메뉴 건너뛰기




Volumn 54, Issue 24, 2009, Pages 7329-7344

A virtual source model of electron contamination of a therapeutic photon beam

Author keywords

[No Author keywords available]

Indexed keywords

AIR TRANSPORT; ANGULAR DEPENDENCE; DOSE CALCULATION; DOSE DISTRIBUTIONS; ELECTRON CONTAMINATION; ELECTRON DOSE; ENERGETIC PROPERTIES; ENERGY DEPENDENT; FIELD SIZE; FLATTENING FILTERS; GAUSSIAN SOURCES; MC SIMULATION; MEAN ENERGY; MONTE CARLO; PARTICLE FLUENCE; PARTICLE GENERATION; PATIENT GEOMETRIES; PHOTON BEAMS; PHOTON SOURCES; PRIMARY PHOTONS; SEGMENT SHAPE; SURFACE DOSE; TREATMENT PLANNING SYSTEMS; TUNABLE PARAMETER; VIRTUAL SOURCES;

EID: 71949090903     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/54/24/006     Document Type: Article
Times cited : (35)

References (28)
  • 1
    • 0242606142 scopus 로고    scopus 로고
    • A revision of the gamma-evaluation concept for the comparison of dose distributions
    • Bakai Annemarie, Alber Markus and Nüsslin Fridtjof 2003 A revision of the gamma-evaluation concept for the comparison of dose distributions Phys. Med. Biol. 48 3543-53
    • (2003) Phys. Med. Biol. , vol.48 , Issue.21 , pp. 3543-3553
    • Bakai Annemarie, A.1
  • 2
    • 0033962673 scopus 로고    scopus 로고
    • Photon beam characterization and modelling for Monte Carlo treatment planning
    • DOI 10.1088/0031-9155/45/2/311, PII S0031915500083482
    • Deng Jun, Jiang Steve B, Kapur Ajay, Jinsheng Li, Pawlicki Todd and Ma C-M 2000 Photon beam characterization and modelling for Monte Carlo treatment planning Phys. Med. Biol. 45 411-27 (Pubitemid 30096772)
    • (2000) Physics in Medicine and Biology , vol.45 , Issue.2 , pp. 411-427
    • Deng, J.1    Jiang, S.B.2    Kapur, A.3    Li, J.4    Pawlicki, T.5    Ma, C.-M.6
  • 3
    • 0037035317 scopus 로고    scopus 로고
    • Energy spectra, angular spread, fluence profiles and dose distributions of 6 and 18 MV photon beams: Results of Monte Carlo simulations for a Varian 2100EX accelerator
    • Ding George X 2002 Energy spectra, angular spread, fluence profiles and dose distributions of 6 and 18 MV photon beams: results of Monte Carlo simulations for a Varian 2100EX accelerator Phys. Med. Biol. 47 1025-46
    • (2002) Phys. Med. Biol. , vol.47 , Issue.7 , pp. 1025-1046
    • Ding George, X.1
  • 5
    • 0032772588 scopus 로고    scopus 로고
    • Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm
    • Fippel M 1999 Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm Med. Phys. 26 1466-75
    • (1999) Med. Phys. , vol.26 , Issue.8 , pp. 1466-1475
    • Fippel, M.1
  • 6
    • 0037340926 scopus 로고    scopus 로고
    • A virtual photon energy fluence model for Monte Carlo dose calculation
    • Fippel Matthias, Haryanto Freddy, Dohm Oliver, Nusslin Fridtjof and Kriesen Stephan 2003 A virtual photon energy fluence model for Monte Carlo dose calculation Med. Phys. 30 301-11
    • (2003) Med. Phys. , vol.30 , Issue.3 , pp. 301-311
    • Matthias, F.1    Freddy, H.2    Oliver, D.3    Fridtjof, N.4    Stephan, K.5
  • 7
    • 0035003832 scopus 로고    scopus 로고
    • A multiple source model for 6 MV photon beam dose calculations using Monte Carlo
