메뉴 건너뛰기




Volumn 23, Issue 2, 2008, Pages 86-92

Digital tomosynthesis of the chest

Author keywords

Chest radiography; Digital tomosynthesis; Pulmonary nodule

Indexed keywords

AIRWAY; ALGORITHM; DIGITAL TOMOSYNTHESIS; HUMAN; IMAGE PROCESSING; IMAGING SYSTEM; LUNG NODULE; RADIODIAGNOSIS; REVIEW; SPINE; THORAX; THORAX RADIOGRAPHY; THREE DIMENSIONAL IMAGING; X RAY TUBE; COMPUTER ASSISTED DIAGNOSIS; IMAGE QUALITY; LUNG; LUNG DISEASE; LUNG TUMOR; METHODOLOGY; RADIOGRAPHY; SIGNAL PROCESSING;

EID: 54049126162     PISSN: 08835993     EISSN: None     Source Type: Journal    
DOI: 10.1097/RTI.0b013e318173e162     Document Type: Review
Times cited : (74)

References (57)
  • 1
    • 0018239314 scopus 로고
    • Radiographic screening in the early detection of lung cancer
    • Stitik FP, Tockman MS. Radiographic screening in the early detection of lung cancer. Radiol Clin N Am. 1978;16:347-366.
    • (1978) Radiol Clin N Am , vol.16 , pp. 347-366
    • Stitik, F.P.1    Tockman, M.S.2
  • 2
    • 0020606057 scopus 로고
    • Lung cancer detected during a screening program using four-month chest radiographs
    • Muhm JR, Miller WE, Fontana RS, et al. Lung cancer detected during a screening program using four-month chest radiographs. Radiology. 1983;148:609-615.
    • (1983) Radiology , vol.148 , pp. 609-615
    • Muhm, J.R.1    Miller, W.E.2    Fontana, R.S.3
  • 3
    • 0022456273 scopus 로고
    • Calcification in pulmonary nodules: Detection with dual-energy digital radiography
    • Fraser RG, Hickey NM, Niklason LT, et al. Calcification in pulmonary nodules: detection with dual-energy digital radiography. Radiology. 1986;160:595-601.
    • (1986) Radiology , vol.160 , pp. 595-601
    • Fraser, R.G.1    Hickey, N.M.2    Niklason, L.T.3
  • 4
    • 0023878862 scopus 로고
    • One-shot dual-energy subtraction chest imaging with computed radiography: Clinical evaluation of film images
    • Ishigaki T, Sakuma S, Ikeda M. One-shot dual-energy subtraction chest imaging with computed radiography: clinical evaluation of film images. Radiology. 1988;168:67-72.
    • (1988) Radiology , vol.168 , pp. 67-72
    • Ishigaki, T.1    Sakuma, S.2    Ikeda, M.3
  • 5
    • 0024405390 scopus 로고
    • Single-exposure dual-energy digital radiography in the detection of pulmonary nodules and calcifications
    • Oestmann JW, Greene R, Rhea JT, et al. "Single-exposure" dual-energy digital radiography in the detection of pulmonary nodules and calcifications. Invest Radiol. 1989;24:517-521.
    • (1989) Invest Radiol , vol.24 , pp. 517-521
    • Oestmann, J.W.1    Greene, R.2    Rhea, J.T.3
  • 6
    • 0025095292 scopus 로고
    • Single-exposure dual-energy computed radiography: Improved detection and processing
    • Ergun DL, Mistretta CA, Brown DE, et al. Single-exposure dual-energy computed radiography: improved detection and processing. Radiology. 1990;174:243-249.
    • (1990) Radiology , vol.174 , pp. 243-249
    • Ergun, D.L.1    Mistretta, C.A.2    Brown, D.E.3
  • 7
    • 0028082160 scopus 로고
    • Conventional chest radiography vs dual-energy computed radiography in the detection and characterization of pulmonary nodules
    • Kelcz F, Zink FE, Peppler WW, et al. Conventional chest radiography vs dual-energy computed radiography in the detection and characterization of pulmonary nodules. AJR. 1994;162:271-278.
