메뉴 건너뛰기




Volumn 56, Issue 12, 2009, Pages 2762-2772

Methods for compensating for variable electrode contact in EIT

Author keywords

Breast cancer screening; Electrode contact; Image reconstruction; Impedance tomography; Inverse problems

Indexed keywords

3D RECONSTRUCTION; BREAST CANCER; BREAST CANCER SCREENING; CAPACITIVE EFFECT; CLINICAL DATA; CLINICAL SETTINGS; COMPENSATION ALGORITHM; COMPLETE ELECTRODE MODEL; CONTACT IMPEDANCE; DIRICHLET; DIRICHLET-TO-NEUMANN MAP; ELECTRICAL IMPEDANCE TOMOGRAPHY; ELECTRODE CONTACT; ELECTRODE CONTACTS; ELECTRODE SURFACES; EXPERIMENTAL APPARATUS; IMAGING MODALITY; IMPEDANCE TOMOGRAPHY; ITERATIVE OPTIMIZATION; LEVENBERG-MARQUARDT; LINEARIZED ALGORITHMS; PROPER MODELING; RECONSTRUCTION ALGORITHMS; SPATIAL DISTRIBUTION;

EID: 72649093164     PISSN: 00189294     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBME.2009.2027129     Document Type: Article
Times cited : (30)

