메뉴 건너뛰기




Volumn 25, Issue 8, 2007, Pages 1138-1147

Reduction of flow- and eddy-currents-induced image artifacts in coronary magnetic resonance angiography using a linear centric-encoding SSFP sequence

Author keywords

Coronary arteries; Eddy currents; Flow; High field imaging; Magnetic resonance angiography (MRA); SSFP

Indexed keywords

ANGIOCARDIOGRAPHY; ARTICLE; ARTIFACT; CORONARY ARTERY; IMAGE ANALYSIS; IMAGE QUALITY; MAGNETIC RESONANCE ANGIOGRAPHY; MATHEMATICAL MODEL; OSCILLATION; PHANTOM; PRIORITY JOURNAL; RADIOFREQUENCY; SIMULATION; STATISTICAL ANALYSIS;

EID: 34848863377     PISSN: 0730725X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.mri.2007.01.004     Document Type: Article
Times cited : (16)

References (31)
  • 1
    • 0035009703 scopus 로고    scopus 로고
    • Magnetization preparation during the steady state: fat-saturated 3D TrueFISP
    • Scheffler K., Heid O., and Hennig J. Magnetization preparation during the steady state: fat-saturated 3D TrueFISP. Magn Reson Med 45 (2001) 1075-1080
    • (2001) Magn Reson Med , vol.45 , pp. 1075-1080
    • Scheffler, K.1    Heid, O.2    Hennig, J.3
  • 2
    • 0034839555 scopus 로고    scopus 로고
    • 3D magnetization-prepared True-FISP: a new technique for imaging coronary arteries
    • Deshpande V.S., Shea S.M., Laub G., Simonetti O.P., Finn J.P., and Li D. 3D magnetization-prepared True-FISP: a new technique for imaging coronary arteries. Magn Reson Med 46 (2001) 494-502
    • (2001) Magn Reson Med , vol.46 , pp. 494-502
    • Deshpande, V.S.1    Shea, S.M.2    Laub, G.3    Simonetti, O.P.4    Finn, J.P.5    Li, D.6
  • 3
    • 4243093163 scopus 로고    scopus 로고
    • Eddy current optimized phase encoding schemes to reduce artifacts in balanced SSFP imaging
    • Scheffler K., and Hennig K. Eddy current optimized phase encoding schemes to reduce artifacts in balanced SSFP imaging. Proc Intl Soc Mag Reson (2003) 294
    • (2003) Proc Intl Soc Mag Reson , pp. 294
    • Scheffler, K.1    Hennig, K.2
  • 4
    • 26844508308 scopus 로고    scopus 로고
    • Double average parallel steady-state free precession imaging: optimized eddy current and transient oscillation compensation
    • Markl M., Leupold J., Bieri O., Scheffler K., and Hennig J. Double average parallel steady-state free precession imaging: optimized eddy current and transient oscillation compensation. Magn Reson Med 54 (2005) 965-974
    • (2005) Magn Reson Med , vol.54 , pp. 965-974
    • Markl, M.1    Leupold, J.2    Bieri, O.3    Scheffler, K.4    Hennig, J.5
  • 5
    • 21244491945 scopus 로고    scopus 로고
    • Analysis and compensation of eddy currents in balanced SSFP
    • Bieri O., Markl M., and Scheffler K. Analysis and compensation of eddy currents in balanced SSFP. Magn Reson Med 54 (2005) 129-137
    • (2005) Magn Reson Med , vol.54 , pp. 129-137
    • Bieri, O.1    Markl, M.2    Scheffler, K.3
  • 6
    • 0025977678 scopus 로고
    • Analysis of eddy currents in nuclear magnetic resonance imaging
    • Ahn C.B., and Cho Z.H. Analysis of eddy currents in nuclear magnetic resonance imaging. Magn Reson Med 17 (1991) 149-163
    • (1991) Magn Reson Med , vol.17 , pp. 149-163
    • Ahn, C.B.1    Cho, Z.H.2
  • 7
    • 0030726221 scopus 로고    scopus 로고
    • Elimination of eddy current artifacts in diffusion-weighted echo-planar images: the use of bipolar gradients
    • Alexander A.L., Tsuruda J.S., and Parker D.L. Elimination of eddy current artifacts in diffusion-weighted echo-planar images: the use of bipolar gradients. Magn Reson Med 38 (1997) 1016-1021
    • (1997) Magn Reson Med , vol.38 , pp. 1016-1021
    • Alexander, A.L.1    Tsuruda, J.S.2    Parker, D.L.3
  • 8
    • 4243150701 scopus 로고    scopus 로고
    • View ordering for magnetization prepared steady state free precession acquisition: application in contrast-enhanced MR angiography
    • Spincemaille P., Nguyen T.D., and Wang Y. View ordering for magnetization prepared steady state free precession acquisition: application in contrast-enhanced MR angiography. Magn Reson Med 52 (2004) 461-466
