Volumn 202, Issue 2, 1997, Pages 453-457

Simulated dose reduction in conventional chest CT: Validation study

Author keywords

Computed tomography (CT), comparative studies; Computed tomography (CT), image quality; Computed tomography (CT), technology; Radiations, exposure to patients and personnel

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER SIMULATION; DIAGNOSTIC ACCURACY; DOSIMETRY; FEMALE; HUMAN; HUMAN CELL; HUMAN TISSUE; IMAGE QUALITY; IMAGE RECONSTRUCTION; MALE; OBSERVER VARIATION; PRIORITY JOURNAL; RADIATION DOSE; RADIATION EXPOSURE; THORAX SCINTISCANNING;

EID: 0031023761     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiology.202.2.9015073     Document Type: Article
Times cited : (113)

References (11)
  • 2
    • 0027415118 scopus 로고
    • Is chest CT performed too often?
    • DiMarco AF, Briones B. Is chest CT performed too often? Chest 1993; 103:985-986.
    • (1993) Chest , vol.103 , pp. 985-986
    • DiMarco, A.F.1    Briones, B.2
  • 4
    • 0027964387 scopus 로고
    • In search of the appropriate use of chest computed tomography
    • DiMarco AF, Renston JP. In search of the appropriate use of chest computed tomography. Chest 1994; 106:332-333.
    • (1994) Chest , vol.106 , pp. 332-333
    • DiMarco, A.F.1    Renston, J.P.2
  • 5
    • 0025958376 scopus 로고
    • Determinations of organ doses and effective dose equivalents from computed tomographic examination
    • Nishizawa K, Maruyama T, Takayama M, Okada M, Hachiya J, Furuya Y. Determinations of organ doses and effective dose equivalents from computed tomographic examination. Br J Radiol 1991; 64:20-28.
    • (1991) Br J Radiol , vol.64 , pp. 20-28
    • Nishizawa, K.1    Maruyama, T.2    Takayama, M.3    Okada, M.4    Hachiya, J.5    Furuya, Y.6
  • 7
    • 0028939173 scopus 로고
    • CT of the chest: Minimal tube current required for good image quality with the least radiation dose
    • Mayo JR, Hartman TE, Lee KS, Primack SL, Vedal S, Müller NL. CT of the chest: minimal tube current required for good image quality with the least radiation dose. AJR 1995; 164:603-607.
    • (1995) AJR , vol.164 , pp. 603-607
    • Mayo, J.R.1    Hartman, T.E.2    Lee, K.S.3    Primack, S.L.4    Vedal, S.5    Müller, N.L.6
  • 8
    • 23444451272 scopus 로고
    • Chronic infiltrative lung disease: Comparison of diagnostic accuracies of radiography and low- and conventional-dose thin-section CT
    • Lee KS, Primack SL, Staples CA, Mayo JR, Aldrich JE, Müller NL. Chronic infiltrative lung disease: comparison of diagnostic accuracies of radiography and low- and conventional-dose thin-section CT. Radiology 1994; 191:669-673.
    • (1994) Radiology , vol.191 , pp. 669-673
    • Lee, K.S.1    Primack, S.L.2    Staples, C.A.3    Mayo, J.R.4    Aldrich, J.E.5    Müller, N.L.6
  • 10
    • 0019364103 scopus 로고
    • The effect of mAs variation upon computed tomography image quality as evaluated by in vivo and in vitro studies
    • Haaga JR, Miraldi F, MacIntyre W, LiPuma JP, Bryan PJ, Wiesen E. The effect of mAs variation upon computed tomography image quality as evaluated by in vivo and in vitro studies. Radiology 1981; 138:449-454.
    • (1981) Radiology , vol.138 , pp. 449-454
    • Haaga, J.R.1    Miraldi, F.2    MacIntyre, W.3    LiPuma, J.P.4    Bryan, P.J.5    Wiesen, E.6
  • 11
    • 0012749394 scopus 로고
    • Computed tomography: Instrumentation
    • Bronzino JE, ed. Boca Raton, Fla: CRC Press
    • Cunningham IA. Computed tomography: instrumentation. In: Bronzino JE, ed. The biomedical engineering handbook. Boca Raton, Fla: CRC Press, 1995; 990-1002.
    • (1995) The Biomedical Engineering Handbook , pp. 990-1002
    • Cunningham, I.A.1