-
1
-
-
0028414179
-
A micromachined silicon sieve electrode for nerve regeneration applications
-
Akin T, Najafi K, Smoke R H and Bradley R M 1994 A micromachined silicon sieve electrode for nerve regeneration applications IEEE Trans. Biomed. Eng. 41 305-13
-
(1994)
IEEE Trans. Biomed. Eng.
, vol.41
, Issue.4
, pp. 305-313
-
-
Akin, T.1
Najafi, K.2
Smoke, R.H.3
Bradley, R.M.4
-
2
-
-
2442501369
-
The retina implant-a new approach for a visual prosthesis
-
Alteheld N, Roessler G, Vobig M and Walter P 2004 The retina implant-a new approach for a visual prosthesis Biomed. Techn. 49 99-103
-
(2004)
Biomed. Techn.
, vol.49
, Issue.4
, pp. 99-103
-
-
Alteheld, N.1
Roessler, G.2
Vobig, M.3
Walter, P.4
-
3
-
-
0017367642
-
Electrochemical considerations for safe electrical stimulation of the nervous system with platinum electrodes
-
Brummer S B and Turner M J 1977 Electrochemical considerations for safe electrical stimulation of the nervous system with platinum electrodes IEEE Trans. Biomed. Eng. 24 59-63
-
(1977)
IEEE Trans. Biomed. Eng.
, vol.24
, Issue.1
, pp. 59-63
-
-
Brummer, S.B.1
Turner, M.J.2
-
4
-
-
1842582778
-
The artificial silicon retina microchip for the treatment of vision loss from retinitis pigmentosa
-
Chow A Y et al 2004 The artificial silicon retina microchip for the treatment of vision loss from retinitis pigmentosa Arch. Ophthalmol. 122 460-9
-
(2004)
Arch. Ophthalmol.
, vol.122
, Issue.4
, pp. 460-469
-
-
Chow, A.Y.1
-
5
-
-
65949087863
-
-
Cogan S F, Ehrlich J, Plante T D, Smirnov A, Shire D B, Gingerich M and Rizzo J F 2009 J. Biomed. Mater. Res. B 89 353-61
-
(2009)
J. Biomed. Mater. Res.
, vol.89
, Issue.2
, pp. 353-361
-
-
Cogan, S.F.1
Ehrlich, J.2
Plante, T.D.3
Smirnov, A.4
Shire, D.B.5
Gingerich, M.6
Rizzo, J.F.7
-
6
-
-
0022743463
-
Performance of platinum stimulating electrodes mapped on the limit-voltge- plane: Part 2. Corrosion in vitro
-
Donaldson N de N and Donaldson P E K 1986 Performance of platinum stimulating electrodes mapped on the limit-voltge- plane: Part 2. Corrosion in vitro Med. Biol. Eng. Comp. 24 431-8
-
(1986)
Med. Biol. Eng. Comp.
, vol.24
, Issue.4
, pp. 431-438
-
-
Donaldson, N.D.N.1
Donaldson, P.E.K.2
-
7
-
-
0030826554
-
Learning retina implants with epiretinal contacts
-
Eckmiller R 1997 Learning retina implants with epiretinal contacts Ophthalmic Res. 29 281-9
-
(1997)
Ophthalmic Res.
, vol.29
, pp. 281-289
-
-
Eckmiller, R.1
-
8
-
-
21744462254
-
Optical imaging reveals 2-dimensional patterns of cortical activation after local retinal stimulation with sub- and epiretinal visual prostheses
-
Eysel U T, Walter P, Gekeler F, Schwahn H, Zrenner E, Sachs H G, Gabel V P and Kisvrday Z F 2003 Optical imaging reveals 2-dimensional patterns of cortical activation after local retinal stimulation with sub- and epiretinal visual prostheses Invest. Ophthalmol. Vis. Sci 43 4486
-
(2003)
Invest. Ophthalmol. Vis. Sci
, vol.43
, pp. 4486
-
-
Eysel, U.T.1
Walter, P.2
Gekeler, F.3
Schwahn, H.4
Zrenner, E.5
Sachs, H.G.6
Gabel, V.P.7
Kisvrday, Z.F.8
-
9
-
-
0000321965
-
Beiträge zur Pathophysiologie der Sehbahn und der Sehsphäre
-
Foerster O 1929 Beiträge zur Pathophysiologie der Sehbahn und der Sehsphäre J. Psychol. Neurol. 39 435-68
-
(1929)
J. Psychol. Neurol.
, vol.39
, pp. 435-468
-
-
Foerster, O.1
-
10
-
-
0024543189
-
Histological reaction to polyimide films in the cochlea
-
Haggerty H S and Lusted H S 1989 Histological reaction to polyimide films in the cochlea Acta Otolaryngol. 107 13-22
-
(1989)
Acta Otolaryngol.