    • Fix Michael K, Stampanoni Marco, Manser Peter, Born Ernst J, Mini Roberto and Rüegsegger Peter 2001 A multiple source model for 6 MV photon beam dose calculations using Monte Carlo Phys. Med. Biol. 46 1407-27
    • (2001) Phys. Med. Biol. , vol.46 , Issue.5 , pp. 1407-1427
    • Fix Michael, K.1    Marco, S.2    Peter, M.3    Born Ernst, J.4    Roberto, M.5    Peter, R.6
  • 8
    • 67651214053 scopus 로고    scopus 로고
    • Skin dose impact from vacuum immobilization device and carbon fiber couch in intensity modulated radiation therapy for prostate cancer
    • Lee Kuo-Wei, Jian-Kuen Wu, Jeng Shiu-Chen, Liu Yen-Wan Hsueh and Cheng Jason Chia-Hsien 2009 Skin dose impact from vacuum immobilization device and carbon fiber couch in intensity modulated radiation therapy for prostate cancer Med. Dosim. 34 228-32
    • (2009) Med. Dosim. , vol.34 , Issue.3 , pp. 228-232
    • Lee, K.-W.1    Wu, J.-K.2    Jeng, S.-C.3    Hsueh Liu, Y.-W.4    Cheng Jason, C.-H.5
  • 9
    • 0032930701 scopus 로고    scopus 로고
    • An MCNP-based model of a linear accelerator x-ray beam
    • Lewis R D, Ryde S J, Hancock D A and Evans C J 1999 An MCNP-based model of a linear accelerator x-ray beam Phys. Med. Biol. 44 1219-30
    • (1999) Phys. Med. Biol. , vol.44 , Issue.5 , pp. 1219-1230
    • Lewis, R.D.1    Ryde, S.J.2    Hancock, D.A.3    Evans, C.J.4
  • 10
    • 0020037703 scopus 로고
    • Magnetic analysis of the radiation components of a 10 MV photon beam
    • Ling C C, Schell M C and Rustgi S N 1982 Magnetic analysis of the radiation components of a 10 MV photon beam Med. Phys. 9 20-6
    • (1982) Med. Phys. , vol.9 , Issue.1 , pp. 20-26
    • Ling, C.C.1    Schell, M.C.2    Rustgi, S.N.3
  • 11
    • 0346463220 scopus 로고    scopus 로고
    • Comparison between TG-51 and TRS-398: Electron contamination effect on photon beam-quality specification
    • Lopez Medina Antonio, Teijeiro Antonio, Salvador Francisco, Medal Daniela, Vazquez Julio, Salgado Manuel and Carrion María C 2004 Comparison between TG-51 and TRS-398: electron contamination effect on photon beam-quality specification Phys. Med. Biol. 49 17-32
    • (2004) Phys. Med. Biol. , vol.49 , Issue.1 , pp. 17-32
    • Antonio, L.M.1    Antonio, T.2    Francisco, S.3    Daniela, M.4    Julio, V.5    Manuel, S.6    María, C.7
  • 13
    • 0030945205 scopus 로고    scopus 로고
    • Accurate characterization of Monte Carlo calculated electron beams for radiotherapy
    • Ma C M, Faddegon B A, Rogers D W and Mackie T R 1997 Accurate characterization of Monte Carlo calculated electron beams for radiotherapy Med. Phys. 24 401-16
    • (1997) Med. Phys. , vol.24 , Issue.3 , pp. 401-416
    • Ma, C.M.1    Faddegon, B.A.2    Rogers, D.W.3    MacKie, T.R.4
  • 15
    • 0020673989 scopus 로고
    • Investigation of buildup dose from electron contamination of clinical photon beams
    • Petti P L, Goodman M S, Gabriel T A and Mohan R 1983a Investigation of buildup dose from electron contamination of clinical photon beams Med. Phys. 10 18-24
    • (1983) Med. Phys. , vol.10 , Issue.1 , pp. 18-24
    • Petti, P.L.1    Goodman, M.S.2    Gabriel, T.A.3    Mohan, R.4
  • 17
    • 0032941896 scopus 로고    scopus 로고
