메뉴 건너뛰기




Volumn 125, Issue 5, 2004, Pages 1877-1884

Common causes of troponin elevations in the absence of acute myocardial infarction: Incidence and clinical significance

Author keywords

False positive; Heart failure; Pericarditis; Pulmonary embolism; Sepsis; Troponin

Indexed keywords

BIOLOGICAL MARKER; FIBRIN; RHEUMATOID FACTOR; TROPONIN; TROPONIN I; TROPONIN T;

EID: 2442438574     PISSN: 00123692     EISSN: None     Source Type: Journal    
DOI: 10.1378/chest.125.5.1877     Document Type: Review
Times cited : (208)

References (57)
  • 1
    • 0034641661 scopus 로고    scopus 로고
    • It's time for a change to a troponin standard
    • A Jaffe AS, Ravkilde J, Roberts R, et al. It's time for a change to a troponin standard. Circulation 2000; 102:1216-1220
    • (2000) Circulation , vol.102 , pp. 1216-1220
    • A Jaffe, A.S.1    Ravkilde, J.2    Roberts, R.3
  • 2
    • 6744240314 scopus 로고    scopus 로고
    • Cardiac-specific troponin I levels to predict the risk of mortality in patients with acute coronary syndromes
    • Antman EM, Tanasijevic MJ, Thompson B, et al. Cardiac-specific troponin I levels to predict the risk of mortality in patients with acute coronary syndromes. N Engl J Med 1996; 335:1342-1349
    • (1996) N Engl J Med , vol.335 , pp. 1342-1349
    • Antman, E.M.1    Tanasijevic, M.J.2    Thompson, B.3
  • 3
    • 0033851515 scopus 로고    scopus 로고
    • Myocardial infarction redefined: A consensus document of the Joint European Society of Cardiology/American College of Cardiology Committee for the redefinition of myocardial infarction
    • Myocardial infarction redefined: a consensus document of the Joint European Society of Cardiology/American College of Cardiology Committee for the redefinition of myocardial infarction. J Am Coll Cardiol 2000; 36:959-969
    • (2000) J Am Coll Cardiol , vol.36 , pp. 959-969
  • 4
    • 0037094123 scopus 로고    scopus 로고
    • False-positive cardiac troponin I in a routine clinical population
    • Fleming SM, O'Byrne L, Finn J, et al. False-positive cardiac troponin I in a routine clinical population. Am J Cardiol 2002; 89:1212-1215
    • (2002) Am J Cardiol , vol.89 , pp. 1212-1215
    • Fleming, S.M.1    O'Byrne, L.2    Finn, J.3
  • 5
    • 18444375563 scopus 로고    scopus 로고
    • Performance of a revised cardiac troponin method that minimizes interference's from heterophilic antibodies
    • Kim WJ, Laterza OF, Hock KG, et al. Performance of a revised cardiac troponin method that minimizes interference's from heterophilic antibodies. Clin Chem 2002; 48: 1028-1034
    • (2002) Clin Chem , vol.48 , pp. 1028-1034
    • Kim, W.J.1    Laterza, O.F.2    Hock, K.G.3
  • 6
    • 0022606648 scopus 로고
    • Acute pericarditis: Myocardial enzyme release as evidence for myocarditis
    • Karjalainen J, Heikkila J. Acute pericarditis: myocardial enzyme release as evidence for myocarditis. Am Heart J 1986; 111:546-552
    • (1986) Am Heart J , vol.111 , pp. 546-552
    • Karjalainen, J.1    Heikkila, J.2
  • 7
    • 0035371463 scopus 로고    scopus 로고
    • Circulating cardiac troponin I in acute pericarditis
    • Brandt RR, Filzmanier K, Hanrath P. Circulating cardiac troponin I in acute pericarditis. Am J Cardiol 2001; 81:1326-1328
    • (2001) Am J Cardiol , vol.81 , pp. 1326-1328
    • Brandt, R.R.1    Filzmanier, K.2    Hanrath, P.3
  • 8
    • 0034010495 scopus 로고    scopus 로고
