1
-
-
0043075804
-
Effect of two different bypass techniques on the serum troponin-T levels in newborns and children: Does pH-Stat provide better protection?
-
Nagy ZL, Collins M, Sharpe T et al. Effect of two different bypass techniques on the serum troponin-T levels in newborns and children: does pH-Stat provide better protection? Circulation 2003; 108: 577-82.
-
(2003)
Circulation
, vol.108
, pp. 577-582
-
-
Nagy, Z.L.1
Collins, M.2
Sharpe, T.3
-
2
-
-
0032979974
-
Cardiopulmonary bypass in infants and children: How is it different?
-
Davies LK. Cardiopulmonary bypass in infants and children: how is it different? J Cardiothorac Vasc Anesth 1999; 13: 330-45.
-
(1999)
J. Cardiothorac. Vasc. Anesth.
, vol.13
, pp. 330-345
-
-
Davies, L.K.1
-
4
-
-
0141957118
-
The effect of modified ultrafiltration on the postoperative course in patients with congenital heart disease
-
Gaynor JW. The effect of modified ultrafiltration on the postoperative course in patients with congenital heart disease. Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu 2003; 6: 128-39.
-
(2003)
Semin. Thorac. Cardiovasc. Surg. Pediatr. Card. Surg. Annu.
, vol.6
, pp. 128-139
-
-
Gaynor, J.W.1
-
5
-
-
0031684222
-
Modified ultrafiltration in paediatric cardiopulmonary bypass
-
Wang W, Huang HM, Zhu DM, Chen H, So ZK, Ding WX. Modified ultrafiltration in paediatric cardiopulmonary bypass. Perfusion 1998; 13: 304-10.
-
(1998)
Perfusion
, vol.13
, pp. 304-310
-
-
Wang, W.1
Huang, H.M.2
Zhu, D.M.3
Chen, H.4
So, Z.K.5
Ding, W.X.6
-
6
-
-
0036245945
-
Early post-operative monocyte deactivation predicts systemic inflammation and prolonged stay in pediatric cardiac intensive care
-
Allen ML, Peters MJ, Goldman A et al. Early post-operative monocyte deactivation predicts systemic inflammation and prolonged stay in pediatric cardiac intensive care. Crit Care Med 2002; 30: 1140-45.
-
(2002)
Crit. Care Med.
, vol.30
, pp. 1140-1145
-
-
Allen, M.L.1
Peters, M.J.2
Goldman, A.3
-
7
-
-
0242551678
-
The Capiox RX05 oxygenator: Pediatric clinical observations
-
Tinius JA, Dragomer D, Klutka F, VanBebber A, Cerney K. The Capiox RX05 oxygenator: pediatric clinical observations. Perfusion 2003; 18: 321-23.
-
(2003)
Perfusion
, vol.18
, pp. 321-323
-
-
Tinius, J.A.1
Dragomer, D.2
Klutka, F.3
VanBebber, A.4
Cerney, K.5
-
8
-
-
0033019199
-
The incidence and cause of emergency oxygenator changeovers
-
Fischer AR. The incidence and cause of emergency oxygenator changeovers. Perfusion 1999; 14: 207-12.
-
(1999)
Perfusion
, vol.14
, pp. 207-212
-
-
Fischer, A.R.1
-
9
-
-
0032744911
-
Oxygenator thrombosis: An international phenomenon
-
Schaadt J. Oxygenator thrombosis: an international phenomenon. Perfusion 1999; 14: 425-35.
-
(1999)
Perfusion
, vol.14
, pp. 425-435
-
-
Schaadt, J.1
-
10
-
-
0032590022
-
Effect of trillium biopassive surface coating of the oxygenator on platelet count drop during cardiopulmonary bypass
-
Palanzo DA, Zarro DL, Montesano RM et al. Effect of trillium biopassive surface coating of the oxygenator on platelet count drop during cardiopulmonary bypass. Perfusion 1999; 14: 473-79.
-
(1999)
Perfusion
, vol.14
, pp. 473-479
-
-
Palanzo, D.A.1
Zarro, D.L.2
Montesano, R.M.3
-
11
-
-
0242636465
-
The effect of oxygenator membranes on blood: A comparison of two oxygenators in open-heart surgery
-
Noora J, Lamy A, Smith KM et al. The effect of oxygenator membranes on blood: a comparison of two oxygenators in open-heart surgery. Perfusion 2003; 18: 313-20.
-
(2003)
Perfusion
, vol.18
, pp. 313-320
-
-
Noora, J.1
Lamy, A.2
Smith, K.M.3
-
12
-
-
0017684393
-
Function of human platelets during extracorporeal circulation
-
Hennessy VL Jr, Hicks RE, Niewiarowski S, Edmunds LH Jr, Colman RW. Function of human platelets during extracorporeal circulation. Am J Physiol 1977; 232: H622-28.
-
(1977)
Am. J. Physiol.
, vol.232
-
-
Hennessy Jr., V.L.1
Hicks, R.E.2
Niewiarowski, S.3
Edmunds Jr., L.H.4
Colman, R.W.5
-
15
-
-
0032870606
-
Heparin coating extends the durability of oxygenators used for cardiopulmonary support
-
Usui A, Hiroura M, Kawamura M. Heparin coating extends the durability of oxygenators used for cardiopulmonary support. Artif Organs 1999; 23: 840-44.
-
(1999)
Artif. Organs
, vol.23
, pp. 840-844
-
-
Usui, A.1
Hiroura, M.2
Kawamura, M.3
-
16
-
-
0028336709
-
Membrane oxygenators: Influence of design on performance
-
Gaylor JDS, Hickey S, Bell G, Pei JM. Membrane oxygenators: influence of design on performance. Perfusion 1994; 9: 173-80.
-
(1994)
Perfusion
, vol.9
, pp. 173-180
-
-
Gaylor, J.D.S.1
Hickey, S.2
Bell, G.3
Pei, J.M.4
|