메뉴 건너뛰기




Volumn 48, Issue 11, 2002, Pages 2023-2029

Wrong biochemistry results: Two case reports and observational study in 5310 patients on potentially misleading thyroid-stimulating hormone and gonadotropin immunoassay results

Author keywords

[No Author keywords available]

Indexed keywords

GONADOTROPIN; THYROTROPIN;

EID: 0036840561     PISSN: 00099147     EISSN: None     Source Type: Journal    
DOI: 10.1093/clinchem/48.11.2023     Document Type: Article
Times cited : (126)

References (21)
  • 1
    • 0033885801 scopus 로고    scopus 로고
    • Interference in immunoassays - Still a threat
    • Kricka LJ. Interference in immunoassays - Still a threat. Clin Chem 2000;46:1037-8.
    • (2000) Clin Chem , vol.46 , pp. 1037-1038
    • Kricka, L.J.1
  • 2
    • 0035968565 scopus 로고    scopus 로고
    • Wrong biochemistry results
    • Ismail AAA, Barth JH. Wrong biochemistry results. BMJ 2001;323:705-6.
    • (2001) BMJ , vol.323 , pp. 705-706
    • Ismail, A.A.A.1    Barth, J.H.2
  • 3
    • 0032814344 scopus 로고    scopus 로고
    • Human anti-animal antibody interference in immunological assays
    • Kricka LJ. Human anti-animal antibody interference in immunological assays. Clin Chem 1999;45:942-56.
    • (1999) Clin Chem , vol.45 , pp. 942-956
    • Kricka, L.J.1
  • 5
    • 0033869592 scopus 로고    scopus 로고
    • An IgM λ antibody to Escherichia coli produces false positive results in multiple immunometric assays
    • Covinsky M, Laterza O, Pfeifer JD, Farkas-Stallosi T, Scott MG. An IgM λ antibody to Escherichia coli produces false positive results in multiple immunometric assays. Clin Chem 2000;46:1157-61.
    • (2000) Clin Chem , vol.46 , pp. 1157-1161
    • Covinsky, M.1    Laterza, O.2    Pfeifer, J.D.3    Farkas-Stallosi, T.4    Scott, M.G.5
  • 7
    • 0031911110 scopus 로고    scopus 로고
    • Antibody interference in thyroid assays: A potential for clinical misinformation
    • Després N, Grant AM. Antibody interference in thyroid assays: A potential for clinical misinformation. Clin Chem 1998;44:440-54.
    • (1998) Clin Chem , vol.44 , pp. 440-454
    • Després, N.1    Grant, A.M.2
  • 8
    • 0028952513 scopus 로고
    • Reducing interference from heterophilic antibodies in a two-site immunoassay for carcinoembryonic antigen (CEA) by using human/mouse chimeric antibody to CEA as the tracer
    • Kuroki M, Matsumoto Y, Arakawa F, Haruno M, Murakami M, Kuwahara M, et al. Reducing interference from heterophilic antibodies in a two-site immunoassay for carcinoembryonic antigen (CEA) by using human/mouse chimeric antibody to CEA as the tracer. J Immunol Methods 1995;180:81-91.
    • (1995) J Immunol Methods , vol.180 , pp. 81-91
    • Kuroki, M.1    Matsumoto, Y.2    Arakawa, F.3    Haruno, M.4    Murakami, M.5    Kuwahara, M.6
  • 9
    • 0030765913 scopus 로고    scopus 로고
    • Heterophilic antibodies remain a problem for the immunoassay laboratory
    • Ward G, McKinnon L, Badrick T, Hickman PE. Heterophilic antibodies remain a problem for the immunoassay laboratory. Am J Clin Pathol 1997;108:417-21.
    • (1997) Am J Clin Pathol , vol.108 , pp. 417-421
    • Ward, G.1    McKinnon, L.2    Badrick, T.3    Hickman, P.E.4
  • 10
    • 0000004140 scopus 로고
    • Measurement in medicine; the analysis of method comparison studies
    • Altman DG, Bland JM. Measurement in medicine; the analysis of method comparison studies. Statistician 1983;32:307-17.
    • (1983) Statistician , vol.32 , pp. 307-317
    • Altman, D.G.1    Bland, J.M.2
  • 11
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 12
    • 0025346127 scopus 로고
    • Heterophilic antibodies in human sera causing falsely increased results in the CA 125 immunofluorometric assay
