메뉴 건너뛰기




Volumn 8, Issue 11, 2009, Pages 5317-5324

The benefit of combining nLC-MALDI-Orbitrap MS data with nLC-MALDI-TOF/TOF data for proteomic analyses employing elastase

Author keywords

Calibration; Elastase; MALDI Orbitrap

Indexed keywords

ELASTASE; PROTEOME;

EID: 70449354921     PISSN: 15353893     EISSN: None     Source Type: Journal    
DOI: 10.1021/pr900557k     Document Type: Article
Times cited : (14)

References (24)
  • 2
    • 58149119846 scopus 로고    scopus 로고
    • Evaluation of the low-specificity protease elastase for large-scale phosphoproteome analysis
    • Wang, B.; Malik, R.; Nigg, E. A.; Korner, R. Evaluation of the low-specificity protease elastase for large-scale phosphoproteome analysis. Anal. Chem. 2008, 80 (24), 9526-9533.
    • (2008) Anal. Chem. , vol.80 , Issue.24 , pp. 9526-9533
    • Wang, B.1    Malik, R.2    Nigg, E.A.3    Korner, R.4
  • 3
    • 34548291476 scopus 로고    scopus 로고
    • Accurate mass measurements in proteomics
    • Liu, T.; Belov, M. E.; Jaitly, N.; Qian, W. J.; Smith, R. D. Accurate mass measurements in proteomics. Chem. Rev. 2007, 107 (8), 3621-3653.
    • (2007) Chem. Rev. , vol.107 , Issue.8 , pp. 3621-3653
    • Liu, T.1    Belov, M.E.2    Jaitly, N.3    Qian, W.J.4    Smith, R.D.5
  • 4
    • 0033565832 scopus 로고    scopus 로고
    • Role of accurate mass measurement ( 10 ppm) in protein identification strategies employing MS or MS/MS and database searching
    • Clauser, K. R.; Baker, P.; Burlingame, A. L. Role of accurate mass measurement (( 10 ppm) in protein identification strategies employing MS or MS/MS and database searching. Anal. Chem. 1999, 71 (14), 2871-2882.
    • (1999) Anal. Chem. , vol.71 , Issue.14 , pp. 2871-2882
    • Clauser, K.R.1    Baker, P.2    Burlingame, A.L.3
  • 5
    • 2742576125 scopus 로고    scopus 로고
    • Accuracy requirements for peptide characterization by monoisotopic molecular mass measurements
    • Zubarev, R. A.; Håkansson, P.; Sundqvist, B. Accuracy requirements for peptide characterization by monoisotopic molecular mass measurements. Anal. Chem. 1996, 68, 4060-4063. (Pubitemid 126682575)
    • (1996) Analytical Chemistry , vol.68 , Issue.22 , pp. 4060-4063
    • Zubarev, R.A.1    Hakansson, P.2    Sundqvist, B.3
  • 6
    • 2342593352 scopus 로고    scopus 로고
    • De novo sequencing, peptide composition analysis, and composition-based sequencing: A new strategy employing accurate mass determination by fourier transform ion cyclotron resonance mass spectrometry
    • DOI 10.1016/j.jasms.2004.01.007, PII S104403050400073X
    • Spengler, B. De novo sequencing, peptide composition analysis, and composition-based sequencing: a new strategy employing accurate mass determination by fourier transform ion cyclotron resonance mass spectrometry. J. Am. Soc. Mass Spectrom. 2004, 15 (5), 703-714. (Pubitemid 38581097)
    • (2004) Journal of the American Society for Mass Spectrometry , vol.15 , Issue.5 , pp. 703-714
    • Spengler, B.1
  • 7
    • 0037353846 scopus 로고    scopus 로고
    • Statistical characterization of ion trap tandem mass spectra from doubly charged tryptic peptides
    • Tabb, D. L.; Smith, L. L.; Breci, L. A.; Wysocki, V. H.; Lin, D.; Yates, J. R., III. Statistical characterization of ion trap tandem mass spectra from doubly charged tryptic peptides. Anal. Chem. 2003, 75 (5), 1155-1163.
    • (2003) Anal. Chem. , vol.75 , Issue.5 , pp. 1155-1163
    • Tabb, D.L.1    Smith, L.L.2    Breci, L.A.3    Wysocki, V.H.4    Lin, D.5    Yates III, J.R.6
  • 8
    • 34247354641 scopus 로고    scopus 로고
    • Fragmentation characteristics of collision-induced dissociation in MALDI TOF/TOF mass spectrometry
