메뉴 건너뛰기




Volumn 49, Issue 16, 2004, Pages 3691-3702

Response corrections for solid-state detectors in megavoltage photon dosimetry

Author keywords

[No Author keywords available]

Indexed keywords

DOSIMETRY; PHOTONS; RADIATION DETECTORS; RADIATION SHIELDING; SURGERY;

EID: 4444263965     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/49/16/015     Document Type: Article
Times cited : (60)

References (11)
  • 1
    • 0013956540 scopus 로고
    • A general theory of cavity ionisation
    • Burlin T E 1966 A general theory of cavity ionisation Br. J. Radiol. 39 727-34
    • (1966) Br. J. Radiol. , vol.39 , pp. 727-734
    • Burlin, T.E.1
  • 2
    • 0028049726 scopus 로고
    • Dose rate dependence of a PTW diamond detector in the dosimetry of a 6 MV photon beam
    • Hoban P W, Heydarian M, Beckham W A and Beddoe A H 1994 Dose rate dependence of a PTW diamond detector in the dosimetry of a 6 MV photon beam Phys. Med. Biol. 39 1219-29
    • (1994) Phys. Med. Biol. , vol.39 , pp. 1219-1229
    • Hoban, P.W.1    Heydarian, M.2    Beckham, W.A.3    Beddoe, A.H.4
  • 3
    • 0003982205 scopus 로고
    • Stopping Powers for Electrons and Positrons
    • ICRU Washington, DC
    • ICRU 1984 Stopping Powers for Electrons and Positrons ICRU Report 37 Washington, DC
    • (1984) ICRU Report 37
  • 5
    • 0003954913 scopus 로고
    • 2nd edn (Baltimore, MD: Williams & Wilkins) chapter 10
    • Khan F M 1994 The Physics of Radiation Therapy 2nd edn (Baltimore, MD: Williams & Wilkins) chapter 10
    • (1994) The Physics of Radiation Therapy
    • Khan, F.M.1
  • 6
    • 0030837107 scopus 로고    scopus 로고
    • An EGS4 Monte Carlo examination of general cavity theory
    • Mobit P N, Nahum A E and Mayles P 1997 An EGS4 Monte Carlo examination of general cavity theory Phys. Med. Biol. 42 1319-34
    • (1997) Phys. Med. Biol. , vol.42 , pp. 1319-1334
    • Mobit, P.N.1    Nahum, A.E.2    Mayles, P.3
  • 7
    • 0032692443 scopus 로고    scopus 로고
    • A Monte Carlo comparison of the response of the PTW-diamond and the TL-diamond detectors in megavoltage phanton beams
    • Mobit P N and Sandison G A 1999 A Monte Carlo comparison of the response of the PTW-diamond and the TL-diamond detectors in megavoltage phanton beams Med. Phys. 26 2503-7
    • (1999) Med. Phys. , vol.26 , pp. 2503-2507
    • Mobit, P.N.1    Sandison, G.A.2
  • 8
    • 0021849353 scopus 로고
    • Energy and angular distribution of photons from medical linear accelerators
    • Mohan R, Chui C and Lidofsky L 1985 Energy and angular distribution of photons from medical linear accelerators Med. Phys. 12 592-7
    • (1985) Med. Phys. , vol.12 , pp. 592-597
    • Mohan, R.1    Chui, C.2    Lidofsky, L.3
  • 9
    • 0017871253 scopus 로고
    • Water/air mass stopping power ratios for photon and electron beams
    • Nahum A E 1978 Water/air mass stopping power ratios for photon and electron beams Phys. Med. Biol. 23 24-38
    • (1978) Phys. Med. Biol. , vol.23 , pp. 24-38
    • Nahum, A.E.1
  • 10
    • 0036393221 scopus 로고    scopus 로고
    • Response of silicon diode dosemeters to scattered radiation from megavoltage photon beams
    • Yin Z, Hugtenburg R P and Beddoe A H 2002 Response of silicon diode dosemeters to scattered radiation from megavoltage photon beams Radiat. Prot. Dosim. 101 415-8
    • (2002) Radiat. Prot. Dosim. , vol.101 , pp. 415-418
    • Yin, Z.1    Hugtenburg, R.P.2    Beddoe, A.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.