메뉴 건너뛰기




Volumn 62, Issue 6, 2009, Pages 1523-1532

3D noncontrast MR angiography of the distal lower extremities using flow-sensitive dephasing (FSD)-prepared balanced SSFP

Author keywords

Balanced steady state free precession; MRI; Noncontrast MRA; PAD; Peripheral arterial disease

Indexed keywords

ELECTROCARDIOGRAPHY; MAGNETIC RESONANCE IMAGING;

EID: 73149123367     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.22142     Document Type: Article
Times cited : (103)

References (35)
  • 1
    • 2642554707 scopus 로고    scopus 로고
    • Pasternak RC, Criqui MH, Benjamin EJ, Fowkes FG, Isselbacher EM, McCullough PA, Wolf PA, Zheng ZJ. Atherosclerotic Vascular Disease Conference: Writing Group I: epidemiology. Circulation 2004;109: 2605-2612.
    • Pasternak RC, Criqui MH, Benjamin EJ, Fowkes FG, Isselbacher EM, McCullough PA, Wolf PA, Zheng ZJ. Atherosclerotic Vascular Disease Conference: Writing Group I: epidemiology. Circulation 2004;109: 2605-2612.
  • 2
    • 0027192367 scopus 로고
    • MR angiography versus conventional X-ray angiography in the lower extremities: Everyone wins
    • Borrello JA. MR angiography versus conventional X-ray angiography in the lower extremities: everyone wins. Radiology 1993;187:615-617.
    • (1993) Radiology , vol.187 , pp. 615-617
    • Borrello, J.A.1
  • 3
    • 0034127427 scopus 로고    scopus 로고
    • Pelvic and lower extremity arterial imaging: Diagnostic performance of three-dimensional contrast-enhanced MR angiography
    • Ruehm SG, Hany TF, Pfammatter T, Schneider E, Ladd M, Debatin JF. Pelvic and lower extremity arterial imaging: diagnostic performance of three-dimensional contrast-enhanced MR angiography. Am J Roentgenol 2000;174:1127-1135.
    • (2000) Am J Roentgenol , vol.174 , pp. 1127-1135
    • Ruehm, S.G.1    Hany, T.F.2    Pfammatter, T.3    Schneider, E.4    Ladd, M.5    Debatin, J.F.6
  • 4
    • 0036783785 scopus 로고    scopus 로고
    • Peripheral vascular occlusive disease: Evaluation with contrast-enhanced moving-bed MR angiography versus digital subtraction angiography in 106 patients
    • Loewe C, Schoder M, Rand T, Hoffmann U, Sailer J, Kos T, Lammer J, Thurnher S. Peripheral vascular occlusive disease: evaluation with contrast-enhanced moving-bed MR angiography versus digital subtraction angiography in 106 patients. Am J Roentgenol 2002;179:1013-1021.
    • (2002) Am J Roentgenol , vol.179 , pp. 1013-1021
    • Loewe, C.1    Schoder, M.2    Rand, T.3    Hoffmann, U.4    Sailer, J.5    Kos, T.6    Lammer, J.7    Thurnher, S.8
  • 5
    • 33746396046 scopus 로고    scopus 로고
    • Routine use of three-dimensional contrast-enhanced moving-table MR angiography in patients with peripheral arterial occlusive disease: Comparison with selective digital subtraction angiography
    • Deutschmann HA, Schoellnast H, Portugaller HR, Preidler KW, Reittner P, Tillich M, Pilger E, Szolar DH. Routine use of three-dimensional contrast-enhanced moving-table MR angiography in patients with peripheral arterial occlusive disease: comparison with selective digital subtraction angiography. Cardiovasc Intervent Radiol 2006;29:762-770.
    • (2006) Cardiovasc Intervent Radiol , vol.29 , pp. 762-770
    • Deutschmann, H.A.1    Schoellnast, H.2    Portugaller, H.R.3    Preidler, K.W.4    Reittner, P.5    Tillich, M.6    Pilger, E.7    Szolar, D.H.8
  • 6
    • 44849140711 scopus 로고    scopus 로고
    • MR angiography of the lower extremities
    • Ersoy H, Rybicki FJ. MR angiography of the lower extremities. AJR Am J Roentgenol 2008;190:1675-1684.
    • (2008) AJR Am J Roentgenol , vol.190 , pp. 1675-1684
    • Ersoy, H.1    Rybicki, F.J.2
  • 8
    • 20544471646 scopus 로고    scopus 로고
    • Impact of renal insufficiency on mortality in advanced lower extremity peripheral arterial disease
    • O'Hare AM, Bertenthal D, Shlipak MG, Sen S, Chren MM. Impact of renal insufficiency on mortality in advanced lower extremity peripheral arterial disease. J Am Soc Nephrol 2005;16:514-519.
