-
2
-
-
0035722843
-
Three-dimensional electrical impedance tomography of human brain activity
-
T. Tidswell, A. Gibson, R. H. Bayford, and D. S. Holder, "Three-dimensional electrical impedance tomography of human brain activity," Neuroimage, vol.13, pp. 283-294, 2001.
-
(2001)
Neuroimage
, vol.13
, pp. 283-294
-
-
Tidswell, T.1
Gibson, A.2
Bayford, R.H.3
Holder, D.S.4
-
3
-
-
34447106876
-
Reproducibility of regional lung ventilation distribution determined by electrical impedance tomography during mechanical ventilation
-
I. Frerichs, G. Schmitz, S. Pulletz, D. Schadler, G. Zick, J. Scholz, and N. Weiler, "Reproducibility of regional lung ventilation distribution determined by electrical impedance tomography during mechanical ventilation," Physiol. Meas., vol.28, no.7, pp. S261-S267, 2007.
-
(2007)
Physiol. Meas.
, vol.28
, Issue.7
-
-
Frerichs, I.1
Schmitz, G.2
Pulletz, S.3
Schadler, D.4
Zick, G.5
Scholz, J.6
Weiler, N.7
-
4
-
-
0028276263
-
A comparison of ventilatory and cardiac related changes in EIT images of normal human lungs and of lungs with pulmonary emboli
-
A. D. Leathard, B. H. Brown, J. H. Campbell, F. Z. A. H. Morice, and D. Taylor, "A comparison of ventilatory and cardiac related changes in EIT images of normal human lungs and of lungs with pulmonary emboli," Phyisiol. Meas., vol. 15, no. 2A, pp. A137-A146, 1994.
-
(1994)
Phyisiol. Meas.
, vol.15
, Issue.2 A
-
-
Leathard, A.D.1
Brown, B.H.2
Campbell, J.H.3
Morice, F.Z.A.H.4
Taylor, D.5
-
5
-
-
0036591481
-
Electrical impedance spectroscopy of the breast: Clinical imaging results in 26 subjects
-
Jun.
-
T. E. Kerner, K. D. Paulsen, A. Hartov, S. K. Soho, and S. P. Poplack, "Electrical impedance spectroscopy of the breast: Clinical imaging results in 26 subjects," IEEE Trans.Med. Imag., vol.21, no.6, pp. 638-645, Jun. 2002.
-
(2002)
IEEE Trans.Med. Imag.
, vol.21
, Issue.6
, pp. 638-645
-
-
Kerner, T.E.1
Paulsen, K.D.2
Hartov, A.3
Soho, S.K.4
Poplack, S.P.5
-
6
-
-
1342268914
-
Multifrequency electrical impedance tomography of the breast: New clinical results
-
N. Soni, A. Hartov, C. Kogel, S. P. Poplack, and K. D. Paulsen, "Multifrequency electrical impedance tomography of the breast: New clinical results," Physiol. Meas., vol.25, pp. 301-314, 2004.
-
(2004)
Physiol. Meas.
, vol.25
, pp. 301-314
-
-
Soni, N.1
Hartov, A.2
Kogel, C.3
Poplack, S.P.4
Paulsen, K.D.5
-
7
-
-
0035111731
-
A 3D electrical impedance tomography (EIT) system for breast cancer detection
-
V. Cherepenin, A. Karpov, A. Korjenevsky, V. Kornienko, A. Mazaletskaya, D. Mazourov, and D. Meister, "A 3D electrical impedance tomography (EIT) system for breast cancer detection," Physiol. Meas., vol.22, pp. 9-18, 2001.
-
(2001)
Physiol. Meas.
, vol.22
, pp. 9-18
-
-
Cherepenin, V.1
Karpov, A.2
Korjenevsky, A.3
Kornienko, V.4
Mazaletskaya, A.5
Mazourov, D.6
Meister, D.7
-
8
-
-
0033800291
-
Electrical impedance scanning for classifying suspicious breast lesions: First results
-
A. Malich, T. Fritsch, R. Anderson, T. Boehm, M. G. Freesmeyer, M. Fleck, and W. A. Kaiser, "Electrical impedance scanning for classifying suspicious breast lesions: First results," Eur. Radiol., vol.10, pp. 1555-1561, 2000.
-
(2000)
Eur. Radiol.
, vol.10
, pp. 1555-1561
-
-
Malich, A.1
Fritsch, T.2
Anderson, R.3
Boehm, T.4
Freesmeyer, M.G.5
Fleck, M.6
Kaiser, W.A.7
-
9
-
-
0031911234
-
The impedivity of freshly excised human breast tissue
-
J. Jossinet, "The impedivity of freshly excised human breast tissue," Physiol. Meas., vol.19, pp. 61-75, 1998.
-
(1998)
Physiol. Meas.
, vol.19
, pp. 61-75
-
-
Jossinet, J.1
-
10
-
-
0032988025
-
A review of parameters for the bioelectrical characterization of breast tissue
-
J. Jossinet and M. Schmitt, "A review of parameters for the bioelectrical characterization of breast tissue," Ann. New York Acad. Sci., vol.873, pp. 30-41, 1999.
