메뉴 건너뛰기




Volumn 54, Issue 20, 2009, Pages 6135-6150

Modeling silicon diode energy response factors for use in therapeutic photon beams

Author keywords

[No Author keywords available]

Indexed keywords

ALTERNATIVE METHODS; ARBITRARY POSITIONS; BIPARTITION; CAVITY THEORY; DEPTH VARIATION; DETECTOR RESPONSE; ELECTRON EQUILIBRIUM; ELECTRON SPECTRUM; ENERGY DEPENDENT; ENERGY RESPONSE FACTOR; ENERGY VARIATIONS; FLUENCES; HIGH DOSE; HIGH-ENERGY COMPONENTS; IN-FIELD; LOW ENERGIES; LOW ENERGY PHOTONS; PHOTON BEAMS; PHOTON FIELDS; PHOTON SPECTRA; PRIMARY BEAMS; PRIMARY ELECTRONS; PRIMARY PHOTONS; RESPONSE FACTOR; RESPONSE FUNCTIONS; SCATTER FACTOR; SCATTERED PHOTONS; SILICON DIODES; SPATIAL RESOLUTION;

EID: 70449099423     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/54/20/007     Document Type: Article
Times cited : (28)

References (21)
  • 1
    • 58149210333 scopus 로고
    • PENELOPE: An algorithm for Monte Carlo simulation of the penetration and energy loss of electrons and positrons in matter
    • Baró J, Sempau J, Fernndez-Varea J M and Salvat F 1995 PENELOPE: an algorithm for Monte Carlo simulation of the penetration and energy loss of electrons and positrons in matter Nucl. Instrum. Methods Phys. Res. B 100 16
    • (1995) Nucl. Instrum. Methods Phys. Res. , vol.100 , Issue.1 , pp. 31
    • Baró, J.1    Sempau, J.2    Fernndez-Varea, J.M.3    Salvat, F.4
  • 2
    • 0031120968 scopus 로고    scopus 로고
    • ROOT-an object oriented data analysis framework
    • Brun R and Rademakers F 1997 ROOT-an object oriented data analysis framework Proc. AIHENP '96 Workshop (Lausanne, September 1996) pp 81-6
    • (1997) Proc. AIHENP '96 Workshop , pp. 81-86
    • Brun, R.1    Rademakers, F.2
  • 4
    • 51849129582 scopus 로고    scopus 로고
    • Fast modelling of spectra and stopping-power ratios using differentiated fluence pencil kernels
    • Eklund K and Ahnesjö A 2008 Fast modelling of spectra and stopping-power ratios using differentiated fluence pencil kernels Phys. Med. Biol. 53 4231-47
    • (2008) Phys. Med. Biol. , vol.53 , Issue.16 , pp. 4231-4247
    • Eklund, K.1    Ahnesjö, A.2
  • 6
    • 33645009141 scopus 로고    scopus 로고
    • Dosimetric characteristics of a new unshielded silicon diode and its application in clinical photon and electron beams
    • Griessbach I, Lapp M, Bohsung J, Gademann G and Harder D 2005 Dosimetric characteristics of a new unshielded silicon diode and its application in clinical photon and electron beams Med. Phys. 32 3750-4
    • (2005) Med. Phys. , vol.32 , Issue.12 , pp. 3750-3754
    • Griessbach, I.1    Lapp, M.2    Bohsung, J.3    Gademann, G.4    Harder, D.5
  • 7
    • 84907110099 scopus 로고
    • Radiation damage induced dose rate non-linearity in an n-type silicon detector
    • Grusell E and Rikner G 1984 Radiation damage induced dose rate non-linearity in an n-type silicon detector Acta Radiol. 23 465-9
    • (1984) Acta Radiol. , vol.23 , pp. 465-469
    • Grusell, E.1    Rikner, G.2
  • 8
    • 0027212572 scopus 로고
    • Linearity with dose rate of low resistivity p-type silicon semiconductor detectors
    • Grusell E and Rikner G 1993 Linearity with dose rate of low resistivity p-type silicon semiconductor detectors Phys. Med. Biol. 38 785-92
    • (1993) Phys. Med. Biol. , vol.38 , Issue.6 , pp. 785-792
    • Grusell, E.1    Rikner, G.2
  • 9
    • 0036852599 scopus 로고    scopus 로고
    • Evaluation and characterization of parallel plate microchamber's functionalities in small beam dosimetry
    • Lee H R, Pankuch M, Chu J C and Spokas J J 2002 Evaluation and characterization of parallel plate microchamber's functionalities in small beam dosimetry Med. Phys. 29 2489-96
