메뉴 건너뛰기




Volumn 54, Issue 20, 2009, Pages 6369-6382

Statistical LOR estimation for a high-resolution dMiCE PET detector

Author keywords

[No Author keywords available]

Indexed keywords

ANNIHILATION PHOTONS; CONDITIONAL EXPECTATION; CROSS SECTION; CRYSTAL PAIRS; DEPTH OF INTERACTIONS; DEPTH-OF-INTERACTION INFORMATIONS; DETECTOR ELEMENTS; DETECTOR MODULE; ESTIMATION ALGORITHM; HIGH RESOLUTION; HIGH-RESOLUTION PET; LIGHT COLLECTION; LIGHT-SHARING; LINE-OF-RESPONSES; MICRO-PIXEL; MONTE CARLO EXPERIMENTS; MULTIPLE INTERACTIONS; PET DETECTORS; PHOTO-SENSORS; PHOTON INTERACTIONS; PROTOTYPE SYSTEM; THREE-DIMENSIONAL INTERACTION;

EID: 71049179059     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/54/20/022     Document Type: Article
Times cited : (18)

References (17)
  • 2
    • 33750417967 scopus 로고    scopus 로고
    • Intrinsic spatial resolution and parallax correction using depth-encoding PET detector modules based on position-sensitive APD readout
    • Dokhale P, Silverman R, Shah K, Farrell R, Mcclish M, Entine G and Cherry S 2006 Intrinsic spatial resolution and parallax correction using depth-encoding PET detector modules based on position-sensitive APD readout IEEE Trans. Nucl. Sci. 53 2666-70
    • (2006) IEEE Trans. Nucl. Sci. , vol.53 , Issue.5 , pp. 2666-2670
    • Dokhale, P.1    Silverman, R.2    Shah, K.3    Farrell, R.4    McClish, M.5    Entine, G.6    Cherry, S.7
  • 3
    • 34249093003 scopus 로고    scopus 로고
    • Measurements of wavelength shifting (WLS) fibre readout for a highly multiplexed, depth-encoding PET detector
    • Du H, Yang Y and Cherry S R 2007 Measurements of wavelength shifting (WLS) fibre readout for a highly multiplexed, depth-encoding PET detector Phys. Med. Biol. 52 2499-514
    • (2007) Phys. Med. Biol. , vol.52 , Issue.9 , pp. 2499-2514
    • Du, H.1    Yang, Y.2    Cherry, S.R.3
  • 4
    • 42449159363 scopus 로고    scopus 로고
    • Comparison of four depth-encoding PET detector modules with wavelength shifting (WLS) and optical fiber read-out
    • Du H, Yang Y and Cherry S R 2008 Comparison of four depth-encoding PET detector modules with wavelength shifting (WLS) and optical fiber read-out Phys. Med. Biol. 53 1829-42
    • (2008) Phys. Med. Biol. , vol.53 , Issue.7 , pp. 1829-1842
    • Du, H.1    Yang, Y.2    Cherry, S.R.3
  • 6
    • 0035355180 scopus 로고    scopus 로고
    • An LSO scintillator array for a PET detector module with depth of interaction measurement
    • Huber J, Moses W, Andreaco M and Petterson O 2001 An LSO scintillator array for a PET detector module with depth of interaction measurement IEEE Trans. Nucl. Sci. 48 684-8
    • (2001) IEEE Trans. Nucl. Sci. , vol.48 , Issue.3 , pp. 684-688
    • Huber, J.1    Moses, W.2    Andreaco, M.3    Petterson, O.4
  • 10
    • 33751197907 scopus 로고    scopus 로고
    • Ling T 2007 High resolution gamma detector for small-animal positron emission tomography PhD Thesis University of Washington
    • (2007) PhD Thesis
    • Ling, T.1
  • 11
    • 17644367489 scopus 로고    scopus 로고
    • Characterization and readout of MADPET-II detector modules: Validation of a unique design concept for high resolution small animal PET
    • McElroy D, Pimpl W, Pichler B, Rafecas M, Schuler T and Ziegler S 2005 Characterization and readout of MADPET-II detector modules: validation of a unique design concept for high resolution small animal PET IEEE Trans. Nucl. Sci. 52 199-204
    • (2005) IEEE Trans. Nucl. Sci. , vol.52 , Issue.1 , pp. 199-204
    • McElroy, D.1    Pimpl, W.2    Pichler, B.3    Rafecas, M.4    Schuler, T.5    Ziegler, S.6
  • 12
    • 0032096198 scopus 로고    scopus 로고
    • Design of a depth of interaction (DOI) PET detector module
    • Miyaoka R, Lewellen T, Yu H and McDaniel D 1998 Design of a depth of interaction (DOI) PET detector module IEEE Trans. Nucl. Sci. 45 1069-73
    • (1998) IEEE Trans. Nucl. Sci. , vol.45 , Issue.3 , pp. 1069-1073
    • Miyaoka, R.1    Lewellen, T.2    Yu, H.3    McDaniel, D.4
  • 13
    • 48149096565 scopus 로고    scopus 로고
    • Accurately positioning events in a high-resolution PET system that uses 3D CZT detectors
    • Pratx G and Levin C S 2007 Accurately positioning events in a high-resolution PET system that uses 3D CZT detectors IEEE Nucl. Sci. Symp. Conf. Rec. 4 2660-4
    • (2007) IEEE Nucl. Sci. Symp. Conf. Rec. , vol.4 , pp. 2660-2664
    • Pratx, G.1    Levin, C.S.2
  • 15
    • 3342923552 scopus 로고    scopus 로고
    • Calibration of a PEM detector with depth of interaction measurement
    • Wang G, Huber J, Moses W, Choong W and Maltz J 2004 Calibration of a PEM detector with depth of interaction measurement IEEE Trans. Nucl. Sci. 51 775-81
    • (2004) IEEE Trans. Nucl. Sci. , vol.51 , Issue.3 , pp. 775-781
    • Wang, G.1    Huber, J.2    Moses, W.3    Choong, W.4    Maltz, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.