    • DOI 10.1021/ac061455v
    • Khatun, J.; Ramkissoon, K.; Giddings, M. C. Fragmentation characteristics of collision-induced dissociation in MALDI TOF/TOF mass spectrometry. Anal. Chem. 2007, 79 (8), 3032-3040. (Pubitemid 46640524)
    • (2007) Analytical Chemistry , vol.79 , Issue.8 , pp. 3032-3040
    • Khatun, J.1    Ramkissoon, K.2    Giddings, M.C.3
  • 9
    • 13844275962 scopus 로고    scopus 로고
    • Mass spectrometry of peptides and proteins
    • Wysocki, V. H.; Resing, K. A.; Zhang, Q.; Cheng, G. Mass spectrometry of peptides and proteins. Methods 2005, 35 (3), 211-222.
    • (2005) Methods , vol.35 , Issue.3 , pp. 211-222
    • Wysocki, V.H.1    Resing, K.A.2    Zhang, Q.3    Cheng, G.4
  • 10
    • 1442324456 scopus 로고    scopus 로고
    • Influence of basic residue content on fragment ion peak intensities in low-energy collision-induced dissociation spectra of peptides
    • Tabb, D. L.; Huang, Y.; Wysocki, V. H.; Yates, J. R., III. Influence of basic residue content on fragment ion peak intensities in low-energy collision-induced dissociation spectra of peptides. Anal. Chem. 2004, 76 (5), 1243-1248.
    • (2004) Anal. Chem. , vol.76 , Issue.5 , pp. 1243-1248
    • Tabb, D.L.1    Huang, Y.2    Wysocki, V.H.3    Yates III, J.R.4
  • 11
    • 38649126540 scopus 로고    scopus 로고
    • What's driving false discovery rates
    • Tabb, D. L. What's driving false discovery rates. J. Proteome Res. 2008, 7 (1), 45-46.
    • (2008) J. Proteome Res. , vol.7 , Issue.1 , pp. 45-46
    • Tabb, D.L.1
  • 12
    • 34147173417 scopus 로고    scopus 로고
    • On the proper use of mass accuracy in proteomics
    • DOI 10.1074/mcp.M600380-MCP200
    • Zubarev, R.; Mann, M. On the proper use of mass accuracy in proteomics. Mol. Cell. Proteomics 2007, 6 (3), 377-381. (Pubitemid 46554535)
    • (2007) Molecular and Cellular Proteomics , vol.6 , Issue.3 , pp. 377-381
    • Zubarev, R.1    Mann, M.2
  • 14
    • 61849140098 scopus 로고    scopus 로고
    • Mass measurement errors of Fourier-transform mass spectrometry (FTMS): Distribution, recalibration, and application
    • Zhang, J.; Ma, J.; Dou, L.; Wu, S.; Qian, X.; Xie, H.; Zhu, Y.; He, F. Mass measurement errors of Fourier-transform mass spectrometry (FTMS): distribution, recalibration, and application. J. Proteome Res. 2009, 8 (2), 849-859.
    • (2009) J. Proteome Res. , vol.8 , Issue.2 , pp. 849-859
    • Zhang, J.1    Ma, J.2    Dou, L.3    Wu, S.4    Qian, X.5    Xie, H.6    Zhu, Y.7    He, F.8
  • 15
    • 56449113539 scopus 로고    scopus 로고
    • Characterization of strategies for obtaining confident identifications in bottom-up proteomics measurements using hybrid FTMS instruments
    • Tolmachev, A. V.; Monroe, M. E.; Purvine, S. O.; Moore, R. J.; Jaitly, N.; Adkins, J. N.; Anderson, G. A.; Smith, R. D. Characterization of strategies for obtaining confident identifications in bottom-up proteomics measurements using hybrid FTMS instruments. Anal. Chem. 2008, 80 (22), 8514-8525.
    • (2008) Anal. Chem. , vol.80 , Issue.22 , pp. 8514-8525
    • Tolmachev, A.V.1    Monroe, M.E.2    Purvine, S.O.3    Moore, R.J.4    Jaitly, N.5    Adkins, J.N.6    Anderson, G.A.7    Smith, R.D.8
  • 16
    • 41449095461 scopus 로고    scopus 로고
    • Improving protein identification sensitivity by combining MS and MS/MS information for shotgun proteomics using LTQ-Orbitrap high mass accuracy data
    • Lu, B.; Motoyama, A.; Ruse, C.; Venable, J.; Yates, J. R., III. Improving protein identification sensitivity by combining MS and MS/MS information for shotgun proteomics using LTQ-Orbitrap high mass accuracy data. Anal. Chem. 2008, 80 (6), 2018-2025.
