메뉴 건너뛰기




Volumn 25, Issue 1, 2004, Pages 227-238

Accounting for erroneous electrode data in electrical impedance tomography

Author keywords

Electrical impedance tomography; Electrodes; Image reconstruction

Indexed keywords

ELECTRIC IMPEDANCE; ELECTRIC IMPEDANCE MEASUREMENT; ELECTRIC IMPEDANCE TOMOGRAPHY; ELECTRODES; FINITE ELEMENT METHOD;

EID: 1342268923     PISSN: 09673334     EISSN: None     Source Type: Journal    
DOI: 10.1088/0967-3334/25/1/028     Document Type: Conference Paper
Times cited : (24)

References (15)
  • 1
    • 0030657934 scopus 로고    scopus 로고
    • Monitoring changes in lung air and liquid volumes with electrical impedance tomography
    • Adler A, Amyot R, Guardo R, Bates J H T and Berthiaume Y 1997 Monitoring changes in lung air and liquid volumes with electrical impedance tomography J. Appl. Physiol. 83 1762-7
    • (1997) J. Appl. Physiol. , vol.83 , pp. 1762-1767
    • Adler, A.1    Amyot, R.2    Guardo, R.3    Bates, J.H.T.4    Berthiaume, Y.5
  • 2
    • 0030126713 scopus 로고    scopus 로고
    • Electrical impedance tomography: Regularised imaging and contrast detection
    • Adler A and Guardo R 1996 Electrical impedance tomography: regularised imaging and contrast detection IEEE Trans. Med. Imaging 15 170-9
    • (1996) IEEE Trans. Med. Imaging , vol.15 , pp. 170-179
    • Adler, A.1    Guardo, R.2
  • 3
    • 0030130896 scopus 로고    scopus 로고
    • Impedance imaging of lung ventilation: Do we need to account for chest expansion?
    • Adler A, Guardo R and Berthiaume Y 1996 Impedance imaging of lung ventilation: do we need to account for chest expansion? IEEE Trans. Biomed. Eng. 43 414-21
    • (1996) IEEE Trans. Biomed. Eng. , vol.43 , pp. 414-421
    • Adler, A.1    Guardo, R.2    Berthiaume, Y.3
  • 4
    • 0031834864 scopus 로고    scopus 로고
    • Patient-instrument connection errors in bioelectrical impedance measurement
    • Al-Hatib F 1998 Patient-instrument connection errors in bioelectrical impedance measurement Physiol. Meas. 19 285-96
    • (1998) Physiol. Meas. , vol.19 , pp. 285-296
    • Al-Hatib, F.1
  • 6
    • 0036591474 scopus 로고    scopus 로고
    • Propagation of measurement noise through backprojection reconstruction in electrical impedance tomography
    • Frangi A F, Riu P J, Rosell J and Viergever M A 2002 Propagation of measurement noise through backprojection reconstruction in electrical impedance tomography IEEE Trans. Med. Imaging 21 566-78
    • (2002) IEEE Trans. Med. Imaging , vol.21 , pp. 566-578
    • Frangi, A.F.1    Riu, P.J.2    Rosell, J.3    Viergever, M.A.4
  • 7
    • 0014986362 scopus 로고
    • An application of electrocardiographic lead theory to impedance plethysmography
    • Geselowitz D B 1971 An application of electrocardiographic lead theory to impedance plethysmography IEEE Trans. Biomed. Eng. 18 38-41
    • (1971) IEEE Trans. Biomed. Eng. , vol.18 , pp. 38-41
    • Geselowitz, D.B.1
  • 8
    • 0026190472 scopus 로고
    • An experimental study in electrical impedance tomography using backprojection reconstruction
    • Guardo R, Boulay C, Murray B and Bertrand M 1991 An experimental study in electrical impedance tomography using backprojection reconstruction IEEE Trans. Biomed. Eng. 38 617-27
    • (1991) IEEE Trans. Biomed. Eng. , vol.38 , pp. 617-627
    • Guardo, R.1    Boulay, C.2    Murray, B.3    Bertrand, M.4
  • 9
    • 0034003982 scopus 로고    scopus 로고
    • Movement artefact rejection in impedance pneumography using six strategically placed electrodes
    • Khambete N D, Brown B H and Smallwood R H 2000 Movement artefact rejection in impedance pneumography using six strategically placed electrodes Physiol. Meas. 21 79-88
    • (2000) Physiol. Meas. , vol.21 , pp. 79-88
    • Khambete, N.D.1    Brown, B.H.2    Smallwood, R.H.3
  • 10
    • 0028998912 scopus 로고
    • Errors in prolonged electrical impedance measurements due to electrode repositioning and postural changes
    • Lozano A, Rosell J and Pallás-Areny R 1995 Errors in prolonged electrical impedance measurements due to electrode repositioning and postural changes Physiol. Meas. 16 121-30
    • (1995) Physiol. Meas. , vol.16 , pp. 121-130
    • Lozano, A.1    Rosell, J.2    Pallás-Areny, R.3
  • 11
    • 0029807203 scopus 로고    scopus 로고
    • EIT data noise evaluation in the clinical environment
    • Meeson S, Blott B and Killingback A 1996 EIT data noise evaluation in the clinical environment Physiol. Meas. 17 (Suppl.) A33-8
    • (1996) Physiol. Meas. , vol.17 , Issue.SUPPL.
    • Meeson, S.1    Blott, B.2    Killingback, A.3
  • 12
    • 0036994840 scopus 로고    scopus 로고
    • A Matlab toolkit for three-dimensional electrical impedance tomography: A contribution to the electrical impedance and diffuse optical reconstruction software project
    • Polydorides N and Lionheart W R B 2002 A Matlab toolkit for three-dimensional electrical impedance tomography: a contribution to the electrical impedance and diffuse optical reconstruction software project Meas. Sci. Technol. 13 1871-83
    • (2002) Meas. Sci. Technol. , vol.13 , pp. 1871-1883
    • Polydorides, N.1    Lionheart, W.R.B.2
  • 13
    • 0020858683 scopus 로고
    • Errors in four-electrode impedance plethysmography
    • Swanson D K and Webster J G 1983 Errors in four-electrode impedance plethysmography Med. Biol. Eng. Comput. 21 674-80
    • (1983) Med. Biol. Eng. Comput. , vol.21 , pp. 674-680
    • Swanson, D.K.1    Webster, J.G.2
  • 15
    • 0036173938 scopus 로고    scopus 로고
    • A comparison of methods for measurement of spatial resolution in two-dimensional circular EIT images
    • Wheeler J L, Wang W and Tang M 2002 A comparison of methods for measurement of spatial resolution in two-dimensional circular EIT images Physiol. Meas. 23 169-76
    • (2002) Physiol. Meas. , vol.23 , pp. 169-176
    • Wheeler, J.L.1    Wang, W.2    Tang, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.