    • (2004) Magn Reson Med , vol.52 , pp. 461-466
    • Spincemaille, P.1    Nguyen, T.D.2    Wang, Y.3
  • 9
    • 0036845522 scopus 로고    scopus 로고
    • Single-breathhold 3D-TrueFISP cine cardiac imaging
    • Jung B.A., Hennig J., and Scheffler K. Single-breathhold 3D-TrueFISP cine cardiac imaging. Magn Reson Med 48 (2002) 921-925
    • (2002) Magn Reson Med , vol.48 , pp. 921-925
    • Jung, B.A.1    Hennig, J.2    Scheffler, K.3
  • 10
    • 19544364672 scopus 로고    scopus 로고
    • Optimizing spatiotemporal sampling for k-t BLAST and k-t SENSE: application to high-resolution real-time cardiac steady-state free precession
    • Tsao J., Kozerke S., Boesiger P., and Pruessmann K.P. Optimizing spatiotemporal sampling for k-t BLAST and k-t SENSE: application to high-resolution real-time cardiac steady-state free precession. Magn Reson Med 53 (2005) 1372-1382
    • (2005) Magn Reson Med , vol.53 , pp. 1372-1382
    • Tsao, J.1    Kozerke, S.2    Boesiger, P.3    Pruessmann, K.P.4
  • 12
    • 0347003637 scopus 로고    scopus 로고
    • Flow artifacts in steady-state free precession cine imaging
    • Storey P., Li W., Chen Q., and Edelman R.R. Flow artifacts in steady-state free precession cine imaging. Magn Reson Med 51 (2004) 115-122
    • (2004) Magn Reson Med , vol.51 , pp. 115-122
    • Storey, P.1    Li, W.2    Chen, Q.3    Edelman, R.R.4
  • 13
    • 0242385495 scopus 로고    scopus 로고
    • Flow effects in balanced steady state free precession imaging
    • Markl M., Alley M.T., Elkins C.J., and Pelc N.J. Flow effects in balanced steady state free precession imaging. Magn Reson Med 50 (2003) 892-903
    • (2003) Magn Reson Med , vol.50 , pp. 892-903
    • Markl, M.1    Alley, M.T.2    Elkins, C.J.3    Pelc, N.J.4
  • 14
    • 26844509096 scopus 로고    scopus 로고
    • Flow compensation in balanced SSFP sequences
    • Bieri O., and Scheffler K. Flow compensation in balanced SSFP sequences. Magn Reson Med 54 (2005) 901-907
    • (2005) Magn Reson Med , vol.54 , pp. 901-907
    • Bieri, O.1    Scheffler, K.2
  • 15
    • 1642458186 scopus 로고    scopus 로고
    • Dark flow artifacts with steady-state free precession cine MR technique: causes and implications for cardiac MR imaging
    • Li W., Storey P., Chen Q., Li B.S., Prasad P.V., and Edelman R.R. Dark flow artifacts with steady-state free precession cine MR technique: causes and implications for cardiac MR imaging. Radiology 230 (2004) 569-575
    • (2004) Radiology , vol.230 , pp. 569-575
    • Li, W.1    Storey, P.2    Chen, Q.3    Li, B.S.4    Prasad, P.V.5    Edelman, R.R.6
  • 16
    • 2942751880 scopus 로고    scopus 로고
    • Improved magnetization preparation for navigator steady-state free precession 3D coronary MR angiography
    • Nguyen T.D., Spincemaille P., and Wang Y. Improved magnetization preparation for navigator steady-state free precession 3D coronary MR angiography. Magn Reson Med 51 (2004) 1297-1300
    • (2004) Magn Reson Med , vol.51 , pp. 1297-1300
    • Nguyen, T.D.1    Spincemaille, P.2    Wang, Y.3
  • 17
    • 0344305581 scopus 로고    scopus 로고
    • Whole-heart steady-state free precession coronary artery magnetic resonance angiography
    • Weber O.M., Martin A.J., and Higgins C.B. Whole-heart steady-state free precession coronary artery magnetic resonance angiography. Magn Reson Med 50 (2003) 1223-1228
    • (2003) Magn Reson Med , vol.50 , pp. 1223-1228
    • Weber, O.M.1    Martin, A.J.2    Higgins, C.B.3
  • 18
    • 4344637817 scopus 로고    scopus 로고
    • Free-breathing, three-dimensional coronary artery magnetic resonance angiography: comparison of sequences
    • Weber O.M., Pujadas S., Martin A.J., and Higgins C.B. Free-breathing, three-dimensional coronary artery magnetic resonance angiography: comparison of sequences. J Magn Reson Imaging 20 (2004) 395-402
    • (2004) J Magn Reson Imaging , vol.20 , pp. 395-402
