메뉴 건너뛰기




Volumn 14, Issue 5, 2009, Pages 497-504

How accurate is image-free computer navigation for hip resurfacing arthroplasty? An anatomical investigation

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER PROGRAM; FEMUR HEAD PROSTHESIS; HIP ARTHROPLASTY; HUMAN; IMAGE FREE COMPUTER NAVIGATION; IMPLANTATION;

EID: 70349679031     PISSN: 09492658     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00776-009-1356-5     Document Type: Article
Times cited : (6)

References (27)
  • 2
    • 64849117902 scopus 로고    scopus 로고
    • Femoral component positioning in hip resurfacing with and without navigation
    • 18484146 10.1007/s11999-008-0299-z
    • M. Ganapathi P.A. Vendittoli M. Lavigne K.P. Gunther 2009 Femoral component positioning in hip resurfacing with and without navigation Clin Orthop 467 1341 1347 18484146 10.1007/s11999-008-0299-z
    • (2009) Clin Orthop , vol.467 , pp. 1341-1347
    • Ganapathi, M.1    Vendittoli, P.A.2    Lavigne, M.3    Gunther, K.P.4
  • 3
    • 4544332678 scopus 로고    scopus 로고
    • Orientation of the femoral component in surface arthroplasty of the hip: A biomechanical and clinical analysis
    • 15342765
    • P.E. Beaule J.L. Lee M.J. Le Duff H.C. Amstutz E. Ebramzadeh 2004 Orientation of the femoral component in surface arthroplasty of the hip: a biomechanical and clinical analysis J Bone Joint Surg Am 86 2015 2021 15342765
    • (2004) J Bone Joint Surg Am , vol.86 , pp. 2015-2021
    • Beaule, P.E.1    Lee, J.L.2    Le Duff, M.J.3    Amstutz, H.C.4    Ebramzadeh, E.5
  • 4
    • 17744365971 scopus 로고    scopus 로고
    • Femoral neck fractures following Birmingham hip resurfacing
    • DOI 10.1302/0301-620X.87B4.15498
    • A.J. Shimmin D. Back 2005 Femoral neck fractures following Birmingham hip resurfacing: a national review of 50 cases J Bone Joint Surg Br 87 463 464 15795193 10.1302/0301-620X.87B4.15498 1:STN:280:DC%2BD2M7mt12ltA%3D%3D (Pubitemid 40575766)
    • (2005) Journal of Bone and Joint Surgery - Series B , vol.87 , Issue.4 , pp. 463-464
    • Shimmin, A.J.1    Back, D.2
  • 5
    • 33750044845 scopus 로고    scopus 로고
    • Sind navigierte knieendoprothesen tatsächlich pravziser implantiert? Eine metaanalyse vergleichender studien
    • DOI 10.1007/s00132-006-1001-3
    • H. Bathis S. Shafizadeh T. Paffrath C. Simanski J. Grifka C. Luring 2006 [Are computer assisted total knee replacements more accurately placed? A meta-analysis of comparative studies.] Orthopade 35 1056 1065 16953328 10.1007/s00132-006-1001-3 1:STN:280:DC%2BD28jltl2juw%3D%3D (Pubitemid 44579711)
    • (2006) Orthopade , vol.35 , Issue.10 , pp. 1056-1065
    • Bathis, H.1    Shafizadeh, S.2    Paffrath, T.3    Simanski, C.4    Grifka, J.5    Luring, C.6
  • 6
    • 34249794249 scopus 로고    scopus 로고
    • The accuracy of image-free computer navigation in the placement of the femoral component of the Birmingham Hip Resurfacing
    • DOI 10.1302/0301-620X.89B4.17893
    • E.T. Davis P. Gallie K. Macgroarty J.P. Waddell E. Schemitsch 2007 The accuracy of image-free computer navigation in the placement of the femoral component of the Birmingham hip resurfacing: a cadaver study J Bone Joint Surg Br 89 557 560 17463131 10.1302/0301-620X.89B4.17893 1:STN:280: DC%2BD2srjvFCgtg%3D%3D (Pubitemid 46851142)