    • Serum cardiac troponin I and ST-segment elevation in patients with acute pericarditis
    • Bonnefoy E, Gordon P, Kirkorian G, et al. Serum cardiac troponin I and ST-segment elevation in patients with acute pericarditis. Eur Heart J 2000; 21:832-836
    • (2000) Eur Heart J , vol.21 , pp. 832-836
    • Bonnefoy, E.1    Gordon, P.2    Kirkorian, G.3
  • 9
    • 0033599765 scopus 로고    scopus 로고
    • Acute pulmonary embolism: Clinical outcomes in the International Cooperative Pulmonary Embolism Registry (ICOPER)
    • Goldhaber SZ, Visani L, De Rosa M, for ICOPER. Acute pulmonary embolism: clinical outcomes in the International Cooperative Pulmonary Embolism Registry (ICOPER). Lancet 1999; 353:1386-1389
    • (1999) Lancet , vol.353 , pp. 1386-1389
    • Goldhaber, S.Z.1    Visani, L.2    De Rosa, M.3
  • 10
    • 2442594269 scopus 로고    scopus 로고
    • Echocardiography Doppler in pulmonary embolism: Right ventricular dysfunction as a predictor of mortality
    • Ribeiro A, Lindmarker P, Juhlin-Dannfelt A, et al. Echocardiography Doppler in pulmonary embolism: right ventricular dysfunction as a predictor of mortality. Am Heart J 1997; 95:67-68
    • (1997) Am Heart J , vol.95 , pp. 67-68
    • Ribeiro, A.1    Lindmarker, P.2    Juhlin-Dannfelt, A.3
  • 11
    • 0023919043 scopus 로고
    • Acute right ventricular infarction secondary to a massive pulmonary thromboembolism
    • Como-Canella I, Gamello C, Martinez-Onsurbe O, et al. Acute right ventricular infarction secondary to a massive pulmonary thromboembolism. Eur Heart J 1988; 9:534-540
    • (1988) Eur Heart J , vol.9 , pp. 534-540
    • Como-Canella, I.1    Gamello, C.2    Martinez-Onsurbe, O.3
  • 12
    • 2042473591 scopus 로고
    • Elevation of CK-MB following pulmonary embolism: A manifestation of occult right ventricular infarction
    • Adams JE III, Seigel BA, Goldstein JA, et al. Elevation of CK-MB following pulmonary embolism: a manifestation of occult right ventricular infarction [letter]. Chest 1994; 105: 1617
    • (1994) Chest , vol.105 , pp. 1617
    • Adams III, J.E.1    Seigel, B.A.2    Goldstein, J.A.3
  • 13
    • 0343517175 scopus 로고    scopus 로고
    • Independent prognostic value of cardiac troponin T in patients with confirmed pulmonary embolism
    • Giannitis E, Muller-Bardorff M, Volkhard K, et al. Independent prognostic value of cardiac troponin T in patients with confirmed pulmonary embolism. Circulation 2000; 102:211-217
    • (2000) Circulation , vol.102 , pp. 211-217
    • Giannitis, E.1    Muller-Bardorff, M.2    Volkhard, K.3
  • 15
    • 0037074178 scopus 로고    scopus 로고
    • Elevated cardiac troponin levels in patients with subacute pulmonary embolism
    • Douketis JD, Crowther MA, Stanton EB, et al. Elevated cardiac troponin levels in patients with subacute pulmonary embolism. Arch Intern Med 2002; 162:79-81
    • (2002) Arch Intern Med , vol.162 , pp. 79-81
    • Douketis, J.D.1    Crowther, M.A.2    Stanton, E.B.3
  • 16
    • 0025019289 scopus 로고
    • Painless myocardial infarction in the elderly
    • Muller R, Gould L, Betzu R, et al. Painless myocardial infarction in the elderly. Am Heart J 1990; 119:202-204
    • (1990) Am Heart J , vol.119 , pp. 202-204
    • Muller, R.1    Gould, L.2    Betzu, R.3
  • 17
    • 0030723975 scopus 로고    scopus 로고
    • Circulating cardiac troponin I in severe congestive heart failure
