메뉴 건너뛰기




Volumn 18, Issue 10, 2009, Pages

On the applicability of fluidic flexible matrix composite variable impedance materials for prosthetic and orthotic devices

Author keywords

[No Author keywords available]

Indexed keywords

ACTIVE IMPEDANCE; FLEXIBLE MATRIX COMPOSITE; FOOT ORTHOSE; HIGH BULK MODULUS; HIGH PERFORMANCE COMPOSITES; JOINT CONTROL; LOAD TRANSFER; MATERIAL SYSTEMS; NEW MATERIAL; ORDERS OF MAGNITUDE; ORTHOTIC DEVICES; PRELIMINARY ANALYSIS; PROSTHETIC SOCKETS; VALVE CONTROL; VARIABLE IMPEDANCE; VARIABLE MODULI;

EID: 70350664415     PISSN: 09641726     EISSN: 1361665X     Source Type: Journal    
DOI: 10.1088/0964-1726/18/10/104023     Document Type: Article
Times cited : (13)

References (33)
  • 1
    • 20444449647 scopus 로고    scopus 로고
    • Changes in interface pressures and shear stresses over time on trans-tibial amputee subjects ambulating with prosthetic limbs: Comparison of diurnal and six-month differences
    • Sanders J E, Zachariah S G, Jacobsen A K and Fergason J R 2005 Changes in interface pressures and shear stresses over time on trans-tibial amputee subjects ambulating with prosthetic limbs: comparison of diurnal and six-month differences J. Biomech. 38 1566-73
    • (2005) J. Biomech. , vol.38 , Issue.8 , pp. 1566-1573
    • Sanders, J.E.1    Zachariah, S.G.2    Jacobsen, A.K.3    Fergason, J.R.4
  • 2
    • 3242655551 scopus 로고    scopus 로고
    • Load transfer mechanics between trans-tibial prosthetic socket and residual limb-dynamic effects
    • Jia X, Zhang M and Lee W C C 2004 Load transfer mechanics between trans-tibial prosthetic socket and residual limb-dynamic effects J. Biomech. 37 1371-7
    • (2004) J. Biomech. , vol.37 , Issue.9 , pp. 1371-1377
    • Jia, X.1    Zhang, M.2    Lee, W.C.C.3
  • 3
    • 33750619553 scopus 로고    scopus 로고
    • Pressure distribution at the stump/socket interface in transtibial amputees during walking on stairs, slope and non-flat road
    • Dou P, Jia X, Suo S, Wang R and Zhang M 2006 Pressure distribution at the stump/socket interface in transtibial amputees during walking on stairs, slope and non-flat road Clin. Biomech. 21 1067-73
    • (2006) Clin. Biomech. , vol.21 , Issue.10 , pp. 1067-1073
    • Dou, P.1    Jia, X.2    Suo, S.3    Wang, R.4    Zhang, M.5
  • 5
    • 1542723639 scopus 로고    scopus 로고
    • Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait
    • Blaya J A and Herr H 2004 Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait IEEE Trans. Neural Syst. Rehabil. Eng. 12 24-31 (see also IEEE Trans. Rehabil. Eng.)
    • (2004) IEEE Trans. Neural Syst. Rehabil. Eng. , vol.12 , Issue.1 , pp. 24-31
    • Blaya, J.A.1    Herr, H.2
  • 6
    • 0036586886 scopus 로고    scopus 로고
    • Presentation highlights: Prosthetic and orthotic limbs
    • Herr H 2002 Presentation highlights: prosthetic and orthotic limbs J. Rehabil. Res. Dev. 39 11-2
    • (2002) J. Rehabil. Res. Dev. , vol.39 , pp. 11-12
    • Herr, H.1
  • 8
    • 18744416003 scopus 로고    scopus 로고
    • An ankle-foot orthosis powered by artificial pneumatic muscles
    • Ferris D P, Czerniecki J M and Hannaford B 2005 An ankle-foot orthosis powered by artificial pneumatic muscles J. Appl. Biomech. 21 189
    • (2005) J. Appl. Biomech. , vol.21 , pp. 189
    • Ferris, D.P.1    Czerniecki, J.M.2    Hannaford, B.3
  • 9
    • 0003326901 scopus 로고    scopus 로고
    • Novel semi-active variable stiffness tuned mass damper with real time retuning capability
    • Nagarajaiah S and Varadarajan N 2000 Novel semi-active variable stiffness tuned mass damper with real time retuning capability Proc. 14th Engineering Mechanics Conf. (Austin, TX)
    • (2000) Proc. 14th Engineering Mechanics Conf.
    • Nagarajaiah, S.1    Varadarajan, N.2
  • 10
    • 0026173706 scopus 로고
    • Vibration suppression by variable-stiffness members
    • Onoda J, Watanabe N, Endo T and Tamaoki H 1991 Vibration suppression by variable-stiffness members AIAA J. 29 977-83
    • (1991) AIAA J. , vol.29 , Issue.6 , pp. 977-983
    • Onoda, J.1    Watanabe, N.2    Endo, T.3    Tamaoki, H.4
  • 11
    • 8844251564 scopus 로고    scopus 로고
    • Smart fabric adaptive stiffness for active vibration absorbers