    • Boerman OC, Segers MFG, Poels LG, Kenemans P, Thomas CMG. Heterophilic antibodies in human sera causing falsely increased results in the CA 125 immunofluorometric assay. Clin Chem 1990;36:888-91.
    • (1990) Clin Chem , vol.36 , pp. 888-891
    • Boerman, O.C.1    Segers, M.F.G.2    Poels, L.G.3    Kenemans, P.4    Thomas, C.M.G.5
  • 13
    • 0033032667 scopus 로고    scopus 로고
    • False-positive hCG assay results leading to unnecessary surgery and chemotherapy and needless occurrences of diabetes and coma
    • Cole LA, Rinne KM, Shahabi S, Omrani A. False-positive hCG assay results leading to unnecessary surgery and chemotherapy and needless occurrences of diabetes and coma. Clin Chem 1999;45:313-4.
    • (1999) Clin Chem , vol.45 , pp. 313-314
    • Cole, L.A.1    Rinne, K.M.2    Shahabi, S.3    Omrani, A.4
  • 14
    • 0036191429 scopus 로고    scopus 로고
    • Falsely increased prostatic-specific antigen concentrations attributed to heterophilic antibodies
    • Camacho T, Mora J, Segura A, Guitian J, Lema F, Bandih J, et al. Falsely increased prostatic-specific antigen concentrations attributed to heterophilic antibodies. Ann Clin Biochem 2002;39:160-1.
    • (2002) Ann Clin Biochem , vol.39 , pp. 160-161
    • Camacho, T.1    Mora, J.2    Segura, A.3    Guitian, J.4    Lema, F.5    Bandih, J.6
  • 16
    • 0030330910 scopus 로고    scopus 로고
    • False-negative immunoassay results for cardiac troponin I probably due to circulating troponin I autoantibodies
    • Bohner J, von Pape KW, Hannes W, Stegmann T. False-negative immunoassay results for cardiac troponin I probably due to circulating troponin I autoantibodies. Clin Chem 1996;42:2046.
    • (1996) Clin Chem , vol.42 , pp. 2046
    • Bohner, J.1    Von Pape, K.W.2    Hannes, W.3    Stegmann, T.4
  • 17
    • 0032742968 scopus 로고    scopus 로고
    • High percentage of false positive cardiac troponin I results in patients with rheumatoid factor
    • Krahn J, Parry DM, Laroux M, Dalton J. High percentage of false positive cardiac troponin I results in patients with rheumatoid factor. Clin Biochem 1999;32:477-80.
    • (1999) Clin Biochem , vol.32 , pp. 477-480
    • Krahn, J.1    Parry, D.M.2    Laroux, M.3    Dalton, J.4
  • 19
    • 0033248168 scopus 로고    scopus 로고
    • False-positive troponin I in the MEIA due to the presence of rheumatoid factor in serum. Elimination of this interference by using a polyclonal antisera against rheumatoid factor
    • Dasgupta A, Banerjee SK, Datta P. False-positive troponin I in the MEIA due to the presence of rheumatoid factor in serum. Elimination of this interference by using a polyclonal antisera against rheumatoid factor. Am J Clin Pathol 1999;112:753-6.
    • (1999) Am J Clin Pathol , vol.112 , pp. 753-756
    • Dasgupta, A.1    Banerjee, S.K.2    Datta, P.3
  • 20
    • 0033403026 scopus 로고    scopus 로고
    • False positive analytical interference of cardiac troponin I assays: An important consideration for method selection
    • Parry DM, Krahn J, Leroux M, Dalton J. False positive analytical interference of cardiac troponin I assays: An important consideration for method selection. Clin Biochem 1999;32:667-9.
    • (1999) Clin Biochem , vol.32 , pp. 667-669
    • Parry, D.M.1    Krahn, J.2    Leroux, M.3    Dalton, J.4
  • 21
    • 0036139229 scopus 로고    scopus 로고
    • Heterophilic antibody interference with cardiac T quantitative rapid assay
    • White GH, Tideman PA Heterophilic antibody interference with cardiac T quantitative rapid assay. Clin Chem 2002;48:201-2.
    • (2002) Clin Chem , vol.48 , pp. 201-202
    • White, G.H.1    Tideman, P.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.