    • Missov E, Calzolari C, Pau B. Circulating cardiac troponin I in severe congestive heart failure. Circulation 1997; 96:2953-2958
    • (1997) Circulation , vol.96 , pp. 2953-2958
    • Missov, E.1    Calzolari, C.2    Pau, B.3
  • 18
    • 0031195005 scopus 로고    scopus 로고
    • Detectable serum troponin I in patients with heart failure nonmyocardial ischemic origin
    • La Vecchia L, Mezzena G, Ometto R, et al. Detectable serum troponin I in patients with heart failure nonmyocardial ischemic origin. Am J Cardiol 1997; 80:88-90
    • (1997) Am J Cardiol , vol.80 , pp. 88-90
    • La Vecchia, L.1    Mezzena, G.2    Ometto, R.3
  • 19
    • 0032807452 scopus 로고    scopus 로고
    • A novel biochemical approach to congestive heart failure: Cardiac troponin T
    • Missov E, Mair J. A novel biochemical approach to congestive heart failure: cardiac troponin T. Am Heart J 1999; 138:95-99
    • (1999) Am Heart J , vol.138 , pp. 95-99
    • Missov, E.1    Mair, J.2
  • 20
    • 0032842145 scopus 로고    scopus 로고
    • Clinical significance of elevated levels of cardiac troponin T in patients with chronic heart failure
    • Setsuda K, Seino Y, Takahashi N, et al. Clinical significance of elevated levels of cardiac troponin T in patients with chronic heart failure. Am J Cardiol 1999; 84:608-611
    • (1999) Am J Cardiol , vol.84 , pp. 608-611
    • Setsuda, K.1    Seino, Y.2    Takahashi, N.3
  • 21
    • 0036271468 scopus 로고    scopus 로고
    • Cardiac troponin T levels are associated with poor short- and long-term prognosis in patients with acute cardiogenic pulmonary edema
    • Perna ER, Macin SM, Parras JI, et al. Cardiac troponin T levels are associated with poor short- and long-term prognosis in patients with acute cardiogenic pulmonary edema. Am Heart J 2002; 143:814-820
    • (2002) Am Heart J , vol.143 , pp. 814-820
    • Perna, E.R.1    Macin, S.M.2    Parras, J.I.3
  • 22
    • 0342902201 scopus 로고    scopus 로고
    • Cardiac troponin I levels in patients with left heart failure and cor pulmonale
    • Guler N, Bilge M, Eryonucu B, et al. Cardiac troponin I levels in patients with left heart failure and cor pulmonale. Angiology 2001; 52:317-322
    • (2001) Angiology , vol.52 , pp. 317-322
    • Guler, N.1    Bilge, M.2    Eryonucu, B.3
  • 23
    • 0023214007 scopus 로고
    • Cardiac-specific troponin-I radioimmunoassay in the diagnosis of acute myocardial infarction
    • Cummins B, Auckland ML, Cummins P. Cardiac-specific troponin-I radioimmunoassay in the diagnosis of acute myocardial infarction. Am Heart J 1987; 113:1333-1344
    • (1987) Am Heart J , vol.113 , pp. 1333-1344
    • Cummins, B.1    Auckland, M.L.2    Cummins, P.3
  • 24
    • 0031025578 scopus 로고    scopus 로고
    • Elevations of cardiac troponin I associated with myocarditis, experimental and clinical correlates
    • Smith SC, Ladenson JH, Mason JW, et al. Elevations of cardiac troponin I associated with myocarditis, experimental and clinical correlates. Circulation 1997; 95:163-168
    • (1997) Circulation , vol.95 , pp. 163-168
    • Smith, S.C.1    Ladenson, J.H.2    Mason, J.W.3
  • 25
    • 0034919866 scopus 로고    scopus 로고
    • Elevation of troponin I in sepsis and septic shock
    • Ammann P, Fehr T, Minder EI, et al. Elevation of troponin I in sepsis and septic shock. Intensive Care Med 2001; 27:965-969
    • (2001) Intensive Care Med , vol.27 , pp. 965-969
