메뉴 건너뛰기




Volumn 57, Issue 10, 2009, Pages 2550-2564

Integration of UWB and wireless pressure mapping in surgical navigation

Author keywords

Indoor positioning; Microelectromechanical systems (MEMS); Surgical navigation; Telemetry; Ultra wideband (UWB)

Indexed keywords

CHANNEL MODEL; FEMORAL CONDYLES; HOSPITAL ENVIRONMENT; IEEE 802.15.4A; IEEE802.11A; INDOOR POSITIONING; INDOOR TRACKING; LINE-OF-SIGHT; MICRO ELECTRO MECHANICAL SYSTEM; MICRO-CANTILEVERS; MICROELECTROMECHANICAL SYSTEMS (MEMS); NEW APPLICATIONS; PERFORMANCE METRICS; POSITIONING SYSTEM; PRESSURE MAPPING; ROOT-MEAN SQUARE ERRORS; SURGICAL NAVIGATION; SURGICAL TOOLS; TELEMETRY; TIME PRESSURES; UWB RECEIVERS; UWB TRANSMISSION; WIRELESS POSITIONING; WIRELESS PRESSURE SENSORS; WIRELESS TECHNOLOGIES;

EID: 70350200865     PISSN: 00189480     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMTT.2009.2029721     Document Type: Article
Times cited : (32)

References (44)
  • 1
    • 33644608178 scopus 로고    scopus 로고
    • Using wireless technologies in healthcare
    • U.Varshney, Using wireless technologies in healthcare, Int. J. Mobile Commun.,43 354-368, 2006.
    • (2006) Int. J. Mobile Commun. , vol.43 , pp. 354-368
    • Varshney, U.1
  • 2
    • 0036543760 scopus 로고    scopus 로고
    • Wireless telemedicine systems: An overview
    • C. Pattichis et al., Wireless telemedicine systems: An overview, IEEE Antennas Propag. Mag.,442 143-153, 2002.
    • (2002) IEEE Antennas Propag. Mag. , vol.442 , pp. 143-153
    • Pattichis, C.1
  • 3
    • 34047146556 scopus 로고    scopus 로고
    • Biocompatible MEMS electrode array for determination of three-dimensional strain
    • New York, Aug.
    • B. Evans, M. Mahfouz, and E. Pritchard, Biocompatible MEMS electrode array for determination of three-dimensional strain, in IEEE Int. Eng. Med. Biol. Soc. Conf., New York, Aug. 2006 4092-4095.
    • (2006) IEEE Int. Eng. Med. Biol. Soc. Conf. , pp. 4092-4095
    • Evans, B.1    Mahfouz, M.2    Pritchard, E.3
  • 4
    • 34047144375 scopus 로고    scopus 로고
    • ASIC design for wireless surgical MEMS device and instrumentation
    • New York, Aug.
    • G. To, W. Qu, and M. Mahfouz, ASIC design for wireless surgical MEMS device and instrumentation, in IEEE Int. Eng. Med. Biol. Soc. Conf., New York, Aug. 2006 5892-5895.
    • (2006) IEEE Int. Eng. Med. Biol. Soc. Conf. , pp. 5892-5895
    • To, G.1    Qu, W.2    Mahfouz, M.3
  • 5
    • 67649996006 scopus 로고    scopus 로고
    • Flexible capacitive sensors for high resolution pressure measurement
    • Lecce, Italy, Oct.
    • E. Pritchard, M. Mahfouz, B. Evans, S. Eliza, and M. Haider, Flexible capacitive sensors for high resolution pressure measurement, in IEEE Sens. Conf., Lecce, Italy, Oct. 2008 1484-1487.
    • (2008) IEEE Sens. Conf. , pp. 1484-1487
    • Pritchard, E.1    Mahfouz, M.2    Evans, B.3    Eliza, S.4    Haider, M.5
  • 6
    • 70350169579 scopus 로고    scopus 로고
    • Advanced technologies in navigation
    • Berlin, Germany: Springer ch. 2
    • F. Langlotz, G. Zheng, and L.-P. Nolte, Advanced technologies in navigation, in Navigation and MIS in Orthopedic Surgery. Berlin, Germany: Springer, 2007, ch. 2, pt. VII 582-585.
