메뉴 건너뛰기




Volumn 25, Issue 1, 2004, Pages 301-314

Multi-frequency electrical impedance tomography of the breast: New clinical results

Author keywords

Breast cancer screening; Breast imaging; Electrical impedance tomography

Indexed keywords

ELECTRIC IMPEDANCE MEASUREMENT; ELECTRIC IMPEDANCE TOMOGRAPHY; FINITE ELEMENT METHOD; IMAGE RECONSTRUCTION; MAMMOGRAPHY; PERMITTIVITY; TISSUE; X RAY SCREENS;

EID: 1342268914     PISSN: 09673334     EISSN: None     Source Type: Journal    
DOI: 10.1088/0967-3334/25/1/034     Document Type: Conference Paper
Times cited : (47)

References (17)
  • 2
    • 0023078061 scopus 로고
    • Mathematical aspects of impedance imaging
    • Breckon W R and Pidcock M K 1987 Mathematical aspects of impedance imaging Clin. Phys. Physiol. Meas. 8 (Suppl. A) 77-84
    • (1987) Clin. Phys. Physiol. Meas. , vol.8 , Issue.SUPPL. A , pp. 77-84
    • Breckon, W.R.1    Pidcock, M.K.2
  • 3
    • 0035422836 scopus 로고    scopus 로고
    • Medical impedance tomography and process impedance tomography: A brief review
    • Brown B H 2001 Medical impedance tomography and process impedance tomography: a brief review Meas. Sci. Technol. 12 991-6
    • (2001) Meas. Sci. Technol. , vol.12 , pp. 991-996
    • Brown, B.H.1
  • 9
    • 0027096024 scopus 로고
    • Electrical impedance tomography (EIT) of brain function
    • Holder D S 1992 Electrical impedance tomography (EIT) of brain function Brain Topogr. 5 87-93
    • (1992) Brain Topogr. , vol.5 , pp. 87-93
    • Holder, D.S.1
  • 12
    • 0029066254 scopus 로고
    • Tissue impedance: A historical overview
    • McAdams E T and Jossinet J 1995 Tissue impedance: a historical overview Physiol. Meas. 16 A1-13
    • (1995) Physiol. Meas. , vol.16
    • McAdams, E.T.1    Jossinet, J.2
  • 13
    • 0035117774 scopus 로고    scopus 로고
    • Reconstruction of conductivity changes due to ventilation and perfusion from EIT data collected on a rectangular electrode array
    • Mueller J L, Isaacson D and Newell J C 2001 Reconstruction of conductivity changes due to ventilation and perfusion from EIT data collected on a rectangular electrode array Physiol. Meas. 22 97-106
    • (2001) Physiol. Meas. , vol.22 , pp. 97-106
    • Mueller, J.L.1    Isaacson, D.2    Newell, J.C.3
  • 15
    • 0030779777 scopus 로고    scopus 로고
    • An enhanced electrical impedance imaging algorithm for hyperthermia applications
    • Paulsen K D and Jiang H 1997 An enhanced electrical impedance imaging algorithm for hyperthermia applications J. Hyperthermia 13 459-80
    • (1997) J. Hyperthermia , vol.13 , pp. 459-480
    • Paulsen, K.D.1    Jiang, H.2
  • 16
    • 0028300005 scopus 로고
    • Temperature field estimation using electrical impedance profiling methods: 1. Reconstruction algorithms and simulated results
    • Paulsen K D, Moskowitz K M and Ryan T P 1994 Temperature field estimation using electrical impedance profiling methods: 1. Reconstruction algorithms and simulated results Int. J. Hyperthermia 10 209-28
    • (1994) Int. J. Hyperthermia , vol.10 , pp. 209-228
    • Paulsen, K.D.1    Moskowitz, K.M.2    Ryan, T.P.3
  • 17
    • 0037762998 scopus 로고    scopus 로고
    • A novel data calibration scheme for electrical impedance tomography
    • Soni N K, Dehghani H, Hartov A and Paulsen K D 2003 A novel data calibration scheme for electrical impedance tomography Physiol. Meas. 24 421-35
    • (2003) Physiol. Meas. , vol.24 , pp. 421-435
    • Soni, N.K.1    Dehghani, H.2    Hartov, A.3    Paulsen, K.D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.