    • Ammann, P.1    Fehr, T.2    Minder, E.I.3
  • 26
    • 0034078373 scopus 로고    scopus 로고
    • Cardiac troponins I and T are biological markers of left ventricular dysfunction in septic shock
    • ver Elst KM, Spapen HD, Nguyen DN, et al. Cardiac troponins I and T are biological markers of left ventricular dysfunction in septic shock. Clin Chem 2000; 46:650-657
    • (2000) Clin Chem , vol.46 , pp. 650-657
    • Ver Elst, K.M.1    Spapen, H.D.2    Nguyen, D.N.3
  • 27
    • 0034069083 scopus 로고    scopus 로고
    • Myocardial necrosis in ICU patients with acute non-cardiac disease: A prospective study
    • Arlati S, Brenna S, Prencipe L, et al. Myocardial necrosis in ICU patients with acute non-cardiac disease: a prospective study. Intensive Care Med 2000; 26:31-37
    • (2000) Intensive Care Med , vol.26 , pp. 31-37
    • Arlati, S.1    Brenna, S.2    Prencipe, L.3
  • 28
    • 0031967391 scopus 로고    scopus 로고
    • Serum cardiac troponin T as a prognostic marker in early sepsis
    • Spies C, Haude V, Fitzner R, et al. Serum cardiac troponin T as a prognostic marker in early sepsis. Chest 1998; 113:1053-1063
    • (1998) Chest , vol.113 , pp. 1053-1063
    • Spies, C.1    Haude, V.2    Fitzner, R.3
  • 29
    • 0029937134 scopus 로고    scopus 로고
    • Sepsis/septic shock: Participation of the microcirculation; an abbreviated review
    • Hinshaw LB. Sepsis/septic shock: participation of the microcirculation; an abbreviated review. Crit Care Med 1996; 24:1072-1078
    • (1996) Crit Care Med , vol.24 , pp. 1072-1078
    • Hinshaw, L.B.1
  • 30
    • 0031005632 scopus 로고    scopus 로고
    • Clinically recognized cardiac dysfunction: An independent determinant of mortality among critically ill patients
    • Kollef MH, Ladenson JH, Eisenberg PR. Clinically recognized cardiac dysfunction: an independent determinant of mortality among critically ill patients. Chest 1997; 111:1340-1347
    • (1997) Chest , vol.111 , pp. 1340-1347
    • Kollef, M.H.1    Ladenson, J.H.2    Eisenberg, P.R.3
  • 31
    • 0037016063 scopus 로고    scopus 로고
    • Cardiac troponin elevations in patients without acute coronary syndrome
    • Hamm CW, Giannitsis E, Katus HA. Cardiac troponin elevations in patients without acute coronary syndrome. Circulation 2002; 106:2871-2872
    • (2002) Circulation , vol.106 , pp. 2871-2872
    • Hamm, C.W.1    Giannitsis, E.2    Katus, H.A.3
  • 32
    • 0028999757 scopus 로고
    • Myocardial injury in critically ill patients: A frequently unrecognized complication
    • Guest TM, Ramantham AV, Tuteur PG, et al. Myocardial injury in critically ill patients: a frequently unrecognized complication. JAMA 1995; 273:1945-1949
    • (1995) JAMA , vol.273 , pp. 1945-1949
    • Guest, T.M.1    Ramantham, A.V.2    Tuteur, P.G.3
  • 33
    • 0028792186 scopus 로고
    • Cardiac troponin I is not expressed in fetal and healthy or diseased adult human skeletal muscle tissue
    • Bodor GS, Porterfield D, Voss EM, et al. Cardiac troponin I is not expressed in fetal and healthy or diseased adult human skeletal muscle tissue. Clin Chem 1995; 41:1710-1715
    • (1995) Clin Chem , vol.41 , pp. 1710-1715
    • Bodor, G.S.1    Porterfield, D.2    Voss, E.M.3
  • 34
    • 0031710957 scopus 로고    scopus 로고
    • False increase of cardiac troponin 1 with heterophilic antibodies
