메뉴 건너뛰기




Volumn 32, Issue 8, 2005, Pages 2557-2566

Dosimetric effects of seed anisotropy and interseed attenuation for 103Pd and 125I prostate implants

Author keywords

[No Author keywords available]

Indexed keywords

ANISOTROPY; LIGHT SCATTERING; PHOTONS; UROLOGY;

EID: 23944509702     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1897466     Document Type: Article
Times cited : (56)

References (40)
  • 1
    • 0020642751 scopus 로고
    • Transpireneal 125-iodine seed implantation in prostatic cancer guided by transrectal ultrasonography
    • H. H. Holm et al., "Transpireneal 125-iodine seed implantation in prostatic cancer guided by transrectal ultrasonography," J. Urol. (Baltimore) 130, 283-286 (1983).
    • (1983) J. Urol. (Baltimore) , vol.130 , pp. 283-286
    • Holm, H.H.1
  • 2
    • 0026529439 scopus 로고
    • Treatment of localized prostatic carcinoma using the transrectal ultrasound guided transperineal implantation technique
    • P. L. Vijverberg, K. H. Kurth, L. E. Blank, N. F. Dabhoiwala, T. H. De Reijke, and K. Koedoor, "Treatment of localized prostatic carcinoma using the transrectal ultrasound guided transperineal implantation technique." Eur. Urol. 21, 35-41 (1992).
    • (1992) Eur. Urol. , vol.21 , pp. 35-41
    • Vijverberg, P.L.1    Kurth, K.H.2    Blank, L.E.3    Dabhoiwala, N.F.4    De Reijke, T.H.5    Koedoor, K.6
  • 3
    • 0028897357 scopus 로고
    • Detailed preliminary analysis of 125 iodine implantation for localized prostate cancer using percutaneous approach
    • K. W. Kaye, D. J. Olson, and J. T. Payne, "Detailed preliminary analysis of 125 iodine implantation for localized prostate cancer using percutaneous approach," J. Urol. (Baltimore) 153, 1020-1025 (1995).
    • (1995) J. Urol. (Baltimore) , vol.153 , pp. 1020-1025
    • Kaye, K.W.1    Olson, D.J.2    Payne, J.T.3
  • 5
    • 0030764130 scopus 로고    scopus 로고
    • Interstitial iodine-125 radiation without adjuvant therapy in the treatment of clinically localized prostate carcinoma
    • H. Radge, J. C. Blasko, P. D. Grimm, G. M. Kenny, J. E. Sylvester, D. C. Hoak, K. Landin, and W. Cavanagh, "Interstitial iodine-125 radiation without adjuvant therapy in the treatment of clinically localized prostate carcinoma," Cancer (N.Y.) 80, 442-453 (1997).
    • (1997) Cancer (N.Y.) , vol.80 , pp. 442-453
    • Radge, H.1    Blasko, J.C.2    Grimm, P.D.3    Kenny, G.M.4    Sylvester, J.E.5    Hoak, D.C.6    Landin, K.7    Cavanagh, W.8
  • 6
    • 0033976043 scopus 로고    scopus 로고
    • The american brachytherapy society recommendations for permanent prostate brachytherapy postimplant dosimetric analysis
    • S. Nag, W. Bice, K. Dewingaert, B. Prestige, R. Stock, and Y. Yu, "The american brachytherapy society recommendations for permanent prostate brachytherapy postimplant dosimetric analysis," Int. J. Radiat. Oncol., Biol., Phys. 46, 221-230 (2000).
    • (2000) Int. J. Radiat. Oncol., Biol., Phys. , vol.46 , pp. 221-230
    • Nag, S.1    Bice, W.2    Dewingaert, K.3    Prestige, B.4    Stock, R.5    Yu, Y.6
  • 8
    • 0032753788 scopus 로고    scopus 로고
    • Permanent prostate seed implant brachytherapy: Report of the American Association of Physicists in Medicine Task Group No. 64
    • Y Yu, L. L. Anderson, Z. Li. D. E. Mellenberg, R. Nath, M. C. Schell, F. M. Waterman, A. Wu, and J. C. Blasko, "Permanent prostate seed implant brachytherapy: Report of the American Association of Physicists in Medicine Task Group No. 64." Med. Phys. 26, 2054-2076 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 2054-2076
    • Yu, Y.1    Anderson, L.L.2    Li, Z.3    Mellenberg, D.E.4    Nath, R.5    Schell, M.C.6    Waterman, F.M.7    Wu, A.8    Blasko, J.C.9
  • 9
    • 0028919251 scopus 로고
    • Dosimetry of interstitial brachytherapy sources: Recom-mendations of the AAPM Radiation Therapy Committee Task Group No. 43
    • R. Nath, L. L. Anderson, G. Luxton, K. A. Weaver, J. F. Williamson, and A. S. Meigooni, "Dosimetry of interstitial brachytherapy sources: Recom-mendations of the AAPM Radiation Therapy Committee Task Group No. 43," Med. Phys. 22, 209-234 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 209-234