    • (2007) Journal of Bone and Joint Surgery - Series B , vol.89 , Issue.4 , pp. 557-560
    • Davis, E.T.1    Gallie, P.2    Macgroarty, K.3    Waddell, J.P.4    Schemitsch, E.5
  • 7
    • 41149149865 scopus 로고    scopus 로고
    • Intraoperative navigation in hip surface arthroplasty: A radiographic comparative analysis study
    • 18071723 10.1007/s00402-007-0540-3
    • R. Hart P. Svab P. Filan 2007 Intraoperative navigation in hip surface arthroplasty: a radiographic comparative analysis study Arch Orthop Trauma Surg 128 429 434 18071723 10.1007/s00402-007-0540-3
    • (2007) Arch Orthop Trauma Surg , vol.128 , pp. 429-434
    • Hart, R.1    Svab, P.2    Filan, P.3
  • 9
    • 64249161668 scopus 로고    scopus 로고
    • Imageless navigation of hip resurfacing arthroplasty increases the implant accuracy
    • 18157534 10.1007/s00264-007-0494-7 1:STN:280:DC%2BD1M3ltlentw%3D%3D
    • C. Schnurr J.W. Michael P. Eysel D.P. Konig 2009 Imageless navigation of hip resurfacing arthroplasty increases the implant accuracy Int Orthop 33 365 372 18157534 10.1007/s00264-007-0494-7 1:STN:280:DC%2BD1M3ltlentw%3D%3D
    • (2009) Int Orthop , vol.33 , pp. 365-372
    • Schnurr, C.1    Michael, J.W.2    Eysel, P.3    Konig, D.P.4
  • 10
    • 23644444318 scopus 로고    scopus 로고
    • Femoral neck radiography: Effect of flexion on visualization
    • 16144275
    • S.C. Garry G.S. Jhangri R.G. Lambert 2005 Femoral neck radiography: effect of flexion on visualization Can Assoc Radiol J 56 155 162 16144275
    • (2005) Can Assoc Radiol J , vol.56 , pp. 155-162
    • Garry, S.C.1    Jhangri, G.S.2    Lambert, R.G.3
  • 11
    • 0020561473 scopus 로고
    • Radiographic measurements of the femoral neck anteversion: Comparison of two simplified procedures
    • 6845985 1:STN:280:DyaL3s3gtVahsg%3D%3D
    • K. Herrlin L. Ekelund 1983 Radiographic measurements of the femoral neck anteversion: comparison of two simplified procedures Acta Orthop Scand 54 141 147 6845985 1:STN:280:DyaL3s3gtVahsg%3D%3D
    • (1983) Acta Orthop Scand , vol.54 , pp. 141-147
    • Herrlin, K.1    Ekelund, L.2
  • 12
    • 0033762709 scopus 로고    scopus 로고
    • The effect of femoral rotation on the projected femoral neck-shaft angle
    • 11097245 1:STN:280:DC%2BD3MzgsFOmsw%3D%3D
    • R.M. Kay K.A. Jaki D.L. Skaggs 2000 The effect of femoral rotation on the projected femoral neck-shaft angle J Pediatr Orthop 20 736 739 11097245 1:STN:280:DC%2BD3MzgsFOmsw%3D%3D
    • (2000) J Pediatr Orthop , vol.20 , pp. 736-739
    • Kay, R.M.1    Jaki, K.A.2    Skaggs, D.L.3
  • 13
    • 0037381342 scopus 로고    scopus 로고
    • Measurement of femoral anteversion by biplane radiography and computed tomography imaging: Comparison with an anatomic reference
    • DOI 10.1097/00004424-200304000-00006
    • T.Y. Kuo J.G. Skedros R.D. Bloebaum 2003 Measurement of femoral anteversion by biplane radiography and computed tomography imaging: comparison with an anatomic reference Invest Radiol 38 221 229 12649646 10.1097/00004424-200304000-00006 (Pubitemid 36384001)
