2
-
-
0032122242
-
Finite element modeling of residual lower-limb in a prosthetic socket: A survey of the development in the first decade
-
M. Zhang, A. Mak, and V.C. Roberts Finite element modeling of residual lower-limb in a prosthetic socket: a survey of the development in the first decade Med Eng Phys 20 1998 360 373
-
(1998)
Med Eng Phys
, vol.20
, pp. 360-373
-
-
Zhang, M.1
Mak, A.2
Roberts, V.C.3
-
3
-
-
0030482286
-
Interface mechanics in lower-limb external prosthetics: A review of finite element models
-
S. Zachariah, and J.E. Sanders Interface mechanics in lower-limb external prosthetics: a review of finite element models IEEE Trans Rehabil Eng 4 4 1996 288 302
-
(1996)
IEEE Trans Rehabil Eng
, vol.4
, Issue.4
, pp. 288-302
-
-
Zachariah, S.1
Sanders, J.E.2
-
4
-
-
0035099147
-
Comparison of computational analysis with clinical measurement of stresses on below-knee residual limb in a prosthetic socket
-
M. Zhang, and C. Roberts Comparison of computational analysis with clinical measurement of stresses on below-knee residual limb in a prosthetic socket Med Eng Phys 22 2000 607 612
-
(2000)
Med Eng Phys
, vol.22
, pp. 607-612
-
-
Zhang, M.1
Roberts, C.2
-
5
-
-
3242655551
-
Load transfer mechanics between trans-tibial prosthetic socket and residual limb-dynamic effects
-
X. Jia, M. Zhang, and W.C.C. Lee Load transfer mechanics between trans-tibial prosthetic socket and residual limb-dynamic effects J Biomech 37 2004 1371 1377
-
(2004)
J Biomech
, vol.37
, pp. 1371-1377
-
-
Jia, X.1
Zhang, M.2
Lee, W.C.C.3
-
6
-
-
0029411893
-
Development of a non linear finite element modeling of the below-knee prosthetic socket interface
-
M. Zhang, M. Lord, A.R. Turner-Smith, and V.C. Roberts Development of a non linear finite element modeling of the below-knee prosthetic socket interface Med Eng Phys 17 8 1995 559 566
-
(1995)
Med Eng Phys
, vol.17
, Issue.8
, pp. 559-566
-
-
Zhang, M.1
Lord, M.2
Turner-Smith, A.R.3
Roberts, V.C.4
-
7
-
-
4744352767
-
Finite element modeling of the contact interface between trans-tibial residual limb and prosthetic socket
-
W.C.C. Lee, M. Zhang, X. Jia, and J.M.T. Cheung Finite element modeling of the contact interface between trans-tibial residual limb and prosthetic socket Med Eng Phys 26 2004 655 662
-
(2004)
Med Eng Phys
, vol.26
, pp. 655-662
-
-
Lee, W.C.C.1
Zhang, M.2
Jia, X.3
Cheung, J.M.T.4
-
8
-
-
0030175670
-
Automated hexahedral mesh generation, from biomedical image data: Applications in limb prosthetics
-
S.G. Zachariah, J.E. Sanders, and G.M. Turkiyyah Automated hexahedral mesh generation, from biomedical image data: applications in limb prosthetics IEEE Trans Rehab Eng 4 2 1996 91 102
-
(1996)
IEEE Trans Rehab Eng
, vol.4
, Issue.2
, pp. 91-102
-
-
Zachariah, S.G.1
Sanders, J.E.2
Turkiyyah, G.M.3
-
9
-
-
0034071252
-
Finite element estimates of interface stress in the trans-tibial prosthesis using gap elements are different from those using automated contact
-
S.G. Zachariah, and J.E. Sanders Finite element estimates of interface stress in the trans-tibial prosthesis using gap elements are different from those using automated contact J Biomech 33 2000 895 899
-
(2000)
J Biomech
, vol.33
, pp. 895-899
-
-
Zachariah, S.G.1
Sanders, J.E.2
-
10
-
-
0003549879
-
-
Kluwer Academic Publishers
-
J.J. Beaman, J.W. Barlow, D.L. Bourell, R.H. Crawford, H.L. Marcus, and K.P. McAlea Solid freeform fabrication: a new direction in manufacturing 1997 Kluwer Academic Publishers
-
(1997)
Solid Freeform Fabrication: A New Direction in Manufacturing
-
-
Beaman, J.J.1
Barlow, J.W.2
Bourell, D.L.3
Crawford, R.H.4
Marcus, H.L.5
McAlea, K.P.6
-
11
-
-
0033198598
-
In vivo indentation of lower extremity limb soft tissues
-
M.B. Silver-Thorn In vivo indentation of lower extremity limb soft tissues IEEE Trans Rehabil Eng 7 3 1999 268 277
-
(1999)
IEEE Trans Rehabil Eng
, vol.7
, Issue.3
, pp. 268-277
-
-
Silver-Thorn, M.B.1
-
12
-
-
0036759842
-
Investigation of lower-limb tissue perfusion during loading
-
M.B. Silver-Thorn Investigation of lower-limb tissue perfusion during loading J Rehabil Res Dev 39 5 2002 597 608
-
(2002)
J Rehabil Res Dev
, vol.39
, Issue.5
, pp. 597-608
-
-
Silver-Thorn, M.B.1
-
13
-
-
0031649968
-
Conventional patellar-tendon-bearing (PTB) socket/stump interface dynamic pressure distributions recorded during the prosthetic stance phase of gait of a trans-tibial amputee
-
A.W.P. Buis, and P. Convery Conventional patellar-tendon-bearing (PTB) socket/stump interface dynamic pressure distributions recorded during the prosthetic stance phase of gait of a trans-tibial amputee Prosthet Orthot Int 22 1998 193 198
-
(1998)
Prosthet Orthot Int
, vol.22
, pp. 193-198
-
-
Buis, A.W.P.1
Convery, P.2
-
14
-
-
0032053296
-
Clinical investigation of the pressure and shear stress on the trans-tibial stump with a prosthesis
-
M. Zhang, A.R. Turner-Smith, A. Tanner, and V.C. Roberts Clinical investigation of the pressure and shear stress on the trans-tibial stump with a prosthesis Med Eng Phys 20 1998 188 198
-
(1998)
Med Eng Phys
, vol.20
, pp. 188-198
-
-
Zhang, M.1
Turner-Smith, A.R.2
Tanner, A.3
Roberts, V.C.4
-
16
-
-
0035039929
-
Modeling the interactions between a prosthetic socket, polyurethane liners and the residual limb in transtibial amputees using non-linear finite element analysis
-
Technical Papers of the ISA, vol. 408, Biomedical Sciences Instrumentation
-
Simpson G, Fisher C, Wright DK. Modeling the interactions between a prosthetic socket, polyurethane liners and the residual limb in transtibial amputees using non-linear finite element analysis. Technical Papers of the ISA, vol. 408, Biomedical Sciences Instrumentation, 38th Rocky Mountain Bioengineering Symposium, vol. 37; 2001. p. 343-7.
-
(2001)
38th Rocky Mountain Bioengineering Symposium
, vol.37
, pp. 343-7
-
-
Simpson, G.1
Fisher, C.2
Wright, D.K.3
|