    • Nath, R.1    Anderson, L.L.2    Luxton, G.3    Weaver, K.A.4    Williamson, J.F.5    Meigooni, A.S.6
  • 10
    • 0026652744 scopus 로고
    • Tissue inhomogeneity correction for brachytherapy sources in a homogeneous phantom with cylindrical symmetry
    • A. S. Meigooni and R. Nath, "Tissue inhomogeneity correction for brachytherapy sources in a homogeneous phantom with cylindrical symmetry." Med. Phys. 19, 401-407 (1992).
    • (1992) Med. Phys. , vol.19 , pp. 401-407
    • Meigooni, A.S.1    Nath, R.2
  • 11
    • 0031861576 scopus 로고    scopus 로고
    • Analytical approach to heterogeneity correction factor calculation for brachytherapy
    • G. M. Daskalov, A. S. Kirov, and J. F. Williamson, "Analytical approach to heterogeneity correction factor calculation for brachytherapy," Med. Phys. 25, 722-735 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 722-735
    • Daskalov, G.M.1    Kirov, A.S.2    Williamson, J.F.3
  • 12
    • 0029944194 scopus 로고    scopus 로고
    • Measurement and calculation of heterogeneity correction factors for an Ir-192 high dose-rate brachytherapy source behind tungsten alloy and steel shields
    • A. S. Kirov, J. F. Williamson, A. S. Meigooni, and Y. Zhu, "Measurement and calculation of heterogeneity correction factors for an Ir-192 high dose-rate brachytherapy source behind tungsten alloy and steel shields," Med. Phys. 23, 911-919 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 911-919
    • Kirov, A.S.1    Williamson, J.F.2    Meigooni, A.S.3    Zhu, Y.4
  • 14
    • 0024461534 scopus 로고
    • The accuracy of single-seed dose super-position for 1-125 implants
    • G. S. Burns and D. E. Raeside, "The accuracy of single-seed dose super-position for 1-125 implants," Med. Phys. 16, 627-6632 (1989).
    • (1989) Med. Phys. , vol.16 , pp. 627-6632
    • Burns, G.S.1    Raeside, D.E.2
  • 15
    • 0026749829 scopus 로고
    • Interseed effects on dose for 1251 brachytherapy implants
    • A. S. Meigooni, J. A. Meli, and R. Nath, "Interseed effects on dose for 1251 brachytherapy implants," Med. Phys. 19, 385-390 (1992).
    • (1992) Med. Phys. , vol.19 , pp. 385-390
    • Meigooni, A.S.1    Meli, J.A.2    Nath, R.3
  • 19
    • 0033678807 scopus 로고    scopus 로고
    • 90Y and 192Ir SS sources for intravascular brachytherapy
    • 90Y and 192Ir SS sources for intravascular brachytherapy," Med. Phys. 27, 2528-2535 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 2528-2535
    • Wang, R.1    Li, X.A.2
  • 20
    • 0031739691 scopus 로고    scopus 로고
    • Calculated dosimetric parameters of the loGold 1251 source model 3631-A
    • J. G. Wierzbicki, M. J. Rivard, D. S. Waid, and V. E. Arterbery, "Calculated dosimetric parameters of the loGold 1251 source model 3631-A," Med. Phys. 25, 2197-2199 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 2197-2199
    • Wierzbicki, J.G.1    Rivard, M.J.2    Waid, D.S.3    Arterbery, V.E.4
  • 21
    • 0037241039 scopus 로고    scopus 로고
    • IVBTMC, a new general dose calculation tool for intravascular brachytherapy
    • O. Chibani and X. A. Li, "IVBTMC, A New General Dose Calculation Tool for Intravascular Brachytherapy," Med. Phys. 30, 44-54 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 44-54
    • Chibani, O.1    Li, X.A.2
  • 23
    • 0035055314 scopus 로고    scopus 로고
    • Monte Carlo calculations of AAPM Task Group Report No. 43 dosimetry parameters for the MED3631-A/M 1251 source
    • M. J. Rivard, "Monte Carlo calculations of AAPM Task Group Report No. 43 dosimetry parameters for the MED3631-A/M 1251 source," Med. Phys. 28, 629-637 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 629-637
    • Rivard, M.J.1
  • 24
    • 0035190490 scopus 로고    scopus 로고
    • Dosimetric study of the new Intersource 1251 iodine seed
    • B. Reniers, S. Vymckier, and P. Scalliet, "Dosimetric study of the new Intersource 1251 iodine seed," Med. Phys. 28, 2285-2288 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 2285-2288