-
(1999)
Ann. New York Acad. Sci.
, vol.873
, pp. 30-41
-
-
Jossinet, J.1
Schmitt, M.2
-
11
-
-
57649222551
-
An electrical impedance spectroscopy system for breast cancer detection
-
Aug.
-
G. Saulnier, N. Liu, C. P. Tamma, H. Xia, T.-J. Kao, J. Newell, and D. Isaacson, "An electrical impedance spectroscopy system for breast cancer detection," in Proc. IEEE EMBC, Aug. 2007, pp. 4154-4157.
-
(2007)
Proc. IEEE EMBC
, pp. 4154-4157
-
-
Saulnier, G.1
Liu, N.2
Tamma, C.P.3
Xia, H.4
Kao, T.-J.5
Newell, J.6
Isaacson, D.7
-
12
-
-
34447105562
-
ACT4: A high-precision, multi-frequency electrical impedance tomograph
-
London, U.K., Jun.
-
N. Liu, G. J. Saulnier, J. C. Newell, D. Isaacson, and T.-J. Kao, "ACT4: A high-precision, multi-frequency electrical impedance tomograph," in Proc. 6th Conf. Biomed. Appl. Electr. Impedance Tomogr. Univ. College London, London, U.K., Jun. 2005.
-
(2005)
Proc. 6th Conf. Biomed. Appl. Electr. Impedance Tomogr. Univ. College London
-
-
Liu, N.1
Saulnier, G.J.2
Newell, J.C.3
Isaacson, D.4
Kao, T.-J.5
-
13
-
-
0030711575
-
Digital tomosynthesis in breast imaging
-
L. T. Niklason, B. T. Christian, L. E. Niklason, D. B. Kopans, D. E. Castleberry, B. H. Opsahl-Ong, C. E. Landberg, P. J. Slanetz, A. A. Giardino, R. Moore, D. Albagli, M. C. DeJule, P. E. Fitzgerald, D. F. Fobare, B. W. Giambattista, R. F. Kwasnick, J. Liu, S. J. Lubowski, G. E. Possin, J. F. R. C. Y. Wei, and R. F. Wirth, "Digital tomosynthesis in breast imaging," Radiology, vol.205, pp. 399-406, 1997.
-
(1997)
Radiology
, vol.205
, pp. 399-406
-
-
Niklason, L.T.1
Christian, B.T.2
Niklason, L.E.3
Kopans, D.B.4
Castleberry, D.E.5
Opsahl-Ong, B.H.6
Landberg, C.E.7
Slanetz, P.J.8
Giardino, A.A.9
Moore, R.10
Albagli, D.11
Dejule, M.C.12
Fitzgerald, P.E.13
Fobare, D.F.14
Giambattista, B.W.15
Kwasnick, R.F.16
Liu, J.17
Lubowski, S.J.18
Possin, G.E.19
Wei, J.F.R.C.Y.20
Wirth, R.F.21
more..
-
14
-
-
34447097774
-
A compensated radiolucent electrode array for combined EITand mammography
-
T.-J. Kao, G. J. Saulnier, H. Xia, C. Tamma, J. C. Newell, and D. Isaacson, "A compensated radiolucent electrode array for combined EITand mammography," Physiol. Meas., vol.28, no.7, pp. S291-S299, 2007.
-
(2007)
Physiol. Meas.
, vol.28
, Issue.7
-
-
Kao, T.-J.1
Saulnier, G.J.2
Xia, H.3
Tamma, C.4
Newell, J.C.5
Isaacson, D.6
-
15
-
-
0024731083
-
Electrode models for electric current computed tomography
-
Sep.
-
K.-S. Cheng, D. Isaacson, J. C. Newell, and D. G. Gisser, "Electrode models for electric current computed tomography," IEEE Trans. Biomed. Eng., vol.36, no.9, pp. 918-924, Sep. 1989.
-
(1989)
IEEE Trans. Biomed. Eng.
, vol.36
, Issue.9
, pp. 918-924
-
-
Cheng, K.-S.1
Isaacson, D.2
Newell, J.C.3
Gisser, D.G.4
-
16
-
-
0026907944
-
Existence and uniqueness for electrode models for electric current computed tomography
-
E. Somersalo, M. Cheney, and D. Isaacson, "Existence and uniqueness for electrode models for electric current computed tomography," SIAM J. Appl. Math., vol.4, pp. 1023-1040, 1992.
-
(1992)
SIAM J. Appl. Math.
, vol.4
, pp. 1023-1040
-
-
Somersalo, E.1
Cheney, M.2
Isaacson, D.3
-
17
-
-
34447095948
-
The complete electrode model for EIT in a mammography geometry
-
DOI 10.1088/0967-3334/28/7/S05, PII S0967333407392266, S05
-
B. S. Kim, G. Boverman, J. C. Newell, G. J. Saulnier, and D. Isaacson, "The complete electrode model for EIT in a mammography geometry," Physiol. Meas., vol.28, no.7, pp. S57-S69, 2007. (Pubitemid 47028472)
-
(2007)
Physiological Measurement
, vol.28
, Issue.7
-
-
Kim, B.S.1
Boverman, G.2
Newell, J.C.3
Saulnier, G.J.4
Isaacson, D.5
-
18
-
-
1342268923
-
Accounting for erroneous electrode data in electrical impedance tomography
-
A. Adler, "Accounting for erroneous electrode data in electrical impedance tomography," Physiol. Meas., vol.25, pp. 227-238, 2004.