    • (2007) Navigation and MIS in Orthopedic Surgery , Issue.PART 7 , pp. 582-585
    • Langlotz, F.1    Zheng, G.2    Nolte, L.-P.3
  • 7
    • 70350162587 scopus 로고    scopus 로고
    • Basics of computer-assisted orthopaedic surgery
    • Berlin, Germany: Springer ch. 1
    • J. Kowal, F. Langlotz, and L. Nolte, Basics of computer-assisted orthopaedic surgery, in Navigation and MIS in Orthopedic Surgery. Berlin, Germany: Springer, 2007, ch. 1, pt. I 2-8.
    • (2007) Navigation and MIS in Orthopedic Surgery , Issue.PART I , pp. 2-8
    • Kowal, J.1    Langlotz, F.2    Nolte, L.3
  • 8
    • 70350143697 scopus 로고    scopus 로고
    • Polaris Spectra Polaris Vicra technical specifications
    • Waterloo, ON, Canada[Online]. Available
    • Polaris Spectra Polaris Vicra technical specifications, Northern Digital Inc., Waterloo, ON, Canada, 2008. [Online]. Available: http:// www.ndigital.com/medical/polarisfamily-techspecs.php
    • (2008) Northern Digital Inc.
  • 9
    • 70350140677 scopus 로고    scopus 로고
    • 3D guidance medSAFE
    • Corporation, Milton, VT[Online]. Available
    • 3D guidance medSAFE, Ascension Technol. Corporation, Milton, VT, 2008. [Online]. Available: http://www.ascension-tech.com/docs/ 3DGuide%20medSAFE.pdf
    • (2008) Ascension Technol.
  • 10
    • 70350160388 scopus 로고    scopus 로고
    • Surgical navigation systems: Evaluating electromagnetic versus optical technology in the or
    • presented at Meeting San Francisco, CA, Mar.
    • B. Merkl, M. Kuhn, M. Mahfouz, and D. DeBoer, Surgical navigation systems: Evaluating electromagnetic versus optical technology in the OR, presented at the Sci. Exhibit Amer. Acad. Orthopaedic Surgeons Annu. Meeting San Francisco, CA, Mar. 2008.
    • (2008) The Sci. Exhibit Amer. Acad. Orthopaedic Surgeons Annu.
    • Merkl, B.1    Kuhn, M.2    Mahfouz, M.3    Deboer, D.4
  • 11
    • 33845593775 scopus 로고    scopus 로고
    • Active-RFID system accuracy and its implications for clinical applications
    • Salt Lake City, UT, Jun.
    • D. Clarke and A. Park, Active-RFID system accuracy and its implications for clinical applications, in IEEE Int. Comput.-Based Med. Syst. Symp., Salt Lake City, UT, Jun. 2006 21-26.
    • (2006) IEEE Int. Comput.-Based Med. Syst. Symp. , pp. 21-26
    • Clarke, D.1    Park, A.2
  • 12
    • 70350145915 scopus 로고    scopus 로고
    • Hardware datasheet
    • Cambridge, U.K. [Online]. Available
    • Hardware datasheet, Ubisense, Cambridge, U.K., 2007. [Online]. Available: http://www.ubisense.net/media/pdf/ Ubisense%20System%20Overview%20V1.1.pdf
    • (2007) Ubisense
  • 13
    • 70350145914 scopus 로고    scopus 로고
    • Sapphire DART (RTLS) product data sheet
    • Germantown MD[Online]. Available
    • Sapphire DART (RTLS) product data sheet, Multispectral Solutions Inc., Germantown, MD, 2008. [Online]. Available: http://www.multispectral. com/pdf/Sapphire-DART.pdf
    • (2008) Multispectral Solutions Inc.