    • Fitzmaurice TF, Brown C, Rifai N, et al. False increase of cardiac troponin 1 with heterophilic antibodies. Clin Chem 1998; 44:2212-2214
    • (1998) Clin Chem , vol.44 , pp. 2212-2214
    • Fitzmaurice, T.F.1    Brown, C.2    Rifai, N.3
  • 35
    • 0000622306 scopus 로고    scopus 로고
    • Between-assay variation in false positive troponin I measurements in patients on renal dialysis or with positive rheumatoid factor
    • Schifman RB, James SH, Sadrzadeh SMH, et al. Between-assay variation in false positive troponin I measurements in patients on renal dialysis or with positive rheumatoid factor [abstract]. Clin Chem 1999; 45:A145
    • (1999) Clin Chem , vol.45
    • Schifman, R.B.1    James, S.H.2    Sadrzadeh, S.M.H.3
  • 36
    • 0032895820 scopus 로고    scopus 로고
    • False increases of troponin I attributable to incomplete separation of serum
    • Nosanchuk JS. False increases of troponin I attributable to incomplete separation of serum [letter]. Clin Chem 1999; 45:714
    • (1999) Clin Chem , vol.45 , pp. 714
    • Nosanchuk, J.S.1
  • 37
    • 0033927736 scopus 로고    scopus 로고
    • False-positive plasma troponin I with the AxSYM analyzer
    • Galambos C, Brink DS, Ritter D, et al. False-positive plasma troponin I with the AxSYM analyzer. Clin Chem 2000; 46:1014-1015
    • (2000) Clin Chem , vol.46 , pp. 1014-1015
    • Galambos, C.1    Brink, D.S.2    Ritter, D.3
  • 38
    • 0033248168 scopus 로고    scopus 로고
    • False positive troponin I in the MEIA due to the presence of rheumatoid factors in serum
    • Dasgupta A, Banjiree SK, Datta P. False positive troponin I in the MEIA due to the presence of rheumatoid factors in serum. Am J Clin Pathol 1999; 112:753-756
    • (1999) Am J Clin Pathol , vol.112 , pp. 753-756
    • Dasgupta, A.1    Banjiree, S.K.2    Datta, P.3
  • 39
    • 0033869592 scopus 로고    scopus 로고
    • An IgM antibody to Escherichia coli produces false-positive results in multiple immunometric assays
    • Covinsky M, Laterza O, Pfeifer JD, et al. An IgM antibody to Escherichia coli produces false-positive results in multiple immunometric assays. Clin Chem 2000; 46:1157-1161
    • (2000) Clin Chem , vol.46 , pp. 1157-1161
    • Covinsky, M.1    Laterza, O.2    Pfeifer, J.D.3
  • 40
    • 0022918233 scopus 로고
    • Incidence and specificity of interference in two-site immunoassays
    • Boscato LM, Stuart MC. Incidence and specificity of interference in two-site immunoassays. Clin Chem 1986; 32:1491-1495
    • (1986) Clin Chem , vol.32 , pp. 1491-1495
    • Boscato, L.M.1    Stuart, M.C.2
  • 41
    • 0032814344 scopus 로고    scopus 로고
    • Human anti-animal antibody interference in immunologic assays
    • Kricka LJ. Human anti-animal antibody interference in immunologic assays. Clin Chem 1999; 45:942-956
    • (1999) Clin Chem , vol.45 , pp. 942-956
    • Kricka, L.J.1
  • 42
    • 0022881264 scopus 로고
    • Circulating antibodies to mouse monoclonal immunoglobulins in normal subjects: Incidence, species specificity, and effects on a two-site assay for creatine kinase-MB isoenzyme
    • Thompson RJ, Jackson AP, Langlios N. Circulating antibodies to mouse monoclonal immunoglobulins in normal subjects: incidence, species specificity, and effects on a two-site assay for creatine kinase-MB isoenzyme. Clin Chem 1986; 32:476-481
    • (1986) Clin Chem , vol.32 , pp. 476-481
    • Thompson, R.J.1    Jackson, A.P.2    Langlios, N.3
  • 43
