-
2
-
-
0026265751
-
High resolution positron emission tomography for medical science studies
-
Budinger T F, Derenzo S E, Huesman R H, Jagust W J and Valk P E 1991 High resolution positron emission tomography for medical science studies Acta Radiol. 376 15-23
-
(1991)
Acta Radiol.
, vol.376
, pp. 15-23
-
-
Budinger, T.F.1
Derenzo, S.E.2
Huesman, R.H.3
Jagust, W.J.4
Valk, P.E.5
-
3
-
-
0042427569
-
Evaluation of a position sensitive avalanche photodiode for PET
-
Burr K C et al 2003 Evaluation of a position sensitive avalanche photodiode for PET IEEE Trans. Nucl. Sci. 50 792-6
-
(2003)
IEEE Trans. Nucl. Sci.
, vol.50
, Issue.4
, pp. 792-796
-
-
Burr, K.C.1
Al, E.2
-
4
-
-
34648840245
-
MicroPET: A high resolution PET scanner for imaging small animals
-
Cherry S R et al 1997 MicroPET: a high resolution PET scanner for imaging small animals IEEE Trans. Nucl. Sci. 44 1161-6
-
(1997)
IEEE Trans. Nucl. Sci.
, vol.44
, Issue.3
, pp. 1161-1166
-
-
Cherry, S.R.1
Al, E.2
-
5
-
-
34249093003
-
Measurements of wavelength shifting (WLS) fibre readout for a highly multiplexed, depth-encoding PET detector
-
Du H, Yang Y and Cherry S R 2007 Measurements of wavelength shifting (WLS) fibre readout for a highly multiplexed, depth-encoding PET detector Phys. Med. Biol. 52 2499-514
-
(2007)
Phys. Med. Biol.
, vol.52
, Issue.9
, pp. 2499-2514
-
-
Du, H.1
Yang, Y.2
Cherry, S.R.3
-
6
-
-
17644388448
-
Three-dimensional array of scintillation crystals with proper reflector arrangement for a depth of interaction detector
-
Orita N, Murayama H, Kawai H, Inadama N and Tsuda T 2005 Three-dimensional array of scintillation crystals with proper reflector arrangement for a depth of interaction detector IEEE Trans. Nucl. Sci. 52 8-14
-
(2005)
IEEE Trans. Nucl. Sci.
, vol.52
, Issue.1
, pp. 8-14
-
-
Orita, N.1
Murayama, H.2
Kawai, H.3
Inadama, N.4
Tsuda, T.5
-
7
-
-
0033311839
-
Depth identification accuracy of a three layer phoswich PET detector module
-
Seidel J, Vaquero J J, Siegel S, Gandler W R and Green M V 1999 Depth identification accuracy of a three layer phoswich PET detector module IEEE Trans. Nucl. Sci. 46 485-90
-
(1999)
IEEE Trans. Nucl. Sci.
, vol.46
, Issue.3
, pp. 485-490
-
-
Seidel, J.1
Vaquero, J.J.2
Siegel, S.3
Gandler, W.R.4
Green, M.V.5
-
8
-
-
0030164341
-
Simple charge division readouts for imaging scintillator arrays using a multi-channel PMT
-
Siegel S, Silverman R W and Cherry S R 1996 Simple charge division readouts for imaging scintillator arrays using a multi-channel PMT IEEE Trans. Nucl. Sci. 43 1634-41
-
(1996)
IEEE Trans. Nucl. Sci.
, vol.43
, Issue.3
, pp. 1634-1641
-
-
Siegel, S.1
Silverman, R.W.2
Cherry, S.R.3
-
9
-
-
0038510212
-
MicroPET II: Design, development and initial performance of an improved microPET scanner for small-animal imaging
-
Tai Y C, Chatziioannou A F, Yang Y, Silverman R W, Meadors K, Siegle S, Newport D F, Stickel J R and Cherry S R 2003 MicroPET II: design, development and initial performance of an improved microPET scanner for small-animal imaging Phys. Med. Biol. 48 1519-37
-
(2003)
Phys. Med. Biol.
, vol.48
, Issue.11
, pp. 1519-1537
-
-
Tai, Y.C.1
Chatziioannou, A.F.2
Yang, Y.3
Silverman, R.W.4
Meadors, K.5
Siegle, S.6
Newport, D.F.7
Stickel, J.R.8
Cherry, S.R.9
-
10
-
-
23844544833
-
Design and performance of a prototype whole-body PET/CT scanner with fiber optic readout
-
Worstell W et al 2004 Design and performance of a prototype whole-body PET/CT scanner with fiber optic readout Nuclear Science Symp. and Medical Imaging Conf. (Rome, Italy) pp 3280-4
-
(2004)
Nuclear Science Symp. and Medical Imaging Conf.
, pp. 3280-3284
-
-
Worstell, W.1
Al, E.2
-
12
-
-
33645690906
-
Observations regarding scatter fraction and NEC measurements for small animal PET
-
Yang Y and Cherry S R 2006 Observations regarding scatter fraction and NEC measurements for small animal PET IEEE Trans. Nucl. Sci. 53 127-32
-
(2006)
IEEE Trans. Nucl. Sci.
, vol.53
, Issue.1
, pp. 127-132
-
-
Yang, Y.1
Cherry, S.R.2
-
13
-
-
33645990583
-
Depth of interaction resolution measurements for a high resolution PET detector using position sensitive avalanche photodiodes
-
Yang Y, Dokhale P A, Silverman R W, Shah K S, McClish M A, Farrell R, Entine G and Cherry S R 2006 Depth of interaction resolution measurements for a high resolution PET detector using position sensitive avalanche photodiodes Phys. Med. Biol. 51 2131-42
-
(2006)
Phys. Med. Biol.
, vol.51
, Issue.9
, pp. 2131-2142
-
-
Yang, Y.1
Dokhale, P.A.2
Silverman, R.W.3
Shah, K.S.4
McClish, M.A.5
Farrell, R.6
Entine, G.7
Cherry, S.R.8
|