메뉴 건너뛰기




Volumn 38, Issue 8, 2005, Pages 1566-1573

Changes in interface pressures and shear stresses over time on trans-tibial amputee subjects ambulating with prosthetic limbs: Comparison of diurnal and six-month differences

Author keywords

Artificial limb; Prosthesis; Skin

Indexed keywords

ARTIFICIAL ORGANS; BIOMECHANICS; CLINICAL LABORATORIES; IMPLANTS (SURGICAL); INTERFACES (MATERIALS); PRESSURE EFFECTS; SHEAR STRESS;

EID: 20444449647     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2004.08.008     Document Type: Article
Times cited : (87)

References (14)
  • 2
    • 0027475568 scopus 로고
    • Interstitial-lymphatic mechanisms in the control of extracellular fluid volume
    • K. Aukland, and R.K. Reed Interstitial-lymphatic mechanisms in the control of extracellular fluid volume Physiological Reviews 73 1993 1 78
    • (1993) Physiological Reviews , vol.73 , pp. 1-78
    • Aukland, K.1    Reed, R.K.2
  • 3
    • 0016558262 scopus 로고
    • A shorter pylon transducer for measurement of prosthetic forces and moments during amputee gait
    • N. Berme, P. Lawes, S. Solomonidis, and J.P. Paul A shorter pylon transducer for measurement of prosthetic forces and moments during amputee gait Engineering in Medicine 4 1976 6 8
    • (1976) Engineering in Medicine , vol.4 , pp. 6-8
    • Berme, N.1    Lawes, P.2    Solomonidis, S.3    Paul, J.P.4
  • 6
    • 0033096651 scopus 로고    scopus 로고
    • Computing the visual hull of solids of revolution
    • A. Laurentini Computing the visual hull of solids of revolution Pattern Recognition 32 1999 377 388
    • (1999) Pattern Recognition , vol.32 , pp. 377-388
    • Laurentini, A.1
  • 7
    • 0029043206 scopus 로고
    • Volumetric determinations with CAD/CAM in prosthetics and orthotics: Errors of measurement
    • M. Lilja, and T. Oberg Volumetric determinations with CAD/CAM in prosthetics and orthotics errors of measurement Journal of Rehabilitation Research and Development 32 1995 141 148
    • (1995) Journal of Rehabilitation Research and Development , vol.32 , pp. 141-148
    • Lilja, M.1    Oberg, T.2
  • 8
    • 0034553952 scopus 로고    scopus 로고
    • An accurate inexpensive system for the assessment of walking speed
    • S.B. Mitchell, and J.E. Sanders An accurate inexpensive system for the assessment of walking speed Journal of Prosthetics and Orthotics 12 2000 117 119
    • (2000) Journal of Prosthetics and Orthotics , vol.12 , pp. 117-119
    • Mitchell, S.B.1    Sanders, J.E.2
  • 9
    • 0036965104 scopus 로고    scopus 로고
    • Interface pressure and shear stress changes with amputee weight loss: Case studies from two trans-tibial amputee subjects
    • J.E. Sanders, J.R. Fergason, S.G. Zachariah, and A.K. Jacobsen Interface pressure and shear stress changes with amputee weight loss: case studies from two trans-tibial amputee subjects Prosthetics and Orthotics International 26 2002 243 250
    • (2002) Prosthetics and Orthotics International , vol.26 , pp. 243-250
    • Sanders, J.E.1    Fergason, J.R.2    Zachariah, S.G.3    Jacobsen, A.K.4
  • 10
    • 0034333697 scopus 로고    scopus 로고
    • Effects of changes in cadence, prosthetic componentry, and time on interface pressures and shear stresses of three trans-tibial amputees
    • J.E. Sanders, S.G. Zachariah, A.B. Baker, J.M. Greve, and C. Clinton Effects of changes in cadence, prosthetic componentry, and time on interface pressures and shear stresses of three trans-tibial amputees Clinical Biomechanics 15 2000 684 694
    • (2000) Clinical Biomechanics , vol.15 , pp. 684-694
    • Sanders, J.E.1    Zachariah, S.G.2    Baker, A.B.3    Greve, J.M.4    Clinton, C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.