    • (1994) AJR , vol.162 , pp. 271-278
    • Kelcz, F.1    Zink, F.E.2    Peppler, W.W.3
  • 8
    • 0347531752 scopus 로고    scopus 로고
    • Clinical results of CsI-detector-based dual-exposure dual energy in chest radiography
    • Ricke J, Fischbach F, Freund T, et al. Clinical results of CsI-detector-based dual-exposure dual energy in chest radiography. Eur Radiol. 2003;13:2577-2582.
    • (2003) Eur Radiol , vol.13 , pp. 2577-2582
    • Ricke, J.1    Fischbach, F.2    Freund, T.3
  • 9
    • 0344412986 scopus 로고    scopus 로고
    • Dual-energy chest radiography with a flat-panel digital detector: Revealing calcified chest abnormalities
    • Fischbach F, Freund T, Röttgen R, et al. Dual-energy chest radiography with a flat-panel digital detector: revealing calcified chest abnormalities. AJR. 2003;181:1519-1524.
    • (2003) AJR , vol.181 , pp. 1519-1524
    • Fischbach, F.1    Freund, T.2    Röttgen, R.3
  • 10
    • 0033542870 scopus 로고    scopus 로고
    • Early lung cancer action project: Overall design and findings from baseline screening
    • Henschke CI, McCauley DI, Yankelevitz DF, et al. Early lung cancer action project: overall design and findings from baseline screening. Lancet. 1999;354:99-105.
    • (1999) Lancet , vol.354 , pp. 99-105
    • Henschke, C.I.1    McCauley, D.I.2    Yankelevitz, D.F.3
  • 11
    • 0035396169 scopus 로고    scopus 로고
    • Early lung cancer action project: Initial findings on repeat screenings
    • Henschke CI, Naidich DP, Yankelevitz DF, et al. Early lung cancer action project: initial findings on repeat screenings. Cancer. 2001;92: 153-159.
    • (2001) Cancer , vol.92 , pp. 153-159
    • Henschke, C.I.1    Naidich, D.P.2    Yankelevitz, D.F.3
  • 12
    • 0035680449 scopus 로고    scopus 로고
    • Early lung caner action project: Annual screening using single-slice helical CT
    • Henschke CI, Yankelevitz DF, Libby DM, et al. Early lung caner action project: annual screening using single-slice helical CT. Ann NY Acad Sci. 2001;952:124-134.
    • (2001) Ann NY Acad Sci , vol.952 , pp. 124-134
    • Henschke, C.I.1    Yankelevitz, D.F.2    Libby, D.M.3
  • 13
    • 0036109223 scopus 로고    scopus 로고
    • CT screening for lung cancer: Frequency and significance of part-solid and nonsolid nodules
    • Henschke CI, Yankelevitz DF, Mirtcheva R, et al. CT screening for lung cancer: frequency and significance of part-solid and nonsolid nodules. AJR. 2002;178:1053-1057.
    • (2002) AJR , vol.178 , pp. 1053-1057
    • Henschke, C.I.1    Yankelevitz, D.F.2    Mirtcheva, R.3
  • 15
    • 33750315764 scopus 로고    scopus 로고
    • Survival of patients with stage I lung cancer detected on CT screening
    • Henschke CI, Yankelevitz DF, Libby DM, et al. Survival of patients with stage I lung cancer detected on CT screening. N Engl J Med. 2006;355:1763-1771.
    • (2006) N Engl J Med , vol.355 , pp. 1763-1771
    • Henschke, C.I.1    Yankelevitz, D.F.2    Libby, D.M.3
  • 16
    • 21044449227 scopus 로고    scopus 로고
    • Imaging and cancer: Research strategy of the American College of Radiology Imaging Network
    • Aberle DR, Chiles C, Gatsonis C, et al. Imaging and cancer: research strategy of the American College of Radiology Imaging Network. Radiology. 2005;235:741-751.
    • (2005) Radiology , vol.235 , pp. 741-751
    • Aberle, D.R.1    Chiles, C.2    Gatsonis, C.3
  • 17
    • 0037083775 scopus 로고    scopus 로고
    • Screening for lung cancer with low-dose spiral computed tomography
    • Swensen SJ, Jett JR, Sloan JA, et al. Screening for lung cancer with low-dose spiral computed tomography. Am J Respir Crit Care Med. 2002;165:508-513.
