메뉴 건너뛰기




Volumn 7, Issue 4, 2009, Pages 308-321

A comparative analysis of angular cephalometric values between CBCT generated lateral cephalograms versus digitized conventional lateral cephalograms;Analyse comparative des valeurs céphalométriques de céphalogrammes latéraux générés par CBCT versus céphalogrammes latéraux conventionnels

Author keywords

Cephalometry; Cone Beam Computed Tomography; Orthodontics; Reliability

Indexed keywords


EID: 73449146010     PISSN: 17617227     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1761-7227(09)73505-3     Document Type: Article
Times cited : (10)

References (37)
  • 1
    • 0038227809 scopus 로고
    • Cephalometric roentgenology; History, technics and uses
    • Brodie AG. Cephalometric roentgenology; history, technics and uses. J Oral Surg (Chic) 1949;7:185-198.
    • (1949) J Oral Surg (Chic) , vol.7 , pp. 185-198
    • Brodie, A.G.1
  • 2
    • 0024153053 scopus 로고
    • The effect of projection errors on angular measurements in cephalometry
    • Ahlqvist J, Eliasson S, Welander U. The effect of projection errors on angular measurements in cephalometry. Eur J Orthod 1988;10:353-361.
    • (1988) Eur J Orthod , vol.10 , pp. 353-361
    • Ahlqvist, J.1    Eliasson, S.2    Welander, U.3
  • 3
    • 0022759220 scopus 로고
    • The effect of projection errors on cephalometric length measurements
    • Ahlqvist J, Eliasson S, Welander U. The effect of projection errors on cephalometric length measurements. Eur J Orthod 1986;8:141-148.
    • (1986) Eur J Orthod , vol.8 , pp. 141-148
    • Ahlqvist, J.1    Eliasson, S.2    Welander, U.3
  • 4
    • 0020989776 scopus 로고
    • The cephalometric projection. Part II. Principles of image distortion in cephalography
    • Ahlqvist J, Eliasson S, Welander U. The cephalometric projection. Part II. Principles of image distortion in cephalography. Dentomaxillofac Radiol 1983;12:101-108.
    • (1983) Dentomaxillofac Radiol , vol.12 , pp. 101-108
    • Ahlqvist, J.1    Eliasson, S.2    Welander, U.3
  • 5
    • 0015156256 scopus 로고
    • The reliability of head film measurements. 2. Conventional angular and linear measures
    • Baumrind S, Frantz RC. The reliability of head film measurements. 2. Conventional angular and linear measures. Am J Orthod 1971;60:505-517.
    • (1971) Am J Orthod , vol.60 , pp. 505-517
    • Baumrind, S.1    Frantz, R.C.2
  • 6
    • 0032175841 scopus 로고    scopus 로고
    • The reproducibility of cephalometric landmarks : AAn experimental study on skulls
    • Hägg U, Cooke MS, Chan TC, Tng TT, Lau PY. The reproducibility of cephalometric landmarks : an experimental study on skulls. Aust Orthod J 1998;15:177-185.
    • (1998) Aust Orthod J , vol.15 , pp. 177-185
    • Hägg, U.1    Cooke, M.S.2    Chan, T.C.3    Tng, T.T.4    Lau, P.Y.5
  • 7
    • 22144437389 scopus 로고    scopus 로고
    • The effect of head rotation on cephalometric radiographs
    • Malkoc S, Sari Z, Usumez S, Koyuturk AE. The effect of head rotation on cephalometric radiographs. Eur J Orthod 2005;27:315-321.
    • (2005) Eur J Orthod , vol.27 , pp. 315-321
    • Malkoc, S.1    Sari, Z.2    Usumez, S.3    Koyuturk, A.E.4
  • 8
    • 0029685780 scopus 로고    scopus 로고
    • Effect of head orientation on posterior anterior cephalometric landmark identification
    • Major PW, Johnson DE, Hesse KL, Glover KE. Effect of head orientation on posterior anterior cephalometric landmark identification. Angle Orthod 1996;66:51-60.
    • (1996) Angle Orthod , vol.66 , pp. 51-60