    • (2003) Investigative Radiology , vol.38 , Issue.4 , pp. 221-229
    • Kuo, T.Y.1    Skedros, J.G.2    Bloebaum, R.D.3
  • 14
    • 0028096242 scopus 로고
    • Evaluation of CT scans and 3-D reformatted images for quantitative assessment of the hip
    • 8113372 1:STN:280:DyaK2c7lslSntQ%3D%3D
    • M.F. Abel D.H. Sutherland D.R. Wenger S.J. Mubarak 1994 Evaluation of CT scans and 3-D reformatted images for quantitative assessment of the hip J Pediatr Orthop 14 48 53 8113372 1:STN:280:DyaK2c7lslSntQ%3D%3D
    • (1994) J Pediatr Orthop , vol.14 , pp. 48-53
    • Abel, M.F.1    Sutherland, D.H.2    Wenger, D.R.3    Mubarak, S.J.4
  • 16
    • 34447276911 scopus 로고    scopus 로고
    • Femoral component sizing and positioning in hip resurfacing arthroplasty
    • 17472304
    • P.E. Beaule P. Poitras 2007 Femoral component sizing and positioning in hip resurfacing arthroplasty Instr Course Lect 56 163 169 17472304
    • (2007) Instr Course Lect , vol.56 , pp. 163-169
    • Beaule, P.E.1    Poitras, P.2
  • 17
    • 33745646707 scopus 로고    scopus 로고
    • Biomechanical reconstruction of the hip: A randomised study comparing total hip resurfacing and total hip arthroplasty
    • DOI 10.1302/0301-620X.88B6.17447
    • J. Girard M. Lavigne P.A. Vendittoli A.G. Roy 2006 Biomechanical reconstruction of the hip: a randomised study comparing total hip resurfacing and total hip arthroplasty J Bone Joint Surg Br 88 721 726 16720762 1:STN:280:DC%2BD28vgvFelsw%3D%3D (Pubitemid 43971134)
    • (2006) Journal of Bone and Joint Surgery - Series B , vol.88 , Issue.6 , pp. 721-726
    • Girard, J.1    Lavigne, M.2    Vendittoli, P.-A.3    Roy, A.G.4
  • 18
    • 33845445598 scopus 로고    scopus 로고
    • Surgical variables affect the mechanics of a hip resurfacing system
    • DOI 10.1097/01.blo.0000238873.09390.6f, PII 0000308620061200000020
    • J.P. Long D.L. Bartel 2006 Surgical variables affect the mechanics of a hip resurfacing system Clin Orthop 453 115 122 17016222 10.1097/01.blo. 0000238873.09390.6f (Pubitemid 44900969)
    • (2006) Clinical Orthopaedics and Related Research , Issue.453 , pp. 115-122
    • Long, J.P.1    Bartel, D.L.2
  • 19
    • 51349169503 scopus 로고    scopus 로고
    • Position of hip resurfacing component affects strain and resistance to fracture in the femoral neck
    • 18762656 10.2106/JBJS.F.00788
    • T.P. Vail R.R. Glisson D.E. Dominguez K. Kitaoka D. Ottaviano 2008 Position of hip resurfacing component affects strain and resistance to fracture in the femoral neck J Bone Joint Surg Am 90 1951 1960 18762656 10.2106/JBJS.F.00788
    • (2008) J Bone Joint Surg Am , vol.90 , pp. 1951-1960
    • Vail, T.P.1    Glisson, R.R.2    Dominguez, D.E.3    Kitaoka, K.4    Ottaviano, D.5
  • 20
    • 63049121864 scopus 로고    scopus 로고
    • Imageless computer navigation for placement of the femoral component in resurfacing arthroplasty of the hip
    • 19258604 10.1302/0301-620X.91B3.21288 1:STN:280:DC%2BD1M7otlOjsQ%3D%3D
    • M. Olsen E.T. Davis J.P. Waddell E.H. Schemitsch 2009 Imageless computer navigation for placement of the femoral component in resurfacing arthroplasty of the hip J Bone Joint Surg Br 91 310 315 19258604 10.1302/0301-620X.91B3.21288 1:STN:280:DC%2BD1M7otlOjsQ%3D%3D