    • (2002) Am J Respir Crit Care Med , vol.165 , pp. 508-513
    • Swensen, S.J.1    Jett, J.R.2    Sloan, J.A.3
  • 18
    • 33846408647 scopus 로고    scopus 로고
    • Five-year lung cancer screening experience: CT appearance, growth rate, location, and histologic features of 61 lung cancers
    • Lindell RM, Hartman TE, Swensen SJ, et al. Five-year lung cancer screening experience: CT appearance, growth rate, location, and histologic features of 61 lung cancers. Radiology. 2007;242: 555-562.
    • (2007) Radiology , vol.242 , pp. 555-562
    • Lindell, R.M.1    Hartman, T.E.2    Swensen, S.J.3
  • 19
    • 33847691553 scopus 로고    scopus 로고
    • Computed tomography screening and lung cancer outcomes
    • Bach PB, Jett JR, Pastorino U, et al. Computed tomography screening and lung cancer outcomes. JAMA. 2007;297:953-961.
    • (2007) JAMA , vol.297 , pp. 953-961
    • Bach, P.B.1    Jett, J.R.2    Pastorino, U.3
  • 20
    • 84907127152 scopus 로고
    • Eine neue methode zur differenzierung in der roentgenographie (planigraphie)
    • Ziedses des Plantes BG. Eine neue methode zur differenzierung in der roentgenographie (planigraphie). Acta Radiol. 1932;13: 182-192.
    • (1932) Acta Radiol , vol.13 , pp. 182-192
    • Ziedses des Plantes, B.G.1
  • 21
    • 0015250017 scopus 로고
    • Tomosynthesis: A three-dimensional radiographic imaging technique
    • Grant DG. Tomosynthesis: a three-dimensional radiographic imaging technique. IEEE Trans Biomed Eng BMF. 1972;19:20-28.
    • (1972) IEEE Trans Biomed Eng BMF , vol.19 , pp. 20-28
    • Grant, D.G.1
  • 22
    • 0019156984 scopus 로고
    • Ectomography: A new radiographic method for reproducing a selected slice of varying thickness
    • Edholm P, Granlund G, Knutsson H, et al. Ectomography: a new radiographic method for reproducing a selected slice of varying thickness. Acta Radiol. 1980;21:433-442.
    • (1980) Acta Radiol , vol.21 , pp. 433-442
    • Edholm, P.1    Granlund, G.2    Knutsson, H.3
  • 23
    • 0021930986 scopus 로고
    • Selective plane removal in limited angle tomographic imaging
    • Ghosh Roy DN, Kruger RA, Yih B, et al. Selective plane removal in limited angle tomographic imaging. Med Phys. 1985;12:65-70.
    • (1985) Med Phys , vol.12 , pp. 65-70
    • Ghosh Roy, D.N.1    Kruger, R.A.2    Yih, B.3
  • 24
    • 0020573496 scopus 로고
    • Digital tomosynthesis: Technique for electronic reconstructive tomography
    • Maravilla KR, Murry RC Jr, Norner S. Digital tomosynthesis: technique for electronic reconstructive tomography. AJR. 1983;141:497-502.
    • (1983) AJR , vol.141 , pp. 497-502
    • Maravilla, K.R.1    Murry Jr, R.C.2    Norner, S.3
  • 26
    • 0013333233 scopus 로고    scopus 로고
    • Self-contained tomosynthetic, radiographic-imaging system, method and device.
    • US Patent, 5:668-844
    • Webber RL. Self-contained tomosynthetic, radiographic-imaging system, method and device. US Patent. 1997;5:668-844.
    • (1997)
    • Webber, R.L.1
  • 27
    • 0030621857 scopus 로고    scopus 로고
    • Tuned-aperture computed tomography (TACT-TM): Theory and application for three-dimensional dento-alveolar imaging
    • Webber RL, Horton RA, Tyndall DA, et al. Tuned-aperture computed tomography (TACT-TM): theory and application for three-dimensional dento-alveolar imaging. Dentomaxillofacial Radiol. 1997;26:53-62.