    • (2008) Anal. Chem. , vol.80 , Issue.6 , pp. 2018-2025
    • Lu, B.1    Motoyama, A.2    Ruse, C.3    Venable, J.4    Yates III, J.R.5
  • 17
    • 53049093468 scopus 로고    scopus 로고
    • Enhancing peptide identification confidence by combining search methods
    • Alves, G.; Wu, W. W.; Wang, G.; Shen, R. F.; Yu, Y. K. Enhancing peptide identification confidence by combining search methods. J. Proteome Res. 2008, 7 (8), 3102-3113.
    • (2008) J. Proteome Res. , vol.7 , Issue.8 , pp. 3102-3113
    • Alves, G.1    Wu, W.W.2    Wang, G.3    Shen, R.F.4    Yu, Y.K.5
  • 18
    • 58149375925 scopus 로고    scopus 로고
    • Adaptive discriminant function analysis and reranking of MS/MS database search results for improved peptide identification in shotgun proteomics
    • Ding, Y.; Choi, H.; Nesvizhskii, A. I. Adaptive discriminant function analysis and reranking of MS/MS database search results for improved peptide identification in shotgun proteomics. J. Proteome Res. 2008, 7 (11), 4878-4889.
    • (2008) J. Proteome Res. , vol.7 , Issue.11 , pp. 4878-4889
    • Ding, Y.1    Choi, H.2    Nesvizhskii, A.I.3
  • 19
    • 34249094851 scopus 로고    scopus 로고
    • A mass accuracy sensitive probability based scoring algorithm for database searching of tandem mass spectrometry data
    • Xu, H.; Freitas, M. A. A mass accuracy sensitive probability based scoring algorithm for database searching of tandem mass spectrometry data. BMC Bioinf. 2007, 8, 133.
    • (2007) BMC Bioinf. , vol.8 , pp. 133
    • Xu, H.1    Freitas, M.A.2
  • 20
    • 52049095126 scopus 로고    scopus 로고
    • SALAMI (Spectrum ALignments using high Accuracy Mass and hIgh sensitivity data): How to make the best out of hybrid MS/MS data
    • Monigatti, F.; Steen, H. SALAMI (Spectrum ALignments using high Accuracy Mass and hIgh sensitivity data): how to make the best out of hybrid MS/MS data. J. Proteome Res. 2008, 7 (5), 1984-1993.
    • (2008) J. Proteome Res. , vol.7 , Issue.5 , pp. 1984-1993
    • Monigatti, F.1    Steen, H.2
  • 21
    • 58149401887 scopus 로고    scopus 로고
    • The rate of false positive sequence matches of peptides profiled by MALDI MS and identified by MS/MS
    • Stoop, M. P.; Lamers, R. J.; Burgers, P. C.; Sillevis Smitt, P. A.; Hintzen, R. Q.; Luider, T. M. The rate of false positive sequence matches of peptides profiled by MALDI MS and identified by MS/MS. J. Proteome Res. 2008, 7 (11), 4841-4847.
    • (2008) J. Proteome Res. , vol.7 , Issue.11 , pp. 4841-4847
    • Stoop, M.P.1    Lamers, R.J.2    Burgers, P.C.3    Sillevis Smitt, P.A.4    Hintzen, R.Q.5    Luider, T.M.6
  • 22
    • 17044391487 scopus 로고    scopus 로고
    • Mapping the membrane proteome of Corynebacterium glutamicum
    • DOI 10.1002/pmic.200400993
    • Schluesener, D.; Fischer, F.; Kruip, J.; Rogner, M.; Poetsch, A. Mapping the membrane proteome of Corynebacterium glutamicum. Proteomics 2005, 5 (5), 1317-1330. (Pubitemid 40503049)
    • (2005) Proteomics , vol.5 , Issue.5 , pp. 1317-1330
    • Schluesener, D.1    Fischer, F.2    Kruip, J.3    Rogner, M.4    Poetsch, A.5
  • 23
    • 0033434080 scopus 로고    scopus 로고
    • Probability-based protein identification by searching sequence databases using mass spectrometry data
    • Perkins, D. N.; Pappin, D. J.; Creasy, D. M.; Cottrell, J. S. Probability-based protein identification by searching sequence databases using mass spectrometry data. Electrophoresis 1999, 20 (18), 3551-3567.
    • (1999) Electrophoresis , vol.20 , Issue.18 , pp. 3551-3567
    • Perkins, D.N.1    Pappin, D.J.2    Creasy, D.M.3    Cottrell, J.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.