메뉴 건너뛰기




Volumn 56, Issue 10, 2009, Pages 2518-2528

Fluorescence Spectroscopy: An Adjunct Diagnostic Tool to Image-Guided Core Needle Biopsy of the Breast

Author keywords

Biopsy; breast cancer; fluorescence; spectroscopy

Indexed keywords

ALGORITHM; AREA UNDER THE CURVE; ARTICLE; ARTIFICIAL INTELLIGENCE; BREAST; BREAST TUMOR; COMPUTER ASSISTED SURGERY; EQUIPMENT DESIGN; FEMALE; FIBER OPTICS; HUMAN; INSTRUMENTATION; METHODOLOGY; NEEDLE BIOPSY; NONPARAMETRIC TEST; PATHOLOGY; PRINCIPAL COMPONENT ANALYSIS; RECEIVER OPERATING CHARACTERISTIC; REGRESSION ANALYSIS; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; SPECTROFLUOROMETRY; STATISTICAL MODEL;

EID: 74049125956     PISSN: 00189294     EISSN: 15582531     Source Type: Journal    
DOI: 10.1109/TBME.2009.2015936     Document Type: Article
Times cited : (26)

References (31)
  • 1
    • 0025886119 scopus 로고
    • Nonpalpable breast lesions: Stereotactic automated large-core biopsies
    • S. H. Parker, J. D. Lovin, W. E. Jobe, B. J. Burke, K. D. Hopper, and W. F. Yakes “Nonpalpable breast lesions: Stereotactic automated large-core biopsies,” Radiology, vol. 180, pp. 403–407, 1991.
    • (1991) Radiology , vol.180 , pp. 403-407
    • Parker, S.H.1    Lovin, J.D.2    Jobe, W.E.3    Burke, B.J.4    Hopper, K.D.5    Yakes, W.F.6
  • 5
    • 0027170041 scopus 로고
    • Nonpalpable breast lesions: Correlation of stereotaxic large-core needle biopsy and surgical biopsy results
    • E. L. Elvecrog, M. C. Lechner, and M. T. Nelson “Nonpalpable breast lesions: Correlation of stereotaxic large-core needle biopsy and surgical biopsy results,” Radiology, vol. 188, pp. 453–455, 1993.
    • (1993) Radiology , vol.188 , pp. 453-455
    • Elvecrog, E.L.1    Lechner, M.C.2    Nelson, M.T.3
  • 6
    • 0030068037 scopus 로고    scopus 로고
    • Nondi-agnostic stereotaxic core breast biopsy: Results of rebiopsy
    • D. D. Dershaw, E. A. Morris, L. Liberman, and A. F. Abramson “Nondi-agnostic stereotaxic core breast biopsy: Results of rebiopsy,” Radiology, vol. 198, pp. 323–325, 1996.
    • (1996) Radiology , vol.198 , pp. 323-325
    • Dershaw, D.D.1    Morris, E.A.2    Liberman, L.3    Abramson, A.F.4
  • 7
    • 0032976596 scopus 로고    scopus 로고
    • Stereotactic, automated, large-core needle biopsy of nonpalpable breast lesions: False-negative and histologic underestimation rates after long-term follow-up
    • R. J. Jackman, K. W. Nowels, J. Rodriguez-Soto, F. A. Marzoni, Jr., S. I. Finkelstein, and M. J. Shepard “Stereotactic, automated, large-core needle biopsy of nonpalpable breast lesions: False-negative and histologic underestimation rates after long-term follow-up,” Radiology, vol. 210, pp. 799–805, 1999.
    • (1999) Radiology , vol.210 , pp. 799-805
    • Jackman, R.J.1    Nowels, K.W.2    Rodriguez-Soto, J.3    Marzoni, F.A.4    Finkelstein, S.I.5    Shepard, M.J.6
  • 11
    • 28544450612 scopus 로고    scopus 로고
    • Image-guided tissue sampling: Where radiology meets pathology
    • J. Parikh and R. Tickman, “Image-guided tissue sampling: Where radiology meets pathology,” Breast J., vol. 11, pp. 403–409, 2005.
    • (2005) Breast J. , vol.11 , pp. 403-409
    • Parikh, J.1    Tickman, R.2
  • 14
    • 0030345433 scopus 로고    scopus 로고
    • Quantitative optical spectroscopy for tissue diagnosis
    • R. Richards-Kortum and E. Sevick-Muraca “Quantitative optical spectroscopy for tissue diagnosis,” Annu. Rev. Phys. Chem., vol. 47, pp. 555–606, 1996.
    • (1996) Annu. Rev. Phys. Chem. , vol.47 , pp. 555-606
    • Richards-Kortum, R.1    Sevick-Muraca, E.2
  • 17
    • 34250204165 scopus 로고    scopus 로고
    • Feasibility of near-infrared diffuse optical spectroscopy on patients undergoing image-guided core-needle biopsy
    • B. Yu, E. S. Burnside, G. A. Sisney, J. M. Harter, C. Zhu, A. Dhalla, and N. Ramanujam, “Feasibility of near-infrared diffuse optical spectroscopy on patients undergoing image-guided core-needle biopsy,” Opt. Exp., vol. 15, pp. 7335–7350, 2007.
    • (2007) Opt. Exp. , vol.15 , pp. 7335-7350
    • Yu, B.1    Burnside, E.S.2    Sisney, G.A.3    Harter, J.M.4    Zhu, C.5    Dhalla, A.6    Ramanujam, N.7
  • 18
    • 0030900088 scopus 로고    scopus 로고
    • Ultraviolet and visible spectroscopies for tissue diagnostics: Fluorescence spectroscopy and elastic-scattering spectroscopy
    • I. J. Bigio and J. R. Mourant “Ultraviolet and visible spectroscopies for tissue diagnostics: Fluorescence spectroscopy and elastic-scattering spectroscopy,” Phys. Med. Biol., vol. 42, pp. 803–814, 1997.