  • 14
    • 34548119895 scopus 로고    scopus 로고
    • Method for high precision clock synchronization in wireless systems with application to radio navigation
    • Long Beach, CA, Jan.
    • S. Roehr, P. Gulden, and M. Vossiek, Method for high precision clock synchronization in wireless systems with application to radio navigation, in IEEE Radio Wireless Symp., Long Beach, CA, Jan. 2007 551-554.
    • (2007) IEEE Radio Wireless Symp. , pp. 551-554
    • Roehr, S.1    Gulden, P.2    Vossiek, M.3
  • 15
    • 36649020683 scopus 로고    scopus 로고
    • Inverse synthetic aperture secondary radar concept for precise wireless positioning
    • Nov.
    • M. Vossiek, A. Urban, S. Max, and P. Gulden, Inverse synthetic aperture secondary radar concept for precise wireless positioning, IEEE Trans. Microw. Theory Tech.,5511 2447-2453, Nov. 2007.
    • (2007) IEEE Trans. Microw. Theory Tech. , vol.5511 , pp. 2447-2453
    • Vossiek, M.1    Urban, A.2    Max, S.3    Gulden, P.4
  • 16
    • 56749167953 scopus 로고    scopus 로고
    • Pulsed frequency modulation techniques for high-precision ultra wideband ranging and positioning
    • Hannover, Germany, Sep.
    • B. Waldmann, R. Weigel, P. Gulden, and M. Vossiek, Pulsed frequency modulation techniques for high-precision ultra wideband ranging and positioning, in IEEE Int. Ultra-Wideband Conf., Hannover, Germany, Sep. 2008 133-136.
    • (2008) IEEE Int. Ultra-Wideband Conf. , pp. 133-136
    • Waldmann, B.1    Weigel, R.2    Gulden, P.3    Vossiek, M.4
  • 17
    • 70350176943 scopus 로고    scopus 로고
    • Neubiberg, Germany[Online]. Available
    • LPR-2D datasheet, Symeo GmbH, Neubiberg, Germany, 2008. [Online]. Available: http://www.symeo.com/cms/upload/PDF/ Datasheet-LPR-2D.pdf
    • (2008) LPR-2D Datasheet
  • 19
    • 45349088803 scopus 로고    scopus 로고
    • Investigation of high accuracy indoor 3-D positioning using UWB technology
    • Jun.
    • M. Mahfouz, C. Zhang, B. Merkl, M. Kuhn, and A. Fathy, Investigation of high accuracy indoor 3-D positioning using UWB technology, IEEE Trans. Microw. Theory Tech.,566 1316-1330, Jun. 2008.
    • (2008) IEEE Trans. Microw. Theory Tech. , vol.566 , pp. 1316-1330
    • Mahfouz, M.1    Zhang, C.2    Merkl, B.3    Kuhn, M.4    Fathy, A.5
  • 20
    • 34250310866 scopus 로고    scopus 로고
    • Development of an UWB indoor 3-D positioning radar with millimeter accuracy
    • San Francisco, CA, Jun.
    • C. Zhang, M. Kuhn, B. Merkl, M. Mahfouz, and A. Fathy, Development of an UWB indoor 3-D positioning radar with millimeter accuracy, in IEEE MTT-S Int. Microw. Symp., San Francisco, CA, Jun. 2006 106-109.
    • (2006) IEEE MTT-S Int. Microw. Symp. , pp. 106-109
    • Zhang, C.1    Kuhn, M.2    Merkl, B.3    Mahfouz, M.4    Fathy, A.5
  • 21
    • 36749003939 scopus 로고    scopus 로고
    • Performance enhancement of a sub-sampling circuit for ultra-wideband signal processing
    • C. Zhang, A. Fathy, and M. Mahfouz, Performance enhancement of a sub-sampling circuit for ultra-wideband signal processing, IEEE Microw. Wireless Compon. Lett.,1712 873-875, 2007.