    • Major, P.W.1    Johnson, D.E.2    Hesse, K.L.3    Glover, K.E.4
  • 9
    • 0242607261 scopus 로고    scopus 로고
    • Effect of landmark identification on cephalometric measurements : GGuidelines for cephalometric analyses
    • Perillo M, Beideman R, Shofer F, et al. Effect of landmark identification on cephalometric measurements : guidelines for cephalometric analyses. Clin Orthod Res 2000;3:29-36.
    • (2000) Clin Orthod Res , vol.3 , pp. 29-36
    • Perillo, M.1    Beideman, R.2    Shofer, F.3
  • 10
    • 0032091816 scopus 로고    scopus 로고
    • Reproducibility of cephalometric landmarks on conventional film, hardcopy, and monitor-displayed images obtained by the storage phosphor technique
    • Geelen W, Wenzel A, Gotfredsen E, Kruger M, Hansson LG. Reproducibility of cephalometric landmarks on conventional film, hardcopy, and monitor-displayed images obtained by the storage phosphor technique. Eur J Orthod 1998;20:331-340.
    • (1998) Eur J Orthod , vol.20 , pp. 331-340
    • Geelen, W.1    Wenzel, A.2    Gotfredsen, E.3    Kruger, M.4    Hansson, L.G.5
  • 11
    • 0031204943 scopus 로고    scopus 로고
    • Cephalometric landmarks identification and reproducibility : AA meta analysis
    • Trpkova B, Major P, Prasad N, Nebbe B. Cephalometric landmarks identification and reproducibility : a meta analysis. Am J Orthod Dentofacial Orthop 1997;112:165-170.
    • (1997) Am J Orthod Dentofacial Orthop , vol.112 , pp. 165-170
    • Trpkova, B.1    Major, P.2    Prasad, N.3    Nebbe, B.4
  • 12
    • 0032240404 scopus 로고    scopus 로고
    • A new volumetric CT machine for dental imaging based on the cone-beam technique : PPreliminary results
    • Mozzo P, Procacci C, Tacconi A, Martini PT, Andreis IA. A new volumetric CT machine for dental imaging based on the cone-beam technique : preliminary results. Eur Radiol 1998;8:1558-1564.
    • (1998) Eur Radiol , vol.8 , pp. 1558-1564
    • Mozzo, P.1    Procacci, C.2    Tacconi, A.3    Martini, P.T.4    Andreis, I.A.5
  • 13
    • 44649153747 scopus 로고    scopus 로고
    • Current concepts in maxillofacial imaging
    • Boeddinghaus R, Whyte A. Current concepts in maxillofacial imaging. Eur J Radiol 2008;66:396-418.
    • (2008) Eur J Radiol , vol.66 , pp. 396-418
    • Boeddinghaus, R.1    Whyte, A.2
  • 14
    • 34247619524 scopus 로고    scopus 로고
    • Cone beam computed tomography
    • Small BW. Cone beam computed tomography. Gen Dent 2007;55:179-181.
    • (2007) Gen Dent , vol.55 , pp. 179-181
    • Small, B.W.1
  • 15
    • 33644639722 scopus 로고    scopus 로고
    • Clinical applications of cone-beam computed tomography in dental practice
    • Scarfe WC, Farman AG, Sukovic P. Clinical applications of cone-beam computed tomography in dental practice. J Can Dent Assoc 2006;72:75-80.
    • (2006) J Can Dent Assoc , vol.72 , pp. 75-80
    • Scarfe, W.C.1    Farman, A.G.2    Sukovic, P.3
  • 16
    • 33645731806 scopus 로고    scopus 로고
    • Cone-beam computed tomography in orthodontics : BBenefits and limitations
    • Holberg C, Steinhäuser S, Geis P, Rudzki-Janson I. Cone-beam computed tomography in orthodontics : benefits and limitations. J Orofac Orthop 2005;66:434-444.
    • (2005) J Orofac Orthop , vol.66 , pp. 434-444
    • Holberg, C.1    Steinhäuser, S.2    Geis, P.3    Rudzki-Janson, I.4
  • 18
    • 38949173479 scopus 로고    scopus 로고
    • Accuracy of linear measurements using dental cone beam and conventional multislice computed tomography