    • Correcting for electron contamination at dose maximum in photon beams
    • Rogers D W 1999 Correcting for electron contamination at dose maximum in photon beams Med. Phys. 26 533-7
    • (1999) Med. Phys. , vol.26 , Issue.4 , pp. 533-537
    • Rogers, D.W.1
  • 21
    • 0036130665 scopus 로고    scopus 로고
    • Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code
    • Sheikh-Bagheri Daryoush and Rogers D W O 2002 Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code Med. Phys. 29 391-402
    • (2002) Med. Phys. , vol.29 , Issue.3 , pp. 391-402
    • Daryoush, S.1    Rogers, D.W.O.2
  • 22
    • 34547099077 scopus 로고    scopus 로고
    • A virtual photon source model of an Elekta linear accelerator with integrated mini MLC for Monte Carlo based IMRT dose calculation
    • Sikora M, Dohm O and Alber M 2007 A virtual photon source model of an Elekta linear accelerator with integrated mini MLC for Monte Carlo based IMRT dose calculation Phys. Med. Biol. 52 4449-63
    • (2007) Phys. Med. Biol. , vol.52 , Issue.15 , pp. 4449-4463
    • Sikora, M.1    Dohm, O.2    Alber, M.3
  • 23
    • 0029845005 scopus 로고    scopus 로고
    • Electron contamination in clinical high energy photon beams
    • Sjögren R and Karlsson M 1996 Electron contamination in clinical high energy photon beams Med. Phys. 23 1873-81
    • (1996) Med. Phys. , vol.23 , Issue.11 , pp. 1873-1881
    • Sjögren, R.1    Karlsson, M.2
  • 24
    • 34247211685 scopus 로고    scopus 로고
    • Determination of parameters for a multiple-source model of megavoltage photon beams using optimization methods
    • Tillikainen L, Siljamäki S, Helminen H, Alakuijala J and Pyyry J 2007 Determination of parameters for a multiple-source model of megavoltage photon beams using optimization methods Phys. Med. Biol. 52 1441-67
    • (2007) Phys. Med. Biol. , vol.52 , Issue.5 , pp. 1441-1467
    • Tillikainen, L.1    Siljamäki, S.2    Helminen, H.3    Alakuijala, J.4    Pyyry, J.5
  • 25
    • 0242521407 scopus 로고    scopus 로고
    • Monte Carlo modelling of external radiotherapy photon beams
    • Verhaegen Frank and Seuntjens Jan 2003 Monte Carlo modelling of external radiotherapy photon beams Phys. Med. Biol. 48 R107-64
    • (2003) Phys. Med. Biol. , vol.48 , Issue.21
    • Frank, V.1    Jan, S.2
  • 27
    • 0031858002 scopus 로고    scopus 로고
    • A patient-specific Monte Carlo dose-calculation method for photon beams
    • Wang L, Chui C S and Lovelock M 1998 A patient-specific Monte Carlo dose-calculation method for photon beams Med. Phys. 25 867-78
    • (1998) Med. Phys. , vol.25 , Issue.6 , pp. 867-878
    • Wang, L.1    Chui, C.S.2    Lovelock, M.3
  • 28
    • 3242793600 scopus 로고    scopus 로고
    • Modelling of electron contamination in clinical photon beams for Monte Carlo dose calculation
    • Yang J, Li J S, Qin L, Xiong W and Ma C-M 2004 Modelling of electron contamination in clinical photon beams for Monte Carlo dose calculation Phys. Med. Biol. 49 2657-73
    • (2004) Phys. Med. Biol. , vol.49 , Issue.12 , pp. 2657-2673
    • Yang, J.1    Li, J.S.2    Qin, L.3    Xiong, W.4    Ma, C.-M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.