메뉴 건너뛰기




Volumn 62, Issue 4, 2009, Pages 880-887

Sensitive J-coupled metabolite mapping using sel-MQC with selective multi-spin-echo readout

Author keywords

Apparent t2; Fast metabolic imaging; Lactate editing; PUFA editing; Sel MQC; Selective multiple quantum coherence; Spin echo chemical shift imaging

Indexed keywords

BIOMOLECULES; CHEMICAL SHIFT; METABOLITES; POLYUNSATURATED FATTY ACIDS; SPIN POLARIZATION;

EID: 70349627025     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.22108     Document Type: Article
Times cited : (10)

References (30)
  • 2
    • 0005716159 scopus 로고
    • A method for lactate detection in vivo by spectral editing without the need for double irradiation
    • Williams SR, Gadian DG, Proctor E. A method for lactate detection in vivo by spectral editing without the need for double irradiation. J Magn Reson 1986;66:562-567.
    • (1986) J Magn Reson , vol.66 , pp. 562-567
    • Williams, S.R.1    Gadian, D.G.2    Proctor, E.3
  • 4
    • 45449121603 scopus 로고
    • A method for volume-localized lactate editing using zero-quantum coherence created in a stimulated-echo pulse sequence
    • Sotak CH, Freeman DM. A method for volume-localized lactate editing using zero-quantum coherence created in a stimulated-echo pulse sequence. J Magn Reson 1988;77:382-388.
    • (1988) J Magn Reson , vol.77 , pp. 382-388
    • Sotak, C.H.1    Freeman, D.M.2
  • 5
    • 0029267269 scopus 로고
    • Single-scan in vivo lactate editing with complete lipid and water suppression by selective multiple-quantum-coherence transfer (Sel-MQC) with application to tumors
    • He Q, Shungu DC, van Zijl PC, Bhujwalla ZM, Glickson JD. Single-scan in vivo lactate editing with complete lipid and water suppression by selective multiple-quantum-coherence transfer (Sel-MQC) with application to tumors. J Magn Reson B 1995;106:203-211.
    • (1995) J Magn Reson B , vol.106 , pp. 203-211
    • He, Q.1    Shungu, D.C.2    Van Zijl, P.C.3    Bhujwalla, Z.M.4    Glickson, J.D.5
  • 6
    • 0030188701 scopus 로고    scopus 로고
    • Proton detection of choline and lactate in EMT6 tumors by spin-echo-enhanced selective multiple-quantum- Coherence transfer
    • He Q, Bhujwalla ZM, Glickson JD. Proton detection of choline and lactate in EMT6 tumors by spin-echo-enhanced selective multiple-quantum- coherence transfer. J Magn Reson B 1996;112:18-25.
    • (1996) J Magn Reson B , vol.112 , pp. 18-25
    • He, Q.1    Bhujwalla, Z.M.2    Glickson, J.D.3
  • 7
    • 36849048182 scopus 로고    scopus 로고
    • In vivo MR spectroscopic imaging of polyunsaturated fatty acids (PUFA) in healthy and cancerous breast tissues by selective multiple-quantum coherence transfer (Sel-MQC): A preliminary study
    • He Q, Shkarin P, Hooley RJ, Lannin DR, Weinreb JC, Bossuyt VI. In vivo MR spectroscopic imaging of polyunsaturated fatty acids (PUFA) in healthy and cancerous breast tissues by selective multiple-quantum coherence transfer (Sel-MQC): a preliminary study. Magn Reson Med 2007;58:1079-1085.
    • (2007) Magn Reson Med , vol.58 , pp. 1079-1085
    • He, Q.1    Shkarin, P.2    Hooley, R.J.3    Lannin, D.R.4    Weinreb, J.C.5    Bossuyt, V.I.6
  • 10
    • 49049118849 scopus 로고    scopus 로고
    • Lactate imaging with Hadamard-encoded slice-selective multiple quantum coherence chemical- Shift imaging
    • Pickup S, Lee SC, Mancuso A, Glickson JD. Lactate imaging with Hadamard-encoded slice-selective multiple quantum coherence chemical- shift imaging. Magn Reson Med 2008;60:299-305.
    • (2008) Magn Reson Med , vol.60 , pp. 299-305
    • Pickup, S.1    Lee, S.C.2    Mancuso, A.3    Glickson, J.D.4
  • 11
    • 70349623173 scopus 로고    scopus 로고
    • Volume and multi-slice localizations using spatialspectral selective RF pulses for selective multiple-quantum (Sel-MQC) spectroscopic imaging of human breast cancer
    • He Q, Zhou XJ. Volume and multi-slice localizations using spatialspectral selective RF pulses for selective multiple-quantum (Sel-MQC) spectroscopic imaging of human breast cancer. In: Proceedings of the 13th Annual Meeting of ISMRM, Miami Beach, Florida, 2005. p 728.
    • Proceedings of the 13th Annual Meeting of ISMRM, Miami Beach, Florida, 2005 , pp. 728
    • He, Q.1    Zhou, X.J.2
  • 12
    • 4744372192 scopus 로고    scopus 로고
