메뉴 건너뛰기




Volumn 21, Issue 10, 2009, Pages 1013-1016

Will the 13C-octanoic acid breath test ever replace scintigraphy as the gold standard to assess gastric emptying?

Author keywords

13C octanoic acid breath test; Gastric emptying; Scintigraphy

Indexed keywords

CARBON 13; OCTANOIC ACID; TECHNETIUM 99M; OCTANOIC ACID DERIVATIVE;

EID: 70049117062     PISSN: 13501925     EISSN: 13652982     Source Type: Journal    
DOI: 10.1111/j.1365-2982.2009.01388.x     Document Type: Short Survey
Times cited : (23)

References (21)
  • 1
    • 0004065822 scopus 로고
    • International Commission on Radiological Protection. London, UK. ICRP Publication 53, 226 (for 99mTc); 250 (for 111In)
    • International Commission on Radiological Protection. Radiation Dose to Patients from Radiopharmaceuticals. London, UK : ICRP Publication 53, 226 (for 99mTc); 250 (for 111In), 1988.
    • (1988) Radiation Dose to Patients from Radiopharmaceuticals.
  • 2
    • 0027164833 scopus 로고
    • Measurement of gastric-emptying rate of solids by means of a carbon-labeled octanoic-acid breath test
    • Ghoos YF, Maes BD, Geypens BJ et al. Measurement of gastric-emptying rate of solids by means of a carbon-labeled octanoic-acid breath test. Gastroenterology 1993 104 : 1640 1647.
    • (1993) Gastroenterology , vol.104 , pp. 1640-1647
    • Ghoos, Y.F.1    Maes, B.D.2    Geypens, B.J.3
  • 3
    • 0032040182 scopus 로고    scopus 로고
    • C-13 octanoic acid breath test: Valueless test for gastric emptying?
    • Perri F, Clemente R, Festa V, Andriulli A. C-13 octanoic acid breath test: valueless test for gastric emptying? Gastroenterology 1998 114 : 857 858.
    • (1998) Gastroenterology , vol.114 , pp. 857-858
    • Perri, F.1    Clemente, R.2    Festa, V.3    Andriulli, A.4
  • 4
    • 0037499884 scopus 로고    scopus 로고
    • Measurement of gastric emptying by C-13-octanoic acid breath test versus scintigraphy in diabetics
    • Zahn A, Langhans CD, Hoffner S et al. Measurement of gastric emptying by C-13-octanoic acid breath test versus scintigraphy in diabetics. Z Gastroenterol 2003 41 : 383 390.
    • (2003) Z Gastroenterol , vol.41 , pp. 383-390
    • Zahn, A.1    Langhans, C.D.2    Hoffner, S.3
  • 5
    • 0029662031 scopus 로고    scopus 로고
    • [C-13]Octanoic acid breath test for non-invasive assessment of gastric emptying in diabetic patients: Validation and relationship to gastric symptoms and cardiovascular autonomic function
    • Ziegler D, Schadewaldt P, Mirza AP et al. [C-13]Octanoic acid breath test for non-invasive assessment of gastric emptying in diabetic patients: validation and relationship to gastric symptoms and cardiovascular autonomic function. Diabetologia 1996 39 : 823 830.
    • (1996) Diabetologia , vol.39 , pp. 823-830
    • Ziegler, D.1    Schadewaldt, P.2    Mirza, A.P.3
  • 6
    • 0036318209 scopus 로고    scopus 로고
    • Simultaneous measurement of gastric emptying with a simple muffin meal using [C-13]octanoate breath test and scintigraphy in normal subjects and patients with dyspeptic symptoms
    • Bromer MQ, Kantor SB, Wagner DA, Knight LC, Maurer AH, Parkman HP. Simultaneous measurement of gastric emptying with a simple muffin meal using [C-13]octanoate breath test and scintigraphy in normal subjects and patients with dyspeptic symptoms. Dig Dis Sci 2002 47 : 1657 1663.
    • (2002) Dig Dis Sci , vol.47 , pp. 1657-1663
    • Bromer, M.Q.1    Kantor, S.B.2    Wagner, D.A.3    Knight, L.C.4    Maurer, A.H.5    Parkman, H.P.6
  • 7
    • 0031859334 scopus 로고    scopus 로고
    • Gastric emptying flow curves separated from carbon-labeled octanoic acid breath test results
    • Maes BD, Mys G, Geypens BJ, Evenepoel P, Ghoos YF, Rutgeerts PJ. Gastric emptying flow curves separated from carbon-labeled octanoic acid breath test results. Am J Physiol 1998 275 : G169 75.
    • (1998) Am J Physiol , vol.275 , pp. 169-75
    • Maes, B.D.1    Mys, G.2    Geypens, B.J.3    Evenepoel, P.4    Ghoos, Y.F.5    Rutgeerts, P.J.6
  • 9
  • 11
    • 0030612036 scopus 로고    scopus 로고