    • (1997) Dentomaxillofacial Radiol , vol.26 , pp. 53-62
    • Webber, R.L.1    Horton, R.A.2    Tyndall, D.A.3
  • 28
    • 0026723137 scopus 로고
    • A multiple projection method for digital tomosynthesis
    • Kolitsi Z, Anastassopoulos V, Scodras A, et al. A multiple projection method for digital tomosynthesis. Med Phys. 1992;19:1045-1050.
    • (1992) Med Phys , vol.19 , pp. 1045-1050
    • Kolitsi, Z.1    Anastassopoulos, V.2    Scodras, A.3
  • 29
    • 0037339682 scopus 로고    scopus 로고
    • Tomographic mammography using a limited number of low-dose cone-beam projection images
    • Wu T, Stewart A, Stanton M, et al. Tomographic mammography using a limited number of low-dose cone-beam projection images. Med Phys. 2003;30:365-380.
    • (2003) Med Phys , vol.30 , pp. 365-380
    • Wu, T.1    Stewart, A.2    Stanton, M.3
  • 31
    • 0012279636 scopus 로고
    • Matrix Inversion Tomosynthesis improvements in longitudinal x-ray slice imaging.
    • US Patent, 4:903-204
    • Dobbins JT III. Matrix Inversion Tomosynthesis improvements in longitudinal x-ray slice imaging. US Patent. 1990;4:903-204.
    • (1990)
    • Dobbins III, J.T.1
  • 32
    • 0033749174 scopus 로고    scopus 로고
    • Applications of Matrix Inverse Tomosynthesis
    • Warp RJ, Godfrey DG, Dobbins JT III. Applications of Matrix Inverse Tomosynthesis. Proc SPIE. 2000;3977:376-383.
    • (2000) Proc SPIE , vol.3977 , pp. 376-383
    • Warp, R.J.1    Godfrey, D.G.2    Dobbins III, J.T.3
  • 33
    • 0034860961 scopus 로고    scopus 로고
    • Optimization of Matrix Inversion Tomosynthesis
    • Godfrey DJ, Warp RJ, Dobbins JT III. Optimization of Matrix Inversion Tomosynthesis. Proc SPIE. 2001;4320:696-704.
    • (2001) Proc SPIE , vol.4320 , pp. 696-704
    • Godfrey, D.J.1    Warp, R.J.2    Dobbins III, J.T.3
  • 34
    • 0042376270 scopus 로고    scopus 로고
    • Practical strategies for the clinical implementation of matrix inversion tomosynthesis (MITS)
    • Godfrey DJ, Rader A, Dobbins JT III. Practical strategies for the clinical implementation of matrix inversion tomosynthesis (MITS). Proc SPIE. 2003;5030:379-390.
    • (2003) Proc SPIE , vol.5030 , pp. 379-390
    • Godfrey, D.J.1    Rader, A.2    Dobbins III, J.T.3
  • 35
    • 0141928682 scopus 로고    scopus 로고
    • Digital x-ray tomosynthesis: Current state of the art and clinical potential
    • Dobbins JT III, Godfrey DJ. Digital x-ray tomosynthesis: current state of the art and clinical potential. Phys Med Biol. 2003;48: R65-R106.
    • (2003) Phys Med Biol , vol.48
    • Dobbins III, J.T.1    Godfrey, D.J.2
  • 36
    • 33644627960 scopus 로고    scopus 로고
    • Optimization of the matrix inversion tomosynthesis (MITS) impulse response and modulation transfer function characteristics for chest imaging
    • Godfrey DJ, McAdams HP, Dobbins JT III. Optimization of the matrix inversion tomosynthesis (MITS) impulse response and modulation transfer function characteristics for chest imaging. Med Phys. 2006;33:655-667.
    • (2006) Med Phys , vol.33 , pp. 655-667
    • Godfrey, D.J.1    McAdams, H.P.2    Dobbins III, J.T.3
  • 37
    • 33745420215 scopus 로고    scopus 로고
    • Chen Y, Lo JY, Baker JA, et al. Gaussian frequency blending algorithm with Matrix Inversion Tomosynthesis (MITS) and Filtered Back Projection (FBP) for better digital breast tomosynthesis reconstruction. Proc SPIE. 2006;6142:0E1-0E9.