    • (2009) J Bone Joint Surg Br , vol.91 , pp. 310-315
    • Olsen, M.1    Davis, E.T.2    Waddell, J.P.3    Schemitsch, E.H.4
  • 21
    • 35948939885 scopus 로고    scopus 로고
    • Hip resurfacing femoral neck fracture influenced by valgus placement
    • 17589356
    • C. Anglin B.A. Masri J. Tonetti A.J. Hodgson N.V. Greidanus 2007 Hip resurfacing femoral neck fracture influenced by valgus placement Clin Orthop 465 71 79 17589356
    • (2007) Clin Orthop , vol.465 , pp. 71-79
    • Anglin, C.1    Masri, B.A.2    Tonetti, J.3    Hodgson, A.J.4    Greidanus, N.V.5
  • 22
    • 35348816399 scopus 로고    scopus 로고
    • Navigation reduces the learning curve in resurfacing total hip arthroplasty
    • 17603387
    • J.P. Cobb V. Kannan K. Brust G. Thevendran 2007 Navigation reduces the learning curve in resurfacing total hip arthroplasty Clin Orthop 463 90 97 17603387
    • (2007) Clin Orthop , vol.463 , pp. 90-97
    • Cobb, J.P.1    Kannan, V.2    Brust, K.3    Thevendran, G.4
  • 23
    • 0023617120 scopus 로고
    • Delayed diagnosis of femoral-neck fractures in the elderly
    • 3425484 10.1093/ageing/16.6.378 1:STN:280:DyaL1c7gtlSnsA%3D%3D
    • H.D. Eastwood 1987 Delayed diagnosis of femoral-neck fractures in the elderly Age Ageing 16 378 382 3425484 10.1093/ageing/16.6.378 1:STN:280:DyaL1c7gtlSnsA%3D%3D
    • (1987) Age Ageing , vol.16 , pp. 378-382
    • Eastwood, H.D.1
  • 24
    • 0001577195 scopus 로고
    • A study to determine the angle of anteversion of the neck of the femur
    • P.C. Kingsley K.L. Olmested 1948 A study to determine the angle of anteversion of the neck of the femur J Bone Joint Surg Am 30 745 751
    • (1948) J Bone Joint Surg Am , vol.30 , pp. 745-751
    • Kingsley, P.C.1    Olmested, K.L.2
  • 25
    • 0019780767 scopus 로고
    • Fracture of neck of the femur: Changing incidence
    • 10.1136/bmj.283.6301.1217 1:STN:280:DyaL38%2Fpt1Knug%3D%3D
    • A.F. Lewis 1981 Fracture of neck of the femur: changing incidence BMJ (Clin Res Ed) 283 1217 1220 10.1136/bmj.283.6301.1217 1:STN:280: DyaL38%2Fpt1Knug%3D%3D
    • (1981) BMJ (Clin Res Ed) , vol.283 , pp. 1217-1220
    • Lewis, A.F.1
  • 26
    • 0021804389 scopus 로고
    • Evaluation of the Dunlap/Rippstein method for determination of femoral neck angles
    • 1:STN:280:DyaL2M7psFCrtQ%3D%3D
    • O. Reikeras A. Hoiseth A. Reigstad 1985 Evaluation of the Dunlap/Rippstein method for determination of femoral neck angles Acta Radiol Diagn 26 177 179 1:STN:280:DyaL2M7psFCrtQ%3D%3D
    • (1985) Acta Radiol Diagn , vol.26 , pp. 177-179
    • Reikeras, O.1    Hoiseth, A.2    Reigstad, A.3
  • 27
    • 0023149099 scopus 로고
    • Femoral anteversion: Assessment based on function axes
    • DOI 10.1002/jor.1100050111
    • Y. Yoshioka T.D. Cooke 1987 Femoral anteversion: assessment based on function axes J Orthop Res 5 86 91 3819914 10.1002/jor.1100050111 1:STN:280:DyaL2s7ktVCrtA%3D%3D (Pubitemid 17038857)
    • (1987) Journal of Orthopaedic Research , vol.5 , Issue.1 , pp. 86-91
    • Yoshioka, Y.1    Cooke, T.D.V.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.