, vol.107
, Issue.1
, pp. 13-22
-
-
Haggerty, H.S.1
Lusted, H.S.2
-
11
-
-
72849127843
-
The Eye and the Chip. World Congress on Artificial Vision 2006 (Editorial)
-
Hessburg P C and Rizzo J F 2007 The Eye and the Chip. World Congress on Artificial Vision 2006 (Editorial) J. Neural Eng. 4 (1) special issue
-
(2007)
J. Neural Eng.
, vol.4
, Issue.1
-
-
Hessburg, P.C.1
Rizzo, J.F.2
-
12
-
-
22044451448
-
A method and technical equipment for an acute human trial to evaluate retinal implant technology
-
Hornig R et al 2005 A method and technical equipment for an acute human trial to evaluate retinal implant technology J. Neural Eng. 2 S139-4
-
(2005)
J. Neural Eng.
, vol.2
-
-
Hornig, R.1
-
13
-
-
0032952549
-
Morphometric analysis of the extramacular retina from postmortem eyes with retinitis pigmentosa
-
Humayun M S et al 1999 Morphometric analysis of the extramacular retina from postmortem eyes with retinitis pigmentosa Invest. Ophthalmol. Vis. Sci. 40 143-8
-
(1999)
Invest. Ophthalmol. Vis. Sci.
, vol.40
, pp. 143-148
-
-
Humayun, M.S.1
-
14
-
-
0038598030
-
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
-
Humayun M S et al 2003 Visual perception in a blind subject with a chronic microelectronic retinal prosthesis Vis. Res. 43 2573-81
-
(2003)
Vis. Res.
, vol.43
, Issue.24
, pp. 2573-2581
-
-
Humayun, M.S.1
-
16
-
-
33745203504
-
Retinal prostheses for the blind
-
Javaheri M, Hahn D S, Rohit B S, Lakhanpal R, Weiland J D and Humayun M S 2006 Retinal prostheses for the blind Ann. Acad. Med. Singapore 35 137-44
-
(2006)
Ann. Acad. Med. Singapore
, vol.35
, pp. 137-144
-
-
Javaheri, M.1
Hahn, D.S.2
Rohit, B.S.3
Lakhanpal, R.4
Weiland, J.D.5
Humayun, M.S.6
-
17
-
-
0036120864
-
Development and surgical implantation of a vision prosthesis model into the ovine eye
-
Kerdraon Y A et al 2002 Development and surgical implantation of a vision prosthesis model into the ovine eye Clin. Exp. Ophthalmol. 30 36-40
-
(2002)
Clin. Exp. Ophthalmol.
, vol.30
, Issue.1
, pp. 36-40
-
-
Kerdraon, Y.A.1
-
18
-
-
70349229397
-
Feasibility of micro electrode array (MEA) based on silicone-polyimide hybrid for retina prosthesis
-
Kim E T, Kim C, Lee S W, Seo J M, Chung H and Kim S J 2009 Feasibility of micro electrode array (MEA) based on silicone-polyimide hybrid for retina prosthesis Invest. Ophthalmol. Vis. Sci. (Epub ahead of print)
-
(2009)
Invest. Ophthalmol. Vis. Sci.
-
-
Kim, E.T.1
Kim, C.2
Lee, S.W.3
Seo, J.M.4
Chung, H.5
Kim, S.J.6
-
19
-
-
0036342953
-
Retinal prosthesis for the blind
-
Margalit E et al 2002 Retinal prosthesis for the blind Surv. Ophthalmol. 47 335-6
-
(2002)
Surv. Ophthalmol.
