메뉴 건너뛰기




Volumn 2009, Issue , 2009, Pages

Cone beam micro-CT system for small animal maging and performance evaluation

Author keywords

[No Author keywords available]

Indexed keywords

3D RECONSTRUCTION; ANATOMIC INFORMATION; BIOLUMINESCENCE TOMOGRAPHY; CONE BEAM; CONE-BEAM MICRO-CT; CONTRAST AGENT; DATA PREPROCESSING; DUAL-MODALITY SYSTEMS; FLAT-PANEL X-RAY DETECTOR; GEOMETRIC CALIBRATIONS; GEOMETRY CALIBRATION; GRAPHICS PROCESSING UNIT; HIGH RESOLUTION; HIGH SPATIAL RESOLUTION; IMAGE UNIFORMITY; LARGE FIELD OF VIEWS; LOW CONTRAST RESOLUTION; MICRO-CT SYSTEMS; MICROFOCUS X-RAY SOURCE; PERFORMANCE EVALUATION; POINT-SPREAD FUNCTION; SINGLE SCAN; SMALL ANIMAL; SMALL ANIMAL IMAGING; SPATIAL RESOLUTION; WHOLE-BODY IMAGING;

EID: 70349922904     PISSN: 16874188     EISSN: 16874196     Source Type: Journal    
DOI: 10.1155/2009/960573     Document Type: Article
Times cited : (60)