    • 18444375563 scopus 로고    scopus 로고
    • Performance of a revised cardiac troponin method that minimizes interferences from heterophilic antibodies
    • Kim WJ, Lazerta OF, Hock KG, et al. Performance of a revised cardiac troponin method that minimizes interferences from heterophilic antibodies. Clin Chem 2002; 48:1028-1034
    • (2002) Clin Chem , vol.48 , pp. 1028-1034
    • Kim, W.J.1    Lazerta, O.F.2    Hock, K.G.3
  • 44
    • 0029080326 scopus 로고
    • The incidence of antibody formation to OKT3 consequent to its use in organ transplantation
    • Carey G, Lisi PJ, Schroeder TJ. The incidence of antibody formation to OKT3 consequent to its use in organ transplantation. Transplantation 1995; 60:151-158
    • (1995) Transplantation , vol.60 , pp. 151-158
    • Carey, G.1    Lisi, P.J.2    Schroeder, T.J.3
  • 45
    • 0031004589 scopus 로고    scopus 로고
    • When do microbes stimulate rheumatoid factor?
    • Posnet DN, Edinger J. When do microbes stimulate rheumatoid factor? J Exp Med 1997; 185:1721-1723
    • (1997) J Exp Med , vol.185 , pp. 1721-1723
    • Posnet, D.N.1    Edinger, J.2
  • 46
    • 0026702425 scopus 로고
    • Eliminating interference from heterophilic antibodies in a two-site immunoassay for creatinine kinase MB by using Fab conjugate and polyclonal mouse IgG
    • Vaidya HC, Beatty GB. Eliminating interference from heterophilic antibodies in a two-site immunoassay for creatinine kinase MB by using Fab conjugate and polyclonal mouse IgG. Clin Chem 1992; 38:1737-1742
    • (1992) Clin Chem , vol.38 , pp. 1737-1742
    • Vaidya, H.C.1    Beatty, G.B.2
  • 47
    • 0033970391 scopus 로고    scopus 로고
    • Performance of the enhanced Abbott AxSYM cardiac troponin I reagent in patients with heterophilic antibodies
    • Yeo KT, Storm CA, Li Y, et al. Performance of the enhanced Abbott AxSYM cardiac troponin I reagent in patients with heterophilic antibodies. Clin Chim Acta 2000; 292:13-23
    • (2000) Clin Chim Acta , vol.292 , pp. 13-23
    • Yeo, K.T.1    Storm, C.A.2    Li, Y.3
  • 48
    • 0028826885 scopus 로고
    • CA125 determined by three methods in samples from patients with human anti-mouse antibodies (HAMA)
    • Turpeinen U, Lehtovirta P, Stenman UH. CA125 determined by three methods in samples from patients with human anti-mouse antibodies (HAMA). Clin Chem 1995; 41:1667-1669
    • (1995) Clin Chem , vol.41 , pp. 1667-1669
    • Turpeinen, U.1    Lehtovirta, P.2    Stenman, U.H.3
  • 49
    • 0033032667 scopus 로고    scopus 로고
    • False positive hCG assay result leading to unnecessary surgery and chemotherapy and needless occurrences of diabetes and coma
    • Cole LA, Rinne KM, Shahabi S, et al. False positive hCG assay result leading to unnecessary surgery and chemotherapy and needless occurrences of diabetes and coma. Clin Chem 1999; 45:313-314
    • (1999) Clin Chem , vol.45 , pp. 313-314
    • Cole, L.A.1    Rinne, K.M.2    Shahabi, S.3
  • 50
    • 0030892115 scopus 로고    scopus 로고
    • Heterophilic antibodies produce spuriously elevated concentrations of the MB isoenzyme of creatine kinase in a selected patient population
    • Sosolik RC, Hitcheock CL, Becker WJ. Heterophilic antibodies produce spuriously elevated concentrations of the MB isoenzyme of creatine kinase in a selected patient population. Am J Clin Pathol 1997; 107:506-510
    • (1997) Am J Clin Pathol , vol.107 , pp. 506-510
