dose rate constant and energy spectrum of interstitial brachytherapy sources
    • Chen Z and Nath R 2001 Dose rate constant and energy spectrum of interstitial brachytherapy sources Med. Phys. 28 86-96
    • (2001) Med. Phys. , vol.28 , pp. 86-96
    • Chen, Z.1    Nath, R.2
  • 8
    • 0031861576 scopus 로고    scopus 로고
    • Analytical approach to heterogeneity correction factor calculation for brachytherapy
    • Daskalov G M, Kirov A S and Williamson J F 1998a Analytical approach to heterogeneity correction factor calculation for brachytherapy Med. Phys. 25 722-35
    • (1998) Med. Phys. , vol.25 , pp. 722-735
    • Daskalov, G.M.1    Kirov, A.S.2    Williamson, J.F.3
  • 9
    • 0031739032 scopus 로고    scopus 로고
    • Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source
    • Daskalov G M, Löffler E and Williamson J F 1998b Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source Med. Phys. 25 2200-08
    • (1998) Med. Phys. , vol.25 , pp. 2200-2208
    • Daskalov, G.M.1    Löffler, E.2    Williamson, J.F.3
  • 10
    • 0037149981 scopus 로고    scopus 로고
    • An analysis of MCNP cross-sections and tally methods for low-energy photon emitters
    • DeMarco J, Wallace R E and Boedecker K 2002 An analysis of MCNP cross-sections and tally methods for low-energy photon emitters Phys. Med. Biol. 47 1321-32
    • (2002) Phys. Med. Biol. , vol.47 , pp. 1321-1332
    • DeMarco, J.1    Wallace, R.E.2    Boedecker, K.3
  • 13
    • 0037034119 scopus 로고    scopus 로고
    • Accelerated Monte Carlo based dose calculations for brachytherapy planning using correlated sampling
    • Hedtjarn H, Carlsson G A and Williamson J F 2002 Accelerated Monte Carlo based dose calculations for brachytherapy planning using correlated sampling Phys. Med. Biol. 47 351-76
    • (2002) Phys. Med. Biol. , vol.47 , pp. 351-376
    • Hedtjarn, H.1    Carlsson, G.A.2    Williamson, J.F.3
  • 14
    • 2742546324 scopus 로고
    • Relativistic atomic form factors and photon coherent scattering cross sections
    • Hubbell J H and Overbo I 1979 Relativistic atomic form factors and photon coherent scattering cross sections J. Phys. Chem. Ref. Data 8 69-105
    • (1979) J. Phys. Chem. Ref. Data , vol.8 , pp. 69-105
    • Hubbell, J.H.1    Overbo, I.2
  • 15
    • 0003523753 scopus 로고
    • National Institute of Standards and Technology, Gaithersburg, MD. Originally published as NISTIR 5632, National Institute of Standards and Technology, Gaithersburg, MD
    • Hubbell J H and Seltzer S M 1995 Tables of x-ray mass attenuation coefficients and mass energy-absorption coefficients (version 1.03) webpage http://physics.nist.gov/xaamdi. National Institute of Standards and Technology, Gaithersburg, MD. Originally published as NISTIR 5632, National Institute of Standards and Technology, Gaithersburg, MD
    • (1995) Tables of X-ray Mass Attenuation Coefficients and Mass Energy-absorption Coefficients (Version 1.03)
    • Hubbell, J.H.1    Seltzer, S.M.2
  • 23
    • 0030731269 scopus 로고    scopus 로고
    • Two-dimensional scatter integration method for brachytherapy dose calculations in 3D geometry
    • Kirov A S and Williamson J F 1997 Two-dimensional scatter integration method for brachytherapy dose calculations in 3D geometry Phys. Med. Biol. 42 2119-35
    • (1997) Phys. Med. Biol. , vol.42 , pp. 2119-2135
    • Kirov, A.S.1    Williamson, J.F.2
  • 24
    • 0029944194 scopus 로고    scopus 로고
    • Measurement and calculation of the heterogeneity correction factors for an Ir-192 high dose-rate brachytherapy source behind tungsten alloy and steel shields
    • Kirov A S, Williamson J F, Meigooni A S and Zhu Y 1996 Measurement and calculation of the heterogeneity correction factors for an Ir-192 high dose-rate brachytherapy source behind tungsten alloy and steel shields Med. Phys. 23 911-19
    • (1996) Med. Phys. , vol.23 , pp. 911-919
    • Kirov, A.S.1    Williamson, J.F.2    Meigooni, A.S.3    Zhu, Y.4
  • 25
    • 0035915799 scopus 로고    scopus 로고
    • Quality control in interstitial brachytherapy of the breast using pulsed dose rate: Treatment planning and dose delivery with an Ir-192 afterloading system
    • Mangold C A, Rijnders A, Georg D, Van Limbergen E, Pötter R and Huyskens D 2001 Quality control in interstitial brachytherapy of the breast using pulsed dose rate: treatment planning and dose delivery with an Ir-192 afterloading system Radiother. Oncol. 58 43-51
    • (2001) Radiother. Oncol. , vol.58 , pp. 43-51
    • Mangold, C.A.1    Rijnders, A.2    Georg, D.3    Van Limbergen, E.4    Pötter, R.5    Huyskens, D.6
  • 26
    • 0028919251 scopus 로고
    • Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group 43
    • Nath R, Anderson L, Luxton G, Weaver K, Williamson J F and Meigooni A S 1995 Dosimetry of interstitial brachytherapy sources: recommendations of the AAPM Radiation Therapy Committee Task Group 43 Med. Phys. 22 209-34
    • (1995) Med. Phys. , vol.22 , pp. 209-234
    • Nath, R.1    Anderson, L.2    Luxton, G.3    Weaver, K.4    Williamson, J.F.5    Meigooni, A.S.6
  • 29
    • 0029895014 scopus 로고    scopus 로고
    • 192Ir source using a primary and scatter dose separation technique
    • 192Ir source using a primary and scatter dose separation technique Phys. Med. Biol. 41 1007-24
    • (1996) Phys. Med. Biol. , vol.41 , pp. 1007-1024
    • Russell, K.R.1    Ahnesjö, A.2
  • 31
    • 3042914196 scopus 로고
    • X-ray attenuation cross sections for energies 100 eV to 100 keV and elements Z = 1 to Z = 92
    • Saloman E B, Hubbell J H and Scofield J H 1988 X-ray attenuation cross sections for energies 100 eV to 100 keV and elements Z = 1 to Z = 92 At. Data Nucl. Data Tables 38 1-197
    • (1988) At. Data Nucl. Data Tables , vol.38 , pp. 1-197
    • Saloman, E.B.1    Hubbell, J.H.2    Scofield, J.H.3
  • 35
    • 0025884060 scopus 로고
    • A convolution algorithm for brachytherapy dose computations in heterogeneous geometries
    • Williamson J F, Baker P S and Zuofeng Li 1991 A convolution algorithm for brachytherapy dose computations in heterogeneous geometries Med. Phys. 18 256-1264
    • (1991) Med. Phys. , vol.18 , pp. 256-1264
    • Williamson, J.F.1    Baker, P.S.2    Li, Z.3
  • 37
    • 0027462867 scopus 로고
    • One dimensional scatter-subtraction method for brachytherapy dose calculation near bounded heterogeneities
    • Williamson J F, Li Z and Wong J W 1993a One dimensional scatter-subtraction method for brachytherapy dose calculation near bounded heterogeneities Med. Phys. 20 233-44
    • (1993) Med. Phys. , vol.20 , pp. 233-244
    • Williamson, J.F.1    Li, Z.2    Wong, J.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.