, vol.47
, Issue.4
, pp. 335-336
-
-
Margalit, E.1
-
20
-
-
12944280406
-
The retina implant-a BIOMEMS challenge
-
Meyer J U 2002 The retina implant-a BIOMEMS challenge Sensors Actuators A 97-98 1-9
-
(2002)
Sensors Actuators
, vol.97-98
, Issue.1-2
, pp. 1-9
-
-
Meyer, J.U.1
-
21
-
-
0035422827
-
High density interconnects and flexible hybrid assemblies for active biomedical implants
-
Meyer J U, Stieglitz T, Scholz O, Haberer W and Beutel H 2001 High density interconnects and flexible hybrid assemblies for active biomedical implants IEEE Trans. Adv. Pack. 24 366-74
-
(2001)
IEEE Trans. Adv. Pack.
, vol.24
, Issue.3
, pp. 366-374
-
-
Meyer, J.U.1
Stieglitz, T.2
Scholz, O.3
Haberer, W.4
Beutel, H.5
-
22
-
-
0030628661
-
Conformal coating using parylene polymers
-
Noordegraaf J 1997 Conformal coating using parylene polymers Med. Device Technol. 8 14-20
-
(1997)
Med. Device Technol.
, vol.8
, pp. 14-20
-
-
Noordegraaf, J.1
-
23
-
-
0027627674
-
Polyimides as biomaterials: Preliminary biocompatibility testing
-
Richardson R R, Miller J A and Reichert W M 1993 Polyimides as biomaterials: preliminary biocompatibility testing J. Biomat. 14 627-35
-
(1993)
J. Biomat.
, vol.14
, Issue.8
, pp. 627-635
-
-
Richardson, R.R.1
Miller, J.A.2
Reichert, W.M.3
-
24
-
-
2542443698
-
Transretinal electrical stimulation with a suprachoroidal multichannel electrode in rabbit eyes
-
DOI 10.1007/s10384-004-0055-1
-
Sakaguchi H et al 2004 Transretinal electrical stimulation with a suprachoroidal multichannel electrode in rabbit eyes Japan. J. Ophthalmol 48 256-61 (Pubitemid 38691434)
-
(2004)
Japanese Journal of Ophthalmology
, vol.48
, Issue.3
, pp. 256-261
-
-
Sakaguchi, H.1
Fujikado, T.2
Fang, X.3
Kanda, H.4
Osanai, M.5
Nakauchi, K.6
Ikuno, Y.7
Kamei, M.8
Yagi, T.9
Nishimura, S.10
Ohji, M.11
Yagi, T.12
Tano, Y.13
-
25
-
-
0030940097
-
Preservation of the inner retina in retinitis pigmentosa. A morphometric analysis
-
Santos A et al 1997 Preservation of the inner retina in retinitis pigmentosa. A morphometric analysis Arch. Ophthalmol. 115 511-5
-
(1997)
Arch. Ophthalmol.
, vol.115
, pp. 511-515
-
-
Santos, A.1
-
26
-
-
34249289377
-
An optically powered single-channel stimulation implant as test system for chronic biocompatibility and biostability for miniaturized retinal vision prostheses
-
Schanze T, Stieglitz T, Hesse L, Lau C, Greve N, Haberer W, Kammer S, Richter H and Rentzos A 2007 An optically powered single-channel stimulation implant as test system for chronic biocompatibility and biostability for miniaturized retinal vision prostheses IEEE Trans. Biomed. Eng. 54 983-92
-
(2007)
IEEE Trans. Biomed. Eng.
, vol.54
, Issue.6
, pp. 983-992
-
-
Schanze, T.1
Stieglitz, T.2
Hesse, L.3
Lau, C.4
Greve, N.5
Haberer, W.6
Kammer, S.7
Richter, H.8
Rentzos, A.9
-
27
-
-
0018163887
-
Histopathological evaluation of materials implanted in the cerebral cortex
-
Stensaas S S and Stensaas L J 1978 Histopathological evaluation of materials implanted in the cerebral cortex Acta Neuropathol. (Berl.) 41 145-55
-
(1978)
Acta Neuropathol. (Berl.)