    • Sosolik, R.C.1    Hitcheock, C.L.2    Becker, W.J.3
  • 51
    • 0031754143 scopus 로고    scopus 로고
    • False increase in C-reactive protein attributable to heterophilic antibodies in two renal transplant patients treated with rabbit anti-lymphocyte globulin
    • Benoist JF, Orbach D, Biou D. False increase in C-reactive protein attributable to heterophilic antibodies in two renal transplant patients treated with rabbit anti-lymphocyte globulin. Clin Chem 1998; 44:1980-1985
    • (1998) Clin Chem , vol.44 , pp. 1980-1985
    • Benoist, J.F.1    Orbach, D.2    Biou, D.3
  • 52
    • 0034093961 scopus 로고    scopus 로고
    • Falsely elevated digoxin level of 45.9 ng/L due to interference from human antimouse antibody
    • Ingels M, Rangan C, Mortin JP, et al. Falsely elevated digoxin level of 45.9 ng/L due to interference from human antimouse antibody. J Toxicol Clin Toxicol 2000; 38:343-345
    • (2000) J Toxicol Clin Toxicol , vol.38 , pp. 343-345
    • Ingels, M.1    Rangan, C.2    Mortin, J.P.3
  • 53
    • 0032779758 scopus 로고    scopus 로고
    • Heterophile antibodies to bovine and caprine proteins causing false-positive human immunodeficiency virus type 1 and other enzyme-linked immunosorbent assay results
    • Willman JH, Martins TB, Jaskowski TD, et al. Heterophile antibodies to bovine and caprine proteins causing false-positive human immunodeficiency virus type 1 and other enzyme-linked immunosorbent assay results. Clin Diagn Lab Immunol 1999; 6:615-616
    • (1999) Clin Diagn Lab Immunol , vol.6 , pp. 615-616
    • Willman, J.H.1    Martins, T.B.2    Jaskowski, T.D.3
  • 54
    • 0032742968 scopus 로고    scopus 로고
    • High percentage of false positive cardiac troponin I results in patients with rheumatoid factor
    • Krahn J, Parry DM, Leroux M, et al. High percentage of false positive cardiac troponin I results in patients with rheumatoid factor. Clin Biochem 1999; 32:477-480
    • (1999) Clin Biochem , vol.32 , pp. 477-480
    • Krahn, J.1    Parry, D.M.2    Leroux, M.3
  • 55
    • 0030952403 scopus 로고    scopus 로고
    • Prevention of analytical false positive increases of cardiac troponin I on the Stratus II analyzer
    • Roberts WL, Calcote CB, De BK, et al. Prevention of analytical false positive increases of cardiac troponin I on the Stratus II analyzer [letter]. Clin Chem 1997; 43:860-861
    • (1997) Clin Chem , vol.43 , pp. 860-861
    • Roberts, W.L.1    Calcote, C.B.2    De, B.K.3
  • 56
    • 0033756284 scopus 로고    scopus 로고
    • Comparison of single and repeat centrifugation of blood specimens collected in BD evacuated blood collection tubes containing a clot activator for cardiac troponin I assay on the ACCESS analyzer
    • Beyne P, Vigier JP, Bourgoin P, et al. Comparison of single and repeat centrifugation of blood specimens collected in BD evacuated blood collection tubes containing a clot activator for cardiac troponin I assay on the ACCESS analyzer. Clin Chem 2000; 46:1869-1870
    • (2000) Clin Chem , vol.46 , pp. 1869-1870
    • Beyne, P.1    Vigier, J.P.2    Bourgoin, P.3
  • 57
    • 85030875919 scopus 로고    scopus 로고
    • Abbott Park, IL; Abbott Laboratories
    • Abbott AxSYM system operations manual. Vol 1. Abbott Park, IL; Abbott Laboratories, 1996; 8-19
    • (1996) Abbott AxSYM System Operations Manual , vol.1 , pp. 8-19


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.