References (25)
  • 2
    • 0035722843 scopus 로고    scopus 로고
    • Three-dimensional electrical impedance tomography of human brain activity
    • T. Tidswell, A. Gibson, R. H. Bayford, and D. S. Holder, "Three-dimensional electrical impedance tomography of human brain activity," Neuroimage, vol.13, pp. 283-294, 2001.
    • (2001) Neuroimage , vol.13 , pp. 283-294
    • Tidswell, T.1    Gibson, A.2    Bayford, R.H.3    Holder, D.S.4
  • 3
    • 34447106876 scopus 로고    scopus 로고
    • Reproducibility of regional lung ventilation distribution determined by electrical impedance tomography during mechanical ventilation
    • I. Frerichs, G. Schmitz, S. Pulletz, D. Schadler, G. Zick, J. Scholz, and N. Weiler, "Reproducibility of regional lung ventilation distribution determined by electrical impedance tomography during mechanical ventilation," Physiol. Meas., vol.28, no.7, pp. S261-S267, 2007.
    • (2007) Physiol. Meas. , vol.28 , Issue.7
    • Frerichs, I.1    Schmitz, G.2    Pulletz, S.3    Schadler, D.4    Zick, G.5    Scholz, J.6    Weiler, N.7
  • 4
    • 0028276263 scopus 로고
    • A comparison of ventilatory and cardiac related changes in EIT images of normal human lungs and of lungs with pulmonary emboli
    • A. D. Leathard, B. H. Brown, J. H. Campbell, F. Z. A. H. Morice, and D. Taylor, "A comparison of ventilatory and cardiac related changes in EIT images of normal human lungs and of lungs with pulmonary emboli," Phyisiol. Meas., vol. 15, no. 2A, pp. A137-A146, 1994.
    • (1994) Phyisiol. Meas. , vol.15 , Issue.2 A
    • Leathard, A.D.1    Brown, B.H.2    Campbell, J.H.3    Morice, F.Z.A.H.4    Taylor, D.5
  • 5
    • 0036591481 scopus 로고    scopus 로고
    • Electrical impedance spectroscopy of the breast: Clinical imaging results in 26 subjects
    • Jun.
    • T. E. Kerner, K. D. Paulsen, A. Hartov, S. K. Soho, and S. P. Poplack, "Electrical impedance spectroscopy of the breast: Clinical imaging results in 26 subjects," IEEE Trans.Med. Imag., vol.21, no.6, pp. 638-645, Jun. 2002.
    • (2002) IEEE Trans.Med. Imag. , vol.21 , Issue.6 , pp. 638-645
    • Kerner, T.E.1    Paulsen, K.D.2    Hartov, A.3    Soho, S.K.4    Poplack, S.P.5
  • 6
    • 1342268914 scopus 로고    scopus 로고
    • Multifrequency electrical impedance tomography of the breast: New clinical results
    • N. Soni, A. Hartov, C. Kogel, S. P. Poplack, and K. D. Paulsen, "Multifrequency electrical impedance tomography of the breast: New clinical results," Physiol. Meas., vol.25, pp. 301-314, 2004.
    • (2004) Physiol. Meas. , vol.25 , pp. 301-314
    • Soni, N.1    Hartov, A.2    Kogel, C.3    Poplack, S.P.4    Paulsen, K.D.5
  • 8
  • 9
    • 0031911234 scopus 로고    scopus 로고
    • The impedivity of freshly excised human breast tissue
    • J. Jossinet, "The impedivity of freshly excised human breast tissue," Physiol. Meas., vol.19, pp. 61-75, 1998.
    • (1998) Physiol. Meas. , vol.19 , pp. 61-75
    • Jossinet, J.1
  • 10
    • 0032988025 scopus 로고    scopus 로고
    • A review of parameters for the bioelectrical characterization of breast tissue
    • J. Jossinet and M. Schmitt, "A review of parameters for the bioelectrical characterization of breast tissue," Ann. New York Acad. Sci., vol.873, pp. 30-41, 1999.
    • (1999) Ann. New York Acad. Sci. , vol.873 , pp. 30-41
    • Jossinet, J.1    Schmitt, M.2
  • 14
    • 34447097774 scopus 로고    scopus 로고
    • A compensated radiolucent electrode array for combined EITand mammography
    • T.-J. Kao, G. J. Saulnier, H. Xia, C. Tamma, J. C. Newell, and D. Isaacson, "A compensated radiolucent electrode array for combined EITand mammography," Physiol. Meas., vol.28, no.7, pp. S291-S299, 2007.
    • (2007) Physiol. Meas. , vol.28 , Issue.7
    • Kao, T.-J.1    Saulnier, G.J.2    Xia, H.3    Tamma, C.4    Newell, J.C.5    Isaacson, D.6
  • 15
    • 0024731083 scopus 로고
    • Electrode models for electric current computed tomography
    • Sep.
    • K.-S. Cheng, D. Isaacson, J. C. Newell, and D. G. Gisser, "Electrode models for electric current computed tomography," IEEE Trans. Biomed. Eng., vol.36, no.9, pp. 918-924, Sep. 1989.
    • (1989) IEEE Trans. Biomed. Eng. , vol.36 , Issue.9 , pp. 918-924
    • Cheng, K.-S.1    Isaacson, D.2    Newell, J.C.3    Gisser, D.G.4
  • 16
    • 0026907944 scopus 로고
    • Existence and uniqueness for electrode models for electric current computed tomography