, vol.41
, Issue.2
, pp. 145-155
-
-
Stensaas, S.S.1
Stensaas, L.J.2
-
28
-
-
0031294053
-
Development of flexible stimulation devices for a retina implant system
-
Stieglitz T, Beutel H, Keller R, Blau C and Meyer JU 1997 Development of flexible stimulation devices for a retina implant system Proc. 19th Ann. Int. Conf. of the IEEE Engineering in Medicine and Biology Society (Chicago, USA, 30 Oct-2 Nov 1997) pp 2307-10
-
(1997)
Proc. 19th Ann. Int. Conf. of the IEEE Engineering in Medicine and Biology Society
, pp. 2307-2310
-
-
Stieglitz, T.1
Beutel, H.2
Keller, R.3
Blau, C.4
Meyer, J.U.5
-
29
-
-
0001574753
-
Micromachined, polyimide-based devices for flexible neural interfaces
-
Stieglitz T, Beutel H, Schuettler M and Meyer J U 2000a Micromachined, polyimide-based devices for flexible neural interfaces Biomed. Microdevices 2 283-94
-
(2000)
Biomed. Microdevices
, vol.2
, Issue.4
, pp. 283-294
-
-
Stieglitz, T.1
Beutel, H.2
Schuettler, M.3
Meyer, J.U.4
-
31
-
-
0006293299
-
Microsystem integration techniques for intraocular vision prostheses using flexible polyimide-foils
-
Stieglitz T, Keller R, Beutel H and Meyer J U 2000b Microsystem integration techniques for intraocular vision prostheses using flexible polyimide-foils Proc. MICRO.tec 2000 (Hannover/Germany, 25-27 September 2000) pp 467-72
-
(2000)
Proc. MICRO.tec 2000
, pp. 467-472
-
-
Stieglitz, T.1
Keller, R.2
Beutel, H.3
Meyer, J.U.4
-
32
-
-
0009676957
-
Hybrid integration of a retina implant system for people suffering from retinitis pigmentosa
-
1102-3
-
Stieglitz T, Keller R, Beutel H, Ruf H H, Robitzki A A and Meyer J U 1999 Hybrid integration of a retina implant system for people suffering from retinitis pigmentosa Med. Biol. Eng. Com. 37 Suppl. 2 1102-3
-
(1999)
Med. Biol. Eng. Com.
, vol.37
, pp. 2
-
-
Stieglitz, T.1
Keller, R.2
Beutel, H.3
Ruf, H.H.4
Robitzki, A.A.5
Meyer, J.U.6
-
33
-
-
33745108264
-
Biomedical microdevices for neural implants
-
Stieglitz T and Meyer J U 2006 Biomedical microdevices for neural implants BIOMEMS ed G A Urban (Dordrecht: Springer) pp 71-138
-
(2006)
BIOMEMS
, vol.16
, pp. 71-138
-
-
Stieglitz, T.1
Meyer, J.U.2
-
34
-
-
72849141674
-
-
Stieglitz T, Wien S, Reininger-Mack A, Schuettler M, Doerge T and Robitzki A 2009 In vitro cytotoxicity of polyimide as biomaterial for micromachined neural prostheses and biohybrid systems (in preparation)
-
(2009)
In Vitro Cytotoxicity of Polyimide As Biomaterial for Micromachined Neural Prostheses and Biohybrid Systems
-
-
Stieglitz, T.1
Wien, S.2
Reininger-Mack, A.3
Schuettler, M.4
Doerge, T.5
Robitzki, A.6
-
35
-
-
0026460822
-
Morphometric analysis of macular photoreceptors and ganglion cells in retinas with retinitis pigmentosa
-
Stone J L, Barlow W E, Humayun M S, de Juan E J and Milam A H 1992 Morphometric analysis of macular photoreceptors and ganglion cells in retinas with retinitis pigmentosa Arch. Ophthalmol. 110 I634-39
-
(1992)
Arch. Ophthalmol.
, vol.110
-
-
Stone, J.L.1
Barlow, W.E.2
Humayun, M.S.3
De Juan, E.J.4
Milam, A.H.5
-
36
-
-
13544250804
-
Vision rehabilitation in the case of blindness
-
Veraart C, Duret F, Brelén M, Oozeer M and Delbeke J 2004 Vision rehabilitation in the case of blindness Expert Rev. Med. Devices 1 139-53
-
(2004)
Expert Rev. Med. Devices
, vol.1
, Issue.1
, pp. 139-153
-
-
Veraart, C.1
Duret, F.2
Brelén, M.3
Oozeer, M.4
Delbeke, J.5
-
37
-
-
20444454583
-
Cortical activation with a completely implanted wireless retinal prosthesis
-
Walter P, Kisvrday Z F, Görtz M, Alteheld N, Rössler G, Stieglitz T and Eysel U T 2005 Cortical activation with a completely implanted wireless retinal prosthesis Invest. Ophthal. Vis. Sci. 46 1780-5
-
(2005)
Invest. Ophthal. Vis. Sci.
