메뉴 건너뛰기




Volumn 51, Issue 3 II, 2004, Pages 775-781

Calibration of a PEM detector with depth of interaction measurement

Author keywords

Biomedical imaging; Calibration; Depth of interaction (DOI); Detectors; Positron emission tomography (PET)

Indexed keywords

MEDICAL IMAGING; OPTIMIZATION; PHOTODIODES; PHOTOMULTIPLIERS; POSITRON EMISSION TOMOGRAPHY; SCINTILLATION;

EID: 3342923552     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2004.829785     Document Type: Article
Times cited : (25)

References (11)
  • 1
    • 0028494319 scopus 로고
    • Design studies for a PET detector module using a PIN photodiode to measure depth of interaction
    • W. W. Moses and S. E. Derenzo, "Design studies for a PET detector module using a PIN photodiode to measure depth of interaction," IEEE Trans. Nucl. Sci., vol. 41, pp. 1441-1445, 1994.
    • (1994) IEEE Trans. Nucl. Sci. , vol.41 , pp. 1441-1445
    • Moses, W.W.1    Derenzo, S.E.2
  • 2
    • 0033357392 scopus 로고    scopus 로고
    • A study of depth of interaction measurement using bent optical fibers
    • Y. P. Shao and S. R. Cherry, "A study of depth of interaction measurement using bent optical fibers," IEEE Trans. Nucl. Sci., vol. 46, pp. 618-623, 1999.
    • (1999) IEEE Trans. Nucl. Sci. , vol.46 , pp. 618-623
    • Shao, Y.P.1    Cherry, S.R.2
  • 3
    • 0034206730 scopus 로고    scopus 로고
    • Design studies of a high resolution PET detector using APD arrays
    • Y. Shao et al., "Design studies of a high resolution PET detector using APD arrays," IEEE Trans. Nucl. Sci., vol. 47, pp. 1051-1057, 2000.
    • (2000) IEEE Trans. Nucl. Sci. , vol.47 , pp. 1051-1057
    • Shao, Y.1
  • 4
    • 0035355180 scopus 로고    scopus 로고
    • A LSO scintillator array for a PET detector module with depth of interaction measurement
    • J. S. Huber et al., "A LSO scintillator array for a PET detector module with depth of interaction measurement," IEEE Trans. Nucl. Sci., vol. 48, pp. 684-688, 2001.
    • (2001) IEEE Trans. Nucl. Sci. , vol.48 , pp. 684-688
    • Huber, J.S.1
  • 6
    • 0029358347 scopus 로고
    • A room temperature LSO/PIN photodiode PET detector module that measures depth of interaction
    • W. W. Moses, S. E. Derenzo, and C. L. Melcher, "A room temperature LSO/PIN photodiode PET detector module that measures depth of interaction," IEEE Trans. Nucl. Sci., vol. 42, pp. 1085-1089, 1995.
    • (1995) IEEE Trans. Nucl. Sci. , vol.42 , pp. 1085-1089
    • Moses, W.W.1    Derenzo, S.E.2    Melcher, C.L.3
  • 7
    • 0028184921 scopus 로고
    • A custom CMOS integrated circuit for PET tomograph front-end applications
    • L. Klaisner et al., Ed., San Francisco, CA
    • D. M. Binkley et al., "A custom CMOS integrated circuit for PET tomograph front-end applications," in Proc. IEEE 1993 Nuclear Science Symp./Medical Imaging Conf., L. Klaisner et al., Ed., San Francisco, CA, 1993, pp. 867-871.
    • (1993) Proc. IEEE 1993 Nuclear Science Symp./Medical Imaging Conf. , pp. 867-871
    • Binkley, D.M.1
  • 8
    • 0035355046 scopus 로고    scopus 로고
    • The electronics system for the LBNL positron emission mammography (PEM) camera
    • W. W. Moses et al., "The electronics system for the LBNL positron emission mammography (PEM) camera," IEEE Trans. Nucl. Sci., vol. 48, pp. 632-636, 2001.
    • (2001) IEEE Trans. Nucl. Sci. , vol.48 , pp. 632-636
    • Moses, W.W.1
  • 9
    • 0026902676 scopus 로고
    • Cerium-doped lutetium oxyorthosilicate: A fast, efficient new scintillator
    • C. L. Melcher and J. S. Schweitzer, "Cerium-doped lutetium oxyorthosilicate: A fast, efficient new scintillator," IEEE Trans. Nucl. Sci., vol. 39, pp. 502-505, 1992.
    • (1992) IEEE Trans. Nucl. Sci. , vol.39 , pp. 502-505
    • Melcher, C.L.1    Schweitzer, J.S.2
  • 10
    • 0036624298 scopus 로고    scopus 로고
    • Dual APD array readout of LSO crystals: Optimization of crystal surface treatment
    • Y. Shao et al., "Dual APD array readout of LSO crystals: Optimization of crystal surface treatment," IEEE Trans. Nucl. Sci., vol. 49, pp. 649-654, 2000.
    • (2000) IEEE Trans. Nucl. Sci. , vol.49 , pp. 649-654
    • Shao, Y.1
  • 11
    • 0038720382 scopus 로고    scopus 로고
    • Measurement of the depth of interaction of an LSO scintillator using a planar process APD
    • E. Gramsch, R. Avila, and P. Bui, "Measurement of the depth of interaction of an LSO scintillator using a planar process APD," IEEE Trans. Nucl. Sci., vol. 50, pp. 307-312, 2003.
    • (2003) IEEE Trans. Nucl. Sci. , vol.50 , pp. 307-312
    • Gramsch, E.1    Avila, R.2    Bui, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.