    • In vivo tumor lactate relaxation measurements by selective multiple-quantum-coherence (Sel-MQC) transfer
    • Erratum in: Magn Reson Med 2005;53:491
    • Muruganandham M, Koutcher JA, Pizzorno G, He Q. In vivo tumor lactate relaxation measurements by selective multiple-quantum-coherence (Sel-MQC) transfer. Magn Reson Med 2004;52:902-906. Erratum in: Magn Reson Med 2005;53:491.
    • (2004) Magn Reson Med , vol.52 , pp. 902-906
    • Muruganandham, M.1    Koutcher, J.A.2    Pizzorno, G.3    He, Q.4
  • 15
    • 49049127103 scopus 로고
    • Spatially resolved high resolution spectroscopy by "four- dimensional" NMR
    • Maudsley AA, Hilal SK, Perman WH, Simon HE. Spatially resolved high resolution spectroscopy by "four-dimensional" NMR. J Magn Reson 1983;51:147-152.
    • (1983) J Magn Reson , vol.51 , pp. 147-152
    • Maudsley, A.A.1    Hilal, S.K.2    Perman, W.H.3    Simon, H.E.4
  • 16
    • 0031300505 scopus 로고    scopus 로고
    • Theoretical Evaluation and Comparison of Fast Chemical Shift Imaging Methods
    • Pohmann R, von Kienlin M, Haase A. Theoretical evaluation and comparison of fast chemical shift imaging methods. J Magn Reson 1997; 129:145-160. (Pubitemid 127451427)
    • (1997) Journal of Magnetic Resonance , vol.129 , Issue.2 , pp. 145-160
    • Pohmann, R.1    Von Kienlin, M.2    Haase, A.3
  • 17
    • 33746850826 scopus 로고    scopus 로고
    • Spatial localization in nuclear magnetic resonance spectroscopy
    • Keevil SF. Spatial localization in nuclear magnetic resonance spectroscopy. Phys Med Biol 2006;51:579-636.
    • (2006) Phys Med Biol , vol.51 , pp. 579-636
    • Keevil, S.F.1
  • 18
  • 19
    • 0346019605 scopus 로고
    • Three-quantum nuclear magnetic resonance spectroscopy of liquid water: Intermolecular multiple quantum coherence generated by spin-cavity coupling
    • McCoy M, Warren WS. Three-quantum nuclear magnetic resonance spectroscopy of liquid water: intermolecular multiple quantum coherence generated by spin-cavity coupling. J Chem Phys 1990;93:858-860.
    • (1990) J Chem Phys , vol.93 , pp. 858-860
    • McCoy, M.1    Warren, W.S.2
  • 20
    • 0021132985 scopus 로고
    • Simple proton spectroscopic imaging
    • Dixon WT. Simple proton spectroscopic imaging. Radiology 1984;153: 189-194.
    • (1984) Radiology , vol.153 , pp. 189-194
    • Dixon, W.T.1
  • 21
    • 0025831477 scopus 로고
    • Three-point Dixon technique for true water/fat decomposition with B0 field inhomogeneity correction
    • Glover GH, Schneider E. Three-point Dixon technique for true water/fat decomposition with B0 field inhomogeneity correction. Magn Reson Med 1991;18:371-383.
    • (1991) Magn Reson Med , vol.18 , pp. 371-383
    • Glover, G.H.1    Schneider, E.2
  • 22
    • 0027501302 scopus 로고
    • Fast proton spectroscopic imaging of human brain using multiple spin- Echoes
    • DOI 10.1002/mrm.1910300403
    • Duyn JH, Moonen CT. Fast proton spectroscopic imaging of human brain using multiple spin-echoes. Magn Reson Med 1993;30:409-414. (Pubitemid 23300068)
    • (1993) Magnetic Resonance in Medicine , vol.30 , Issue.4 , pp. 409-414
    • Duyn, J.H.1    Moonen, C.T.W.2
  • 23
    • 0029073642 scopus 로고
    • Parametric multiecho proton spectroscopic imaging: Application to the rat brain in vivo
    • Dreher W, Leibfritz D. Parametric multiecho proton spectroscopic imaging: application to the rat brain in vivo. Magn Reson Imaging 1995;13:753-761.
    • (1995) Magn Reson Imaging , vol.13 , pp. 753-761
    • Dreher, W.1    Leibfritz, D.2
  • 26
    • 0001383542 scopus 로고
    • Selection of optimum parameters for pulse Fourier transform nuclear magnetic resonance
    • Becker ED, Ferretti JA, Gambhir PN. Selection of optimum parameters for pulse Fourier transform nuclear magnetic resonance. Anal Chem 1979;51:1413-1420.
    • (1979) Anal Chem , vol.51 , pp. 1413-1420
    • Becker, E.D.1    Ferretti, J.A.2    Gambhir, P.N.3
  • 27
    • 0027200329 scopus 로고
    • Automatic, localized in vivo adjustment of all first- And second-order shim coils
    • Gruetter R. Automatic, localized in vivo adjustment of all first- and second-order shim coils. Magn Reson Med 1993;29:804-811. (Pubitemid 23182863)
    • (1993) Magnetic Resonance in Medicine , vol.29 , Issue.6 , pp. 804-811
    • Gruetter, R.1
  • 29


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.