    • (2007) IEEE Microw. Wireless Compon. Lett. , vol.1712 , pp. 873-875
    • Zhang, C.1    Fathy, A.2    Mahfouz, M.3
  • 24
    • 77949937673 scopus 로고    scopus 로고
    • Real-time noncoherent UWB positioning radar with millimeter range accuracy in a 3D indoor environment
    • Boston, MA, Jun.
    • C. Zhang, M. Kuhn, M. Mahfouz, and A. Fathy, Real-time noncoherent UWB positioning radar with millimeter range accuracy in a 3D indoor environment, in IEEE MTT-S Int. Microw. Symp. Dig., Boston, MA, Jun. 2009 1413-1416.
    • (2009) IEEE MTT-S Int. Microw. Symp. Dig. , pp. 1413-1416
    • Zhang, C.1    Kuhn, M.2    Mahfouz, M.3    Fathy, A.4
  • 25
    • 63649118155 scopus 로고    scopus 로고
    • Operating room of the future: Orthopedic perspective
    • presented at Invited Talk, Cairo, Egypt, Dec.
    • M. Mahfouz, Operating room of the future: Orthopedic perspective, presented at the Cairo Int. Biomed. Eng. Conf. Invited Talk, Cairo, Egypt, Dec. 2008.
    • (2008) The Cairo Int. Biomed. Eng. Conf.
    • Mahfouz, M.1
  • 26
    • 70350157324 scopus 로고    scopus 로고
    • The future of the operating room: Surgical preplanning and navigation using high accuracy ultra-wideband positioning and advanced bone measurement
    • Univ. Tennessee, Knoxville, TN
    • B. Merkl, The future of the operating room: Surgical preplanning and navigation using high accuracy ultra-wideband positioning and advanced bone measurement, Ph.D. dissertation, Mech. Aero. Biomed. Eng. Dept., Univ. Tennessee, Knoxville, TN, 2008.
    • (2008) Ph.D. Dissertation, Mech. Aero. Biomed. Eng. Dept.
    • Merkl, B.1
  • 28
    • 23944432309 scopus 로고    scopus 로고
    • IEEE 802.15.4a channel model-Final report
    • Doc. IEEE 802.1504-0062-02-004a
    • A. Molisch et al., IEEE 802.15.4a channel model-Final report, IEEE, Piscataway, NJ, Tech. Rep., Doc. IEEE 802.1504-0062-02-004a, 2005.
    • (2005) IEEE, Piscataway, NJ, Tech. Rep.
    • Molisch, A.1
  • 30
    • 70350165519 scopus 로고    scopus 로고
    • Electromagnetic interference and its effects on ultra-wideband technology in the operating room
    • Cairo, Egypt, Dec.
    • M. Kuhn, M. Mahfouz, C. Zhang, B. Merkl, and A. Fathy, Electromagnetic interference and its effects on ultra-wideband technology in the operating room, in Int. Biomed. Eng. Conf., Cairo, Egypt, Dec. 2006 1-4.
    • (2006) Int. Biomed. Eng. Conf. , pp. 1-4
    • Kuhn, M.1    Mahfouz, M.2    Zhang, C.3    Merkl, B.4    Fathy, A.5
  • 31
    • 0029957193 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues: III Parametric models for the dielectric spectrum of tissue
    • S. Gabriel, R. W. Lau, and C. Gabriel, The dielectric properties of biological tissues: III Parametric models for the dielectric spectrum of tissue, Phys. Med. Biol.,41 2271-2293, 1996.
    • (1996) Phys. Med. Biol. , vol.41 , pp. 2271-2293
    • Gabriel, S.1    Lau, R.W.2    Gabriel, C.3
  • 33
    • 33645465509 scopus 로고    scopus 로고
    • RFID remedy for medical errors
    • May[Online]. Available
    • J. Collins, RFID remedy for medical errors, RFID J. May 28, 2004. [Online]. Available: http://www.rfidjournal.com/article/view/961/1/1
    • (2004) RFID J. , vol.28
    • Collins, J.1
  • 34
    • 33745937509 scopus 로고    scopus 로고
    • Wireless transmission of ECG signal
    • N. F. Güler and U. Fidan, Wireless transmission of ECG signal, J. Med. Syst.,303 231-235, 2006.
