메뉴 건너뛰기




Volumn 32, Issue 12, 2005, Pages 3750-3754

Dosimetric characteristics of a new unshielded silicon diode and its application in clinical photon and electron beams

Author keywords

Electron dosimetry; Photon dosimetry; Silicon diode; Small field dosimetry

Indexed keywords

DOSIMETRY; ELECTRON BEAMS; ELECTRON SCATTERING; PHOTOELECTRONS; PHOTONS; SILICON;

EID: 33645009141     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2124547     Document Type: Article
Times cited : (113)

References (14)
  • 1
    • 0037035943 scopus 로고    scopus 로고
    • Investigation of photon beam output factors for conformal radiation therapy - Monte Carlo Simulations and measurements
    • F. Haryanto, M. Fippel, W. Laub, O. Dohm, and F. Nüsslin, " Investigation of photon beam output factors for conformal radiation therapy - Monte Carlo Simulations and measurements, " Phys. Med. Biol. 47, 133-144 (2002).
    • (2002) Phys. Med. Biol. , vol.47 , pp. 133-144
    • Haryanto, F.1
  • 2
    • 0036703573 scopus 로고    scopus 로고
    • Dosimetric characteristics of Novalis shaped beam surgery unit
    • F.-F. Yin, J. Zhu, H. Yan, H. Gaun, R. Hammouind, S. Ryu, and J. H. Kim, " Dosimetric characteristics of Novalis shaped beam surgery unit, " Med. Phys. 29, 1729-1738 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 1729-1738
    • Yin, F.-F.1
  • 3
    • 0036852599 scopus 로고    scopus 로고
    • Evaluation and characterization of parallel plate microchamber's functionalities in small beam dosimetry
    • H.-R. Lee, M. Pankuch, and J. C. Chu, " Evaluation and characterization of parallel plate microchamber's functionalities in small beam dosimetry, " Med. Phys. 29, 2489-2496 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 2489-2496
    • Lee, H.-R.1
  • 4
    • 0037323020 scopus 로고    scopus 로고
    • Comparison of ionization chambers of various volumes for IMRT absolute dose verification
    • L. B. Leybovich, A. Sethi, and N. Dogan, " Comparison of ionization chambers of various volumes for IMRT absolute dose verification, " Med. Phys. 30, 119-143 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 119-143
    • Leybovich, L.B.1
  • 5
    • 0037323117 scopus 로고    scopus 로고
    • Physical aspects of dynamic stereotactic radiosurgery with very small photon beams (1.5 and
    • K. A. Peskalev, J. P. Seuntjens, H. J. Patrocinio, and E. B. Podgorsak, " Physical aspects of dynamic stereotactic radiosurgery with very small photon beams (1.5 and 3mm diameter), " Med. Phys. 30, 111-118 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 111-118
    • Peskalev, K.A.1
  • 6
    • 33645450184 scopus 로고    scopus 로고
    • Basis-daten zum pencil-beam-Dosis-Algorithmus für Brainlab m3-microMLC - Ein Vergleich der Dosimetrieverfahren
    • I. Griessbach, M. Raupach, J. Scheermann, and G. Gademann, " Basis-daten zum pencil-beam-Dosis-Algorithmus für Brainlab m3-microMLC - ein Vergleich der Dosimetrieverfahren, " Strahlenther. Onkol. 178, 50 (2002).
    • (2002) Strahlenther. Onkol. , vol.178 , pp. 50
    • Griessbach, I.1
  • 7
    • 85027240845 scopus 로고    scopus 로고
    • Neue hochauflösende PTW-Dosimetrie-Diode 60012
    • edited by, W. Semmler, and, L. Schad, (ISBN: 3-925218-77-7).
    • I. Griessbach, M. Lapp, J. Bohsung, G. Gademann, E. Schüle, and D. Harder, " Neue hochauflösende PTW-Dosimetrie-Diode 60012, " Medizinische Physik 2003, edited by, W. Semmler, and, L. Schad, 2003, pp. 112-113 (ISBN: 3-925218-77-7).
    • (2003) Medizinische Physik 2003 , pp. 112-113
    • Griessbach, I.1    Lapp, M.2    Bohsung, J.3    Gademann, G.4    Schüle, E.5    Harder, D.6
  • 8
    • 4444263965 scopus 로고    scopus 로고
    • Response corrections for solid-state detectors in megavoltage photon dosimetry
    • Z. Yin, R. P. Hugtenburg, and A. H. Beddoe, " Response corrections for solid-state detectors in megavoltage photon dosimetry, " Phys. Med. Biol. 49, 3691-3702 (2004).
    • (2004) Phys. Med. Biol. , vol.49 , pp. 3691-3702
    • Yin, Z.1
  • 9
    • 84907106851 scopus 로고
    • Selective shielding of a
    • G. Rikner and E. Grusell, " Selective shielding of a p-Si detector for quality independence, " Acta Radiol. Oncol. 24, 65-69 (1985).
    • (1985) Acta Radiol. Oncol. , vol.24 , pp. 65-69
    • Rikner, G.1
  • 11
    • 85027235195 scopus 로고    scopus 로고
    • Messungen zur Systematik der Wandeffekte von Fricke- und Thermolumineszenz-Dosimetern bei Photonen- und Elektronenstrahl- ung
    • edited by, K. Welker, and, K. Zink, (ISBN: 3-89391-960-0).
    • I. Griessbach, G. Gademann, M.A. Mandour, and D. Harder, "Messungen zur Systematik der Wandeffekte von Fricke- und Thermolumineszenz-Dosimetern bei Photonen- und Elektronenstrahl- ung," Medizinische Physik, edited by, K. Welker, and, K. Zink,, 2001, pp. 185-186 (ISBN: 3-89391-960-0).
    • (2001) Medizinische Physik , pp. 185-186
    • Griessbach, I.1    Gademann, G.2    Mandour, M.A.3    Harder, D.4    Zink, K.5
  • 12
    • 85027220403 scopus 로고    scopus 로고
    • Korrekte Messung von Outputfaktoren und Dosisprofilen mit einem 2D-Array," Medizinische Physik
    • edited by, H. Mandl, (ISBN: 3-925218-75-0).
    • B. Poppe, A. Djouguela, R. Kollhoff, A. Rubach, and D. Harder, "Korrekte Messung von Outputfaktoren und Dosisprofilen mit einem 2D-Array," Medizinische Physik 2002, edited by, H. Mandl, (ISBN: 3-925218-75-0).
    • Medizinische Physik 2002
    • Poppe, B.1    Djouguela, A.2    Kollhoff, R.3    Rubach, A.4    Harder, D.5    Mandl, H.6
  • 13
    • 4444287900 scopus 로고    scopus 로고
    • Spectra of scattered photons in large absorbers and their importance for the values of radiation weighting factor
    • R, " Radiat. Prot. Dosim. 109, 291-295 (2004).
    • (2004) Radiat. Prot. Dosim. , vol.109 , pp. 291-295
    • Harder, D.1
  • 14
    • 0034065594 scopus 로고    scopus 로고
    • Comparative dosimetry in narrow high-energy photon beams
    • W. Westermark, J. Arndt, B. Nilsson, and A. Brahme, " Comparative dosimetry in narrow high-energy photon beams, " Phys. Med. Biol. 45, 685-702 (2000).
    • (2000) Phys. Med. Biol. , vol.45 , pp. 685-702
    • Westermark, W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.