    • Reniers, B.1    Vymckier, S.2    Scalliet, P.3
  • 25
    • 0037391530 scopus 로고    scopus 로고
    • 103Pd sources using an updated cross section library for the MCNP Monte Carlo transport code
    • 103Pd sources using an updated cross section library for the MCNP Monte Carlo transport code," Med. Phys. 30, 701-710 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 701-710
    • Bohm, T.D.1    Deluca, P.2    Dewerd, L.A.3
  • 26
    • 0035999411 scopus 로고    scopus 로고
    • Monte Carlo dose calculations in homogeneous media and at interfaces: A comparison between GEPTS, EGSnrc, MCNP and measurements
    • O. Chibani and X. A. Li, "Monte Carlo dose calculations in homogeneous media and at interfaces: A comparison between GEPTS, EGSnrc, MCNP and measurements," Med. Phys. 29, 835-847 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 835-847
    • Chibani, O.1    Li, X.A.2
  • 27
    • 0031832848 scopus 로고    scopus 로고
    • Experimental and Monte Carlo dosimetry of the Henschke applicator for high dose-rate 192Ir remote afterloading
    • Y. Watanabe, J. Roy, P. J. Harrington, and L. L. Anderson, "Experimental and Monte Carlo dosimetry of the Henschke applicator for high dose-rate 192Ir remote afterloading," Med. Phys. 25, 736-745 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 736-745
    • Watanabe, Y.1    Roy, J.2    Harrington, P.J.3    Anderson, L.L.4
  • 28
    • 0035117289 scopus 로고    scopus 로고
    • Monte Carlo dose calculations of beta-emitting for intravascular brachytherapy: A comparison between EGS4, EGSnrc, and MCNP
    • R. Wang and X. A. Li, "Monte Carlo dose calculations of beta-emitting for intravascular brachytherapy: A comparison between EGS4, EGSnrc, and MCNP," Med. Phys. 28, 134-141 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 134-141
    • Wang, R.1    Li, X.A.2
  • 29
    • 0036118007 scopus 로고    scopus 로고
    • Dosimetric effects of source-offset in intravascular brachytherapy
    • O. Chibani and X. A. Li, "Dosimetric effects of source-offset in intravascular brachytherapy," Med. Phys. 29, 530-537 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 530-537
    • Chibani, O.1    Li, X.A.2
  • 31
    • 2742546324 scopus 로고
    • Relativistic atomic form factors and photon coherent cross sections
    • J. H. Hubbel and I. OØverbo. "Relativistic atomic form factors and photon coherent cross sections," J. Phys. Chem. Ref. Data 8, 69-105 (1979).
    • (1979) J. Phys. Chem. Ref. Data , vol.8 , pp. 69-105
    • Hubbel, J.H.1    Oøverbo, I.2
  • 34
    • 0037034119 scopus 로고    scopus 로고
    • Accelerated Monte Carlo based dose calculations for brachytherapy planning using correlated sampling
    • H. Hedtjarn, G. A. Carlson, and J. F. Williamson, "Accelerated Monte Carlo based dose calculations for brachytherapy planning using correlated sampling," Phys. Med. Biol. 47, 351-376 (2002).
    • (2002) Phys. Med. Biol. , vol.47 , pp. 351-376
    • Hedtjarn, H.1    Carlson, G.A.2    Williamson, J.F.3
  • 35
    • 0034004934 scopus 로고    scopus 로고
    • 103Pd interstitial brachytherapy source
    • 103Pd interstitial brachytherapy source," Med. Phys. 27, 643-654 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 643-654
    • Williamson, J.F.1
  • 38
    • 0031950887 scopus 로고    scopus 로고
    • CT-based Monte Carlo simulation tool for dosimetry planning and analysis
    • J. J. Demarco, T. D. Solberg, and J. B. Smathers, "CT-based Monte Carlo simulation tool for dosimetry planning and analysis," Med. Phys. 25, 1-11 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 1-11
    • Demarco, J.J.1    Solberg, T.D.2    Smathers, J.B.3
  • 40
    • 4344625983 scopus 로고    scopus 로고
    • Dose perturbation effects in prostate seed implant brachytherapy with 1-125
    • P Mobit and I. Badragan, "Dose perturbation effects in prostate seed implant brachytherapy with 1-125," Phys. Med. Biol. 49, 3171-3178 (2004).
    • (2004) Phys. Med. Biol. , vol.49 , pp. 3171-3178
    • Mobit, P.1    Badragan, I.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.