메뉴 건너뛰기




Volumn 19, Issue 5, 2004, Pages 315-321

Ex vivo evaluation of a new neonatal/infant oxygenator: Comparison of the Terumo CAPIOX® Baby RX with Dideco Lilliput 1 and Polystan Safe Micro in the piglet model

Author keywords

[No Author keywords available]

Indexed keywords

HEMOGLOBIN; OXYGEN; POLYMER; THROMBIN ANTITHROMBIN COMPLEX;

EID: 5444240838     PISSN: 02676591     EISSN: None     Source Type: Journal    
DOI: 10.1191/0267659104pf758oa     Document Type: Article
Times cited : (19)

References (16)
  • 1
    • 0043075804 scopus 로고    scopus 로고
    • Effect of two different bypass techniques on the serum troponin-T levels in newborns and children: Does pH-Stat provide better protection?
    • Nagy ZL, Collins M, Sharpe T et al. Effect of two different bypass techniques on the serum troponin-T levels in newborns and children: does pH-Stat provide better protection? Circulation 2003; 108: 577-82.
    • (2003) Circulation , vol.108 , pp. 577-582
    • Nagy, Z.L.1    Collins, M.2    Sharpe, T.3
  • 2
    • 0032979974 scopus 로고    scopus 로고
    • Cardiopulmonary bypass in infants and children: How is it different?
    • Davies LK. Cardiopulmonary bypass in infants and children: how is it different? J Cardiothorac Vasc Anesth 1999; 13: 330-45.
    • (1999) J. Cardiothorac. Vasc. Anesth. , vol.13 , pp. 330-345
    • Davies, L.K.1
  • 4
    • 0141957118 scopus 로고    scopus 로고
    • The effect of modified ultrafiltration on the postoperative course in patients with congenital heart disease
    • Gaynor JW. The effect of modified ultrafiltration on the postoperative course in patients with congenital heart disease. Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu 2003; 6: 128-39.
    • (2003) Semin. Thorac. Cardiovasc. Surg. Pediatr. Card. Surg. Annu. , vol.6 , pp. 128-139
    • Gaynor, J.W.1
  • 6
    • 0036245945 scopus 로고    scopus 로고
    • Early post-operative monocyte deactivation predicts systemic inflammation and prolonged stay in pediatric cardiac intensive care
    • Allen ML, Peters MJ, Goldman A et al. Early post-operative monocyte deactivation predicts systemic inflammation and prolonged stay in pediatric cardiac intensive care. Crit Care Med 2002; 30: 1140-45.
    • (2002) Crit. Care Med. , vol.30 , pp. 1140-1145
    • Allen, M.L.1    Peters, M.J.2    Goldman, A.3
  • 8
    • 0033019199 scopus 로고    scopus 로고
    • The incidence and cause of emergency oxygenator changeovers
    • Fischer AR. The incidence and cause of emergency oxygenator changeovers. Perfusion 1999; 14: 207-12.
    • (1999) Perfusion , vol.14 , pp. 207-212
    • Fischer, A.R.1
  • 9
    • 0032744911 scopus 로고    scopus 로고
    • Oxygenator thrombosis: An international phenomenon
    • Schaadt J. Oxygenator thrombosis: an international phenomenon. Perfusion 1999; 14: 425-35.
    • (1999) Perfusion , vol.14 , pp. 425-435
    • Schaadt, J.1
  • 10
    • 0032590022 scopus 로고    scopus 로고
    • Effect of trillium biopassive surface coating of the oxygenator on platelet count drop during cardiopulmonary bypass
    • Palanzo DA, Zarro DL, Montesano RM et al. Effect of trillium biopassive surface coating of the oxygenator on platelet count drop during cardiopulmonary bypass. Perfusion 1999; 14: 473-79.
    • (1999) Perfusion , vol.14 , pp. 473-479
    • Palanzo, D.A.1    Zarro, D.L.2    Montesano, R.M.3
  • 11
    • 0242636465 scopus 로고    scopus 로고
    • The effect of oxygenator membranes on blood: A comparison of two oxygenators in open-heart surgery
    • Noora J, Lamy A, Smith KM et al. The effect of oxygenator membranes on blood: a comparison of two oxygenators in open-heart surgery. Perfusion 2003; 18: 313-20.
    • (2003) Perfusion , vol.18 , pp. 313-320
    • Noora, J.1    Lamy, A.2    Smith, K.M.3
  • 15
    • 0032870606 scopus 로고    scopus 로고
    • Heparin coating extends the durability of oxygenators used for cardiopulmonary support
    • Usui A, Hiroura M, Kawamura M. Heparin coating extends the durability of oxygenators used for cardiopulmonary support. Artif Organs 1999; 23: 840-44.
    • (1999) Artif. Organs , vol.23 , pp. 840-844
    • Usui, A.1    Hiroura, M.2    Kawamura, M.3
  • 16
    • 0028336709 scopus 로고
    • Membrane oxygenators: Influence of design on performance
    • Gaylor JDS, Hickey S, Bell G, Pei JM. Membrane oxygenators: influence of design on performance. Perfusion 1994; 9: 173-80.
    • (1994) Perfusion , vol.9 , pp. 173-180
    • Gaylor, J.D.S.1    Hickey, S.2    Bell, G.3    Pei, J.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.