    • (2006) J. Med. Syst. , vol.303 , pp. 231-235
    • Güler, N.F.1    Fidan, U.2
  • 35
    • 70350154117 scopus 로고    scopus 로고
    • Path loss in remote keyless entry systems
    • Sunnyvale, CA, Appl. Note 3945, Dec. [Online]. Available
    • Path loss in remote keyless entry systems, Maxim-IC Inc., Sunnyvale, CA, Appl. Note 3945, Dec. 15, 2006. [Online]. Available: http:// www.maxim-ic.com/appnotes.cfm/an-pk/3945
    • (2006) Maxim-IC Inc. , vol.15
  • 36
    • 70350169577 scopus 로고    scopus 로고
    • Unsupervised three-dimensional segmentation of medical images using an anatomical bone atlas
    • Singapore, Dec.
    • B. Merkl and M. Mahfouz, Unsupervised three-dimensional segmentation of medical images using an anatomical bone atlas, in 12th Int. Biomed. Eng. Conf., Singapore, Dec. 2005 1-5.
    • (2005) 12th Int. Biomed. Eng. Conf. , pp. 1-5
    • Merkl, B.1    Mahfouz, M.2
  • 39
    • 0344012667 scopus 로고    scopus 로고
    • A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images
    • Dec.
    • M. Mahfouz, W. Hoff, R. Komistek, and D. Dennis, A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images, IEEE Trans. Med. Imag.,2212 1561-1574, Dec. 2003.
    • (2003) IEEE Trans. Med. Imag. , vol.2212 , pp. 1561-1574
    • Mahfouz, M.1    Hoff, W.2    Komistek, R.3    Dennis, D.4
  • 40
    • 5444226067 scopus 로고    scopus 로고
    • An intraoperative pressure-measuring device used in total knee arthroplasties and its kinematics correlations
    • R. Wasielewski, D. Galat, and R. Komistek, An intraoperative pressure-measuring device used in total knee arthroplasties and its kinematics correlations, Clin. Orthopaedic Rel. Res.,427 171-178, 2004.
    • (2004) Clin. Orthopaedic Rel. Res. , vol.427 , pp. 171-178
    • Wasielewski, R.1    Galat, D.2    Komistek, R.3
  • 41
    • 48349114489 scopus 로고    scopus 로고
    • Micro-cantilever array pressure measurement system for biomedical instrumentation
    • Atlanta, GA, Oct.
    • W. Qu, S. Islam, G. To, and M. Mahfouz, Micro-cantilever array pressure measurement system for biomedical instrumentation, in IEEE Sens. Conf., Atlanta, GA, Oct. 2007 1009-1012.
    • (2007) IEEE Sens. Conf. , pp. 1009-1012
    • Qu, W.1    Islam, S.2    To, G.3    Mahfouz, M.4
  • 42
    • 70350174052 scopus 로고    scopus 로고
    • Design optimization of a three-dimensional strain sensor using multiphysics finite element analysis
    • Cairo, Egypt, Dec.
    • B. Evans and M. Mahfouz, Design optimization of a three-dimensional strain sensor using multiphysics finite element analysis, in Int. Biomed. Eng. Conf., Cairo, Egypt, Dec. 2006 1-4.
    • (2006) Int. Biomed. Eng. Conf. , pp. 1-4
    • Evans, B.1    Mahfouz, M.2
  • 44
    • 0036477053 scopus 로고    scopus 로고
    • Broadband and compact multi-pole microstrip bandpass filters using ground plane aperture technique
    • Antennas, Propag.
    • L. Zhu, H. Bu, and K. Wu, Broadband and compact multi-pole microstrip bandpass filters using ground plane aperture technique, Proc. Inst. Elect. Eng.-Microw., Antennas, Propag.,1491 71-77, 2002.
    • (2002) Proc. Inst. Elect. Eng.-Microw. , vol.1491 , pp. 71-77
    • Zhu, L.1    Bu, H.2    Wu, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.