References (31)
  • 1
    • 1142263259 scopus 로고    scopus 로고
    • In vivo molecular and genomic imaging: New challenges for imaging physics
    • Cherry S. R., In vivo molecular and genomic imaging: new challenges for imaging physics Physics in Medical and Biology 2004 49 3 R13 R48
    • (2004) Physics in Medical and Biology , vol.49 , Issue.3
    • Cherry, S.R.1
  • 2
    • 0027205207 scopus 로고
    • A high-resolution XRII-based quantitative volume CT scanner
    • Holdsworth D. W., Drangova M., Fenster A., A high-resolution XRII-based quantitative volume CT scanner Medical Physics 1993 20 2 449 462
    • (1993) Medical Physics , vol.20 , Issue.2 , pp. 449-462
    • Holdsworth, D.W.1    Drangova, M.2    Fenster, A.3
  • 5
    • 0347597904 scopus 로고    scopus 로고
    • A flat-panel detector based micro-CT system: Performance evaluation for small-animal imaging
    • Lee S. C., Kim H. K., Chun I. K., Cho M. H., Lee S. Y., Cho M. H., A flat-panel detector based micro-CT system: performance evaluation for small-animal imaging Physics in Medical and Biology 2003 48 24 4173 4185
    • (2003) Physics in Medical and Biology , vol.48 , Issue.24 , pp. 4173-4185
    • Lee, S.C.1    Kim, H.K.2    Chun, I.K.3    Cho, M.H.4    Lee, S.Y.5    Cho, M.H.6
  • 6
    • 45849121444 scopus 로고    scopus 로고
    • Assessment of a new high-performance small-animal X-ray tomography
    • Vaquero J. J., Redondo S., Lage E., Assessment of a new high-performance small-animal X-ray tomography IEEE Transactions on Nuclear Science 2008 55 3 898 905
    • (2008) IEEE Transactions on Nuclear Science , vol.55 , Issue.3 , pp. 898-905
    • Vaquero, J.J.1    Redondo, S.2    Lage, E.3
  • 7
    • 43749107765 scopus 로고    scopus 로고
    • Micro-computed tomography for small animal imaging: Technological details
    • Li H., Zhang H., Tang Z., Hu G., Micro-computed tomography for small animal imaging: technological details Progress in Natural Science 2008 18 5 513 521
    • (2008) Progress in Natural Science , vol.18 , Issue.5 , pp. 513-521
    • Li, H.1    Zhang, H.2    Tang, Z.3    Hu, G.4
  • 8
    • 0034088968 scopus 로고    scopus 로고
    • High resolution X-ray computed tomography: An emerging tool for small animal cancer research
    • Paulus M. J., Gleason S. S., Kennel S. J., Hunsicker P. R., Johnson D. K., High resolution X-ray computed tomography: an emerging tool for small animal cancer research Neoplasia 2000 2 1-2 62 70
    • (2000) Neoplasia , vol.2 , Issue.12 , pp. 62-70
    • Paulus, M.J.1    Gleason, S.S.2    Kennel, S.J.3    Hunsicker, P.R.4    Johnson, D.K.5
  • 9
    • 0035390579 scopus 로고    scopus 로고
    • Micro-CT scanners for biomedical applications: An overview
    • Wang G., Vannier M., Micro-CT scanners for biomedical applications: an overview Advanced Imaging 2001 16 7 18 27
    • (2001) Advanced Imaging , vol.16 , Issue.7 , pp. 18-27
    • Wang, G.1    Vannier, M.2
  • 10
    • 41649110649 scopus 로고    scopus 로고
    • Imaging in the era of molecular oncology
    • Weissleder R., Pittet M. J., Imaging in the era of molecular oncology Nature 2008 452 7187 580 589
    • (2008) Nature , vol.452 , Issue.7187 , pp. 580-589
    • Weissleder, R.1    Pittet, M.J.2
  • 14
    • 33747799016 scopus 로고    scopus 로고
    • In vivo mouse studies with bioluminescence tomography
    • Wang G., Cong W., Durairaj K., In vivo mouse studies with bioluminescence tomography Optics Express 2006 14 17 7801 7809
    • (2006) Optics Express , vol.14 , Issue.17 , pp. 7801-7809
    • Wang, G.1    Cong, W.2    Durairaj, K.3
  • 17
    • 11244310646 scopus 로고    scopus 로고
    • Geometric misalignment and calibration in cone-beam tomography
    • von Smekal L., Kachelrie M., Stepina E., Kalender W. A., Geometric misalignment and calibration in cone-beam tomography Medical Physics 2004 31 12 3242 3266
    • (2004) Medical Physics , vol.31 , Issue.12 , pp. 3242-3266
    • Von Smekal, L.1    Kachelrie, M.2    Stepina, E.3    Kalender, W.A.4
  • 18
    • 33744794934 scopus 로고    scopus 로고
    • A geometric calibration method for cone beam CT systems
    • Yang K., Kwan A. L. C., Miller D. F., Boone J. M., A geometric calibration method for cone beam CT systems Medical Physics 2006 33 6 1695 1706
    • (2006) Medical Physics , vol.33 , Issue.6 , pp. 1695-1706
    • Yang, K.1    Kwan, A.L.C.2    Miller, D.F.3    Boone, J.M.4
  • 19
    • 47649113588 scopus 로고    scopus 로고
    • An optimization-based method for geometrical calibration in cone-beam CT without dedicated phantoms
    • Panetta D., Belcari N., Guerra A. D., Moehrs S., An optimization-based method for geometrical calibration in cone-beam CT without dedicated phantoms Physics in Medicine and Biology 2008 53 14 3841 3861
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.14 , pp. 3841-3861
    • Panetta, D.1    Belcari, N.2    Guerra, A.D.3    Moehrs, S.4
  • 20
    • 0020764170 scopus 로고
    • An inversion-formula for cone-beam reconstruction
    • Tuy H. K., An inversion-formula for cone-beam reconstruction SIAM Journal on Applied Mathematics 1983 43 3 546 552
    • (1983) SIAM Journal on Applied Mathematics , vol.43 , Issue.3 , pp. 546-552
    • Tuy, H.K.1
  • 21
    • 0022026907 scopus 로고
    • Image reconstruction from cone-beam projections: Necessary and sufficient conditions and reconstruction methods
    • Smith B. D., Image reconstruction from cone-beam projections: necessary and sufficient conditions and reconstruction methods IEEE Transactions on Medical Imaging 1985 4 1 14 25
    • (1985) IEEE Transactions on Medical Imaging , vol.4 , Issue.1 , pp. 14-25
    • Smith, B.D.1
  • 22
    • 0036680539 scopus 로고    scopus 로고
    • Micro-CT in small animal and specimen imaging
    • Holdsworth D. W., Thornton M. M., Micro-CT in small animal and specimen imaging Trends in Biotechnology 2002 20 8 34 39
    • (2002) Trends in Biotechnology , vol.20 , Issue.8 , pp. 34-39
    • Holdsworth, D.W.1    Thornton, M.M.2
  • 26
    • 0018386456 scopus 로고
    • Correction for beam hardening in computed tomography
    • Herman G. T., Correction for beam hardening in computed tomography Physics in Medicine and Biology 1979 24 1 81 106
    • (1979) Physics in Medicine and Biology , vol.24 , Issue.1 , pp. 81-106
    • Herman, G.T.1
  • 28
    • 43149107960 scopus 로고    scopus 로고
    • Respiratory-gated micro-CT using a carbon nanotube based micro-focus field emission X-ray source
    • Medical Imaging 2008: Physics of Medical Imaging February 2008 San Diego, Calif
    • Cao G., Lee Y. Z., Liu Z., Respiratory-gated micro-CT using a carbon nanotube based micro-focus field emission X-ray source 6913 Medical Imaging 2008: Physics of Medical Imaging February 2008 San Diego, Calif, USA Proceedings of SPIE
    • USA Proceedings of SPIE , vol.6913
    • Cao, G.1    Lee, Y.Z.2    Liu, Z.3
  • 29
    • 43149107483 scopus 로고    scopus 로고
    • Motion gated small animal imaging with a flat-panel CT
    • Medical Imaging 2008: Physics of Medical Imaging February 2008 San Diego, Calif
    • Grasruck M., Bartling S., Dinkel J., Motion gated small animal imaging with a flat-panel CT 6913 Medical Imaging 2008: Physics of Medical Imaging February 2008 San Diego, Calif, USA Proceedings of SPIE
    • USA Proceedings of SPIE , vol.6913
    • Grasruck, M.1    Bartling, S.2    Dinkel, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.