    • Weber, O.M.1    Pujadas, S.2    Martin, A.J.3    Higgins, C.B.4
  • 19
    • 24444435246 scopus 로고    scopus 로고
    • Considerations on shimming for cardiac applications at 1.5 and 3.0T
    • Schar M., Kozerke S., and Boesiger P. Considerations on shimming for cardiac applications at 1.5 and 3.0T. Proc Int Soc Magn Reson (2003) 174
    • (2003) Proc Int Soc Magn Reson , pp. 174
    • Schar, M.1    Kozerke, S.2    Boesiger, P.3
  • 20
    • 0242684663 scopus 로고    scopus 로고
    • Artifact reduction in True-FISP imaging of the coronary arteries by adjusting imaging frequency
    • Deshpande V.S., Shea S.M., and Li D. Artifact reduction in True-FISP imaging of the coronary arteries by adjusting imaging frequency. Magn Reson Med 49 (2003) 803-809
    • (2003) Magn Reson Med , vol.49 , pp. 803-809
    • Deshpande, V.S.1    Shea, S.M.2    Li, D.3
  • 21
    • 0001426032 scopus 로고
    • Analytical method for the compensation of eddy-current effects induced by pulsed magnetic field gradient in NMR systems
    • Jehenson P., Westphal M., and Schiff N. Analytical method for the compensation of eddy-current effects induced by pulsed magnetic field gradient in NMR systems. J Magn Reson 90 (1990) 264-278
    • (1990) J Magn Reson , vol.90 , pp. 264-278
    • Jehenson, P.1    Westphal, M.2    Schiff, N.3
  • 22
    • 0025944431 scopus 로고
    • Gradient moment nulling for steady-state free precession MR imaging of cerebrospinal fluid
    • Wood M.L., Zur Y., and Neuringer L.J. Gradient moment nulling for steady-state free precession MR imaging of cerebrospinal fluid. Med Phys 18 (1991) 1038-1044
    • (1991) Med Phys , vol.18 , pp. 1038-1044
    • Wood, M.L.1    Zur, Y.2    Neuringer, L.J.3
  • 23
    • 0037229176 scopus 로고    scopus 로고
    • Reduction of transient signal oscillations in True-FISP using a linear flip angle series magnetization preparation
    • Deshpande V.S., Chung Y.C., Zhang Q., Shea S.M., and Li D. Reduction of transient signal oscillations in True-FISP using a linear flip angle series magnetization preparation. Magn Reson Med 49 (2003) 151-157
    • (2003) Magn Reson Med , vol.49 , pp. 151-157
    • Deshpande, V.S.1    Chung, Y.C.2    Zhang, Q.3    Shea, S.M.4    Li, D.5
  • 26
    • 14944360212 scopus 로고    scopus 로고
    • Coronary magnetic resonance angiography for the detection of coronary stenoses
    • Kim W.Y., Danias P.G., Stuber M., Flamm S.D., Plein S., Nagel E., et al. Coronary magnetic resonance angiography for the detection of coronary stenoses. N Engl J Med 345 (2001) 1863-1869
    • (2001) N Engl J Med , vol.345 , pp. 1863-1869
    • Kim, W.Y.1    Danias, P.G.2    Stuber, M.3    Flamm, S.D.4    Plein, S.5    Nagel, E.6
  • 27
    • 0036708130 scopus 로고    scopus 로고
    • Frequency-modulated steady-state free precession imaging
    • Foxall D.L. Frequency-modulated steady-state free precession imaging. Magn Reson Med 48 (2002) 502-508
    • (2002) Magn Reson Med , vol.48 , pp. 502-508
    • Foxall, D.L.1
  • 30
    • 0032908729 scopus 로고    scopus 로고
    • Automated monitoring of diaphragm end-expiratory position for real-time navigator echo MR coronary angiography
    • Taylor A.M., Jhooti P., Firmin D.N., and Pennell D.J. Automated monitoring of diaphragm end-expiratory position for real-time navigator echo MR coronary angiography. J Magn Reson Imaging 9 (1999) 395-401
    • (1999) J Magn Reson Imaging , vol.9 , pp. 395-401
    • Taylor, A.M.1    Jhooti, P.2    Firmin, D.N.3    Pennell, D.J.4
  • 31
    • 0030026702 scopus 로고    scopus 로고
    • Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography
    • Wang Y., Rossman P.J., Grimm R.C., Riederer S.J., and Ehman R.L. Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography. Radiology 198 (1996) 55-60
    • (1996) Radiology , vol.198 , pp. 55-60
    • Wang, Y.1    Rossman, P.J.2    Grimm, R.C.3    Riederer, S.J.4    Ehman, R.L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.