, vol.46
, Issue.5
, pp. 1780-1785
-
-
Walter, P.1
Kisvrday, Z.F.2
Görtz, M.3
Alteheld, N.4
Rössler, G.5
Stieglitz, T.6
Eysel, U.T.7
-
38
-
-
0344196628
-
Evoked cortical potentials after electrical surface stimulation of the rabbit's retina
-
Walter P, Szurman P, Peixoto N, Straburger S, Trieu H K, Ewe L, Stieglitz T, Meyer J U and Heimann K 1998 Evoked cortical potentials after electrical surface stimulation of the rabbit's retina Invest. Ophthalmol. Vis. Sci. 39 S990
-
(1998)
Invest. Ophthalmol. Vis. Sci.
, vol.39
, pp. 990
-
-
Walter, P.1
Szurman, P.2
Peixoto, N.3
Straburger, S.4
Trieu, H.K.5
Ewe, L.6
Stieglitz, T.7
Meyer, J.U.8
Heimann, K.9
-
39
-
-
0033506272
-
Successful long-term implantation of electrically inactive epiretinal microelectrode arrays in rabbits
-
Walter P, Szurman P, Vobig M, Berk H, Lüdtke-Handjery H C, Richter H, Mittermayer C, Heimann K and Sellhaus B 1999 Successful long-term implantation of electrically inactive epiretinal microelectrode arrays in rabbits Retina 19 546-52
-
(1999)
Retina
, vol.19
, Issue.6
, pp. 546-552
-
-
Walter, P.1
Szurman, P.2
Vobig, M.3
Berk, H.4
Lüdtke-Handjery, H.C.5
Richter, H.6
Mittermayer, C.7
Heimann, K.8
Sellhaus, B.9
-
40
-
-
42749096667
-
On the mechanisms of biocompatibility
-
Williams D F 2008 On the mechanisms of biocompatibility Biomat 29 2841-953
-
(2008)
Biomat
, vol.29
, Issue.20
, pp. 2941-2953
-
-
Williams, D.F.1
-
41
-
-
1642269212
-
Visual resolution with epi-retinal electrical stimulation estimated from activation profiles in the cat visual cortex
-
Wilms M, Eger M, Schanze T and Eckhorn R 2003 Visual resolution with epi-retinal electrical stimulation estimated from activation profiles in the cat visual cortex Vis. Neurosci 20 543-55
-
(2003)
Vis. Neurosci
, vol.20
, Issue.5
, pp. 543-555
-
-
Wilms, M.1
Eger, M.2
Schanze, T.3
Eckhorn, R.4
-
42
-
-
64049110076
-
Focal activation of the feline retina via a suprachoroidal electrode array
-
Wong Y T, Chen S C, Seo J M, Morley J W, Lovell N H and Suaning G J 2009 Focal activation of the feline retina via a suprachoroidal electrode array Vis. Res. 49 825-33
-
(2009)
Vis. Res.
, vol.49
, Issue.8
, pp. 825-833
-
-
Wong, Y.T.1
Chen, S.C.2
Seo, J.M.3
Morley, J.W.4
Lovell, N.H.5
Suaning, G.J.6
-
43
-
-
22044432277
-
Comparison of electrically evoked cortical potential thresholds generated with subretinal or suprachoroidal placement of a microelectrode array in the rabbit
-
Yamauchi Y, Franco L M, Jackson D J, Naber J F, Ziv R O, Rizzo J F, Kaplan H J and Enzmann V 2005 Comparison of electrically evoked cortical potential thresholds generated with subretinal or suprachoroidal placement of a microelectrode array in the rabbit J. Neural Eng. 2 S48-56
-
(2005)
J. Neural Eng.
, vol.2
, Issue.1
-
-
Yamauchi, Y.1
Franco, L.M.2
Jackson, D.J.3
Naber, J.F.4
Ziv, R.O.5
Rizzo, J.F.6
Kaplan, H.J.7
Enzmann, V.8
-
44
-
-
0032943727
-
Can microphotodiode arrays replace degenerated retinal photoreceptors to restore vision?
-
Zrenner E et al 1999 Can microphotodiode arrays replace degenerated retinal photoreceptors to restore vision? Vision Res. 39 2555-67
-
(1999)
Vision Res.
, vol.39
, Issue.15
, pp. 2555-2567
-
-
Zrenner, E.1
|