-
(2004)
Physiol. Meas.
, vol.25
, pp. 227-238
-
-
Adler, A.1
-
19
-
-
33947532625
-
A reconstruction algorithm for breast cancer imaging with electrical impedance tomography in mammography geometry
-
Apr.
-
M. H. Choi, T.-J. Kao, D. Isaacson, G. J. Saulnier, and J. C. Newell, "A reconstruction algorithm for breast cancer imaging with electrical impedance tomography in mammography geometry," IEEE Trans. Biomed. Eng., vol.54, no.4, pp. 700-710, Apr. 2007.
-
(2007)
IEEE Trans. Biomed. Eng.
, vol.54
, Issue.4
, pp. 700-710
-
-
Choi, M.H.1
Kao, T.-J.2
Isaacson, D.3
Saulnier, G.J.4
Newell, J.C.5
-
20
-
-
0022734022
-
Distinguishability of conductivities by electric current computed tomography
-
Jun.
-
D. Isaacson, "Distinguishability of conductivities by electric current computed tomography," IEEE Trans. Med. Imag., vol.5, no.2, pp. 91-95, Jun. 1986.
-
(1986)
IEEE Trans. Med. Imag.
, vol.5
, Issue.2
, pp. 91-95
-
-
Isaacson, D.1
-
21
-
-
0036991819
-
Simultaneous reconstruction of electrode contact impedances and internal electrical properties: I. Theory
-
DOI 10.1088/0957-0233/13/12/307, PII S095702330235416X
-
T. Vilhunen, J. P. Kaipio, P. J. Vauhkonen, T. Savolainen, and M. Vauhkonen, "Simultaneous reconstruction of electrode contact impedances and internal electrical properties: I. Theory," Meas. Sci. Technol., vol.13, pp. 1848-1854, 2002. (Pubitemid 36225156)
-
(2002)
Measurement Science and Technology
, vol.13
, Issue.12
, pp. 1848-1854
-
-
Vilhunen, T.1
Kaipio, J.P.2
Vauhkonen, P.J.3
Savolainen, T.4
Vauhkonen, M.5
-
22
-
-
0036991879
-
Simultaneous reconstruction of electrode contact impedances and internal electrical properties: II. Laboratory experiments
-
DOI 10.1088/0957-0233/13/12/308, PII S0957023302354225
-
L. Heikkinen, T. Vilhunen, R. M. West, and M. Vauhkonen, "Simultaneous reconstruction of electrode contact impedances and internal electrical properties: II. Laboratory experiments," Meas. Sci. Technol., vol.13, pp. 1855-1861, 2002. (Pubitemid 36225157)
-
(2002)
Measurement Science and Technology
, vol.13
, Issue.12
, pp. 1855-1861
-
-
Heikkinen, L.M.1
Vilhunen, T.2
West, R.M.3
Vauhkonen, M.4
-
23
-
-
0032819129
-
Three-dimensional electrical impedance tomography based on the complete electrode model
-
Sep.
-
P. J. Vauhkonen, M. Vauhkonen, T. Savolainen, and J. P. Kaipio, "Three-dimensional electrical impedance tomography based on the complete electrode model," IEEE Trans. Biomed. Eng., vol.46, no.9, pp. 1150-1160, Sep. 1999.
-
(1999)
IEEE Trans. Biomed. Eng.
, vol.46
, Issue.9
, pp. 1150-1160
-
-
Vauhkonen, P.J.1
Vauhkonen, M.2
Savolainen, T.3
Kaipio, J.P.4
-
24
-
-
0037763001
-
Distinguishability of inhomogeneities using planar electrode arrays and different patterns of applied excitation
-
T.-J.Kao, J. C.Newell, G. J. Saulnier, and D. Isaacson, "Distinguishability of inhomogeneities using planar electrode arrays and different patterns of applied excitation," Physiol. Meas., vol.24, pp. 403-411, 2003.
-
(2003)
Physiol. Meas.
, vol.24
, pp. 403-411
-
-
Kao, T.-J.1
Newell, J.C.2
Saulnier, G.J.3
Isaacson, D.4
-
25
-
-
84980246936
-
NOSER: An algorithm for solving the inverse conductivity problem
-
M. Cheney, D. Isaacson, J. C. Newell, S. Simske, and J. Goble, "NOSER: An algorithm for solving the inverse conductivity problem," Int. J. Imag. Syst. Technol., vol.2, pp. 66-75, 1990.
-
(1990)
Int. J. Imag. Syst. Technol.
, vol.2
, pp. 66-75
-
-
Cheney, M.1
Isaacson, D.2
Newell, J.C.3
Simske, S.4
Goble, J.5
|