    • Chen Y, Lo JY, Baker JA, et al. Gaussian frequency blending algorithm with Matrix Inversion Tomosynthesis (MITS) and Filtered Back Projection (FBP) for better digital breast tomosynthesis reconstruction. Proc SPIE. 2006;6142:0E1-0E9.
  • 38
    • 34748895062 scopus 로고    scopus 로고
    • Methodology of NEQ(f) analysis for optimization and comparison of digital breast tomosynthesis acquisition techniques and reconstruction algorithms
    • Chen Y, Lo JY, Ranger NT, et al. Methodology of NEQ(f) analysis for optimization and comparison of digital breast tomosynthesis acquisition techniques and reconstruction algorithms. Proc SPIE. 2007;6510:111-119.
    • (2007) Proc SPIE , vol.6510 , pp. 111-119
    • Chen, Y.1    Lo, J.Y.2    Ranger, N.T.3
  • 39
    • 33745383814 scopus 로고    scopus 로고
    • Noise power spectrum analysis for several digital breast tomosynthesis reconstruction algorithms
    • Chen Y, Lo JY, Dobbins JT III. Noise power spectrum analysis for several digital breast tomosynthesis reconstruction algorithms. Proc SPIE. 2006;6142:59-1-59-8.
    • (2006) Proc SPIE , vol.6142
    • Chen, Y.1    Lo, J.Y.2    Dobbins III, J.T.3
  • 40
    • 0021186954 scopus 로고
    • Tomosynthesis applied to digital subtraction angiography
    • Kruger RA, Sedaghati M, Roy DG, et al. Tomosynthesis applied to digital subtraction angiography. Radiology. 1984;152:805-808.
    • (1984) Radiology , vol.152 , pp. 805-808
    • Kruger, R.A.1    Sedaghati, M.2    Roy, D.G.3
  • 41
    • 0141872724 scopus 로고
    • Tuned-aperture computed tomography for diagnosis of crestal defects around implants
    • Webber RL, Horton R, Underhil T. Tuned-aperture computed tomography for diagnosis of crestal defects around implants. J Dent Res. 1995;74:18.
    • (1995) J Dent Res , vol.74 , pp. 18
    • Webber, R.L.1    Horton, R.2    Underhil, T.3
  • 42
    • 0040866430 scopus 로고
    • Comparison of TACT with film for detecting osseous jaw lesions
    • Vandre R, Webber R, Horton R, et al. Comparison of TACT with film for detecting osseous jaw lesions. J Dent Res. 1995; 74:18.
    • (1995) J Dent Res , vol.74 , pp. 18
    • Vandre, R.1    Webber, R.2    Horton, R.3
  • 44
    • 0031601933 scopus 로고    scopus 로고
    • Tuned-aperture computed tomography and detection of recurrent caries
    • Nair MK, Tyndall DA, Ludlow JB, et al. Tuned-aperture computed tomography and detection of recurrent caries. Caries Res. 1998; 31:23-31.
    • (1998) Caries Res , vol.31 , pp. 23-31
    • Nair, M.K.1    Tyndall, D.A.2    Ludlow, J.B.3
  • 46
    • 0033625447 scopus 로고    scopus 로고
    • A controlled evaluation of tuned-aperture computed tomography applied to digital spot mammography
    • Webber RL, Underhill HR, Freimanis RI. A controlled evaluation of tuned-aperture computed tomography applied to digital spot mammography. J Digital Imaging. 2000;13:90-97.
    • (2000) J Digital Imaging , vol.13 , pp. 90-97
    • Webber, R.L.1    Underhill, H.R.2    Freimanis, R.I.3
  • 47
    • 0034912334 scopus 로고    scopus 로고
    • Evaluation of linear and nonlinear tomosynthetic reconstruction methods in digital mammography
    • Suryanarayanan S, Karellas A, Vedantham S, et al. Evaluation of linear and nonlinear tomosynthetic reconstruction methods in digital mammography. Acad Radiol. 2001;8:219-224.