    • Suomalainen A, Vehmas T, Kortesniemi M, Robinson S, Peltola J. Accuracy of linear measurements using dental cone beam and conventional multislice computed tomography. Dentomaxillofac Radiol 2008;37:10-17.
    • (2008) Dentomaxillofac Radiol , vol.37 , pp. 10-17
    • Suomalainen, A.1    Vehmas, T.2    Kortesniemi, M.3    Robinson, S.4    Peltola, J.5
  • 19
    • 34547666996 scopus 로고    scopus 로고
    • Comparison of conventional and cone beam CT synthesized cephalograms
    • Kumar V, Ludlow JB, Mol A, Cevidanes L. Comparison of conventional and cone beam CT synthesized cephalograms. Dentomaxillofac Radiol 2007;36:263-269.
    • (2007) Dentomaxillofac Radiol , vol.36 , pp. 263-269
    • Kumar, V.1    Ludlow, J.B.2    Mol, A.3    Cevidanes, L.4
  • 22
    • 29144465753 scopus 로고    scopus 로고
    • Accuracy of linear temporomandibular joint measurements with cone beam computed tomography and digital cephalometric radiography
    • Hilgers ML, Scarfe WC, Scheetz JP, Farman AG. Accuracy of linear temporomandibular joint measurements with cone beam computed tomography and digital cephalometric radiography. Am J Orthod Dentofacial Orthop 2005;128:803-811.
    • (2005) Am J Orthod Dentofacial Orthop , vol.128 , pp. 803-811
    • Hilgers, M.L.1    Scarfe, W.C.2    Scheetz, J.P.3    Farman, A.G.4
  • 23
    • 34848918149 scopus 로고    scopus 로고
    • Accuracy of linear measurements from imaging plate and lateral cephalometric images derived from cone-beam computed tomography
    • Moshiri M, Scarfe WC, Hilgers ML, Scheetz JP, Silveira AM, Farman AG. Accuracy of linear measurements from imaging plate and lateral cephalometric images derived from cone-beam computed tomography. Am J Orthod Dentofacial Orthop 2007;132:550-560.
    • (2007) Am J Orthod Dentofacial Orthop , vol.132 , pp. 550-560
    • Moshiri, M.1    Scarfe, W.C.2    Hilgers, M.L.3    Scheetz, J.P.4    Silveira, A.M.5    Farman, A.G.6
  • 24
    • 50949089055 scopus 로고    scopus 로고
    • In vivo comparison of conventional and cone beam CT synthesized cephalograms
    • Kumar V, Ludlow J, Soares Cevidanes LH, Mol A. In vivo comparison of conventional and cone beam CT synthesized cephalograms. Angle Orthod 2008;78:873-879.
    • (2008) Angle Orthod , vol.78 , pp. 873-879
    • Kumar, V.1    Ludlow, J.2    Soares Cevidanes, L.H.3    Mol, A.4
  • 26
    • 0030972483 scopus 로고    scopus 로고
    • Comparison of the reliability of craniofacial anatomic landmarks based on cephalometric radiographs and three-dimensional CT scans
    • Kragskov J, Bosch C, Gyldensted C, Sindet-Pedersen S. Comparison of the reliability of craniofacial anatomic landmarks based on cephalometric radiographs and three-dimensional CT scans. Cleft Palate Craniofac J 1997;34:111-116.
    • (1997) Cleft Palate Craniofac J , vol.34 , pp. 111-116
    • Kragskov, J.1    Bosch, C.2    Gyldensted, C.3    Sindet-Pedersen, S.4
  • 27
    • 39049178227 scopus 로고    scopus 로고
    • Current clinical research in orthodontics : AA perspective
    • Baumrind S. Current clinical research in orthodontics : a perspective. J Calif Dent Assoc 2006; 34:831-834.
    • (2006) J Calif Dent Assoc , vol.34 , pp. 831-834
    • Baumrind, S.1
  • 28
    • 33644877729 scopus 로고    scopus 로고
    • Three-dimensional cone beam computerized tomography in orthodontics
    • Kau CH, Richmond S, Palomo JM, Hans MG. Three-dimensional cone beam computerized tomography in orthodontics. J Orthod 2005;32:282-293.
    • (2005) J Orthod , vol.32 , pp. 282-293
    • Kau, C.H.1    Richmond, S.2    Palomo, J.M.3    Hans, M.G.4
  • 29
    • 34547914495 scopus 로고    scopus 로고