    • Albanese A-M and Cunefare K A 2004 Smart fabric adaptive stiffness for active vibration absorbers Proc. SPIE-Int. Soc. Opt. Eng. 5383 490-7
    • (2004) Proc. SPIE-Int. Soc. Opt. Eng. , vol.5383 , Issue.1 , pp. 490-497
    • Albanese, A.-M.1    Cunefare, K.A.2
  • 16
    • 77957763401 scopus 로고    scopus 로고
    • Sliding mode control of variable modulus structures based upon fluidic flexible matrix composites
    • Philen M 2008 Sliding mode control of variable modulus structures based upon fluidic flexible matrix composites 16th AIAA/ASME/AHS Adaptive Structures Conf. (Seattle, WA)
    • (2008) 16th AIAA/ASME/AHS Adaptive Structures Conf.
    • Philen, M.1
  • 21
    • 0037207197 scopus 로고    scopus 로고
    • Chemically cross-linked polycyclooctene: Synthesis, characterization, and shape memory behavior
    • Liu C, Chun S B, Mather P T, Zheng L, Haley E H and Coughlin E B 2002 Chemically cross-linked polycyclooctene: synthesis, characterization, and shape memory behavior Macromolecules 35 9868-74
    • (2002) Macromolecules , vol.35 , Issue.27 , pp. 9868-9874
    • Liu, C.1    Chun, S.B.2    Mather, P.T.3    Zheng, L.4    Haley, E.H.5    Coughlin, E.B.6
  • 22
    • 0030218573 scopus 로고    scopus 로고
    • Thermomechanical properties in a thin film of shape memory polymer of polyurethane series
    • Tobushi H, Hara H, Yamada E and Hayashi S 1996 Thermomechanical properties in a thin film of shape memory polymer of polyurethane series Smart Mater. Struct. 5 483-91 (Pubitemid 126689625)
    • (1996) Smart Materials and Structures , vol.5 , Issue.4 , pp. 483-491
    • Tobushi, H.1    Hara, H.2    Yamada, E.3    Hayashi, S.4
  • 24
    • 25444464663 scopus 로고    scopus 로고
    • Extended frequency bandwidth and electrical resonance tuning in hybrid Terfenol-D/PMN-PT transducers in mechanical series configuration
    • Downey P R and Dapino M J 2005 Extended frequency bandwidth and electrical resonance tuning in hybrid Terfenol-D/PMN-PT transducers in mechanical series configuration J. Intell. Mater. Syst. Struct. 16 757-72
    • (2005) J. Intell. Mater. Syst. Struct. , vol.16 , Issue.9 , pp. 757-772
    • Downey, P.R.1    Dapino, M.J.2
  • 25
    • 0034292266 scopus 로고    scopus 로고
    • Electromechanical properties of a humido-sensitive conducting polymer film
    • Okuzaki H and Funasaka K 2000 Electromechanical properties of a humido-sensitive conducting polymer film Macromolecules 33 8307-11
    • (2000) Macromolecules , vol.33 , Issue.22 , pp. 8307-8311
    • Okuzaki, H.1    Funasaka, K.2
  • 26
    • 0000424267 scopus 로고    scopus 로고
    • Model of magnetorheological elastomers
    • Davis L C 1999 Model of magnetorheological elastomers J. Appl. Phys. 85 3348-51
    • (1999) J. Appl. Phys. , vol.85 , Issue.6 , pp. 3348-3351
    • Davis, L.C.1
  • 30
    • 0030447524 scopus 로고    scopus 로고
    • Joint kinetics in unilateral below-knee amputee patients during running
    • Sanderson D J and Martin P E 1996 Joint kinetics in unilateral below-knee amputee patients during running Arch. Phys. Med. Rehabil. 77 1279-85
    • (1996) Arch. Phys. Med. Rehabil. , vol.77 , Issue.12 , pp. 1279-1285
    • Sanderson, D.J.1    Martin, P.E.2
  • 31
    • 0030169297 scopus 로고    scopus 로고
    • Clinical biomechanics award paper 1995 lower extremity joint loading during impact in running
    • Cole G K, Nigg B M, van den Bogert A J and Gerritsen K G M 1996 Clinical biomechanics award paper 1995 lower extremity joint loading during impact in running Clin. Biomech. 11 181-93
    • (1996) Clin. Biomech. , vol.11 , Issue.4 , pp. 181-193
    • Cole, G.K.1    Nigg, B.M.2    Van Den Bogert, A.J.3    Gerritsen, K.G.M.4
  • 32
    • 31144446701 scopus 로고    scopus 로고
    • The quasi-static response of compliant prosthetic sockets for transtibial amputees using finite element methods
    • Faustini M C, Neptune R R and Crawford R H 2006 The quasi-static response of compliant prosthetic sockets for transtibial amputees using finite element methods Med. Eng. Phys. 28 114-21
    • (2006) Med. Eng. Phys. , vol.28 , Issue.2 , pp. 114-121
    • Faustini, M.C.1    Neptune, R.R.2    Crawford, R.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.