    • (2001) Acad Radiol , vol.8 , pp. 219-224
    • Suryanarayanan, S.1    Karellas, A.2    Vedantham, S.3
  • 48
    • 4644334876 scopus 로고    scopus 로고
    • A comparison of reconstruction algorithms for breast tomosynthesis
    • Wu T, Moore RH, Rafferty EA, et al. A comparison of reconstruction algorithms for breast tomosynthesis. Med Phys. 2004;31:2636-2647.
    • (2004) Med Phys , vol.31 , pp. 2636-2647
    • Wu, T.1    Moore, R.H.2    Rafferty, E.A.3
  • 49
    • 23844558650 scopus 로고    scopus 로고
    • Digital tomosynthesis using an amorphous selenium flat panel detector
    • Bissonnette M, Hansroul M, Masson E, et al. Digital tomosynthesis using an amorphous selenium flat panel detector. Proc SPIE. 2005; 5745:529-540.
    • (2005) Proc SPIE , vol.5745 , pp. 529-540
    • Bissonnette, M.1    Hansroul, M.2    Masson, E.3
  • 50
    • 33847676189 scopus 로고    scopus 로고
    • A computer simulation platform for the optimization of a breast tomosynthesis system
    • Zhou J, Zhao B, Zhao W. A computer simulation platform for the optimization of a breast tomosynthesis system. Med Phys. 2007;34: 1098-1109.
    • (2007) Med Phys , vol.34 , pp. 1098-1109
    • Zhou, J.1    Zhao, B.2    Zhao, W.3
  • 51
    • 33746658617 scopus 로고    scopus 로고
    • A comparison of reconstruction algorithms for C-arm mammography tomosynthesis
    • Rakowski JT, Dennis MJ. A comparison of reconstruction algorithms for C-arm mammography tomosynthesis. Med Phys. 2006;33:3018-3032.
    • (2006) Med Phys , vol.33 , pp. 3018-3032
    • Rakowski, J.T.1    Dennis, M.J.2
  • 52
    • 27744556063 scopus 로고    scopus 로고
    • Computer-aided detection system for breast masses on digital tomosynthesis mammograms: Preliminary experience
    • Chan H-P, Wei J, Sahiner B, et al. Computer-aided detection system for breast masses on digital tomosynthesis mammograms: preliminary experience. Radiology. 2005;237:1075-1080.
    • (2005) Radiology , vol.237 , pp. 1075-1080
    • Chan, H.-P.1    Wei, J.2    Sahiner, B.3
  • 53
    • 0037339814 scopus 로고    scopus 로고
    • Digital tomosynthesis of hand joints for arthritis assessment
    • Duryea J, Dobbins JT III, Lynch JA. Digital tomosynthesis of hand joints for arthritis assessment. Med Phys. 2003;30:325-333.
    • (2003) Med Phys , vol.30 , pp. 325-333
    • Duryea, J.1    Dobbins III, J.T.2    Lynch, J.A.3
  • 54
    • 0029948077 scopus 로고    scopus 로고
    • Digital tomosynthesis imaging of the lung
    • Sone S, Kasuga T, Sakai F, et al. Digital tomosynthesis imaging of the lung. Radiat Med. 1996;14:53-63.
    • (1996) Radiat Med , vol.14 , pp. 53-63
    • Sone, S.1    Kasuga, T.2    Sakai, F.3
  • 55
    • 0021489255 scopus 로고
    • Restoration of digital multiplane tomosynthesis by a constrained iteration method
    • Ruttimann UE, Groenhuis RAJ, Webber RL. Restoration of digital multiplane tomosynthesis by a constrained iteration method. IEEE Trans Med Imaging. 1984;3:141-148.
    • (1984) IEEE Trans Med Imaging , vol.3 , pp. 141-148
    • Ruttimann, U.E.1    Groenhuis, R.A.J.2    Webber, R.L.3
  • 56
    • 0005642443 scopus 로고    scopus 로고
    • A theoretical framework for filtered backprojection in tomosynthesis
    • Lauritsch G, Harer WH. A theoretical framework for filtered backprojection in tomosynthesis. Proc SPIE. 1998;3338:1127-1137.
    • (1998) Proc SPIE , vol.3338 , pp. 1127-1137
    • Lauritsch, G.1    Harer, W.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.