    • E. Somersalo, M. Cheney, and D. Isaacson, "Existence and uniqueness for electrode models for electric current computed tomography," SIAM J. Appl. Math., vol.4, pp. 1023-1040, 1992.
    • (1992) SIAM J. Appl. Math. , vol.4 , pp. 1023-1040
    • Somersalo, E.1    Cheney, M.2    Isaacson, D.3
  • 17
    • 34447095948 scopus 로고    scopus 로고
    • The complete electrode model for EIT in a mammography geometry
    • DOI 10.1088/0967-3334/28/7/S05, PII S0967333407392266, S05
    • B. S. Kim, G. Boverman, J. C. Newell, G. J. Saulnier, and D. Isaacson, "The complete electrode model for EIT in a mammography geometry," Physiol. Meas., vol.28, no.7, pp. S57-S69, 2007. (Pubitemid 47028472)
    • (2007) Physiological Measurement , vol.28 , Issue.7
    • Kim, B.S.1    Boverman, G.2    Newell, J.C.3    Saulnier, G.J.4    Isaacson, D.5
  • 18
    • 1342268923 scopus 로고    scopus 로고
    • Accounting for erroneous electrode data in electrical impedance tomography
    • A. Adler, "Accounting for erroneous electrode data in electrical impedance tomography," Physiol. Meas., vol.25, pp. 227-238, 2004.
    • (2004) Physiol. Meas. , vol.25 , pp. 227-238
    • Adler, A.1
  • 19
    • 33947532625 scopus 로고    scopus 로고
    • A reconstruction algorithm for breast cancer imaging with electrical impedance tomography in mammography geometry
    • Apr.
    • M. H. Choi, T.-J. Kao, D. Isaacson, G. J. Saulnier, and J. C. Newell, "A reconstruction algorithm for breast cancer imaging with electrical impedance tomography in mammography geometry," IEEE Trans. Biomed. Eng., vol.54, no.4, pp. 700-710, Apr. 2007.
    • (2007) IEEE Trans. Biomed. Eng. , vol.54 , Issue.4 , pp. 700-710
    • Choi, M.H.1    Kao, T.-J.2    Isaacson, D.3    Saulnier, G.J.4    Newell, J.C.5
  • 20
    • 0022734022 scopus 로고
    • Distinguishability of conductivities by electric current computed tomography
    • Jun.
    • D. Isaacson, "Distinguishability of conductivities by electric current computed tomography," IEEE Trans. Med. Imag., vol.5, no.2, pp. 91-95, Jun. 1986.
    • (1986) IEEE Trans. Med. Imag. , vol.5 , Issue.2 , pp. 91-95
    • Isaacson, D.1
  • 21
    • 0036991819 scopus 로고    scopus 로고
    • Simultaneous reconstruction of electrode contact impedances and internal electrical properties: I. Theory
    • DOI 10.1088/0957-0233/13/12/307, PII S095702330235416X
    • T. Vilhunen, J. P. Kaipio, P. J. Vauhkonen, T. Savolainen, and M. Vauhkonen, "Simultaneous reconstruction of electrode contact impedances and internal electrical properties: I. Theory," Meas. Sci. Technol., vol.13, pp. 1848-1854, 2002. (Pubitemid 36225156)
    • (2002) Measurement Science and Technology , vol.13 , Issue.12 , pp. 1848-1854
    • Vilhunen, T.1    Kaipio, J.P.2    Vauhkonen, P.J.3    Savolainen, T.4    Vauhkonen, M.5
  • 22
    • 0036991879 scopus 로고    scopus 로고
    • Simultaneous reconstruction of electrode contact impedances and internal electrical properties: II. Laboratory experiments
    • DOI 10.1088/0957-0233/13/12/308, PII S0957023302354225
    • L. Heikkinen, T. Vilhunen, R. M. West, and M. Vauhkonen, "Simultaneous reconstruction of electrode contact impedances and internal electrical properties: II. Laboratory experiments," Meas. Sci. Technol., vol.13, pp. 1855-1861, 2002. (Pubitemid 36225157)
    • (2002) Measurement Science and Technology , vol.13 , Issue.12 , pp. 1855-1861
    • Heikkinen, L.M.1    Vilhunen, T.2    West, R.M.3    Vauhkonen, M.4
  • 23
    • 0032819129 scopus 로고    scopus 로고
    • Three-dimensional electrical impedance tomography based on the complete electrode model
    • Sep.
    • P. J. Vauhkonen, M. Vauhkonen, T. Savolainen, and J. P. Kaipio, "Three-dimensional electrical impedance tomography based on the complete electrode model," IEEE Trans. Biomed. Eng., vol.46, no.9, pp. 1150-1160, Sep. 1999.
    • (1999) IEEE Trans. Biomed. Eng. , vol.46 , Issue.9 , pp. 1150-1160
    • Vauhkonen, P.J.1    Vauhkonen, M.2    Savolainen, T.3    Kaipio, J.P.4
  • 24
    • 0037763001 scopus 로고    scopus 로고
    • Distinguishability of inhomogeneities using planar electrode arrays and different patterns of applied excitation
    • T.-J.Kao, J. C.Newell, G. J. Saulnier, and D. Isaacson, "Distinguishability of inhomogeneities using planar electrode arrays and different patterns of applied excitation," Physiol. Meas., vol.24, pp. 403-411, 2003.
    • (2003) Physiol. Meas. , vol.24 , pp. 403-411
    • Kao, T.-J.1    Newell, J.C.2    Saulnier, G.J.3    Isaacson, D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.