    • (2005) J Am Soc Nephrol , vol.16 , pp. 514-519
    • O'Hare, A.M.1    Bertenthal, D.2    Shlipak, M.G.3    Sen, S.4    Chren, M.M.5
  • 9
    • 33645289942 scopus 로고    scopus 로고
    • Gadolinium: A specific trigger for the development of nephrogenic fibrosing dermopathy and nephrogenic systemic fibrosis?
    • Grobner T. Gadolinium: a specific trigger for the development of nephrogenic fibrosing dermopathy and nephrogenic systemic fibrosis? Nephrol Dial Transplant 2006;21:1104-1108.
    • (2006) Nephrol Dial Transplant , vol.21 , pp. 1104-1108
    • Grobner, T.1
  • 10
    • 33748049106 scopus 로고    scopus 로고
    • Nephrogenic systemic fibrosis: Suspected causative role of gadodiamide used for contrast-enhanced magnetic resonance imaging
    • Marckmann P, Skov L, Rossen K, Dupont A, Damholt MB, Heaf JG, Thomsen HS. Nephrogenic systemic fibrosis: suspected causative role of gadodiamide used for contrast-enhanced magnetic resonance imaging. J Am Soc Nephrol 2006;17:2359-2362.
    • (2006) J Am Soc Nephrol , vol.17 , pp. 2359-2362
    • Marckmann, P.1    Skov, L.2    Rossen, K.3    Dupont, A.4    Damholt, M.B.5    Heaf, J.G.6    Thomsen, H.S.7
  • 11
    • 47249139148 scopus 로고    scopus 로고
    • Nonenhanced MR angiography
    • Miyazaki M, Lee VS. Nonenhanced MR angiography. Radiology 2008; 248:20-43.
    • (2008) Radiology , vol.248 , pp. 20-43
    • Miyazaki, M.1    Lee, V.S.2
  • 15
    • 38949187889 scopus 로고    scopus 로고
    • 3D non-contrast-enhanced MR angiography with balanced steady-state free precession Dixon method
    • Stafford RB, Sabati M, Mahallati H, Frayne R. 3D non-contrast-enhanced MR angiography with balanced steady-state free precession Dixon method. Magn Reson Med 2008;59:430-433.
    • (2008) Magn Reson Med , vol.59 , pp. 430-433
    • Stafford, R.B.1    Sabati, M.2    Mahallati, H.3    Frayne, R.4
  • 16
    • 0242439328 scopus 로고    scopus 로고
    • Principles and applications of balanced SSFP techniques
    • Scheffler K, Lehnhardt S. Principles and applications of balanced SSFP techniques. Eur Radiol 2003;13:2409-2418.
    • (2003) Eur Radiol , vol.13 , pp. 2409-2418
    • Scheffler, K.1    Lehnhardt, S.2
  • 17
    • 0031413020 scopus 로고    scopus 로고
    • Flow-independent angiography for peripheral vascular disease: Initial in-vivo results
    • Gronas R, Kalman PG, Kucey DS, Wright GA. Flow-independent angiography for peripheral vascular disease: initial in-vivo results. J Magn Reson Imaging 1997;7:637-643.
    • (1997) J Magn Reson Imaging , vol.7 , pp. 637-643
    • Gronas, R.1    Kalman, P.G.2    Kucey, D.S.3    Wright, G.A.4
  • 19
    • 0033755110 scopus 로고    scopus 로고
    • Non-contrast-enhanced MR angiography using 3D ECG-synchronized half-Fourier fast spin echo
    • Miyazaki M, Sugiura S, Tateishi F, Wada H, Kassai Y, Abe H. Non-contrast-enhanced MR angiography using 3D ECG-synchronized half-Fourier fast spin echo. J Magn Reson Imaging 2000;12:776-783.
    • (2000) J Magn Reson Imaging , vol.12 , pp. 776-783
    • Miyazaki, M.1    Sugiura, S.2    Tateishi, F.3    Wada, H.4    Kassai, Y.5    Abe, H.6
  • 20
    • 0037950207 scopus 로고    scopus 로고
    • Peripheral MR angiography: Separation of arteries from veins with flow-spoiled gradient pulses in electrocardiography-triggered three-dimensional half-Fourier fast spin-echo imaging
    • Miyazaki M, Takai H, Sugiura S, Wada H, Kuwahara R, Urata J. Peripheral MR angiography: separation of arteries from veins with flow-spoiled gradient pulses in electrocardiography-triggered three-dimensional half-Fourier fast spin-echo imaging. Radiology 2003;227:890-896.
    • (2003) Radiology , vol.227 , pp. 890-896
    • Miyazaki, M.1    Takai, H.2    Sugiura, S.3    Wada, H.4    Kuwahara, R.5    Urata, J.6
  • 23
    • 33845904636 scopus 로고    scopus 로고
    • Diffusion-prepared segmented steady-state free precession: Application to 3D black-blood cardiovascular magnetic resonance of the thoracic aorta and carotid artery walls