    • (2002) Med. Phys. , vol.29 , Issue.11 , pp. 2489-2496
    • Lee, H.R.1    Pankuch, M.2    Chu, J.C.3    Spokas, J.J.4
  • 10
    • 84907105761 scopus 로고
    • 60Co and 8 and 16 MV roentgen radiation
    • 60Co and 8 and 16 MV roentgen radiation Acta Radiol. 24 205-8
    • (1985) Acta Radiol. , vol.24 , pp. 205-208
    • Rikner, G.1
  • 11
    • 0021043262 scopus 로고
    • Effects of radiation damage on p-type silicon detectors
    • Rikner G and Grusell E 1983 Effects of radiation damage on p-type silicon detectors Phys. Med. Biol. 28 1261-7
    • (1983) Phys. Med. Biol. , vol.28 , Issue.11 , pp. 1261-1267
    • Rikner, G.1    Grusell, E.2
  • 12
    • 84907106851 scopus 로고
    • Selective shielding of a p-Si detector for quality independence
    • Rikner G and Grusell E 1985 Selective shielding of a p-Si detector for quality independence Acta Radiol. 24 65-9
    • (1985) Acta Radiol. , vol.24 , pp. 65-69
    • Rikner, G.1    Grusell, E.2
  • 13
    • 0023622870 scopus 로고
    • General specifications for silicon semiconductors for use in radiation dosimetry
    • Rikner G and Grusell E 1987 General specifications for silicon semiconductors for use in radiation dosimetry Phys. Med. Biol. 32 1109-17
    • (1987) Phys. Med. Biol. , vol.32 , Issue.9 , pp. 1109-1117
    • Rikner, G.1    Grusell, E.2
  • 16
    • 34447336432 scopus 로고    scopus 로고
    • Measurement of output factors for small photon beams
    • Sauer O A and Wilbert J 2007 Measurement of output factors for small photon beams Med. Phys. 34 1983-8
    • (2007) Med. Phys. , vol.34 , Issue.6 , pp. 1983-1988
    • Sauer, O.A.1    Wilbert, J.2
  • 17
    • 0022113394 scopus 로고
    • Bremsstrahlung spectra from electron interactions with screened atomic nuclei and orbital electrons
    • Seltzer S M and Berger M J 1985 Bremsstrahlung spectra from electron interactions with screened atomic nuclei and orbital electrons Nucl. Instrum. Methods Phys. Res. B 12 95-134
    • (1985) Nucl. Instrum. Methods Phys. Res. , vol.12 , Issue.1 , pp. 95-134
    • Seltzer, S.M.1    Berger, M.J.2
  • 18
    • 27744565298 scopus 로고
    • Bremsstrahlung energy spectra from electrons with kinetic energy 1 keV-10 GeV incident on screened nuclei and orbital electrons of neutral atoms with Z = 1 - 100*
    • Seltzer S M and Berger M J 1986 Bremsstrahlung energy spectra from electrons with kinetic energy 1 keV-10 GeV incident on screened nuclei and orbital electrons of neutral atoms with Z = 1 - 100* At. Data Nucl. Data Tables 35 345-418
    • (1986) At. Data Nucl. Data Tables , vol.35 , Issue.3 , pp. 345-418
    • Seltzer, S.M.1    Berger, M.J.2
  • 19
    • 0036130665 scopus 로고    scopus 로고
    • Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code
    • Sheikh-Bagheri D and Rogers D W 2002 Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code Med. Phys. 29 391-402
    • (2002) Med. Phys. , vol.29 , Issue.3 , pp. 391-402
    • Sheikh-Bagheri, D.1    Rogers, D.W.2
  • 20
    • 34247580941 scopus 로고    scopus 로고
    • Monte Carlo study of si diode response in electron beams
    • Wang L L and Rogers D W 2007 Monte Carlo study of si diode response in electron beams Med. Phys. 34 1734-42
    • (2007) Med. Phys. , vol.34 , Issue.5 , pp. 1734-1742
    • Wang, L.L.1    Rogers, D.W.2
  • 21
    • 4444263965 scopus 로고    scopus 로고
    • Response corrections for solid-state detectors in megavoltage photon dosimetry
    • Yin Z, Hugtenburg R P and Beddoe A H 2004 Response corrections for solid-state detectors in megavoltage photon dosimetry Phys. Med. Biol. 49 3691-702
    • (2004) Phys. Med. Biol. , vol.49 , Issue.16 , pp. 3691-3702
    • Yin, Z.1    Hugtenburg, R.P.2    Beddoe, A.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.