메뉴 건너뛰기




Volumn , Issue , 2006, Pages 4092-4095

Biocompatible MEMS electrode array for determination of three-dimensional strain

Author keywords

[No Author keywords available]

Indexed keywords

BIOCOMPATIBLE POLYMERS; CAPACITIVE SENSORS; STRAIN SENSOR; TOTAL KNEE ARTHROPLASTY (TKA);

EID: 34047146556     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2006.259258     Document Type: Conference Paper
Times cited : (4)

References (9)
  • 1
    • 34047105964 scopus 로고    scopus 로고
    • National Hospital Discharge Summary, Stats. Available
    • National Hospital Discharge Summary 2001. National Center for Health Stats. Available: http://www.cdc.gov/nchs/data/series/sr_13/sr13_156.pdf
    • (2001) National Center for Health
  • 2
    • 0034950717 scopus 로고    scopus 로고
    • H, CS Ranawat. Total Condylar Knee Replacement A 20-Year Followup Study
    • JA Rodriguez, H Bhende H, CS Ranawat. Total Condylar Knee Replacement A 20-Year Followup Study. Clin Orthop 388: 10-17, 2001.
    • (2001) Clin Orthop , vol.388 , pp. 10-17
    • Rodriguez, J.A.1    Bhende, H.2
  • 4
    • 0013873902 scopus 로고
    • Forces acting on the femoral head-prosthesis. A study on strain gauge supplied prostheses in living persons
    • NW Rydell. Forces acting on the femoral head-prosthesis. A study on strain gauge supplied prostheses in living persons. Acta Orthop Scand. 1966;37:Suppl 88:1-132
    • (1966) Acta Orthop Scand , vol.37 , Issue.SUPPL. 88 , pp. 1-132
    • Rydell, N.W.1
  • 7
    • 0030220033 scopus 로고    scopus 로고
    • H Ishikawa H, H Fujiki, K Yasuda. Contact Analysis of Ultrahigh Molecular Weight Polyethylene Articular Plate in Artificial Knee Joint During Gait Movement. (1996): J. Biomech. Eng. 118, pp. 377-386.
    • H Ishikawa H, H Fujiki, K Yasuda. Contact Analysis of Ultrahigh Molecular Weight Polyethylene Articular Plate in Artificial Knee Joint During Gait Movement. (1996): J. Biomech. Eng. 118, pp. 377-386.
  • 8
    • 0036853009 scopus 로고    scopus 로고
    • Effect of Fuji pressure sensitive film on actual contact characteristics of artificial tibiofemoral joint
    • J Liau, C Cheng, C Huang, and W Lo. Effect of Fuji pressure sensitive film on actual contact characteristics of artificial tibiofemoral joint. (2002): Clin. Biomech. 17 pp. 689-704.
    • (2002) Clin. Biomech , vol.17 , pp. 689-704
    • Liau, J.1    Cheng, C.2    Huang, C.3    Lo, W.4
  • 9
    • 0344012667 scopus 로고    scopus 로고
    • A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images
    • MR Mahfouz, WA Hoff, RD Komistek, and DA Dennis. A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images. (2003) IEEE Trans. Med. Imaging 22: pp. 1561-1574.
    • (2003) IEEE Trans. Med. Imaging , vol.22 , pp. 1561-1574
    • Mahfouz, M.R.1    Hoff, W.A.2    Komistek, R.D.3    Dennis, D.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.