    • Koktzoglou I, Li D. Diffusion-prepared segmented steady-state free precession: application to 3D black-blood cardiovascular magnetic resonance of the thoracic aorta and carotid artery walls. J Cardiovasc Magn Reson 2007;9:33-42.
    • (2007) J Cardiovasc Magn Reson , vol.9 , pp. 33-42
    • Koktzoglou, I.1    Li, D.2
  • 24
    • 0242385495 scopus 로고    scopus 로고
    • Flow effects in balanced steady state free precession imaging
    • Markl M, Alley MT, Elkins CJ, Pelc NJ. Flow effects in balanced steady state free precession imaging. Magn Reson Med 2003;50:892-903.
    • (2003) Magn Reson Med , vol.50 , pp. 892-903
    • Markl, M.1    Alley, M.T.2    Elkins, C.J.3    Pelc, N.J.4
  • 25
    • 38749108583 scopus 로고    scopus 로고
    • Magnetic resonance imaging physical principles and sequence design
    • Liss;
    • Haacke EM, Brown RW, Thompson MR, Venkatesan R. Magnetic resonance imaging physical principles and sequence design. New York: Wiley-Liss; 1999;23:673-675.
    • (1999) New York: Wiley , vol.23 , pp. 673-675
    • Haacke, E.M.1    Brown, R.W.2    Thompson, M.R.3    Venkatesan, R.4
  • 26
    • 0014697662 scopus 로고
    • Driven equilibrium Fourier transform spectroscopy: A new method for nuclear magnetic resonance signal enhancement
    • Becker ED, Farrar TC. Driven equilibrium Fourier transform spectroscopy: a new method for nuclear magnetic resonance signal enhancement. J Am Chem Soc 1969;91:7784-7785.
    • (1969) J Am Chem Soc , vol.91 , pp. 7784-7785
    • Becker, E.D.1    Farrar, T.C.2
  • 28
    • 0026885407 scopus 로고
    • Mechanisms of flow-induced signal loss in MR angiography
    • Urchuk SN, Plewes DB. Mechanisms of flow-induced signal loss in MR angiography. J Magn Reson Imaging 1992;2:453-462.
    • (1992) J Magn Reson Imaging , vol.2 , pp. 453-462
    • Urchuk, S.N.1    Plewes, D.B.2
  • 29
    • 66149151771 scopus 로고    scopus 로고
    • Renal transplant: Nonenhanced renal MR angiography with magnetization-prepared steady-state free precession
    • Liu X, Berg N, Sheehan J, Bi X, Weale P, Jerecic R, Carr J. Renal transplant: nonenhanced renal MR angiography with magnetization-prepared steady-state free precession. Radiology 2009;251:535-542.
    • (2009) Radiology , vol.251 , pp. 535-542
    • Liu, X.1    Berg, N.2    Sheehan, J.3    Bi, X.4    Weale, P.5    Jerecic, R.6    Carr, J.7
  • 30
    • 60349108621 scopus 로고    scopus 로고
    • STAR and STARFIRE for flow-dependent and flow-independent noncontrast carotid angiography
    • Koktzoglou I, Edelman RR. STAR and STARFIRE for flow-dependent and flow-independent noncontrast carotid angiography. Magn Reson Med 2009;61:117-124.
    • (2009) Magn Reson Med , vol.61 , pp. 117-124
    • Koktzoglou, I.1    Edelman, R.R.2
  • 33
    • 0026572869 scopus 로고
    • Effect of pulsatile arterial diameter variations on blood flow estimated by Doppler ultrasound
    • Eriksen M. Effect of pulsatile arterial diameter variations on blood flow estimated by Doppler ultrasound. Med Biol Eng Comput 1992;30:46-50.
    • (1992) Med Biol Eng Comput , vol.30 , pp. 46-50
    • Eriksen, M.1
  • 34
    • 26844509096 scopus 로고    scopus 로고
    • Flow compensation in balanced SSFP sequences
    • Bieri O, Scheffler K. Flow compensation in balanced SSFP sequences. Magn Reson Med 2005;54:901-907.
    • (2005) Magn Reson Med , vol.54 , pp. 901-907
    • Bieri, O.1    Scheffler, K.2
  • 35
    • 34848863377 scopus 로고    scopus 로고
    • Reduction of flow- and eddy-currents-induced image artifacts in coronary magnetic resonance angiography using a linear centric-encoding SSFP sequence
    • Bi X, Park J, Deshpande V, Simonetti O, Laub G, Li D. Reduction of flow- and eddy-currents-induced image artifacts in coronary magnetic resonance angiography using a linear centric-encoding SSFP sequence. Magn Reson Imaging 2007;25:1138-1147.
    • (2007) Magn Reson Imaging , vol.25 , pp. 1138-1147
    • Bi, X.1    Park, J.2    Deshpande, V.3    Simonetti, O.4    Laub, G.5    Li, D.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.