메뉴 건너뛰기




Volumn 114, Issue 1-3, 2005, Pages 109-113

Nodule detection in digital chest radiography: Effect of anatomical noise

Author keywords

[No Author keywords available]

Indexed keywords

AREA UNDER THE CURVE; ARTICLE; CLINICAL ARTICLE; CONTRAST ENHANCEMENT; DIAGNOSTIC VALUE; DIGITAL RADIOGRAPHY; HUMAN; IMAGE ANALYSIS; LUNG NODULE; MEDIASTINUM; NOISE REDUCTION; PATHOLOGICAL ANATOMY; RECEIVER OPERATING CHARACTERISTIC; SIMULATION; THORAX RADIOGRAPHY;

EID: 21244443851     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/rpd/nch526     Document Type: Article
Times cited : (42)

References (11)
  • 1
    • 0041374380 scopus 로고    scopus 로고
    • Measurement of the noise components in the medical x-ray intensity pattern due to overlaying nonrecognizable structures
    • Tischenko, O., Hoeschen, C., Effenberger, O., Reissberg, S., Buhr, E. and Doehring, W. Measurement of the noise components in the medical x-ray intensity pattern due to overlaying nonrecognizable structures. Proc. SPIE 5030, 422-432 (2003).
    • (2003) Proc. SPIE , vol.5030 , pp. 422-432
    • Tischenko, O.1    Hoeschen, C.2    Effenberger, O.3    Reissberg, S.4    Buhr, E.5    Doehring, W.6
  • 2
    • 21244480572 scopus 로고    scopus 로고
    • Comparison of technical and anatomical noise in digital thorax X-ray images
    • Hoeschen, C., Tischenko, O., Buhr, E. and Illers, H. Comparison of technical and anatomical noise in digital thorax X-ray images. Radiat. Prot. Dosim. 114(1-3), 75-80 (2005).
    • (2005) Radiat. Prot. Dosim. , vol.114 , Issue.1-3 , pp. 75-80
    • Hoeschen, C.1    Tischenko, O.2    Buhr, E.3    Illers, H.4
  • 3
    • 21244485877 scopus 로고    scopus 로고
    • Reduction of anatomical noise in medical X-ray images
    • Tischenko, O., Hoeschen, C. and Buhr, E. Reduction of anatomical noise in medical X-ray images. Radiat. Prot. Dosim. 114(1-3), 69-74 (2005).
    • (2005) Radiat. Prot. Dosim. , vol.114 , Issue.1-3 , pp. 69-74
    • Tischenko, O.1    Hoeschen, C.2    Buhr, E.3
  • 10
    • 58749093910 scopus 로고    scopus 로고
    • Nodule detection in two component noise: Toward patient structure
    • Burgess, A. E., Li, X. and Abbey, C. K. Nodule detection in two component noise: toward patient structure. Proc. SPIE 3036, 2-13 (1997).
    • (1997) Proc. SPIE , vol.3036 , pp. 2-13
    • Burgess, A.E.1    Li, X.2    Abbey, C.K.3
  • 11
    • 21244499800 scopus 로고    scopus 로고
    • A software tool for increased efficiency in observer performance studies in radiology
    • and 10 others
    • Börjesson, S. and 10 others. A software tool for increased efficiency in observer performance studies in radiology. Radiat. Prot. Dosim. 114(1-3), 45-52 (2005).
    • (2005) Radiat. Prot. Dosim. , vol.114 , Issue.1-3 , pp. 45-52
    • Börjesson, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.