    • (1997) Phys. Med. Biol. , vol.42 , pp. 803-814
    • Bigio, I.J.1    Mourant, J.R.2
  • 19
    • 0030856914 scopus 로고    scopus 로고
    • Breast cancer diagnosis using N2 laser excited autofluorescence spectroscopy
    • P. K. Gupta, S. K. Majumder, and A. Uppal, “Breast cancer diagnosis using N2 laser excited autofluorescence spectroscopy,” Lasers Surg. Med., vol. 21, pp. 417–422, 1997.
    • (1997) Lasers Surg. Med. , vol.21 , pp. 417-422
    • Gupta, P.K.1    Majumder, S.K.2    Uppal, A.3
  • 20
    • 0033004075 scopus 로고    scopus 로고
    • UV excited autofluorescence spectroscopy of human breast tissues for discriminating cancerous tissue from benign tumor and normal tissue
    • S. K. Majumder, P. K. Gupta, B. Jain, and A. Uppal “UV excited autofluorescence spectroscopy of human breast tissues for discriminating cancerous tissue from benign tumor and normal tissue,” Lasers Life Sci., vol. 8, pp. 249–264, 1999.
    • (1999) Lasers Life Sci. , vol.8 , pp. 249-264
    • Majumder, S.K.1    Gupta, P.K.2    Jain, B.3    Uppal, A.4
  • 21
    • 0142089669 scopus 로고    scopus 로고
    • Diagnosis of breast cancer using optical spectroscopy
    • G. M. Palmer and N. Ramanujam, “Diagnosis of breast cancer using optical spectroscopy,” Med. Laser Appl., vol. 18, pp. 233–248, 2003.
    • (2003) Med. Laser Appl. , vol.18 , pp. 233-248
    • Palmer, G.M.1    Ramanujam, N.2
  • 22
    • 0242269079 scopus 로고    scopus 로고
    • Comparison of multiexcitation fluorescence and diffuse reflectance spectroscopy for the diagnosis of breast cancer (March 2003)
    • Nov.
    • G. M. Palmer, C. Zhu, T. M. Breslin, F. Xu, K. W. Gilchrist, and N. Ramanujam, “Comparison of multiexcitation fluorescence and diffuse reflectance spectroscopy for the diagnosis of breast cancer (March 2003),” IEEE Trans. Biomed. Eng., vol. 50, no. 11, pp. 1233–1242, Nov. 2003.
    • (2003) IEEE Trans. Biomed. Eng. , vol.50 , Issue.11 , pp. 1233-1242
    • Palmer, G.M.1    Zhu, C.2    Breslin, T.M.3    Xu, F.4    Gilchrist, K.W.5    Ramanujam, N.6
  • 23
    • 24744465656 scopus 로고    scopus 로고
    • The use of a multi-separation fiber optic probe for the optical diagnosis of breast cancer
    • C. Zhu, G. M. Palmer, T. M. Breslin, F. Xu, and N. Ramanujam, “The use of a multi-separation fiber optic probe for the optical diagnosis of breast cancer,” J. Biomed. Opt., vol. 10, pp. 024032–1–024032-13, 2005.
    • (2005) J. Biomed. Opt. , vol.10 , pp. 024032-1-024032-13
    • Zhu, C.1    Palmer, G.M.2    Breslin, T.M.3    Xu, F.4    Ramanujam, N.5
  • 24
    • 0037592987 scopus 로고    scopus 로고
    • Experimental validation of Monte Carlo modeling of fluorescence in tissues in the UV-visible spectrum
    • Q. Liu, C. Zhu, and N. Ramanujam, “Experimental validation of Monte Carlo modeling of fluorescence in tissues in the UV-visible spectrum,” J. Biomed. Opt., vol. 8, pp. 223–236, 2003.
    • (2003) J. Biomed. Opt. , vol.8 , pp. 223-236
    • Liu, Q.1    Zhu, C.2    Ramanujam, N.3
  • 26
    • 33748056820 scopus 로고    scopus 로고
    • Diagnosis of breast cancer using diffuse reflectance spectroscopy: Comparison of a Monte Carlo versus partial least squares analysis based feature extraction technique
    • C. Zhu, G. M. Palmer, T. M. Breslin, J. Harter, and N. Ramanujam, “Diagnosis of breast cancer using diffuse reflectance spectroscopy: Comparison of a Monte Carlo versus partial least squares analysis based feature extraction technique,” Lasers Surg. Med., vol. 38, pp. 714–724, 2006.
    • (2006) Lasers Surg. Med. , vol.38 , pp. 714-724
    • Zhu, C.1    Palmer, G.M.2    Breslin, T.M.3    Harter, J.4    Ramanujam, N.5
  • 29
    • 0003485198 scopus 로고    scopus 로고
    • 2nd ed. London, U.K./Boca Raton, FL: Chapman & Hall/CRC
    • D. Collett, Modelling Binary Data, 2nd ed. London, U.K./Boca Raton, FL: Chapman & Hall/CRC, 2003.
    • (2003) Modelling Binary Data
    • Collett, D.1
  • 30
    • 0032498562 scopus 로고    scopus 로고
    • Physiological and pathological factors of human breast disease that can influence optical diagnosis
    • S. Thomsen and D. Tatman “Physiological and pathological factors of human breast disease that can influence optical diagnosis,” Ann. N. Y. Acad. Sci., vol. 838, pp. 171–193, 1998.
    • (1998) Ann. N. Y. Acad. Sci. , vol.838 , pp. 171-193
    • Thomsen, S.1    Tatman, D.2
  • 31


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.