    • [C-13]octanoic acid breath test for gastric emptying of solids: Accuracy, reproducibility, and comparison with scintigraphy
    • Choi MG, Camilleri M, Burton DD, Zinsmeister AR, Forstrom LA, Nair KS. [C-13]octanoic acid breath test for gastric emptying of solids: accuracy, reproducibility, and comparison with scintigraphy. Gastroenterology 1997 112 : 1155 1162.
    • (1997) Gastroenterology , vol.112 , pp. 1155-1162
    • Choi, M.G.1    Camilleri, M.2    Burton, D.D.3    Zinsmeister, A.R.4    Forstrom, L.A.5    Nair, K.S.6
  • 12
    • 0033791788 scopus 로고    scopus 로고
    • Toward office-based measurement of gastric emptying in symptomatic diabetics using [C-13]octanoic acid breath test
    • Lee JS, Camilleri M, Zinsmeister AR et al. Toward office-based measurement of gastric emptying in symptomatic diabetics using [C-13]octanoic acid breath test. Am J Gastroenterol 2000 95 : 2751 2761.
    • (2000) Am J Gastroenterol , vol.95 , pp. 2751-2761
    • Lee, J.S.1    Camilleri, M.2    Zinsmeister, A.R.3
  • 13
    • 0035686231 scopus 로고    scopus 로고
    • Validation of a stable isotope gastric emptying test for normal, accelerated or delayed gastric emptying
    • Viramontes BE, Kim DY, Camilleri M et al. Validation of a stable isotope gastric emptying test for normal, accelerated or delayed gastric emptying. Neurogastroenterol Motil 2001 13 : 567 574.
    • (2001) Neurogastroenterol Motil , vol.13 , pp. 567-574
    • Viramontes, B.E.1    Kim, D.Y.2    Camilleri, M.3
  • 16
    • 44449161823 scopus 로고    scopus 로고
    • Retention, fixation, and loss of the [C-13] label: A review for the understanding of gastric emptying breath tests
    • Sanaka M, Yamamoto T, Kuyama Y. Retention, fixation, and loss of the [C-13] label: a review for the understanding of gastric emptying breath tests. Dig Dis Sci 2008 53 : 1747 1756.
    • (2008) Dig Dis Sci , vol.53 , pp. 1747-1756
    • Sanaka, M.1    Yamamoto, T.2    Kuyama, Y.3
  • 17
    • 2642510635 scopus 로고    scopus 로고
    • The Wagner-Nelson method can generate an accurate gastric emptying flow curve from (CO2)-C-13 data obtained by a C-13-labeled substrate breath test
    • Sanaka M, Yamamoto T, Ishii T, Kuyama Y. The Wagner-Nelson method can generate an accurate gastric emptying flow curve from (CO2)-C-13 data obtained by a C-13-labeled substrate breath test. Digestion 2004 69 : 71 8.
    • (2004) Digestion , vol.69 , pp. 71-8
    • Sanaka, M.1    Yamamoto, T.2    Ishii, T.3    Kuyama, Y.4
  • 18
    • 34250765189 scopus 로고    scopus 로고
    • The Wagner-Nelson method makes the [C-13]-breath test comparable to radioscintigraphy in measuring gastric emptying of a solid/liquid mixed meal in humans
    • Sanaka M, Nakada K, Nosaka C, Kuyama Y. The Wagner-Nelson method makes the [C-13]-breath test comparable to radioscintigraphy in measuring gastric emptying of a solid/liquid mixed meal in humans. Clin Exp Pharmacol Physiol 2007 34 : 641 644.
    • (2007) Clin Exp Pharmacol Physiol , vol.34 , pp. 641-644
    • Sanaka, M.1    Nakada, K.2    Nosaka, C.3    Kuyama, Y.4
  • 20
    • 33747875565 scopus 로고    scopus 로고
    • Assessment of the gastric emptying velocity by the C-13-octanoate breath test: Deconvolution versus a Wagner-Nelson analysis
    • Sanaka M, Yamamoto T, Osaki Y, Kuyama Y. Assessment of the gastric emptying velocity by the C-13-octanoate breath test: deconvolution versus a Wagner-Nelson analysis. J Gastroenterol 2006 41 : 638 646.
    • (2006) J Gastroenterol , vol.41 , pp. 638-646
    • Sanaka, M.1    Yamamoto, T.2    Osaki, Y.3    Kuyama, Y.4
  • 21
    • 70049100284 scopus 로고    scopus 로고
    • 13C-acetate processing on measurement of gastric emptying: A systematic investigation in health
    • 13C-acetate processing on measurement of gastric emptying: a systematic investigation in health. Neurogastroenterol Motil 2009 21 : 1047 e85.
    • (2009) Neurogastroenterol Motil , vol.21
    • Goetze, O.1    Fox, M.2    Kwiatek, M.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.