    • Accuracy of measurements and reliability of landmark identification with computed tomography (CT) techniques in the maxillofacial area : AA systematic review
    • Lou L, Lagravère MO, Compton S, Major PW, Flores-Mir C. Accuracy of measurements and reliability of landmark identification with computed tomography (CT) techniques in the maxillofacial area : a systematic review. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2007;104:402-411.
    • (2007) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.104 , pp. 402-411
    • Lou, L.1    Lagravère, M.O.2    Compton, S.3    Major, P.W.4    Flores-Mir, C.5
  • 30
    • 1542783237 scopus 로고    scopus 로고
    • Cone beam CT for pre-surgical assessment of implant sites
    • Hatcher DC, Dial C, Mayorga C. Cone beam CT for pre-surgical assessment of implant sites. J Calif Dent Assoc 2003;31:825-833.
    • (2003) J Calif Dent Assoc , vol.31 , pp. 825-833
    • Hatcher, D.C.1    Dial, C.2    Mayorga, C.3
  • 31
    • 7944229474 scopus 로고    scopus 로고
    • Craniofacial measurements based on 3D-CT volume rendering : IImplications for clinical applications
    • Cavalcanti MG, Rocha SS, Vannier MW. Craniofacial measurements based on 3D-CT volume rendering : implications for clinical applications. Dentomaxillofac Radiol 2004; 33:170-176.
    • (2004) Dentomaxillofac Radiol , vol.33 , pp. 170-176
    • Cavalcanti, M.G.1    Rocha, S.S.2    Vannier, M.W.3
  • 32
    • 27744445970 scopus 로고    scopus 로고
    • Proposed reference point for 3-dimensional cephalometric analysis with cone-beam computerized tomography
    • Lagravère MO, Major PW. Proposed reference point for 3-dimensional cephalometric analysis with cone-beam computerized tomography. Am J Orthod Dentofacial Orthop 2005;128:657-660.
    • (2005) Am J Orthod Dentofacial Orthop , vol.128 , pp. 657-660
    • Lagravère, M.O.1    Major, P.W.2
  • 33
    • 0026109879 scopus 로고
    • Cephalometric errors : AA comparison between repeat measurements and retaken radiographs
    • Cooke MS, Wei SH. Cephalometric errors : a comparison between repeat measurements and retaken radiographs. Aust Dent J 1991;36:38-43.
    • (1991) Aust Dent J , vol.36 , pp. 38-43
    • Cooke, M.S.1    Wei, S.H.2
  • 35
    • 33645763487 scopus 로고    scopus 로고
    • Low-complexity maximum intensity projection
    • Mora B, Ebert DS. Low-complexity maximum intensity projection. ACM Trans Graph 2005;24:1392-1416.
    • (2005) ACM Trans Graph , vol.24 , pp. 1392-1416
    • Mora, B.1    Ebert, D.S.2
  • 36
    • 0030028916 scopus 로고    scopus 로고
    • Comparison of projection algorithms used for the construction of maximum intensity projection images
    • DOI 10.1097/00004728-199601000-00012
    • Schreiner S, Paschal CB, Galloway RL. Comparison of projection algorithms used for the construction of maximum intensity projection images. J Comput Assist Tomogr 1996;20:56-67. (Pubitemid 26044030)
    • (1996) Journal of Computer Assisted Tomography , vol.20 , Issue.1 , pp. 56-67
    • Schreiner, S.1    Paschal, C.B.2    Galloway, R.L.3
  • 37
    • 33748467800 scopus 로고    scopus 로고
    • A comparison of scanned lateral cephalograms with corresponding original radiographs
    • Bruntz LQ, Palomo JM, Baden S, Hans MG. A comparison of scanned lateral cephalograms with corresponding original radiographs. Am J Orthod Dentofacial Orthop 2006;130:340-348.
    • (2006) Am J Orthod Dentofacial Orthop , vol.130 , pp. 340-348
    • Bruntz, L.Q.1    Palomo, J.M.2    Baden, S.3    Hans, M.G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.